Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

SU-F-T-431: Dosimetric Validation of Acuros XB Algorithm for Photon Dose Calculation in Water

Purpose: To validate the Acuros XB algorithm implemented in Eclipse Treatment planning system version 11 (Varian Medical System, Inc., Palo Alto, CA, USA) for photon dose calculation. Methods: Acuros XB is a Linear Boltzmann transport equation (LBTE) solver that solves LBTE equation explicitly and gives result equivalent to Monte Carlo. 6MV photon beam from Varian Clinac-iX (2300CD) was used for dosimetric validation of Acuros XB. Percentage depth dose (PDD) and profiles (at dmax, 5, 10, 20 and 30 cm) measurements were performed in water for field size ranging from 2×2,4×4, 6×6, 10×10, 20×20, 30×30 and 40×40 cm{sup 2}. Acuros XB results were compared against measurements and anisotropic analytical algorithm (AAA) algorithm. Results: Acuros XB result shows good agreement with measurements, and were comparable to AAA algorithm. Result for PDD and profiles shows less than one percent difference from measurements, and from calculated PDD and profiles by AAA algorithm for all field size. TPS calculated Gamma error histogram values, average gamma errors in PDD curves before dmax and after dmax were 0.28, 0.15 for Acuros XB and 0.24, 0.17 for AAA respectively, average gamma error in profile curves in central region, penumbra region and outside field region were 0.17, 0.21, 0.42 for Acuros XB and 0.10, 0.22, 0.35 for AAA respectively. Conclusion: The dosimetric validation of Acuros XB algorithms in water medium was satisfactory. Acuros XB algorithm has potential to perform photon dose calculation with high accuracy, which is more desirable for modern radiotherapy environment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-560: Measurement of Dose Blurring Effect Due to Respiratory Motion for Lung Stereotactic Body Radiation Therapy (SBRT) Using Monte Carlo Based Calculation Algorithm

Purpose: Intra-fractional tumor motion due to respiration may potentially compromise dose delivery for SBRT of lung tumors. Even sufficient margins are used to ensure there is no geometric miss of target volume, there is potential dose blurring effect may present due to motion and could impact the tumor coverage if motions are larger. In this study we investigated dose blurring effect of open fields as well as Lung SBRT patients planned using 2 non-coplanar dynamic conformal arcs(NCDCA) and few conformal beams(CB) calculated with Monte Carlo (MC) based algorithm utilizing phantom with 2D-diode array(MapCheck) and ion-chamber. Methods: SBRT lung patients were planned on Brainlab-iPlan system using 4D-CT scan and ITV were contoured on MIP image set and verified on all breathing phase image sets to account for breathing motion and then 5mm margin was applied to generate PTV. Plans were created using two NCDCA and 4-5 CB 6MV photon calculated using XVMC MC-algorithm. 3 SBRT patients plans were transferred to phantom with MapCheck and 0.125cc ion-chamber inserted in the middle of phantom to calculate dose. Also open field 3×3, 5×5 and 10×10 were calculated on this phantom. Phantom was placed on motion platform with varying motion from 5, 10, 20 and 30 mm with duty cycle of 4 second. Measurements were carried out for open fields as well 3 patients plans at static and various degree of motions. MapCheck planar dose and ion-chamber reading were collected and compared with static measurements and computed values to evaluate the dosimetric effect on tumor coverage due to motion. Results: To eliminate complexity of patients plan 3 simple open fields were also measured to see the dose blurring effect with the introduction of motion. All motion measured ionchamber values were normalized to corresponding static value. For open fields 5×5 and 10×10 normalized central axis ion-chamber values were 1.00 for all motions but for 3×3 they were 1 up to 10mm motion and 0.97 and 0.87 for 20 and 30mm motion respectively. For SBRT plans central axis dose values were within 1% upto 10mm motions but decreased to average of 5% for 20mm and 8% for 30mm motion. Mapcheck comparison with static showed penumbra enlargement due to motion blurring at the edges of the field for 3×3,5×5,10×10 pass rates were 88% to 12%, 100% to 43% and 100% to 63% respectively as motion increased from 5 to 30mm. For SBRT plans MapCheck mean pass rate were decreased from 73.8% to 39.5% as motion increased from 5mm to 30mm. Conclusion: Dose blurring effect has been seen in open fields as well as SBRT lung plans using NCDCA with CB which worsens with increasing respiratory motion and decreasing field size(tumor size). To reduce this effect larger margins and appropriate motion reduction techniques should be utilized.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-01: A New Approach for Calculating Variable Relative Biological Effectiveness in IMPT Optimization

Purpose: To investigate the impact of a new approach for calculating relative biological effectiveness (RBE) in intensity-modulated proton therapy (IMPT) optimization on RBE-weighted dose distributions. This approach includes the nonlinear RBE for the high linear energy transfer (LET) region, which was revealed by recent experiments at our institution. In addition, this approach utilizes RBE data as a function of LET without using dose-averaged LET in calculating RBE values. Methods: We used a two-piece function for calculating RBE from LET. Within the Bragg peak, RBE is linearly correlated to LET. Beyond the Bragg peak, we use a nonlinear (quadratic) RBE function of LET based on our experimental. The IMPT optimization was devised to incorporate variable RBE by maximizing biological effect (based on the Linear Quadratic model) in tumor and minimizing biological effect in normal tissues. Three glioblastoma patients were retrospectively selected from our institution in this study. For each patient, three optimized IMPT plans were created based on three RBE resolutions, i.e., fixed RBE of 1.1 (RBE-1.1), variable RBE based on linear RBE and LET relationship (RBE-L), and variable RBE based on linear and quadratic relationship (RBE-LQ). The RBE weighted dose distributions of each optimized plan were evaluated in terms of different RBE values, i.e., RBE-1.1, RBE-L and RBE-LQ. Results: The RBE weighted doses recalculated from RBE-1.1 based optimized plans demonstrated an increasing pattern from using RBE-1.1, RBE-L to RBE-LQ consistently for all three patients. The variable RBE (RBE-L and RBE-LQ) weighted dose distributions recalculated from RBE-L and RBE-LQ based optimization were more homogenous within the targets and better spared in the critical structures than the ones recalculated from RBE-1.1 based optimization. Conclusion: We implemented a new approach for RBE calculation and optimization and demonstrated potential benefits of improving tumor coverage and normal sparing in IMPT planning.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-04: Kerma Area Product Calculation for Non-Uniform X-Ray Fields Using a Skin Dose Tracking System

Purpose: The functionality of the Dose-Tracking System (DTS) has been expanded to include the calculation of the Kerma-Area Product (KAP) for non-uniform x-ray fields such as result from the use of compensation filters during fluoroscopic procedures Methods: The DTS calculates skin dose during fluoroscopic interventions and provides a color-coded dose map on a patient-graphic model. The KAP is the integral of air kerma over the x-ray field and is usually measured with a transmission-ionization chamber that intercepts the entire x-ray beam. The DTS has been modified to determine KAP when there are beam non-uniformities that can be modeled. For example, the DTS includes models of the three compensation filters with tapered edges located in the collimator assembly of the Toshiba Infinix fluoroscopic C-Arm and can track their movement. To determine the air kerma after the filters, DTS includes transmission factors for the compensation filters as a function of kVp and beam filtration. A virtual KAP dosimeter is simulated in the DTS by an array of graphic vertices; the air kerma at each vertex is corrected by the field non-uniformity, which in this case is the attenuation factor for those rays which pass through the filter. The products of individual vertex air-kerma values for all vertices within the beam times the effective-area-per-vertex are summed for each x-ray pulse to yield the KAP per pulse and the cumulative KAP for the procedure is then calculated. Results: The KAP values estimated by DTS with the compensation filter inserted into the x-ray field agree within ± 6% with the values displayed on the fluoroscopy unit monitor, which are measured with a transmission chamber. Conclusion: The DTS can account for field non-uniformities such as result from the use of compensation filters in calculating KAP and can obviate the need for a KAP transmission ionization chamber. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP2-03: Validation of an SSDE-To-Organ-Dose Calculation Methodology Developed for Pediatric CT in An Adult Population

Purpose: To discover if a previously published methodology for estimating patient-specific organ dose in a pediatric population (5–55kg) is translatable to the adult sized patient population (> 55 kg). Methods: An adult male anthropomorphic phantom was scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations in the chest and abdominopelvic regions to determine absolute organ dose. Organ-dose-to-SSDE correlation factors were developed by dividing individual phantom organ doses by SSDE of the phantom; where SSDE was calculated at the center of the scan volume of the chest and abdomen/pelvis separately. Organ dose correlation factors developed in phantom were multiplied by 28 chest and 22 abdominopelvic patient SSDE values to estimate organ dose. The median patient weight from the CT examinations was 68.9 kg (range 57–87 kg) and median age was 17 years (range 13–28 years). Calculated organ dose estimates were compared to published Monte Carlo simulated patient and phantom results. Results: Organ-dose-to-SSDE correlation was determined for a total of 23 organs in the chest and abdominopelvic regions. For organs fully covered by the scan volume, correlation in the chest (median 1.3; range 1.1–1.5) and abdominopelvic (median 0.9; range 0.7–1.0) was 1.0 ± 10%. For organs that extended beyond the scan volume (i.e. skin bone marrow and bone surface) correlation was determined to be a median of 0.3 (range 0.1–0.4). Calculated patient organ dose using patient SSDE agreed to better than 6% (chest) and 15% (abdominopelvic) to published values. Conclusion: This study demonstrated that our previous published methodology for calculating organ dose using patient-specific SSDE for the chest and abdominopelvic regions is translatable to adult sized patients for organs fully covered by the scan volume.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-09: Fast Dose-Averaged LET and Biological Dose Calculations for Proton Therapy Using Graphics Cards

Purpose: To demonstrate fast and accurate Monte Carlo (MC) calculations of proton dose-averaged linear energy transfer (LETd) and biological dose (BD) on a Graphics Processing Unit (GPU) card. Methods: A previously validated GPU-based MC simulation of proton transport was used to rapidly generate LETd distributions for proton treatment plans. Since this MC handles proton-nuclei interactions on an event-by-event using a Bertini intranuclear cascade-evaporation model, secondary protons were taken into account. The smaller contributions of secondary neutrons and recoil nuclei were ignored. Recent work has shown that LETd values are sensitive to the scoring method. The GPU-based LETd calculations were verified by comparing with a TOPAS custom scorer that uses tabulated stopping powers, following recommendations by other authors. Comparisons were made for prostate and head-and-neck patients. A python script is used to convert the MC-generated LETd distributions to BD using a variety of published linear quadratic models, and to export the BD in DICOM format for subsequent evaluation. Results: Very good agreement is obtained between TOPAS and our GPU MC. Given a complex head-and-neck plan with 1 mm voxel spacing, the physical dose, LETd and BD calculations for 10{sup 8} proton histories can be completed in ∼5 minutes using a NVIDIA Titan X card. The rapid turnover means that MC feedback can be obtained on dosimetric plan accuracy as well as BD hotspot locations, particularly in regards to their proximity to critical structures. In our institution the GPU MC-generated dose, LETd and BD maps are used to assess plan quality for all patients undergoing treatment. Conclusion: Fast and accurate MC-based LETd calculations can be performed on the GPU. The resulting BD maps provide valuable feedback during treatment plan review. Partially funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-03: Feasibility of CBCT-Based Proton Dose Calculation Using a Histogram-Matching Algorithm in Proton Beam Therapy

Purpose: The aim of this study was to confirm On-Board Imager cone-beam computed tomography (CBCT) using a histogram-matching algorithm as a useful method for proton dose calculation in head and neck radiotherapy. Methods: We studied one head and neck phantom and ten patients with head and neck cancer treated using intensity-modulated radiation therapy (IMRT) and proton beam therapy. We modified Hounsfield unit (HU) values of CBCT (mCBCT) using a histogram-matching algorithm. In order to evaluate the accuracy of the proton dose calculation, we compared dose differences in dosimetric parameters (Dmean) for clinical target volume (CTV), planning target volume (PTV) and left parotid and proton ranges (PR) between the planning CT (reference) and CBCT or mCBCT, and gamma passing rates of CBCT and mCBCT. To minimize the effect of organ deformation, we also performed image registration. Results: For patients, the average differences in Dmean for CTV, PTV, and left parotid between planning CT and CBCT were 1.63 ± 2.34%, 3.30 ± 1.02%, and 5.42 ± 3.06%, respectively. Similarly, the average differences between planning CT and mCBCT were 0.20 ± 0.19%, 0.58 ±0.43%, and 3.53 ±2.40%, respectively. The average differences in PR between planning CT and CBCT or mCBCT of a 50° beam for ten patients were 2.1 ± 2.1 mm and 0.3 ± 0.5 mm, respectively. Similarly, the average differences in PR of a 120° beam were 2.9 ± 2.6 mm and 1.1 ± 0.9 mm, respectively. The average dose and PR differences of mCBCT were smaller than those of CBCT. Additionally, the average gamma passing rates of mCBCT were larger than those of CBCT. Conclusion: We evaluated the accuracy of the proton dose calculation in CBCT and mCBCT with the image registration for ten patients. Our results showed that HU modification using a histogram-matching algorithm could improve the accuracy of the proton dose calculation.

60 APPLIED LIFE SCIENCES↗

Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images

Purpose: Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. Methods: The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity values of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose–volume histogram parameters and 3D gamma criteria. Results: In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm gamma index criteria were over 91%, 85%, and 38% with heterogeneous, dual bulk, and homogeneous sCTs, respectively. There were no significant changes to gamma index pass rates for IMPT plans first optimized in CT and then calculated in heterogeneous sCT versus IMPT plans first optimized in heterogeneous sCT and then calculated on standard CT. Conclusions: This study demonstrates that proton therapy dose calculations on heterogeneous sCTs are in good agreement with plans generated with standard planning CT. An MRI-only based RTP workflow is feasible in IMPT for brain tumors and prostate cancers.

60 APPLIED LIFE SCIENCES↗

Calculation of Spectroscopic Constants and Radiative Parameters for the B{sup 1}Π–X{sup 1}Σ{sup +} Electronic Transition of the LiCs Molecule

The spectroscopic constants (vibrational, rotational, and centrifugal) and the radiative parameters (Einstein coefficients for spontaneous emission, oscillator strengths for absorption, Franck–Condon factors, R{sub v'v'} centroids, and wavenumbers of rotational lines) of rovibronic transitions in the systems of bands B{sup 1}Π–X{sup 1}Σ{sup +} (0 ≤v'≤ 25, 0 ≤v'≤ 49, j = 0, 30, 50, 60, 70) of the LiCs molecule, as well as the radiative lifetimes of the excited electronic state, are calculated. Calculations are performed based on semiempirical potential curves constructed in this work. The calculated spectroscopic constants are compared with experimental values. The radiative lifetimes are calculated for the first time.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electronic structure and the local electroneutrality level of SiC polytypes from quasiparticle calculations within the GW approximation

The most important interband transitions and the local charge neutrality level (CNL) in silicon carbide polytypes 3C-SiC and nH-SiC (n = 2-8) are calculated using the GW approximation for the self energy of quasiparticles. The calculated values of band gap E{sub g} for various polytypes fall in the range 2.38 eV (3C-SiC)-3.33 eV (2H-SiC) and are very close to the experimental data (2.42-3.33 eV). The quasiparticle corrections to E{sub g} determined by DFT-LDA calculations (about 1.1 eV) are almost independent of the crystal structure of a polytype. The positions of CNL in various polytypes are found to be almost the same, and the change in CNL correlates weakly with the change in E{sub g}, which increases with the hexagonality of SiC. The calculated value of CNL varies from 1.74 eV in polytype 3C-SiC to 1.81 eV in 4H-SiC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interaction of optical and interface phonons and their anisotropy in GaAs/AlAs superlattices: Experiment and calculations

The angular anisotropy of interface phonons and their interaction with optical phonons in (001) GaAs/AlAs superlattices are calculated and experimentally studied. Experiments were performed by Raman light scattering in different scattering geometries for phonons with the wave vector directed normally to the superlattice and along its layers. Phonon frequencies were calculated by the extended Born method taking the Coulomb interaction into account in the rigid-ion approximation. Raman scattering spectra were calculated in the Volkenshtein bond-polarizability approximation. Calculations confirmed that the angular anisotropy of phonons observed in experiments appears due to interaction (mixing) of optical phonons, in which atoms are mainly displaced normally to superlattices, with interface phonons (TO-IF modes). In the scattering geometry, when the wave vector lies in the plane of superlattice layers, the mixed TO-IF modes are observed under nonresonance conditions. The Raman spectra for TO-IF modes depend on the mixing of atoms at heteroboundaries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Burnup calculation by the method of first-flight collision probabilities using average chords prior to the first collision

A technique to calculate the burnup of materials of cells and fuel assemblies using the matrices of first-flight neutron collision probabilities rebuilt at a given burnup step is presented. A method to rebuild and correct first collision probability matrices using average chords prior to the first neutron collision, which are calculated with the help of geometric modules of constructed stochastic neutron trajectories, is described. Results of calculation of the infinite multiplication factor for elementary cells with a modified material composition compared to the reference one as well as calculation of material burnup in the cells and fuel assemblies of a VVER-1000 are presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Quantum Scattering Theory in Calculation of the Simplest Chemical Reactions (Dissociative Attachment, Dissociation, and Recombination)

Several parameters (cross section, reaction rate, etc.) of various processes in laser, atomic, and chemical physics are calculated using quantum scattering theory for a system of a few particles. Results of the study of electronic and atomic collisions with diatomic molecules and collisions of diatomic molecules in excited rovibrational states are discussed. Several approximations needed for calculations of real physical systems consisting of several bodies are analyzed. Such approximations can be used for simulation of direct reactions and reactions that yield intermediate transient complexes. Calculated cross sections of electronic and atomic collisions with diatomic molecules and collisions of diatomic molecules are compared with experimental data and results of alternative calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method to calculate fission-fragment yields Y(Z,N) versus proton and neutron number in the Brownian shape-motion model

In this study, we propose a method to calculate the two-dimensional (2D) fission-fragment yield Y(Z,N) versus both proton and neutron number, with inclusion of odd-even staggering effects in both variables. The approach is to use the Brownian shape-motion on a macroscopic-microscopic potential-energy surface which, for a particular compound system is calculated versus four shape variables: elongation (quadrupole moment Q 2 ), neck d, left nascent fragment spheroidal deformation ϵ f1 , right nascent fragment deformation ϵ f2 and two asymmetry variables, namely proton and neutron numbers in each of the two fragments. The extension of previous models 1) introduces a method to calculate this generalized potential-energy function and 2) allows the correlated transfer of nucleon pairs in one step, in addition to sequential transfer. In the previous version the potential energy was calculated as a function of Z and N of the compound system and its shape, including the asymmetry of the shape. We outline here how to generalize the model from the “compound-system” model to a model where the emerging fragment proton and neutron numbers also enter, over and above the compound system composition.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

No-core shell model calculations of the photonuclear cross section of 10B

Results of ab initio no-core, shell model calculations for the photonuclear cross section of 10B are presented using realistic two-nucleon (NN) chiral forces up to next-to-next-to-next-order (N3LO) softened by the similarity renormalization group method (SRG) with λ=2.02 fm -1 . The electric-dipole response function is calculated using the Lanczos method, with the effects of the continuum included via neutron escape widths derived from R-matrix theory and using the Lorentz integral transform method. The calculated cross section agrees well with experimental data in terms of structure as well as in absolute peak height, σ max =4.85 mb at photon energy ω=23.61 MeV, and integrated cross section 85.36 MeV. mb. We also test the Brink hypothesis by calculating the electric-dipole response for the first nine positive-parity states with J≠0 in 10 B and verify that dipole excitations built upon the ground and excited states have similar characteristics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PSL Uncertainty Calculator v. 1.2

The PSL Uncertainty Calculator can be used to determine the total uncertainty of a measurement system. In many measurement applications, the quantity of interest is not measured directly, but computed from a combination of several measured values. While the uncertainty of each measurand is typically straightforward to determine, total uncertainty of the output value requires calculation. This software calculates uncertainty using the framework provided by the Guide to Expression of Uncertainty in Measurements, JCGM100-2008E (GUM), and a Monte Carlo simulation as described by Supplement 1 to the GUM, by providing an easy to use graphical user interface and a Python package for running the calculations.

Delker, Collin↗

Ocpp 2.0.1. Interim Kpi Calculator

The project is split into four pieces. The first is a raw OCPP log parser. The second is a file splitter. The third is a message parser. The final piece is the Interim KPI calculator. The OCPP log parser was created from two different formats of raw OCPP 2.0.1 data. Its intended purpose is to extract device IDs and OCPP event messages from nontabular text logs. The parser looks for specific substrings in the logs to identify which of the two "standards" it should select from. The KPI generator does not perform any of its calculations in parallel. Instead, we opt for a naive batching approach. The splitter takes the file generated from the parser and creates many smaller files for each of the device IDs in the dataset. This allows the pandas queries in the log formatter to be iterate over a significantly smaller slice of data, increasing performance significantly. The message parser step takes messages from each of the files (containing distinct device IDs) and breaks the message out into pieces. The final result is a file with different columns specifying different attributes of the JSON message. The file is an aggregation of all different devices. This is the most complex portion of the code. The KPI calculator takes the parsed messages, as a single file, and calculates the KPI from that data. An excel file is produced with four sheets. These contain the metrics for Session Success, Charge Start Success, Charge End Success, and Charge Start Time. It includes the metrics for the different equations in the Interim KPI Implementation Guide as well as a weighted sum of the different equations for each KPI (excluding Charge End Success and Charge Start Time).

Quinn, Casey↗

Simple Battery Hazard Calculator

SAND2025-00455O Simple Battery Hazard Calculator is a software tool developed in Excel to analyze the electrical hazards of battery systems and determine the required personal protective equipment (PPE) for safe assembly and disassembly. It calculates potential arc flash incident energy, contact thermal hazard level, and recommends PPE based on parameters such as voltage, short circuit current, and over current protection trip time. The calculator uses a recognized method for calculating arc flash incident energy, which was previously inaccessible to most battery workers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David↗