Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

A Nonlinear Regression Method for Composite Protection Modeling of Induction Motor Loads

Protection equipment are used to prevent damages to induction motor loads by isolating those from the power network in the event of severe faults. Modeling the response of induction motor loads and their protection is vital for power system planning and operation, especially in understanding system's response moments after a fault has occurred. This article proposes an optimization based framework to generate composite protection models for commercial building motor loads. Introducing a mathematical abstraction, the task of finding a suitable (simplified) model of the composite protection scheme is formulated as a nonlinear regression problem. Numerical examples are provided to illustrate the application of the framework.

Kundu, Soumya↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IM3 Open Source Data Center Atlas

IM3 Open Source Data Center Atlas Description This dataset contains locations of existing data center facilities in the United States. Data center locations were derived from OpenStreetMap (OSM), a crowd-sourced database. Data points from OSM are processed in various ways to determine additional variables provided in the data including: facility area (square feet), associated US county, and US state. This dataset can be used to identify areas of concentrated data center development and inform government and private sector planning strategies for future buildout of data centers and the infrastructure necessary to support it. Usage Notes Validation of OSM-derived data center locations is an ongoing development under the IM3 project, and the database will be updated as new information becomes available. In some instances, both the data center area (e.g., campus) and individual data center buildings are included as overlapping areas in the database. Both values are retained. Data center points, buildings, and campus areas are provided as separate layers in the downloadable data package. Note that data items are not necessarily complete across layers. That is, a specific data center may only be present as a single point geometry in the "point" layer while other data centers are represented in both the campus and building layers. In some cases, data center campuses and/or buildings straddle a county boundary line. Mappings to both counties are retained in the database as separate rows. These data rows will have the same data center id information, but each will have different county information. Crowd-sourced data, by nature, relies on individuals and communities to provide information. As a result, some data may be missing where it has not yet been reported. As we collect information on additional data center locations and as OSM receives additional contributions, the database will be updated to capture additional data points not yet shown. Technical Information Data is available for download under the following formats: GeoPackage (GPKG) CSV Geospatial data is provided in the WGS84 (EPSG:4326) coordinate reference system. The GeoPackage download contains the following layers. See usage notes for more information. "point" "building" "campus" The "point" layer includes all data from OSM that had POINT geometry type (i.e., individual coordinates). The "building" layer includes all OSM data that did not have POINT geometry and where the building tag in the OSM export was neither equal to "no" or null. Data that did not meet the "point" or "building" qualification was assumed to be a facility campus and included in the "campus" layer. The dataset contains the following parameters. Variables provided by OSM are labeled with (OSM-provided). id - unique identification number (OSM-provided with prefix of "node/", "relation/" and similar attributes removed) state - name of US state state_abb - two letter US state abbreviation state_id - state ID number county - name of US county county_id - county ID number ref - reference numbers or codes (OSM-provided) operator - the name of the company, corporation, or person in charge facility (OSM-provided) name - name of facility (OSM-provided) sqft - surface area of facility polygon, measured in square feet. Only available for "building" and "campus" layers lat - latitude of data centroid point lon - longitude of data centroid point type – represented spatial information. One of "point", "building", or "campus". geometry – POLYGON geometry of area footprint (in "campus" and "building" layers) or POINT geometry of locations (in "point" layer). This parameter is not included in the csv download. Attribution Data center locations were derived from OpenStreetMap, which is made available at openstreetmap.org under the Open Database License (ODbL). US state and county boundary information was collected from the US Census Bureau for the year 2024, which is made publicly available at https://www.census.gov/geographies/mapping-files.html Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License The IM3 Open Source Data Center Atlas is made available under the Open Database License: http://opendatacommons.org/licenses/odbl/1.0/. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall [Pacific Northwest National Labor↗

IM3 Open Source Data Center Atlas

IM3 Open Source Data Center Atlas Description This dataset contains locations of existing data center facilities in the United States. Data center locations were derived from OpenStreetMap (OSM), a crowd-sourced database. Data points from OSM are processed in various ways to determine additional variables provided in the data including: facility area (square feet), associated US county, and US state. This dataset can be used to identify areas of concentrated data center development and inform government and private sector planning strategies for future buildout of data centers and the infrastructure necessary to support it. Usage Notes Validation of OSM-derived data center locations is an ongoing development under the IM3 project, and the database will be updated as new information becomes available. In some instances, both the data center area (e.g., campus) and individual data center buildings are included as overlapping areas in the database. Both values are retained. Data center points, buildings, and campus areas are provided as separate layers in the downloadable data package. Note that data items are not necessarily complete across layers. That is, a specific data center may only be present as a single point geometry in the "point" layer while other data centers are represented in both the campus and building layers. In some cases, data center campuses and/or buildings straddle a county boundary line. Mappings to both counties are retained in the database as separate rows. These data rows will have the same data center id information, but each will have different county information. Crowd-sourced data, by nature, relies on individuals and communities to provide information. As a result, some data may be missing where it has not yet been reported. As we collect information on additional data center locations and as OSM receives additional contributions, the database will be updated to capture additional data points not yet shown. Data items will occasionally be removed from OSM if they are misidentified, if they no longer exist, if they are duplicates of another item, or similar. For that reason, updated versions of this database may not contain all data center locations included in previous versions. Technical Information Data is available for download under the following formats: GeoPackage (GPKG) CSV Geospatial data is provided in the WGS84 (EPSG:4326) coordinate reference system. The GeoPackage download contains the following layers. See usage notes for more information. "point" "building" "campus" The "point" layer includes all data from OSM that had POINT geometry type (i.e., individual coordinates). The "building" layer includes all OSM data that did not have POINT geometry and where the building tag in the OSM export was neither equal to "no" or null. Data that did not meet the "point" or "building" qualification was assumed to be a facility campus and included in the "campus" layer. The dataset contains the following parameters. Variables provided by OSM are labeled with (OSM-provided). id - unique identification number (OSM-provided with prefix of "node/", "relation/" and similar attributes removed) state - name of US state state_abb - two letter US state abbreviation state_id - state ID number county - name of US county county_id - county ID number ref - reference numbers or codes (OSM-provided) operator - the name of the company, corporation, or person in charge facility (OSM-provided) name - name of facility (OSM-provided) sqft - surface area of facility polygon, measured in square feet. Only available for "building" and "campus" layers lat - latitude of data centroid point lon - longitude of data centroid point type – represented spatial information. One of "point", "building", or "campus". geometry – POLYGON geometry of area footprint (in "campus" and "building" layers) or POINT geometry of locations (in "point" layer). This parameter is not included in the csv download. Attribution Data center locations were derived from OpenStreetMap, which is made available at openstreetmap.org under the Open Database License (ODbL). US state and county boundary information was collected from the US Census Bureau for the year 2024, which is made publicly available at https://www.census.gov/geographies/mapping-files.html Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License The IM3 Open Source Data Center Atlas is made available under the Open Database License: http://opendatacommons.org/licenses/odbl/1.0/. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall [Pacific Northwest National Labor↗

DMTN-107: Options for Alert Production in LSST Operations Year 1

This document reviews five options for alert production in LSST Operations Year 1 (LOY1), taking into account any implications on LSST formal requirements including up-scopes, down-scopes or explicit violations. The Data Management System Science Team's preferred option for maximizing LSST science is to generate template images from as much of the data from the commissioning and/or science verification phases as possible and use them to run Difference Image Analysis and alert production during LOY1. A proposal to increase the sky area covered during commissioning via a "filler" scheduler program is also presented. As a potential moderate up-scope, this study presents an option to build interim templates on a $\sim$monthly basis during LOY1, which could increase the accessible sky area by ~1000-2000 deg**2 per month, and should be reconsidered closer to the start of Operations.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensor Incipient Fault Impacts on Building Energy Performance: A Case Study on a Multi-Zone Commercial Building

Existing studies show sensor faults/error could double building energy consumption and carbon emissions compared with the baseline. Those studies assume that the sensor error is fixed or constant. However, sensor faults are incipient in real conditions and there were extremely limited studies investigating the incipient sensor fault impacts systematically. This study filled in this research gap by studying time-developing sensor fault impacts to rule-based controls on a 10-zone office building. The control sequences for variable air volume boxes (VAV) with an air handling unit (AHU) system were selected based on ASHRAE Guideline 36-2018: High-Performance Sequences of Operation for HVAC Systems. Large-scale simulations on cloud were conducted (3600 cases) through stochastic approach. Results show (1) The site energy differences could go –3.3% lower or 18.1% higher, compared with baseline. (2) The heating energy differences could go –66.5% lower or 314.4% higher, compared with baseline. (3) The cooling energy differences could go –11.5% lower or 65.0% higher, compared with baseline. (4) The fan energy differences could go 0.15% lower or 6.9% higher, compared with baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources: Preprint

Integration of a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problem requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs) including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperformed other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

A case study of high-temperature polyetherimide film capacitor fabrication

Capacitors, as the basic building block of power electronics and electrical systems, are the major constraint of the increasingly integrated power systems that require new capable polymer dielectric films operating at higher temperatures >125 °C. Despite tremendous research efforts on the lab scale, there remains a considerable barrier and knowledge basis for converting polymeric films to functioning capacitors desired in actual applications. Here, the authors tackled the polyetherimide (PEI) film scale up issues and developed various engineering processes for film de-wrinkling, optimal metallization, static elimination, and capacitor fabrication improvement. The authors discovered various fabrication challenges such as the electrostatic charge, metallization scheme, winding tension, and end electrode disconnects. To fabricate a high yield of PEI capacitor bobbins, it is necessary to utilize static eliminators (radioactive ionizers), moderately thick aluminum metallization (15–30 Ω/sq), and winding tension (60–100 g). It is also effective to evaluate capacitance, dielectric loss, equivalent series resistance, and thermal cycling stability of capacitors. This work sheds some light on converting PEI films and other polymeric films to capacitors on a scale up fabrication effort. The practical learning from film handling to capacitor fabrication in this work provided the necessary knowledge for manufacturing high-temperature polar film capacitors.

36 MATERIALS SCIENCE↗

Detecting Important Drivers of Gridded Population Modeling With Machine Learning

High-resolution population datasets have been lever-aged across a broad swath of domains, such as climate change, public policy, humanitarian aid, and rescue operations, among others. Machine learning methods were adopted to generate high-resolution or gridded population estimates by using various geospatial input features such as buildings, roads, and nighttime lights. In this study, we evaluate the importance of population features using Random Forest models across three levels of analysis, utilizing permutation measures. Our research aims to address key questions to enhance our understanding of high-resolution population modeling, such as: Are certain features globally (10 countries collectively) more important than others? Do optimal features vary by country? Within each country, do feature importance differ across administrative units? What similarities exist in feature importance at the global, country, and administrative unit levels? To answer these questions, we leverage the Kneedle algorithm to automate the selection of optimum features. We find that there are patterns displayed by features across spatial boundaries, evidenced by the same feature being the most important indicator of population across 7 of the 10 countries modeled. Our findings indicate that while important features may vary across geographies, certain features consistently hold greater importance than others agnostic of geography.

Lebakula, Viswadeep [ORNL] (ORCID:0000000152935914↗

Effects on Structure’s Electromagnetic Shielding Effectiveness Considering Penetrating Cables Coupling Energy from HEMP Event

The threat of weaponized electromagnetic pulse (EMP) is a serious factor in defining power system resilience. Without adequate knowledge regarding the interaction between EMP and power system infrastructure, system personnel may be unable to plan for and operate during an EMP event and major blackouts could occur. This work studies the interaction between EMP and structures, specifically analyzing the shielding effectiveness of buildings emulating power generation facilities. The main focus is to determine how penetrating cables affect the structure’s shielding effectiveness. Several cable parameters including height above ground, radius, termination configuration, and length are analyzed via computational electromagnetic simulations. Results demonstrated penetrating cables can significantly diminish a structure’s shielding effectiveness, especially the electric field. Length of cable is the most influential parameter.

Mignardot, David↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Domestic Hot Water Temperature Maintenance Technology Review

Domestic hot water temperature maintenance (HWTM) is an important topic in facility management, and there are often opportunities to optimize systems to achieve energy, water, and maintenance savings. The main purpose of an HWTM system is to provide reliable hot water temperature at all fixtures with minimal wait time. This is done by replacing the standby heat losses from hot water sitting idle in pipes during periods of low demand. Traditionally, most commercial buildings do this by having water recirculate back to the water heater to be reheated. Other currently available HWTM systems are also discussed in this resource. HWTM systems can help maintain water at appropriate temperatures, minimize heat loss, and minimize delivery times to fixtures to improve the function of a building. This webpage includes a summary of HWTM options along with important considerations regarding occupant safety and comfort, and maintenance strategies for optimal and efficient operations. Domestic hot water (DHW) generation systems are referred to but are not the focus of this resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mercury Remediation Technology Development for Lower East Fork Poplar Creek (FY2020 Update)

Mercury (Hg) remediation is a high priority for the US Department of Energy (DOE) Oak Ridge Office of Environmental Management. Mercury contamination in the environment can be found at all three DOE facilities in Oak Ridge, but probably the greatest environmental risk concern relative to Hg on the Oak Ridge Reservation is associated with historical Hg losses at and near the Y-12 National Security Complex (Y-12). Water and fish from East Fork Poplar Creek (EFPC) downstream of Y-12 exceed regulatory thresholds. Because of the complexities of Hg transport and fate in the aquatic environment, conventional remedial options for EFPC are highly uncertain. DOE is using a phased adaptive management approach to Hg remediation at Y-12 with a focus in the next few years on construction of the Mercury Treatment Facility (MTF) to treat the most contaminated Y-12 outfall entering EFPC (DOE 2017a; DOE 2017b). Once operational, the MTF will provide additional protection against inadvertent releases of Hg into the stream from decontamination and decommissioning of Y-12 Hg-use buildings. Although the MTF is anticipated to substantially decrease Hg water concentrations and flux in the upper part of EFPC, research and technology development are needed to develop appropriate and long-term remedial solutions for the downstream environment. Since late 2014, the Oak Ridge Office of Environmental Management and URS | CH2M Oak Ridge LLC/Restoration Services, Inc. have supported DOE’s Oak Ridge National Laboratory (ORNL) Environmental Sciences Division staff in conducting field and laboratory studies to develop Hg remedial technology solutions for lower EFPC (LEFPC). A technology development strategy for LEFPC was developed in 2014 that was consistent with the adaptive management paradigm and DOE’s technology readiness level (TRL) guidelines (Peterson et al. 2015). Initially, a thorough review of the literature was conducted and site-specific information was collected to develop a broad number of potential technologies that might be applied in LEFPC. An adaptive management approach was then used to focus on technologies that might have the most promise and potential remediation benefit. Field and laboratory studies conducted from 2014 to 2020 have identified the major drivers of Hg flux and bioaccumulation in EFPC and narrowed the list of high-merit technologies that might be of use in remediating the downstream environment.

54 ENVIRONMENTAL SCIENCES↗

Mercury Remediation Technology Development for Lower East Fork Poplar Creek—FY 2021 Update

Mercury remediation is a high priority for the US Department of Energy (DOE) Oak Ridge Office of Environmental Management. Mercury contamination in the environment can be found at all three DOE facilities in Oak Ridge, Tennessee, but the greatest environmental risk concern relative to Hg on the Oak Ridge Reservation is likely associated with historical Hg losses at and near the Y-12 National Security Complex (Y-12). Mercury in water and fish from East Fork Poplar Creek (EFPC) downstream of Y-12 exceeds regulatory thresholds. Because of the complexities of Hg transport and fate in the aquatic environment, conventional remedial options for EFPC are highly uncertain. DOE is using a phased adaptive management approach to Hg remediation at Y-12, with a focus in the next few years on construction of the Mercury Treatment Facility (MTF) to treat the most contaminated Y-12 outfall entering EFPC (DOE 2017a; DOE 2017b). Once operational, the MTF will provide additional protection against inadvertent releases of Hg into the stream from decontamination and decommissioning of Y-12 Hg-use buildings. Although the MTF is anticipated to substantially decrease Hg water concentrations and flux in upper EFPC (UEFPC), research and technology development are needed to develop appropriate and longer-term remedial solutions for the downstream environment. Since late 2014, the Oak Ridge Office of Environmental Management and URS | CH2M Oak Ridge LLC/Restoration Services Inc. have supported DOE’s Oak Ridge National Laboratory (ORNL) Environmental Sciences Division staff in conducting field and laboratory studies to develop Hg remedial technology solutions for lower EFPC (LEFPC). Whereas previous annual reporting updates for Hg remediation technology development for LEFPC have focused on presenting detailed results from the previous fiscal year, this FY 2021 update takes a comprehensive, higher-level approach to the research and technology development activities conducted since 2014. The report is organized to be consistent with the three tasks defined in the LEFPC strategic plan

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Near-Term Reliability and Resilience (NTRR) (Final Report)

The Near-Term Reliability and Resiliency (NTRR) was awarded in December 2020 as an inter-lab project to examine the reliability and resilience of the electricity grid and natural gas transportation availability. The project builds on studies conducted by The North American Electric Reliability Corporation (NERC), the U.S. Department of Energy (DOE), and other non-governmental research and operational focused on reliability and resilience analyses challenges. The research was conceived to address near-term scenarios (within 10 years), when many local and regional policy transitions could begin to impact grid reliability, resilience, and supporting infrastructure availability. To integrate the natural gas interdependency, the team began with the generating capacity and demand projections from the 2020 NERC Long-Term Reliability Assessment and the Bulk Electric System (BES) transmission topologies defined in the Western Electricity Coordinating Council (WECC) Anchor Data Set, Eastern Interconnection Reliability Assessment Group Multi-Regional Modeling Working Group (ERAG/MMWG) Data Set, the team calculated baseline regional power sector gas demands from present electricity delivery year through the end of delivery year 2030/31 by applying security constrained economic dispatch. This demand was compiled along with demand projections for regional residential, commercial, and industrial natural gas demands from the most recent Energy Information Administration (EIA) Annual Energy Outlook Reference Case into Deloitte’s MarketBuilder® North American Gas Model. Through the application of these demands, MarketBuilder® was projected the topology of natural gas flows in the natural gas pipeline network across the interconnected North American system along with regional natural gas prices that may be seen by market participants in future years Additionally, contingencies and sensitivities focused on the built models of the Eastern Interconnection (EI) and Western Interconnection (WI). They address challenges from the following with the outcomes being an identification of performance under the extreme conditions and an identification of potential grid weaknesses that should be addressed to mitigate the reduced performance and improve the resilience and reliability of the specific regions as well as the National Grid: • Weather events including extreme heat, extreme cold, high wind, no wind, wind and solar forecasting errors, and wildfires. • Gas availability, factoring in supply disruption (contractual and physical), seasonal availability constraints, and infrastructure limitations; and • Transmission availability and congestion.

03 NATURAL GAS↗