Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

A Physical Model to Study the Effects of Nozzle Design on Dispersed Two-Phase Flows in a Slab Mold Casting Ultra-Low-Carbon Steels

The effects of nozzle design on dispersed, two-phase flows of the steel-argon system in a slab mold are studied using a water-air model with particle image velocimetry and ultrasound probe velocimetry techniques. Three nozzle designs were tested with the same bore size and different port geometries, including square (S), special bottom design with square ports (U), and circular (C). The meniscus velocities of the liquid increase two- or threefold in two-phase flows regarding one-phase flows using low flow rates of the gas phase. This effect is due to the dragging effects on bubbles by the liquid jets forming two-way coupled flows. Liquid velocities (primary phase) along the narrow face of the mold also are higher for two-phase flows. Flows using nozzle U are less dependent on the effects of the secondary phase (air). The smallest bubble sizes are obtained using nozzle U, which confirms that bubble breakup is dependent on the strain rates of the fluid and dissipation of kinetic energy in the nozzle bottom and port edges. Through dimensionless analysis, it was found that the bubble sizes are inversely proportional to the dissipation rate of the turbulent kinetic energy, ε{sup 0.4}. A simple expression involving ε, surface tension, and density of metal is derived to scale up bubble sizes in water to bubble sizes in steel with different degrees of deoxidation. The validity of water-air models to study steel-argon flows is discussed. Prior works related with experiments to model argon bubbling in steel slab molds under nonwetting conditions are critically reviewed.

36 MATERIALS SCIENCE↗

Solidification of Calcium Ferrite Melt Using Ultrasonic Vibration: Effect and Mechanism

Calcium ferrite (CF) is a very important binder phase in iron ore sintering processes. To improve the microstructure of CF, power ultrasound was introduced during its solidification process, and the effect of immersion depth of ultrasonic probe (IDUP) on the properties of CF was investigated in detail. The results indicated that the microstructure of CF was greatly refined; the grain size decreased from 2864 μm without ultrasonic vibration to 841 μm with ultrasonic vibration at an immersion depth of 30 mm. Without ultrasonic vibration, the density and compressive strength of CF slag were 3904 kg/m{sup 3} and 38.3 MPa, respectively. When the IDUP was increased from 10 to 30 mm, the density and compressive strength of CF increased from 4049 to 4452 kg/m{sup 3} and 52.5 to 87.3 MPa, respectively. Further, the reducibility of CF was examined. The reduction time, at the same reduction rate, decreased from 347 minutes without ultrasonic vibration to 200 minutes with ultrasonic vibration at an IDUP of 30 mm. The rate-limiting step was obviously improved, which may be attributable to the grain refinement of CF and composition segregation in the slag. In general, the properties of CF were greatly improved due to the cavitation and acoustic streaming of ultrasonic waves.

36 MATERIALS SCIENCE↗

Solidification Behavior of Calcium Ferrite Under Ultrasonic Vibration

Ultrasonic vibration was applied to the solidification process of calcium ferrite (CF) to modify the grain size and improve the homogeneity of the solidified microstructure. The effects of ultrasound on microstructure, density, compressive strength, and reducibility were studied. The acoustic pressure decreased and then increased along the axis symmetry due to the attenuation of acoustic pressure and reflection of ultrasonic waves in the melt under a fixed power. When the ultrasonic power was increased, the general acoustic pressure increased, which was beneficial to the avoidance of macropores and to improvement of the microstructure. Coarse acicular CF grains were significantly refined; the grain size decreased from 1967 to 442 μm when the ultrasonic power was increased from 0 to 300 W. The density of the samples increased from 4370 to 4680 kg/m{sup 3} due to cavitation and acoustic streaming effects. Ultrasonic vibration greatly improved the ultimate compressive strength of CF; the values were 41.8 ± 2.1 to 67.3 ± 3.4 MPa for ultrasonic powers of 100 to 300 W, respectively. Without ultrasonic treatment, it was only 37.4 ± 1.9 MPa. Ultrasonic vibration also influenced the reduction time of CF due to the composition segregation in the slag during solidification.

36 MATERIALS SCIENCE↗

Experimental Study of the Mold Flow Induced by a Swirling Flow Nozzle and Electromagnetic Stirring for Continuous Casting of Round Blooms

This study focuses on an experimental investigation of the fluid flow in round bloom continuous casting using a 1:3 model of the industrial casting process. A swirling flow nozzle, represented by the specific design of the RHI Magnesita GYRONOZZLE, is used to produce a swirling motion in the cylindrical mold. The test section is integrated into the Mini-LIMMCAST facility at HZDR, which is operated at room temperature using the ternary alloy GaInSn. Systematic measurements of horizontal and vertical velocity profiles are performed by means of the Ultrasound Doppler Velocimetry. The second part of the study focuses on the interaction between the flow driven by the GYRONOZZLE and concurrent electromagnetic stirring in the mold (M-EMS) by applying rotating magnetic fields (RMFs) at different magnetic flux densities. The effect of the GYRONOZZLE on the flow pattern inside the mold is examined with and without superimposed RMFs and compared to those of a standard single-port nozzle. The measurements reveal that the GYRONOZZLE induces a swirling flow in the whole mold. It is further shown that the influence of a simultaneously applied RMF is mainly restricted to the lower part of the mold since the transport of angular momentum to the top is suppressed by the jets pouring out from the GYRONOZZLE.

36 MATERIALS SCIENCE↗

Impact Damage Behavior of Vinyl Ester-, Epoxy-, and Nylon 6-Based Basalt Fiber Composites

Composite laminates reinforced by woven basalt fibers and based on different polymer matrices were prepared and mechanically characterized, in static and dynamic conditions, to compare the results and evaluate the influence of the matrix type. In this regard, a thermoplastic resin, polyamide 6 (PA6), and two thermosetting matrices, vinyl ester and epoxy grades, commonly used for high-performance applications, were considered. Indentation depth measurements carried out by a confocal microscope and ultrasound analyses performed on specimens subjected to falling dart tests at levels of impact energies lower than the perforation one permitted to evaluate the extent of plastic deformations and of subjected delaminations, respectively. These data have provided useful information about the involved damage mechanisms and highlighted interesting perspective of use for the eco-friendly thermoplastic sample.

36 MATERIALS SCIENCE↗

Imaging Approaches for Coronary Artery Anomalies: Purpose and Techniques

Purpose of Review: Comprehensive discussion of alternative techniques in imaging coronary artery anomalies (CAAs) in different diagnostic scenarios. Recent Findings: At primary screening, intramural course essentially correlates with stenosis and clinical repercussion in some types of CAAs. Potential clinical aims in imaging patients with CAAs may be primary screening, severity evaluation, preoperative planning, and postoperative follow-up. Appropriate techniques are echocardiography, magnetic resonance imaging, computed tomography angiography, and intravascular ultrasound (IVUS). Rarely, IVUS may be needed in patients with potentially serious CAAs and has unique advantages and limitations. IVUS data are essential for in-depth knowledge of mechanisms of coronary dysfunction (exercise-related dynamic stenosis of variable severity) and for indicating interventional treatment. Summary: In adolescents or adults, intramural course of an anomalous coronary artery is the only important feature accompanied by stenosis of potential severity and is especially relevant in patients with a high-risk status (elite sport athletes, military recruits).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Invasive and Non-invasive Imaging Tools in the Diagnosis and Optimal Treatment of Patients with Spontaneous Coronary Artery Dissection

Purpose of Review: Spontaneous coronary artery dissection (SCAD) is a serious non-atherosclerotic disease, most frequently presenting as an acute coronary syndrome and affecting female patients. Considering that diagnosis of SCAD is often elusive, and its interventional treatment is associated to a higher rate of complications than obstructive atherosclerotic disease, we aim to review all the imaging tools currently available for the optimal diagnosis and treatment of this condition. Recent Findings: The developments in both invasive and non-invasive imaging alternatives to coronary angiography, such as intravascular ultrasound, optical coherence tomography, and computed coronary angiography, have largely contributed to appraise the epidemiology of SCAD, understand its causative pathophysiological mechanisms, and improve our ability to confirm doubtful cases of SCAD. Intracoronary imaging is also a valuable in deciding the best therapeutic approach and in guiding interventions in those patients requiring percutaneous treatment. Furthermore, non-invasive imaging is a key tool in ruling out significant extracoronary vascular abnormalities which frequently occur in patients with underlying conditions like fibromuscular dysplasia who develop SCAD. Summary: Main imaging tools employed in SCAD cases could have advantages and drawbacks. Focusing on different types of SCAD, operators should be able to choose the best imaging technique for diagnosis, management, and follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Enzymatic Hydrolysis of Sorghum Stalk by Supercritical Carbon Dioxide and Ultrasonic Pretreatment

Sorghum was pretreated by sole ultrasound or supercritical carbon dioxide (scCO{sub 2}), as well as the method combining both to intensify enzymatic hydrolysis. The effect of the time (1–5 h) and temperature (30–70 °C) on ultrasonic pretreatment was investigated, and the best condition was determined as 5 h and 50 °C with the EH sugar yield of 33.69%. The influence of the time (6–48 h), temperature (40–80 °C), and pressure (15–25 MPa) on scCO{sub 2} pretreatment were also discussed in this study. The optimum condition of scCO2 pretreatment was identified as 60 °C, 20 MPa, and 36 h with the EH sugar yield of 43.57%. Compared with the sole ultrasonic or scCO{sub 2} pretreatment, scCO{sub 2} associated with the subsequent ultrasonic pretreatment did not show significant improvement in sugar yield. However, 30 MPa was an extremely effective pressure, which led to 45.50% EH sugar yield with 60 °C, 6-h pretreatment. Finally, the change of the microscopic structures of the sorghum stalk after the pretreatment was investigated using scanning electron microscope (SEM) and X-ray diffraction (XRD).

60 APPLIED LIFE SCIENCES↗

MRI of Acute Abdominal and Pelvic Non-obstetric Conditions in Pregnancy

Purpose of Review: The evaluation of abdominal and pelvic pain in the pregnant patient presents unique challenges due to altered physiology and implications of radiation exposure on the fetus. In many instances, a radiologist must consider the potential risk of fetal injury from ionizing radiation and maintaining diagnostic quality imaging. This article will focus on the role of MR imaging and its applications in a variety of acute abdomen and pelvic non-obstetric conditions potentially affecting the pregnant patient. Recent Findings: Non-contrast MR imaging is routinely employed in the presence of an initial equivocal ultrasound. However, MR is playing an increasingly more important role in the imaging of the pregnant patient, potentially surpassing the utility of conventional imaging techniques. Summary: As radiologists become more comfortable interpretating abdominal and pelvic MRI, MR will play a bigger role in imaging the pregnant patient in the emergency room, in the years to come.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging of the Gallbladder with Multi-energy CT

Purpose of Review: The goal of this review article is to provide an overview of applications of multi-energy CT as they pertain to gallbladder imaging. We discuss benefits and shortcomings of MECT of various gallbladder pathology, with an emphasis on the imaging of gallstones and cholecystitis. It also touches on promising areas that warrant further investigation. Recent Findings: MECT has demonstrated improved sensitivity for cholelithiasis compared to conventional single-energy CT, with added value of MECT reconstructions, particularly virtual monoenergetic reconstructions, to detect isoattenuating gallstones. MECT iodine maps and virtual monoenergetic images potentially add value in evaluating other gallbladder pathologies, including detecting complications of acute cholecystitis, characterization of xanthogranulomatous cholecystitis and adenomyomatosis, and identifying and evaluating the extent of gallbladder carcinoma. Summary: MECT is emerging as a useful exam to evaluate the gallbladder, particularly in the setting of acute abdominal pain, and has the potential to eliminate the need for other imaging exams such as ultrasound.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anomalous temperature-dependent Young's modulus of a cast LAST (Pb-Sb-Ag-Te) thermoelectric material

Thermomechanical characterization is important to material evaluation and device design in the development of thermoelectric technology. In this study, we utilize the resonant ultrasound spectroscopy (RUS) technique to examine the elastic behavior of a cast LAST (Pb Sb Ag Te) material with a composition of Ag0.86Pb19Sb1.0Te20 between room temperature and 823 K. The temperature-dependent Young s modulus exhibits a monotonically decreasing trend with increasing temperature. However, an abnormal slope change in the Young s modulus temperature curve around 500 K is observed. In addition, hysteresis between heating and cooling data in the temperature range of 450 550 K is observed, which appears to be dependent on the heating/cooling rate during the RUS experiments such that the hysteresis disappears when the heating/cooling rate was decreased from 5 to 2 K min 1. In this study we propose an order disorder transition model for the anomalous temperature-dependent Young s modulus behavior observed in this study.

36 MATERIALS SCIENCE↗

Microstrain temperature evolution in beta-eurcryptite ceramics: Measurement and model

Mechanisms of microcracking and stress release in {beta}-eucryptite ceramics were investigated by applying a combination of neutron diffraction (ND), dilatometry and the Integrity Factor Model (IFM). It was observed that the macroscopic thermal expansion of solid samples closely follows the lattice thermal expansion as a function of temperature, and both are dominated by microcracks closing (during heating) and opening (during cooling). Analogous experiments on powders showed that the stresses that manifest peak shift are indeed relieved by comminution, and that the resulting lattice thermal expansion can be considered as unconstrained. By means of Rietveld refinement of the ND data, the evolution with temperature of peak width parameters linked to strain distributions along the basal, pyramidal and axial planes could also be extracted. The peak width parameters S{sub HKL} correlated well with the strains calculated by peak shift and with the model results. Furthermore, while the peak shifts showed that the powders are basically stress free, the S{sub HKL} showed a strong evolution of the peak width. Powders carry, therefore, a measurable strain distribution inside the particles, owing to the thermal expansion anisotropy of the crystallites. The IFM allowed this behavior to be rationalized, and the effect of microcracking on thermal expansion to be quantified. Experimental data allowed accurate numerical prediction of microcracking on cooling and of the evolution of microstresses. They also allowed the derivation of the material elastic modulus from bulk thermal expansion curves through the IFM concept. Ultrasound resonance measurements of the elastic modulus strongly support these theoretical predictions.

36 MATERIALS SCIENCE↗

The elastic properties of beta-eucryptite in the glassy and microcracked crystalline states

Amorphous and crystalline {beta}-eucryptite (LiAlSiO{sub 4}) specimens were prepared with controlled grain sizes and varying levels of microcracking, and their elastic moduli were determined using resonant ultrasound spectroscopy. It was found that the relationship between Young's modulus, Poisson's ratio and degree of microcracking in these materials can be described well with fracture-mechanics-based models. It was also found that if glassy {beta}-eucryptite is considered to be a microcracked medium in which broken Si-O bonds, with respect to the crystalline material, constitute microcracks, then its elastic properties can be described equally well by these models. Such considerations are explained by noting the differences in atomic bond density among the different states of the material and by accounting for differences in strain energy release rate measurements on glass and ceramic specimens.

36 MATERIALS SCIENCE↗

Investigation of Magnetic Signatures and Microstructures for Heat-Treated Ferritic/Martensitic HT-9 Alloy

There is increased interest in improved methods for in-situ nondestructive interrogation of materials for nuclear reactors in order to ensure reactor safety and quantify material degradation (particularly embrittlement) prior to failure. Therefore, a prototypical ferritic/martensitic alloy, HT-9, of interest to the nuclear materials community was investigated to assess microstructure effects on micromagnetics measurements – Barkhausen noise emission, magnetic hysteresis measurements, and first-order reversal curve analysis – for samples with three different heat-treatments. Microstructural and physical measurements consisted of high-precision density, resonant ultrasound elastic constant determination, Vickers microhardness, grain size, and texture. These were varied in the HT-9 alloy samples and related to various magnetic signatures. In parallel, a meso-scale microstructure model was created for alpha iron and effects of polycrystallinity and demagnetization factor were explored. It was observed that Barkhausen noise emission decreased with increasing hardness and decreasing grain size (lath spacing) while coercivity increased. The results are discussed in terms of the use of magnetic signatures for nondestructive interrogation of radiation damage and other microstructural changes in ferritic/martensitic alloys.

Environmental Molecular Sciences Laboratory↗

Ferroelasticity in a metal-organic framework perovskite; towards a new class of multiferroics

A metal–organic framework perovskite, [(CH 2 ) 3 NH 2 ][Mn(HCOO) 3 ], exhibits a weakly first order ferroelastic phase transition at ~272 K, from orthorhombic Pnma to monoclinic P2 1 /n, and a further transition associated with antiferromagnetic ordering at ~8.5 K. The main structural changes, through the phase transition, are orientational ordering of the azetidium groups and associated changes in hydrogen bonding. In marked contrast to conventional improper ferroelastic oxide perovskites, the driving mechanism is associated with the X-point of the cubic Brillouin zone rather than being driven by R- and M-point octahedral tilting. The total ferroelastic shear strain of up to ~5% is substantially greater than found for typical oxide perovskites, and highlights the potential of the flexible framework to undergo large relaxations in response to local structural changes. Measurements of elastic and anelastic properties by resonant ultrasound spectroscopy show some of the characteristic features of ferroelastic materials. In particular, acoustic dissipation below the transition point can be understood in terms of mobility of twin walls under the influence of external stress with relaxation times on the order of ~10 -7 s. Elastic softening as the transition is approached from above is interpreted in terms of coupling between acoustic modes and dynamic local ordering of the azetidium groups. Subsequent stiffening with further temperature reduction is interpreted in terms of classical strain–order parameter coupling at an improper ferroelastic transition which is close to being tricritical. By way of contrast, there are no overt changes in elastic or anelastic properties near 9 K, implying that any coupling of the antiferromagnetic order parameter with strain is weak or negligible.

Li, Wei↗

Propagation of sound waves through a spatially homogeneous but smoothly time-dependent medium

The propagation of sound through a spatially homogeneous but non-stationary medium is investigated within the framework of fluid dynamics. For a non-vortical fluid, especially, a generalized wave equation is derived for the (scalar) potential of the fluid velocity distribution in dependence of the equilibrium mass density of the fluid and the sound wave velocity. A solution of this equation for a finite transition period τ is determined in terms of the hypergeometric function for a phenomenologically realistic, sigmoidal change of the mass density and sound wave velocity. Using this solution, it is shown that the energy flux of the sound wave is not conserved but increases always for the propagation through a non-stationary medium, independent of whether the equilibrium mass density is increased or decreased. It is found, moreover, that this amplification of the transmitted wave arises from an energy exchange with the medium and that its flux is equal to the (total) flux of the incident and the reflected wave. An interpretation of the reflected wave as a propagation of sound backward in time is given in close analogy to Feynman and Stueckelberg for the propagation of anti-particles. The reflection and transmission coefficients of sound propagating through a non-stationary medium is analyzed in more detail for hypersonic waves with transition periods τ between 15 and 200 ps as well as the transformation of infrasound waves in non-stationary oceans. -- Highlights: •Analytically exact study of sound propagation through a non-stationary medium. •Energy exchange between the non-stationary medium and the sound wave. •Transformation of hypersonic and ultrasound frequencies in non-stationary media. •Propagation of sound backward in time in close analogy to anti-particles. •Prediction of tsunamis both in spatially and temporally inhomogeneous oceans.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-temperature route to metal titanate perovskite nanoparticles for photocatalytic applications

MTiO 3 (M = Ca, Sr, Ba) nanoparticles were synthesized by a one-step room-temperature ultrasound synthesis in ionic liquid. The samples we gathered are characterized by X-ray diffraction, scanning electron microscopy, nitrogen adsorption, UV–vis diffuse reflectance, Raman and IR spectroscopy and their capability in photocatalytic hydrogen evolution and methylene blue degradation was tested. Powder X-ray diffraction and Raman spectroscopic investigations revealed the products to crystallize in the cubic perovskite structure. SEM observations showed that the obtained CaTiO 3 consists of nanospheres, BaTiO 3 of raspberry-like shaped particles of 20 nm in diameter. SrTiO 3 particles have cubic-like morphology with an edge length varying from 100 to 300 nm. SrTiO 3 exhibited the highest catalytic activity for photocatalytic H 2 evolution using only 0.025 wt.% Rh as co-catalyst and for the degradation of methylene blue under UV irradiation. The influence of parameters such as synthesis method, calcination temperature, and doping with nitrogen on the morphology, crystallinity, chemical composition, and photocatalytic acivity of SrTiO 3 was studied. Heating the as-prepared SrTiO 3 to 700 °C for extended time leads to a decrease in surface area and catalytic activity. Ionothermal prepared SrTiO 3 exhibits a higher activity than sonochemically prepared one without co-catalyst due to a synergistic effect of anatase which is present in small amount as a by-phase. Furthermore, after photodeposition of Rh, however, the activity is lower than that of the sonochemically prepared SrTiO 3 . Nitrogen-doped SrTiO 3 showed photocatalytic acivity under visible light irradiation.

36 MATERIALS SCIENCE↗

Serum anti-Ku86 is a potential biomarker for early detection of hepatitis C virus-related hepatocellular carcinoma

Highlights: Black-Right-Pointing-Pointer Overexpression of Ku86 in human liver cancer was shown by immunohistochemistry. Black-Right-Pointing-Pointer Serum anti-Ku86 was significantly elevated in early hepatocellular carcinoma. Black-Right-Pointing-Pointer Anti-Ku86 may be more sensitive than the conventional markers for early detection. Black-Right-Pointing-Pointer Serum anti-Ku86 significantly decreased after surgical resection of liver tumors. Black-Right-Pointing-Pointer Elevation of serum anti-Ku86 in other non-liver solid tumors was minimal. -- Abstract: Hepatocellular carcinoma (HCC), the predominant form of primary liver cancer, is one of the most common cancers worldwide and the third most common cause of cancer-related death. Imaging studies including ultrasound and computed tomography are recommended for early detection of HCC, but they are operator dependent, costly and involve radiation. Therefore, there is a need for simple and sensitive serum markers for the early detection of hepatocellular carcinoma (HCC). In our recent proteomic studies, a number of proteins overexpressed in HCC tissues were identified. We thought if the serum autoantibodies to these overexpressed proteins were detectable in HCC patients. Of these proteins, we focused on Ku86, a nuclear protein involved in multiple biological processes and aimed to assess the diagnostic value of serum anti-Ku86 in the early detection of HCC. Serum samples were obtained prior to treatment from 58 consecutive patients with early or relatively early hepatitis C virus (HCV)-related HCC and 137 patients with HCV-related liver cirrhosis without evidence of HCC. Enzyme immunoassays were used to measure serum levels of autoantibodies. Serum levels of anti-Ku86 antibodies were significantly elevated in HCC patients compared to those in liver cirrhosis patients (0.41 {+-} 0.28 vs. 0.18 {+-} 0.08 Abs at 450 nm, P < 0001). Setting the cut-off level to give 90% specificity, anti-Ku86 was positive in 60.7% of stage I solitary tumor <2 cm in diameter, whereas the sensitivities of alpha-fetoprotein (AFP) and protein induced by vitamin K absence or antagonist II (PIVKA-II) were 17.8% and 21.4%, respectively. The results of ROC analyses indicated the better performance of anti-Ku86 for early detection of HCC. Serum anti-Ku86 levels decreased after surgical resection of the tumors in the 12 HCC cases tested, Elevation of anti-Ku86 in solid tumors other than liver was minimal. Serum anti-Ku86 is a potential biomarker for early detection of HCV-related HCC. Further studies in a larger number of HCC patients with various etiologies are needed to further evaluate the diagnostic and pathophysiological roles of elevation of serum anti-Ku86 in early HCC.

60 APPLIED LIFE SCIENCES↗