Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Electronic structure and morphology of epitaxial Bi{sub 2}Te{sub 2}Se topological insulator films

Epitaxial films of the ternary topological insulator Bi{sub 2}Te{sub 2}Se were grown on Si(111) substrates and investigated for their surface electronic properties and morphology. We employ a Se-capping procedure allowing for the preparation of clean films in the surface-analysis experimental setups. Using angle-resolved photoelectron spectroscopy, we determine the dispersion of the topological surface state. With time after surface preparation, the spectroscopic features in the surface electronic structure exhibit significant temperature-dependent shifts to higher binding energies. Scanning tunneling microscopy images show terraces with typical step edge separations of 50 nm–150 nm. X-ray photoelectron spectroscopy indicates an increased Se concentration at the surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Dark Lock-in Thermography Identifies Solder Bond Failure as the Root Cause of Series Resistance Increase in Fielded Solar Modules

Correlating the electrical performance of photovoltaic modules to the spatially resolved photoluminescence, electroluminescence, and dark lock-in thermography (DLIT) images is an important long-term goal for developing solar cell technology. These images offer highly sophisticated and detailed information about the spatial distribution and (if imaged at successive time intervals) temporal degradation of local series and shunt resistances. There have been extensive studies to correlate these imaging techniques to local characteristics at the cell level. However, it has been difficult to extract and quantify module-level information from the techniques. In this study, we interpret module current-voltage (I-V) measurements along with corresponding DLIT images within a module-scale simulation framework, demonstrating that series resistance degradation of the module I-V characteristics, in this case, can be attributed to solder bond failures. Our simulations highlight how current crowding associated with a failed solder joint (or a section of the solder pad) translates to the characteristic point-like (asymmetric doublet) heating pattern in neighboring solder joints (or the neighboring regions of the solder pad). Overall, the correlation between series resistance and solder joint degradation could inform expedited diagnosis of field degradation of solar modules.

42 ENGINEERING↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Nondestructive Strain Measurement System Used to Determine Surface Strain on Fibers

Small-diameter structural fibers are being considered as reinforcements for high temperature ceramic matrix composite materials, and thus they require characterization. At the NASA Lewis Research Center, a nondestructive optical technique was used to determine surface strain on a structural fiber, in real time, as it was pulled in a tensile test machine. With this technique, interference or speckle patterns from the laser illuminated fiber test specimen are recorded. As the fiber is pulled, its speckle pattern shifts in proportion to the strain, translation, and rotation components of the sample deformation. Shifting speckle patterns are detected in real time by two linear charge-coupled discharge (CCD) camera arrays, and the images are processed by a hardware correlator. Surface strain is selectively detected on fibers with diameters on the order of 100 mm and can be resolved to 19 microstrain. This system was designed to be robust and compact and generally does not require surface preparation of the structural fibers. For strain detection, two laser beams are positioned incident on the structural fiber being tested, as shown in the photograph, where the test specimen is mounted in a tensile test machine via two coupons. As the fiber is pulled, the speckle pattern produced from each laser beam is detected by one of two CCD arrays located inside the tube on the right side of the photograph.

Tuma, Margaret L.↗

Facile hyperpolarization chemistry for molecular imaging and metabolic tracking of [1– 13 C]pyruvate in vivo

Hyperpolarization chemistry based on reversible exchange of parahydrogen, also known as Signal Amplification By Reversible Exchange (SABRE), is a particularly simple approach to attain high levels of nuclear spin hyperpolarization, which can enhance NMR and MRI signals by many orders of magnitude. SABRE has received significant attention in the scientific community since its inception because of its relative experimental simplicity and its broad applicability to a wide range of molecules, however, in vivo detection of molecular probes hyperpolarized by SABRE has remained elusive. Here we describe a first demonstration of SABRE-hyperpolarized contrast detected in vivo, specifically using hyperpolarized [1– 13 C]pyruvate. Biocompatible formulations of hyperpolarized [1– 13 C]pyruvate in, both, methanol-water, and ethanol-water mixtures followed by dilution with saline and catalyst filtration were prepared and injected into healthy Sprague Dawley and Wistar rats. Effective hyperpolarization-catalyst removal was performed with silica filters without major losses in hyperpolarization. Metabolic conversion of pyruvate to lactate, alanine, and bicarbonate was detected in vivo. Pyruvate-hydrate was also observed as a minor byproduct. Measurements were performed on the liver and kidney at 4.7 T via time-resolved spectroscopy and chemical-shift-resolved MRI. In addition, whole-body metabolic measurements were obtained using a cryogen-free 1.5 T MRI system, illustrating the utility of combining lower-cost MRI systems with simple, low-cost hyperpolarization chemistry to develop safe and scalable molecular imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CORONAL FUZZINESS MODELED WITH PULSE-HEATED MULTI-STRANDED LOOP SYSTEMS

Coronal active regions are observed to get increasingly fuzzy (i.e., increasingly confused and uniform) in increasingly hard energy bands or lines. We explain this as evidence of fine multi-temperature structure of coronal loops. To this end, we model bundles of loops made of thin strands, each heated by short and intense heat pulses. For simplicity, we assume that the heat pulses are all equal and triggered only once in each strand at a random time. The pulse intensity and cadence are selected so as to have steady active region loops ({approx}3 MK) on average. We compute the evolution of the confined heated plasma with a hydrodynamic loop model. We then compute the emission along each strand in several spectral lines, from cool ({<=}1 MK), to warm (2-3 MK) lines, detectable with Hinode/Extreme-ultraviolet Imaging Spectrometer, to hot X-ray lines. The strands are then put side by side to construct an active region loop bundle. We find that in the warm lines (2-3 MK) the loop emission fills all the available image surface. Therefore, the emission appears quite uniform and it is difficult to resolve the single loops, while in the cool lines the loops are considerably more contrasted and the region is less fuzzy. The main reasons for this effect are that, during their evolution, i.e., pulse heating and slow cooling, each strand spends a relatively long time at temperatures around 2-3 MK and it has a high emission measure during that phase, so the whole region appears more uniform or smudged. We predict that fuzziness should be reduced in the hot UV and X-ray lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a Highly Specific And Noninvasive Biosensor Suitable for Real-Time in Vivo Imaging of Mercury (II) Uptake

Mercury is a ubiquitous pollutant that when absorbed is extremely toxic to a wide variety of biochemical processes. Mercury (II) is a strong, invisible poison that is rapidly absorbed by tissues of the intestinal tract, kidneys, and liver upon ingestion. In this study, a novel fluorescence-based biosensor is presented that allows for the direct monitoring of the uptake and distribution of the metal under noninvasive in vivo conditions. With the introduction of a cysteine residue at position 205, located in close proximity to the chromophore, the green fluorescent protein (GFP) from Aequorea victoria was converted into a highly specific biosensor for this metal ion. The mutant protein exhibits a dramatic absorbance and fluorescence change upon mercuration at neutral pH. Absorbance and fluorescence properties with respect to the metal concentration exhibit sigmoidal binding behavior with a detection limit in the low nanomolar range. Time-resolved binding studies indicate rapid subsecond binding of the metal to the protein. The crystal structures obtained of mutant eGFP205C indicate a possible access route of the metal into the core of the protein. To our knowledge, this engineered protein is a first example of a biosensor that allows for noninvasive and real-time imaging of mercury uptake in a living cell. A major advantage is that its expression can be genetically controlled in many organisms to enable unprecedented studies of tissue specific mercury uptake.

36 MATERIALS SCIENCE↗

Physical and Chemical Morphology of Passively Sampled Environmental Films

Environmental surface films are important mediators in the fate and transport of persistent organic pollutants (POP) via largely uncharacterized mechanisms. This work presents the first analysis of the physical and chemical morphology of passively sampled environmental films. The films are developed in urban, sub-urban, and metropolitan locations for timescales ranging from 1 to 52 weeks by exposing polished silicon wafers to collect passively deposited tropospheric particulate matter. The time-dependent spatial morphology of the films is analyzed by bright-field, scanning electron, and atomic force microscopies. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging data are analyzed to report the film’s chemical morphology and speciation. We find that the film matrix presents an extremely complex physical and chemical system. Deposited PM sizes span six orders of magnitude (millimeter to nanometer regimes), and surface coverages range from ca. 5 % for one week films and ca. 98 % for 52 week films. We observe significant amounts of mineral dust, biogenic organics, and occasional indications of flora growth (i.e., spores). The films exhibit nanoscale surface features indicative of small particulate depositions as well as films of (semi)volatile molecules. SIMS imaging reveals diverse and sometimes segregated chemical domains of hydrocarbons, inorganics, metals, and proteinaceous macromolecules. This work presents the first spatially resolved physical and chemical surface characterization of native environmental films, beginning a study of mechanisms by which these films form, persist, and mature in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic and Organometallic Chemistry at the Single-Molecule, -Particle, and -Molecular-Catalyst-Turnover Level by Fluorescence Microscopy

Mechanistic studies have historically played a key role in the discovery and optimization of reactions in organic and organometallic chemistry. However, even apparently simple organic and organometallic transformations may have surprisingly complicated multistep mechanisms, increasing the difficulty of extracting this mechanistic information. The resulting reaction intermediates often constitute a small fraction of the total reaction mixture, for example, creating a long-term analytical challenge of detection. This challenge is particularly pronounced in cases where the positions of intermediates on the reaction energy surface mean that they do not “build up” to the quantities needed for observation by traditional ensemble analytical tools. Thus, their existence and single-step elementary reactivity cannot be studied directly. New approaches for obtaining this otherwise-missing mechanistic information are therefore needed. Single-turnover, single-molecule, single-particle, and other subensemble fluorescence microscopy techniques are ideally suited for this role because of their sensitivity and spatiotemporal resolution. Inspired by the robust development of single-molecule fluorescence microscopy tools for studying enzyme catalysis, our laboratory has developed analogous fluorescence microscopy techniques to overcome mechanistic challenges in synthetic chemistry, with sensitivity as high as the single-complex, single-turnover, and single-molecule level. These techniques free the experimenter from the previous restriction that intermediates must “build up” to quantities needed for detection by ensemble analytical tools and are suited to systems where synchronization through flash photolysis or stopped flow would be inconvenient or inaccessible. In this process, the techniques transform certain previously “unobservable” intermediates and their elementary single-step reactivities into “observable” ones through sensitive and selective spectral handles. Our program has focused on imaging reactions in small-molecule, organic, and polymer synthetic chemistry with an accent on the reactivity of molecular transition metal complexes and catalysts. Our laboratory initiated studies in this area in 2008 with the imaging of individual palladium complexes that were tagged with spectator fluorophores. To enable imaging, we started with fluorophore selection and development, overcame challenges with imaging in organic solvents, and developed strategies compatible with air-sensitive chemistry and concentrations of reagents generally used in small-molecule synthesis. These studies grew to include characterization of previously unknown organometallic intermediates in the synthesis of organozinc reagents and the direct study of their elementary-step reactivity. The ability to directly observe this behavior generated predictive power for selecting salts that accelerated organozinc reagent formation in synthesis, including salts that had not yet been reported synthetically. In 2017 we also developed the first single-turnover imaging of molecular (chemo)catalysts, which through the technique’s spatiotemporal resolution revealed abruptly time-variable polymerization kinetics wherein molecular ruthenium ring-opening metathesis polymerization (ROMP) catalysts changed rates independently from other catalysts less than 1 μm away. Individual catalytic turnovers, each corresponding to one single-chain-elongation reaction arising from insertion of single ROMP or enyne monomers at individual Grubbs II molecular ruthenium catalysts, were spatiotemporally resolved as green flashes in growing polymers. In this work, we discuss the development of this technique from idea to application, including challenges overcome and strategies created to image synthetic organic and organometallic molecular chemistry at the highest levels of detection sensitivity. We also describe challenges not yet solved and provide an outlook for this growing field at the intersection of microscopy and synthetic/molecular chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5–10 GHz frequency range

We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme for studying high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes in the magnetization on short time scales and nanometer spatial dimensions is achieved by combining the excitation mechanism with single photon counting electronics that is locked to the synchrotron operation frequency. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with high spatial resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a ∼6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ∼0.1° amplitude at ∼9 GHz in a micrometer-sized cobalt strip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NuSTAR and IXO Missions

NuSTAR (Nuclear Spectroscopic Telescope Array) and IXO (International X-ray Observatory) missions are two of NASA X-ray missions for the coming decade. NuSTAR is a small explorer class mission that will for the first time use a multilayer-coated X-ray mirror assemblies to focus X-rays up to 80 keV. Among other objectives, its major science objective will be to conduct surveys to identify hard X-ray sources and to resolve the diffuse X-ray background. IXO, a collaborative mission of NASA, ESA, and JAXA, will be an observatory class mission. It will have a 3m in diameter X-ray mirror assembly with unprecedented photon collection area with a suite of focal plane detectors: a grating system, a large format CCD imaging system, a calorimeter, a polarimeter, and a high resolution and fast timing detector. It will significantly advance the spectroscopic studies of black holes, neutron stars, AGN, IGM, and nearly every other aspect of the X-ray universe. In this talk I will describe the instruments and scientific objectives of these two missions.

Zhang, William W.↗

ACCELERATING WAVES IN POLAR CORONAL HOLES AS SEEN BY EIS AND SUMER

We present EIS/Hinode and SUMER/SOHO observations of propagating disturbances detected in coronal lines in inter-plume and plume regions of a polar coronal hole. The observation was carried out on 2007 November 13 as part of the JOP196/HOP045 program. The SUMER spectroscopic observation gives information about fluctuations in radiance and on both resolved (Doppler shift) and unresolved (Doppler width) line-of-sight velocities, whereas EIS 40'' wide slot images detect fluctuations only in radiance but maximize the probability of overlapping field of view between the two instruments. From distance-time radiance maps, we detect the presence of propagating waves in a polar inter-plume region with a period of 15-20 minutes and a propagation speed increasing from 130 {+-} 14 km s{sup -1} just above the limb to 330 {+-} 140 km s{sup -1} around 160'' above the limb. These waves can be traced to originate from a bright region of the on-disk part of the coronal hole where the propagation speed is in the range of 25 {+-} 1.3 to 38 {+-} 4.5 km s{sup -1}, with the same periodicity. These on-disk bright regions can be visualized as the base of the coronal funnels. The adjacent plume region also shows the presence of propagating disturbances with the same range of periodicity but with propagation speeds in the range of 135 {+-} 18 to 165 {+-} 43 km s{sup -1} only. A comparison between the distance-time radiance map of the two regions indicates that the waves within the plumes are not observable (may be getting dissipated) far off-limb, whereas this is not the case in the inter-plume region. A correlation analysis was also performed to find out the time delay between the oscillations at several heights in the off-limb region, finding results consistent with those from the analysis of the distance-time maps. To our knowledge, this result provides first spectroscopic evidence of the acceleration of propagating disturbances in the polar region close to the Sun (within 1.2 R/R{sub sun}), which provides clues to the understanding of the origin of these waves. We suggest that the waves are likely either Alfvenic or fast magnetoacoustic in the inter-plume region and slow magnetoacoustic in the plume region. This may lead to the conclusion that inter-plumes are a preferred channel for the acceleration of the fast solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

RADIO SYNCHROTRON EMISSION FROM A BOW SHOCK AROUND THE GAS CLOUD G2 HEADING TOWARD THE GALACTIC CENTER

A dense ionized cloud of gas has been recently discovered to be moving directly toward the supermassive black hole, Sgr A*, at the Galactic center. In 2013 June, at the pericenter of its highly eccentric orbit, the cloud will be approximately 3100 Schwarzschild radii from the black hole and will move supersonically through the ambient hot gas with a velocity of v{sub p} Almost-Equal-To 5400 km s{sup -1}. A bow shock is likely to form in front of the cloud and could accelerate electrons to relativistic energies. We estimate via particle-in-cell simulations the energy distribution of the accelerated electrons and show that the non-thermal synchrotron emission from these electrons might exceed the quiescent radio emission from Sgr A* by a factor of several. The enhanced radio emission should be detectable at GHz and higher frequencies around the time of pericentric passage and in the following months. The bow shock emission is expected to be displaced from the quiescent radio emission of Sgr A* by {approx}33 mas. Interferometric observations could resolve potential changes in the radio image of Sgr A* at wavelengths {approx}< 6 cm.

79 ASTRONOMY AND ASTROPHYSICS↗

Status Report on Development of a Cask to Enable Pulsed Neutron Characterization of Irradiated Fuel

We present the design of a shielding cask that allows pulsed neutron characterization of irradiated fuel rodlets prior to their destructive examination in hot cells. The goal is to provide complementary and informative measurements that will inform subsequent hot cell PIE examinations by identifying typical and atypical regions with respect to microstructure, tomographic data, or isotope densities. Time-of-flight neutron diffraction has the potential to offer efficient, non-destructive and non-contact microstructural characterization of irradiated fuel pins with spatial resolution of 1 mm3 to 1 cm3 while for energy-resolved neutron imaging (and by extension tomography) a resolution of 100 μm was demonstrated. The potential results include crystallinity vs. amorphous volumes and microstructural information such as phase compositions and textures from the diffraction data as well as distances (e.g. pellet to cladding), cracks, and isotopic distributions of minor actinides, fission products as well as fission gas partial pressures e.g. in the plenum from energy resolved neutron imaging. The capability will identify regions of atypical behavior and provide cost effective bulk characterization of entire samples prior to destructive evaluation in hot cells. This effort is a collaboration between LANL, INL, ORNL, and UC Berkeley. A key facet of the initiative is the ability to cost effectively ship irradiated fuels from INL to the pulsed spallation neutron source at LANSCE. The irradiated fuel would be loaded in the custom designed cask (designated RaMHaM) at INL hot cells which then could be shipped in a BRR Type B shipment container between INL and LANL. No hot cell is required after the loading of the sample at INL in the pathway laid out in this report, greatly simplifying handling at LANL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The View From Out Here: The Solar System Planets as Exoplanet Analogs

As we begin to characterize planets orbiting other stars, one of the most important tools available to us is the collection of disk-integrated solar system observations. To date, these have been limited in how they match up with expected exoplanet observations in terms of wavelength, time, viewing geometry, and separations. The Interstellar Probe mission could push the boundaries of planetary science by providing a much-needed and unique dataset for the solar system viewed as an extrasolar system in advance of the next generation of ground and space-based telescopes. Viewing the solar system at large separations over a long period serves several purposes. It acts as a practical test directly analogous to exoplanet observations under realistic conditions, including such effects as zodiacal dust (e.g., Roberge et al., 2012). Secondly, it allows for both the validation of forward models (that is, simulating a planet and generating spectra) and retrievals (where some of the planetary properties are not known) (e.g., Robinson et al., 2011; Agarwal and Wettlaufer, 2017). Third, the mission pro le would be able to collect data at both high- and low-phase angles, which are lacking for most of the solar system planets (e.g., Mallama and Hilton, 2018). Lastly, the long duration of the proposed mission would allow not only snapshots, but time resolved observations using the same instrument, highlighting the dynamic nature of the planets (e.g., seasonality, storms). The planets need not be resolved to make these observations, which eases instrumentation requirements. Here, we show simulations of what an Interstellar Probe imager would see, improving on work that was part of a white paper submitted to the Planetary Science and Astrobiology Decadal Survey. The opportunity for multiple full orbits for most of the solar system planets, including a full phase curve of Saturn, is unique and worth pursuing during the development of the Interstellar Probe mission.

Chester Harman↗

3D velocity map imaging of electrons with TPX3CAM

In this report we demonstrate three-dimensional velocity map imaging of low energy electrons using a TPX3CAM, where the three-dimensional momentum information [$p_x, p_y, p_z$] is encoded in position and timing [x, y, t] of hits on the camera sensor. We make use of the camera sensor for the [x, y] information and a constant fraction discriminator and fast time to digital converter in the camera for the time information. We illustrate the capabilities of our apparatus by presenting above threshold ionization measurements of xenon, which produces well defined structures in the momentum resolved photoelectron yield.

79 ASTRONOMY AND ASTROPHYSICS↗

Multimodal Chemical Characterization of Brown Carbon in Atmosphere and Snowpack during SAIL Field Campaign Report

The main goal of this field project was to characterize the chemical and physical properties of light-absorbing particles (LAP) present in the atmosphere and snowpack. The specific field efforts included: 1) online measurement and sampling of light-absorbing particles using a Magee Scientific model AE33 aethalometer (AE33) and a time-resolved aerosol collector (TRAC); and 2) sampling of snowpack during observed events of LAP deposition on snow, confirmed by onsite U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility measurements and meteorological data. The ongoing research objectives of our follow-up sample and data analysis include: 1) Characterization of aerosol regimes and sources, identifying particle-type populations, mixing states, and atmospheric transformations based on correlative analysis of our detailed chemical imaging and chemical characterization measurements and real-time records from the second ARM Mobile Facility (AMF2) and other instruments available from the Surface Atmosphere Integrated Field Laboratory (SAIL) experiment; 2) Assessment of the optical and chemical properties of snowpack deposits to investigate how aerosol deposition influences snowpack lifetime.

54 ENVIRONMENTAL SCIENCES↗