Prospects for the expansion of standing wave ambient pressure photoemission spectroscopy to reactions at elevated temperatures

Standing wave ambient pressure photoemission spectroscopy (SWAPPS) is a promising method to investigate chemical and potential gradients across solid-vapor and solid-liquid interfaces under close-to-realistic environmental conditions, far away from high vacuum. Until now, these investigations have been performed only near room temperature, but for a wide range of interfacial processes, chief among them being heterogeneous catalysis, measurements at elevated temperatures are required. One concern in these investigations is the temperature stability of the multilayer mirrors, which generate the standing wave field. At elevated temperatures, degradation of the multilayer mirror due to, for example, interdiffusion between the adjacent layers, decreases the modulation of the standing wave field, thus rendering SWAPPS experiments much harder to perform. Here, we show that multilayer mirrors consisting of alternate B4C and W layers are stable at temperatures exceeding 600 °C and are, thus, promising candidates for future studies of surface and subsurface species in heterogeneous catalytic reactions using SWAPPS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emergent phenomena at oxide interfaces studied with standing-wave photoelectron spectroscopy

Emergent phenomena at complex-oxide interfaces have become a vibrant field of study in the past two decades due to the rich physics and a wide range of possibilities for creating new states of matter and novel functionalities for potential devices. The electronic-structural characterization of such phenomena presents a unique challenge due to the lack of direct yet nondestructive techniques for probing buried layers and interfaces with the required Ångstrom-level resolution, as well as element and orbital specificity. In this Review, we survey several recent studies wherein soft x-ray standing-wave photoelectron spectroscopy—a relatively newly developed technique—is used to investigate buried oxide interfaces exhibiting emergent phenomena such as metal-insulator transition, interfacial ferromagnetism, and two-dimensional electron gas. The advantages, challenges, and future applications of this methodology are also discussed.

36 MATERIALS SCIENCE↗

Effect of electrochemical cycling on microstructures of nanocomposite silicon electrodes using hyperpolarized 129 Xe and 7 Li NMR spectroscopy

The microstructural stability of composite electrodes during electrochemical cycling is critically important as it dictates the performance of Li-ion batteries. The issue becomes even more important for the high capacity alloying anode such as silicon that typically exhibits dramatic lithiation–delithiation-induced volume changes. The solid electrolyte interphase (SEI) layer formed on the active electrode surface has a profound effect on the overall microstructural stability of composite electrodes. An ideal SEI layer allows Li+ ions in and out of the electrode, but is an insulator to electrons, preventing the electrolyte from being further reduced. However, the SEI layers formed during initial lithiation may experience changes or degradation with subsequent cycling, adversely affecting the electrode performance. A combination of hyperpolarized 129 Xe and 7 Li nuclear magnetic resonance spectroscopies was applied to probe the microstructures of nanocomposite silicon electrodes at various stages of the lithiation–delithiation cycle. The results obtained from this study shed light on the degradation mechanism of nanocomposite Si electrodes upon electrochemical cycling and should prove useful in the effort to design more robust electrodes in the future.

36 MATERIALS SCIENCE↗

Superconducting platinum silicide analyzed by x-ray photoelectron spectroscopy

Platinum silicide has garnered increased attention due to its potential applications as a superconductor within silicon technology. In this work, we characterize a superconducting PtSi film using x-ray photoelectron spectroscopy with an Al K α excitation source. Survey spectra, Pt 5s, Pt 4f, Pt 4d, Pt 4p, Pt 4s, Si 2p, Si 2s, O 1s core levels, and the valence band spectrum were measured. In conclusion, this collection of high-quality core level spectra of a superconducting PtSi film provide reference data for this material, which often has a minimal native silicon oxide layer and overlapping Si and Pt core level peaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Analysis of hydrogen and lithium isotopes using Laser-Induced Breakdown Spectroscopy

The detection and quantification of hydrogen (1,2,3H) and lithium (6,7Li) isotopes are critical to several energy and defense application areas, including hydrogen storage, nuclear forensics, and safeguards/non-proliferation. In this context, laser-induced breakdown spectroscopy (LIBS) is very promising and it comes with certain advantages such as rapid detection, and standoff capability. Although LIBS provides experimental simplicity and is capable of detecting all elements in the periodic table in any phase (solid, liquid, or gas), there exist certain challenges for isotopic analyses of H and Li due to spectral broadening, the presence of closely spaced fine and hyperfine structures, and line distortion effects (e.g., self-absorption and self-reversal) present in laser-produced plasmas. This article reports recent developments in H and Li isotopic analysis using LIBS, and existing challenges.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Estimation of elastic properties of an additively manufactured lattice using resonant ultrasound spectroscopy

Development of improved approaches in the characterization of additively manufactured structures continues to be a topic of interest for the advanced manufacturing community. This article will investigate an approach using resonant ultrasound spectroscopy (RUS) to determine the effective elastic constants of an orthotropic lattice structure. The evaluation is performed on a cube shaped 316 L stainless steel test specimen, constructed using selective laser melting techniques. The approach uses RUS techniques in conjunction with the assumption that in the frequency regime of interest, the wavelength of the diagnostic ultrasound is greater than the discrete structural features of the unit cell of the lattice; thus, the AM structure can be treated as an anisotropic continuum with effective material properties and symmetry inherited from the unit cell. The RUS analysis estimates the nine elastic coefficients associated with orthotropic sample symmetry, which, in turn, are used to determine the elastic moduli and Poisson ratios. Current results show good agreement between experiments and modeled data. Comparisons to published results are also in good agreement, indicating the potential applicability of this characterization technique for estimating the linear elastic properties of innovative additive manufactured metal lattice structures.

36 MATERIALS SCIENCE↗

Enhanced resonant ultrasound spectroscopy for measurement of the elastic properties of multi-material systems

Understanding the elastic properties of materials is critical for their safe incorporation and predictable performance. Current methods of bulk elastic characterization often have notable limitations for in situ structural applications, with usage restricted to simple geometries and material distributions. To address these existing issues, this study sought to expand the capabilities of resonant ultrasound spectroscopy (RUS), an established nondestructive evaluation method, to include the characterization of isotropic multi-material samples. In this work, finite-element-based RUS analysis consisted of numerical simulations and experimental testing of composite samples comprised of material pairs with varying elasticity and density contrasts. Utilizing genetic algorithm inversion and mode matching, our results demonstrate that elastic properties of multi-material samples can be reliably identified within several percent of known or nominal values using a minimum number of identified resonance modes, given sample mass is held consistent. The accurate recovery of material properties for composite samples of varying material similarity and geometry expands the pool of viable samples for RUS and advances the method towards in situ inspection and evaluation.

36 MATERIALS SCIENCE↗

Enabling resonant ultrasound spectroscopy in high magnetic fields

Resonant ultrasound spectroscopy (RUS) is a powerful method to determine elastic constants with high accuracy and precision from a single measurement of the mechanical resonances of a sample. Conventionally, the quantitative extraction of elastic moduli with RUS assumes free boundary conditions which can often lead to the adoption of unstable sample positioning between ultrasonic transducers that is incompatible with extreme environments like high magnetic fields. We show that, under specific conditions, introducing a small amount of adhesive between a RUS sample and ultrasonic transducers introduces a perturbation to the free resonance condition which can be accounted for by a simple model. This means elastic constants can be determined to within the uncertainty of conventional RUS, but with significant improvements including sample stability and control of sample orientation. We demonstrate the efficacy of this approach with measurements on a range of materials including room temperature measurements on polycrystalline metals, temperature-dependent measurements of the structural phase transition in strontium titanate single crystals, and magnetic field-dependent measurements of magnetic phase transitions in gadolinium polycrystals up to 14 T.

47 OTHER INSTRUMENTATION↗

Auger spectroscopy beyond the ultra-short core-hole relaxation time approximation

Abstract We present a time-dependent computational approach to study Auger electron spectroscopy (AES) beyond the ultra-short core-hole relaxation time approximation and, as a test case, we apply it to the paradigmatic example of a one-dimensional Mott insulator represented by a half-filled Hubbard chain. The Auger spectrum is usually calculated by assuming that, after the creation of a core-hole, the system thermalizes almost instantaneously. This leads to a relatively simple analytical expression that uses the ground-state with a core-hole as a reference state and ignores all the transient dynamics related to the screening of the core-hole. In this picture, the response of the system can be associated to the pair spectral function. On the other hand, in our numerical calculations, the core hole is created by a light pulse, allowing one to study the transient dynamics of the system in terms of the pulse duration and in the non-perturbative regime. Time-dependent density matrix renormalization group calculations reveal that the relaxation process involves the creation of a polarization cloud of doublon excitations that have an effect similar to photo-doping. As a consequence, there is a leak of spectral weight to higher energies into what otherwise would be the Mott gap. For longer pulses, these excited states, mostly comprised of doublons, can dominate the spectrum. By changing the duration of the light-pulse, the entire screening process can be resolved in time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative Scanning Transmission Electron Microscopy for Materials Science: Imaging, Diffraction, Spectroscopy, and Tomography

Scanning transmission electron microscopy (STEM) is one of the most powerful characterization tools in materials science research. Due to instrumentation developments such as highly coherent electron sources, aberration correctors, and direct electron detectors, STEM experiments can examine the structure and properties of materials at length scales of functional devices and materials down to single atoms. STEM encompasses a wide array of flexible operating modes, including imaging, diffraction, spectroscopy, and 3D tomography experiments. This review outlines many common STEM experimental methods with a focus on quantitative data analysis and simulation methods, especially those enabled by open source software. The hope is to introduce both classic and new experimental methods to materials scientists and summarize recent progress in STEM characterization. The review also discusses the strengths and weaknesses of the various STEM methodologies and briefly considers promising future directions for quantitative STEM research.

36 MATERIALS SCIENCE↗

Heavy Element Spectroscopy in the Gas Phase

Actinides are inherently unstable and undergo nuclear decay processes with a concurrent release of energy. Consequently, they are used for nuclear power generation, nuclear weapons, and nuclear medicine. However, the radioactive decay processes also pose significant technological problems for the safe treatment and storage of spent nuclear materials. Cost-effective extraction of the actinides is the key first step in the remediation of nuclear waste, but the appropriate chemical means have yet to be determined. Our present understanding of the chemistry of actinides is limited, with the role of the 5f electrons posing a set of particularly challenging questions. The work reported here is focused on the use of electronic spectroscopy to probe the bonding of small molecules in the gas phase that contains thorium or uranium. Analyses of these data, carried out within the framework of ligand field theory, reveal clear evidence that the 5f electrons are spectators that retain their atomic metal ion character.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗

Monitoring the Caustic Dissolution of Aluminum Alloy in a Radiochemical Hot Cell Using Raman Spectroscopy

Chemical processing of highly radioactive materials commonly takes place in heavily shielded hot cells. The remote, real-time monitoring of chemical processing streams via optical spectroscopic techniques in hot cells may be particularly useful. Here in this paper, we describe the implementation of Raman spectroscopy and chemometric analysis to monitor the dissolution of aluminum-clad targets containing irradiated aluminum–neptunium oxide cermet pellets in caustic solutions in a hot cell environment. Partial least squares regression analysis was used to generate calibration models to quantify the concentration of dissolved aluminum, nitrate, and hydroxide in solutions within the radiochemical hot cell. This work explored a systematic approach to optimize a matrix of calibration standards using a D-optimal experimental design. The Design of Experiments-based regression model, in comparison to more traditional analytical approaches, was found to be the more practical method for building calibration models, with fewer samples, to obtain informative analytical data from Raman spectra.

36 MATERIALS SCIENCE↗

Trace Elemental Analysis of Bulk Thorium Using an Automated Separation–Inductively Coupled Plasma Optical Emission Spectroscopy Methodology

Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma–optical emission spectroscopy (ICP-OES). ICP-OES is a universal approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. Finally, while reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.