Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spatial data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

TRIGGER OF A BLOWOUT JET IN A SOLAR CORONAL MASS EJECTION ASSOCIATED WITH A FLARE

Using the multi-wavelength images and the photospheric magnetograms from the Solar Dynamics Observatory, we study the flare that was associated with the only coronal mass ejection (CME) in active region (AR) 12192. The eruption of a filament caused a blowout jet, and then an M4.0 class flare occurred. This flare was located at the edge of the AR instead of in the core region. The flare was close to the apparently “open” fields, appearing as extreme-ultraviolet structures that fan out rapidly. Due to the interaction between flare materials and “open” fields, the flare became an eruptive flare, leading to the CME. Then, at the same site of the first eruption, another small filament erupted. With the high spatial and temporal resolution Hα data from the New Vacuum Solar Telescope at the Fuxian Solar Observatory, we investigate the interaction between the second filament and the nearby “open” lines. The filament reconnected with the “open” lines, forming a new system. To our knowledge, the detailed process of this kind of interaction is reported for the first time. Then the new system rotated due to the untwisting motion of the filament, implying that the twist was transferred from the closed filament system to the “open” system. In addition, the twist seemed to propagate from the lower atmosphere to the upper layers and was eventually spread by the CME to the interplanetary space.

79 ASTRONOMY AND ASTROPHYSICS↗

Centre-excised X-ray luminosity as an efficient mass proxy for future galaxy cluster surveys

The cosmological constraining power of modern galaxy cluster catalogues can be improved by obtaining low-scatter mass proxy measurements for even a small fraction of sources. In the context of large upcoming surveys that will reveal the cluster population down to the group scale and out to high redshifts, efficient strategies for obtaining such mass proxies will be valuable. Here in this work, we use high-quality weak-lensing and X-ray mass estimates for massive clusters in current X-ray-selected catalogues to revisit the scaling relations of the projected, centre-excised X-ray luminosity (L ce ), which previous work suggests correlates tightly with total mass. Our data confirm that this is the case with Lce having an intrinsic scatter at fixed mass comparable to that of gas mass, temperature or YX. Compared to the other proxies, however, Lce is less susceptible to systematic uncertainties due to background modelling, and can be measured precisely with shorter exposures. This opens up the possibility of using L ce to estimate masses for large numbers of clusters discovered by new X-ray surveys (e.g. eROSITA) directly from the survey data, as well as for clusters discovered at other wavelengths with relatively short follow-up observations. We describe a simple procedure for making such estimates from X-ray surface brightness data, and comment on the spatial resolution required to apply this method as a function of cluster mass and redshift. Lastly, we also explore the potential impact of Chandra and XMM–Newton follow-up observations over the next decade on dark energy constraints from new cluster surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

High-fidelity simultaneous detection of a trapped-ion qubit register

Qubit state detection is an important part of a quantum computation. As number of qubits in a quantum register increases, it is necessary to maintain high fidelity detection to accurately measure the multi-qubit state. Here we present experimental demonstration of high-fidelity detection of a multi-qubit trapped ion register with average single qubit detection error of 4.2(1.5) ppm and a 4-qubit state detection error of 17(2) ppm, limited by the decay lifetime of the qubit, using a novel single-photon-sensitive camera with fast data collection, excellent temporal and spatial resolution, and low instrumental crosstalk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging the Solar Cell P-N Junction and Depletion Region Using Secondary Electron Contrast

We report on secondary electron (SE) images of cross-sectioned multicrystalline Si and GaAs/GaInP solar cell devices, focusing on quantifying the relationship between the apparent n{sup +}-p contrast and characteristic electronic features of the device. These samples allow us to compare the SE signal from devices which have very different physical characteristics: differing materials, diffused junction versus abrupt junction, heterojunction versus homojunction. Despite these differences, we find that the SE image contrast for both types of sample, and as a function of reverse bias across the diode, closely agrees with PC1D simulations of the bulk electrostatic potential in the device, accurately yielding the depletion edge and width. A spatial derivative of the SE data shows a local maximum at the metallurgical junction. Such data are valuable, for example, in studying the conformity of a diffused junction to the textured surface topography. These data also extend our understanding of the origin of the SE contrast.

14 SOLAR ENERGY↗

TU-F-BRF-04: Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System

Purpose: To develop a method for the fusion of 3D echocardiography and Scanning-Beam Digital X-ray (SBDX) fluoroscopy to assist with catheter device and soft tissue visualization during interventional procedures. Methods: SBDX is a technology for low-dose inverse geometry x-ray fluoroscopy that performs digital tomosynthesis at multiple planes in real time. In this study, transesophageal echocardiography (TEE) images were fused with SBDX images by estimating the 3D position and orientation (the “pose”) of the TEE probe within the x-ray coordinate system and then spatially transforming the TEE image data to match this pose. An initial pose estimate was obtained through tomosynthesis-based 3D localization of points along the probe perimeter. Position and angle estimates were then iteratively refined by comparing simulated projections of a 3D probe model against SBDX x-ray images. Algorithm performance was quantified by imaging a TEE probe in different known orientations and locations within the x-ray field (0-30 degree tilt angle, up to 50 mm translation). Fused 3D TEE/SBDX imaging was demonstrated by imaging a tissue-mimicking polyvinyl alcohol cylindrical cavity as a catheter was navigated along the cavity axis. Results: Detected changes in probe tilt angle agreed with the known changes to within 1.2 degrees. For a 50 mm translation along the source-detector axis, the detected translation was 50.3 mm. Errors for in-plane translations ranged from 0.1 to 0.9 mm. In a fused 3D TEE/SBDX display, the catheter device was well visualized and coincident with the device shadow in the TEE images. The TEE images portrayed phantom boundaries that were not evident under x-ray. Conclusion: Registration of soft tissue anatomy derived from TEE imaging and device imaging from SBDX x-ray fluoroscopy is feasible. The simultaneous 3D visualization of these two modalities may be useful in interventional procedures involving the navigation of devices to soft tissue anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-BRF-01: The Promise and Potential Pitfalls of Deformable Image Registration in Clinical Practice

Accurate and robust deformable image registration (DIR) is a key enabling technique in the clinical realization of two approaches for advancing radiation therapy treatment efficacy: adaptive radiation therapy and treatment response assessment. Currently there are a wide variety of DIR methods including the categories of splines, optical/diffusion, free-form, and biomechanical algorithms. All methods aim to translate information between image sets (including multi-modal data) in the presence of spatial deformation of tissues. However, recent research has shown that different DIR algorithms can yield substantially different results for the same reference deformation, and that DIR performance can be site and application dependent. As a result, errors can occur, and subsequent patient treatment can be compromised. There is a clear need for greater understanding of appropriate use of DIR techniques, as well as effective methods of validation, evaluation, and improvement. In this session, we will review the state-of-the-art concerning DIR development, clinical application, and performance evaluation. Novel DIR methods and evaluating technologies will be reviewed. Learning Objectives: To understand the underlying principles and physics of current DIR techniques To explore potential clinical applications and areas of high impact for DIR To investigate sources of uncertainty, appropriate usage, and methods for validating and evaluating DIR performance.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-00: MR Basics II

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-01: MR Imaging for Treatment Planning: What Every Physicist Should Know

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

Moessbauer studies of two-electron centers with negative correlation energy in crystalline and amorphous semiconductors

The results of the study of donor U{sup -}-centers of tin and germanium in lead chalcogenides by Moessbauer emission spectroscopy are discussed. The published data regarding the identification of amphoteric U{sup -}-centers of tin in glassy binary arsenic and germanium chalcogenides using Moessbauer emission spectroscopy, and in multicomponent chalcogenide glasses using Moessbauer absorption spectroscopy are considered. Published data concerning the identification of two-atom U{sup -}-centers of copper in lattices of semimetal copper oxides by Moessbauer emission spectroscopy are analyzed. The published data on the detection of spatial inhomogeneity of the Bose-Einstein condensate in superconducting semiconductors and semimetal compounds, and on the existence of the correlation between the electron density in lattice sites and the superconducting transition temperature are presented. The principal possibility of using Moessbauer U{sup -}-centers as a tool for studying the Bose-Einstein condensation of electron pairs during the superconducting phase transition in semiconductors and semimetals is considered.

36 MATERIALS SCIENCE↗

Operational Forecasting of Induced Seismicity

Operational Forecasting of Induced Seismicity (ORION) is an open-source toolkit developed as part of the US Department of Energy SMART and NRAP programs. ORION is designed to help both expert and non-expert users understand the seismic hazard at a site. This tool analyzes how the seismic hazard evolves during injection of fluid, and can be used to identify potential mitigation strategies for observed or forecasted seismic activity. ORION is built using Python, and has an optional GUI where users can easily configure model parameters, evaluate temporal and spatial forecasts, and inspect key data (seismicity, fluid injection, pressure models, etc.).

Kroll, Kayla↗

Development of a TSR-based method for understanding structural relationships of cofactors and local environments in photosystem I

All chemical forms of energy and oxygen on Earth are generated via photosynthesis where light energy is converted into redox energy by two photosystems (PS I and PS II). There is an increasing number of PS I 3D structures deposited in the Protein Data Bank (PDB). The Triangular Spatial Relationship (TSR)-based algorithm converts 3D structures into integers (TSR keys). A comprehensive study was conducted, by taking advantage of the PS I 3D structures and the TSR-based algorithm, to answer three questions: (i) Are electron cofactors including P700, A -1 and A 0 , which are chemically identical chlorophylls, structurally different? (ii) There are two electron transfer chains (A and B branches) in PS I. Are the cofactors on both branches structurally different? (iii) Are the amino acids in cofactor binding sites structurally different from those not in cofactor binding sites? The key contributions and important findings include: (i) a novel TSR-based method for representing 3D structures of pigments as well as for quantifying pigment structures was developed; (ii) the results revealed that the redox cofactor, P700, are structurally conserved and different from other redox factors. Similar situations were also observed for both A -1 and A 0 ; (iii) the results demonstrated structural differences between A and B branches for the redox cofactors P700, A -1 , A 0 and A 1 as well as their cofactor binding sites; (iv) the tryptophan residues close to A 0 and A 1 are structurally conserved; (v) The TSR-based method outperforms the Root Mean Square Deviation (RMSD) and the Ultrafast Shape Recognition (USR) methods. The structural analyses of redox cofactors and their binding sites provide a foundation for understanding the unique chemical and physical properties of each redox cofactor in PS I, which are essential for modulating the rate and direction of energy and electron transfers.

59 BASIC BIOLOGICAL SCIENCES↗

Temperature and heat flux datasets of a complex object in a fire plume for the validation of fire and thermal response codes.

It is necessary to improve understanding and develop temporally- and spatially-resolved integral scale validation data of the heat flux incident to a complex object in addition to measuring the thermal response of said object located within the fire plume for the validation of the SIERRA/FUEGO/SYRINX fire and SIERRA/CALORE codes. To meet this objective, a complex calorimeter with sufficient instrumentation to allow validation of the coupling between FUEGO/SYRINX/CALORE has been designed, fabricated, and tested in the Fire Laboratory for Accreditation of Models and Experiments (FLAME) facility. Validation experiments are specifically designed for direct comparison with the computational predictions. Making meaningful comparison between the computational and experimental results requires careful characterization and control of the experimental features or parameters used as inputs into the computational model. Validation experiments must be designed to capture the essential physical phenomena, including all relevant initial and boundary conditions. This report presents the data validation steps and processes, the results of the penlight radiant heat experiments (for the purpose of validating the CALORE heat transfer modeling of the complex calorimeter), and the results of the fire tests in FLAME.

99 GENERAL AND MISCELLANEOUS↗

Aircraft Field Exercise to Develop Multi-Spectral and Infrared Imaging for CTBT On-Site Inspections

The Comprehensive Test Ban Treaty (CTBT) permits Multi-Spectral and InfraRed Imaging (MSIR) to be performed as part of an On-Site Inspection (OSI) for the purpose of reducing the search area for the location of a possible underground nuclear explosion (UNE). Dedicated airborne MSIR measurements have not been made in conjunction with historical or recent UNE’s. Satellite data has been used to show that MSIR observables can be used to reduce the search area, but the satellite data do not have the spatial resolution or spectral and thermal capabilities desired to fully characterize the MSIR observables. Consequently, there is insufficient information currently available to confidently specify an MSIR instrument to be used on an Additional Overflight as part of an OSI. The potential MSIR observables are known, but not well characterized. The possibility of using airborne MSIR measurements to characterize some of those observables has been assessed here for a variety of field exercise scenarios. The main challenge in making aircraft measurements is to have confidence that the field conditions will accurately reproduce the MSIR observable compared to a UNE. The four types of events expected to generate relevant MSIR observables are (1) underground coal fires, (2) road traffic measurements, (3) underground mining operations, and (4) certain carefully staged explosions, such as the Source Physics Experiment.

58 GEOSCIENCES↗

NIF S600D Snout Final Design Review (FDR) Report

The S600D is a one or two channel mirror spectrometer which will provide temporal and spatial soft x-ray data in a single NIF shot. It mounts to the existing DIM Imaging Streak Camera (DISC) using the standard NIF kinematic mount design. LLE and LLNL each have responsibilities for the snout. The Laboratory for Laser Energetics (LLE) is subcontracted to design, fabricate, and align the S600D Snout at the OMEGA Laser facility in Rochester, NY before delivery to LLNL. The Snout consists of the Mirror Mount, Kinematic interface to DISC, Slit mount, and filter pack mount. Lawrence Livermore National Laboratory (LLNL) is responsible to fabricate and deliver the Mirror substrates and coatings, Pinhole slits and collimators, Filter material, and Image plates. LLNL is also responsible for the Requirements Definition, Concept of Operations, Debris and Shrapnel analysis, Stakeholder reviews and Integration in the NIF Facility.

42 ENGINEERING↗

Development of Software Defined Radio Protocol for Acoustic Communication on Pipes

Nuclear Science Engineering Division at Argonne has been developing a new method of transmitting information via acoustic waves on pipes in a nuclear facility. This method provides the capability to communicate information from within the containment building under the conditions of total power outage following a severe accident. Compared to traditional RF communications, acoustic communications allows for signal transmission across thick concrete barriers, and better information security due to spatial confinement of the signal. Data of interest consists of sensor readings, voice, and images. Transmission of images is most challenging because corruption of the header string might render the reconstructed image unreadable.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NOW-23: the 2023 National Offshore Wind Data Set

In this report, we present the latest wind resource data specifically tailored for offshore regions in the United States. The data set, known as the 2023 National Offshore Wind data set (NOW-23), has been developed by the National Renewable Energy Laboratory (NREL) and its partners, and surpasses the previous resource data set, the Wind Integration National Dataset (WIND) Toolkit, which was released approximately ten years ago, in its offshore component. The WIND Toolkit has been widely utilized by stakeholders involved in wind resource assessments across the continental United States. However, with significant advancements in numerical weather prediction modeling over the past decade, the NOW-23 data set incorporates the latest research and development progress to provide stakeholders with an updated and cutting-edge resource for offshore wind analysis. The NOW-23 data set is created using the Weather Research and Forecasting (WRF) model and its output is available, as for its predecessor, at 5-minute time resolution and 2-kilometer horizontal spatial resolution. However, the NOW-23 data set improves upon the WIND Toolkit through: 1. A modeling period of at least 20 years (and as long as 23 years in selected regions), starting in 2000 (compared to the 7-year 2007–2013 modeling period in the WIND Toolkit). 2. For several offshore regions, a region-specific sensitivity analysis, driven by an ensemble of WRF simulations, to assess the most adequate region-specific WRF setup. 3. An updated WRF model, from Version 3.4 used in the WIND Toolkit to Version 4.2.1 used for the NOW-23 data set, which incorporates significant research advancements. 4. The use of the state-of-the-art reanalysis product ERA5 (which supersedes the older ERA-Interim used in the WIND Toolkit) to provide atmospheric forcing at the WRF domain boundaries. Figure 1 shows the NOW-23 mean wind speed at 160 m above sea level (asl), which we use as proxy for hub-height of a commercial offshore wind turbine in this report across all regions.

17 WIND ENERGY↗

Hydrological connectivity: a review and emerging strategies for integrating measurement, modeling, and management

This review synthesizes methods for measuring, modeling, and managing hydrologic connectivity, offering pathways to improve practices and address environmental challenges (e.g., climate change) and sustainability. As a key driver of water movement and nutrient cycling, hydrologic connectivity influences flood mitigation, water quality regulation, and biodiversity conservation. However, traditional field-based methods (e.g., dye tracing), indirect measurements (e.g., runoff analysis), and remote sensing techniques (e.g., InSAR) often struggle to capture the complexity of catchment-scale interactions. Similarly, modeling approaches—including process-based and percolation theory-based models, graph theory, and entropy-based metrics—face limitations in fully representing these interconnected processes. Both modeling and measurement techniques are constrained by inadequate spatial and temporal coverage, high data demands, computational complexity, and difficulties in representing subsurface connectivity. Subsequently, we critique current management practices that prioritize isolated variables (e.g., streamflow, sediment transport) over system-wide strategies and emphasize the need for adaptive, connectivity-based approaches in water resource planning and restoration. Moving forward, we highlight the importance of interdisciplinary collaboration, technological innovations (e.g., AI-driven modeling, real-time monitoring), and integrated frameworks to improve connectivity measurement, modeling, and adaptive management to restore fragmented hydrologic networks. This integrated approach sets the stage for transformative water resource management, fostering proactive policy development and stakeholder engagement.

Dwivedi, Dipankar↗