Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Selection optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Systems and methods for hierarchical multi-objective optimization

A method for optimizing objective functions can include selecting an objective function based at least on a hierarchy, applying parameters to the objective function to generate an output, responsive to the output not satisfying a tolerance condition, assigning a penalty to the set of parameters and evaluating a convergence condition using the set of parameters and the penalty, responsive to the output satisfying the tolerance condition, evaluating an additional objective function using the parameters in an order corresponding to the hierarchy or evaluating the convergence condition responsive to the selected objective function being a final objective function, modifying the set of parameters using a genetic algorithm responsive to the set of parameters not satisfying the convergence condition, and outputting the set of parameters responsive to the set of parameters satisfying the convergence condition.

Chan, Henry↗

Preprocessing Moist Lignocellulosic Biomass for Biorefinery Feedstocks

Biomass preprocessing is one of the primary operations in the feedstock assembly system of a lignocellulosic biorefinery. Preprocessing is generally accomplished using industrial grinders to format biomass materials into a suitable biorefinery feedstock for conversion to ethanol and other bioproducts. Many factors affect machine efficiency and the physical characteristics of preprocessed biomass. For example, moisture content of the biomass as received from the point of production has a significant impact on overall system efficiency and can significantly affect the characteristics (particle size distribution, flowability, storability, etc.) of the size-reduced biomass. Many different grinder configurations are available on the market, each with advantages under specific conditions. Ultimately, the capacity and/or efficiency of the grinding process can be enhanced by selecting the grinder configuration that optimizes grinder performance based on moisture content and screen size. This paper discusses the relationships of biomass moisture with respect to preprocessing system performance and product physical characteristics and compares data obtained on corn stover, switchgrass, and wheat straw as model feedstocks during Vermeer HG 200 grinder testing. During the tests, grinder screen configuration and biomass moisture content were varied and tested to provide a better understanding of their relative impact on machine performance and the resulting feedstock physical characteristics and uniformity relative to each crop tested.

09 BIOMASS FUELS↗

Optimizing Normal Tissue Sparing in Ion Therapy Using Calculated Isoeffective Dose for Ion Selection

Purpose: To investigate how the selection of ion type affects the calculated isoeffective dose to the surrounding normal tissue as a function of both normal tissue and target tissue {alpha}/{beta} ratios. Methods and Materials: A microdosimetric biologic dose model was incorporated into a Geant4 simulation of parallel opposed beams of protons, helium, lithium, beryllium, carbon, and neon ions. The beams were constructed to give a homogeneous isoeffective dose to a volume in the center of a water phantom for target tissues covering a range of cobalt equivalent {alpha}/{beta} ratios of 1-20 Gy. Concomitant normal tissue isoeffective doses in the plateau of the ion beam were then compared for different ions across the range of normal tissue and target tissue radiosensitivities for a fixed isoeffective dose to the target tissue. Results: The ion type yielding the optimal normal tissue sparing was highly dependent on the {alpha}/{beta} ratio of both the normal and the target tissue. For carbon ions, the calculated isoeffective dose to normal tissue at a 5-cm depth varied by almost a factor of 5, depending on the {alpha}/{beta} ratios of the normal and target tissue. This ranges from a factor of 2 less than the isoeffective dose of a similar proton treatment to a factor of 2 greater. Conclusions: No single ion is optimal for all treatment scenarios. The heavier ions are superior in cases in which the {alpha}/{beta} ratio of the target tissue is low and the {alpha}/{beta} ratio of normal tissue is high, and protons are superior in the opposite circumstances. Lithium and beryllium appear to offer dose advantages similar to carbon, with a considerably lower normal tissue dose when the {alpha}/{beta} ratio in the target tissue is high and the {alpha}/{beta} ratio in the normal tissue is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ensemble variational Fokker-Planck methods for data assimilation

Particle flow filters solve Bayesian inference problems by smoothly transforming a set of particles into samples from the posterior distribution. Particles move in state space under the flow of an McKean-Vlasov-Itˆo process. This work introduces the Variational Fokker-Planck (VFP) framework for data assimilation, a general approach that includes previously known particle flow filters as special cases. The McKean-Vlasov-Itˆo process that transforms particles is defined via an optimal drift that depends on the selected diffusion term. It is established that the underlying probability density - sampled by the ensemble of particles - converges to the Bayesian posterior probability density. For a finite number of particles the optimal drift contains a regularization term that nudges particles toward becoming independent random variables. Based on this analysis, we derive computationally-feasible approximate regularization approaches that penalize the mutual information between pairs of particles, and avoid particle collapse. Moreover, the diffusion plays a role akin to a particle rejuvenation approach that aims to alleviate particle collapse. The VFP framework is very flexible. Different assumptions on prior and intermediate probability distributions can be used to implement the optimal drift, and localization and covariance shrinkage can be applied to alleviate the curse of dimensionality. A robust implicit-explicit method is discussed for the efficient integration of stiff McKean- Vlasov-Itˆo processes. Here, the effectiveness of the VFP framework is demonstrated on three progressively more challenging test problems, namely the Lorenz ’63, Lorenz ’96 and the quasi-geostrophic equations.

97 MATHEMATICS AND COMPUTING↗

Simplified Two-Stage Model Predictive Control for a Hybrid Multilevel Converter With Floating H-Bridge

This paper proposes a simplified two-stage model predictive control (ST-MPC) for a hybrid multilevel converter, which is an active-neutral-point-clamped converter with floating H-bridge (ANPC-H). The objective of the first stage is to select the voltage vector that has the optimal current tracking performance by using a novel geometrical positioning approach in the complex plane. The second stage selects the best switching state among all the available switching states that belong to the same voltage vector obtained in the first stage, to balance dc capacitor voltages and reduce the common mode voltage. The proposed ST-MPC can dramatically reduce the computational burden and ensure the best current tracking by the two-stage structure, such that the execution time is much shorter compared with the conventional MPC. In addition, the geometrical positioning approach in the first stage is generic and can be applicable for any multilevel converters with N-level output; thus, this ST-MPC can be applied for both sevenand nine-level operation of the hybrid ANPC-H converter under different dc voltage ratios. Both simulation results and experimental results obtained on a silicon carbide hybrid ANPC-H converter prototype validate the feasibility and effectiveness of the proposed ST-MPC strategy.

42 ENGINEERING↗

Optimal primitive reference frames

We consider the smallest possible directional reference frames allowed and determine the best one can ever do in preserving quantum information in various scenarios. We find that for the preservation of a single spin state, two orthogonal spins are optimal primitive reference frames; and in a product state, they do approximately 22% as well as an infinite-sized classical frame. By adding a small amount of entanglement to the reference frame, this can be raised to 2(2/3){sup 5}=26%. Under the different criterion of entanglement preservation, a very similar optimal reference frame is found; however, this time it is for spins aligned at an optimal angle of 87 deg. In this case 24% of the negativity is preserved. The classical limit is considered numerically, and indicates under the criterion of entanglement preservation, that 90 deg. is selected out nonmonotonically, with a peak optimal angle of 96.5 deg. for L=3 spins.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trends and limits of CO 2 capture in solid and liquid sorbents at standard conditions

Carbon capture and storage (CCS) plays a critical role in achieving climate change mitigation targets, offering a pathway to decarbonize power generation, industrial processes, and heat production while addressing atmospheric CO 2 removal. While CCS technologies are technically advanced, the widespread adoption of 100 % CO 2 capture capacities such as 1 mol of CO 2 /mol of material and 1 g CO 2 /g storage (targeted by the DARPA, Defense Sciences Office, USA Govt.) has raised questions about the feasibility of achieving higher capture capacities. In the context of limiting global warming to 1.5°C, reaching 100 % CO 2 capture capacity is increasingly necessary, with residual emissions requiring complementary carbon dioxide removal (CDR) technologies. This review exclusively focuses on the CO 2 capture capacities of various sorbents under standard conditions, using different evaluation metrics. This study explores the performance of solid and liquid sorbents under standard conditions, analyzing factors including surface area, pore structure, solvent type, and functionalization to identify materials optimized for industrial-scale CCS applications. Emerging sorbents, including ILs, MOFs, COFs, POPs, DES, RCC, hybrid materials, and reactive sorbents, offer significant potential for enhanced selectivity and energy-efficient regeneration. Through a systematic assessment of gravimetric, volumetric, and molar capacities, the study provides insights into material efficiencies and trade-offs, offering guidance on optimizing sorbent selection for specific applications. The research advances understanding of scalable CCS technologies, contributing to global efforts to achieve net-zero emissions and address the pressing challenge of climate change.

Absorption↗

Bayesian modeling of inconsistent plastic response due to material variability

The advent of fabrication techniques such as additive manufacturing has focused attention on the considerable variability of material response due to defects and other microstructural aspects. This variability motivates the development of an enhanced design methodology that incorporates inherent material variability to provide robust predictions of performance. In this work, we develop plasticity models capable of representing the distribution of mechanical responses observed in experiments using traditional plasticity models of the mean response and recently developed uncertainty quantification (UQ) techniques. To account for material response variability through variations in physical parameters, we adapt a recent Bayesian embedded modeling error calibration technique. We use Bayesian model selection to determine the most plausible of a variety of plasticity models and the optimal embedding of parameter variability. To expedite model selection, we develop an adaptive importance-sampling-based numerical integration scheme to compute the Bayesian model evidence. In conclusion, we demonstrate that the new framework provides predictive realizations that are superior to more traditional ones, and how these UQ techniques can be used in model selection and assessing the quality of calibrated physical parameters.

36 MATERIALS SCIENCE↗

Characterization of a 2D soft x-ray tomography camera with discrimination in energy bands

A gas detector with a 2D pixel readout is proposed for a future soft x-ray (SXR) tomography with discrimination in energy bands separately per pixel. The detector has three gas electron multiplier foils for the electron amplification and it offers the advantage, compared with the single stage, to be less sensitive to neutrons and gammas. The energy resolution and the detection efficiency of the detector have been accurately studied in the laboratory with continuous SXR spectra produced by an electronic tube and line emissions produced by fluorescence (K, Fe, and Mo) in the range of 3-17 keV. The front-end electronics, working in photon counting mode with a selectable threshold for pulse discrimination, is optimized for high rates. The distribution of the pulse amplitude has been indirectly derived by means of scans of the threshold. Scans in detector gain have also been performed to assess the capability of selecting different energy ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-206-08: How Should Focal Spot Be Chosen for Optimized CT Imaging with Dose Modulation?

Purpose: To choose the preferred focal spot for achieving optimized CT image quality with balanced tube heating considerations. Methods: An anthropomorphic pelvic phantom was scanned using a GE Discovery CT750 HD at 120 and 140kVp, 0.8s rotation time, and pitch of 0.984. “Smart mA” was enabled to simulate a routine abdomen–pelvis CT scan. Permissible mA values at 120 and 140 kVp were obtained from the Serial Load Rating table (for mimicking a busy CT clinical operation) in the scanner Technical Reference Manual. At each kVp station and two Noise Index levels, the mA Upper Limit was set above/below the permissible mA values. Scanned mA values and focal spot (FS) used were obtained from the DICOM header of each image, and the FS-mA relationship was analyzed. For visual confirmation beyond recorded FS information, a CatPhan with a fat-ring attached for mimicking patient size/shape was scanned at 120kVp. A group of radiologists/physicists compared a pair of CatPhan images qualitatively. Lastly, a number of patient cases were evaluated to confirm the FS-mA relationship. Results: When preset Upper Limit values were above the permissible mA values, the Large FS (labeled 1.2) was used in scans, even if the maximum scanned mA values were much lower than the permissible values at both 120 and 140 kVp. Otherwise the Small FS (labeled 0.7) was used. Visual evaluation of the high contrast module of CatPhan and additional analysis of patient cases further confirmed that the preset Upper Limit determines which focal spot is to be used, not the actual maximum mA value to be scanned. Conclusion: Specific FS can be selected by setting up appropriate mA Upper Limit in a protocol. CT protocols could be optimized by selecting appropriate FS for improving patient image quality, especially benefiting the small size and pediatric patients.

60 APPLIED LIFE SCIENCES↗

CYCLE MODELING AND OPTIMIZATION OF AN INTEGRALLY GEARED sCO2 COMPANDER

This paper presents the selection of a system configuration and off-design control method for an integrally geared compander based on cycle modeling and optimization. The goal of the cycle modeling was to determine a cycle configuration that would reach an efficiency of 50% at design conditions and to optimize off-design control to maintain high efficiencies. The compander is being developed for use in a concentrated solar power supercritical carbon dioxide power plant with expected turbine inlet temperatures of 705°C and utilizing dry cooling leading to compressor inlet temperature varying between 35°C and 55°C. The compander is unique as it consists of eight turbomachinery stages on four pinions all being driven by a single bull gear. The separate stages offer the opportunity to consider a variety of flow splits and cycle configurations including intercooling and multiple stages of reheat. Cycle modeling was conducted in two stages: on-design and off-design. On-design modeling was simulated with all components operating at their design point. This was used to compare the performance of different cycle configurations and design temperatures. Off-design modeling was then performed to investigate the temperature dependence of the cycle efficiency and power output and to develop a control strategy. Strategies considered and discussed include: turbine bypass, compressor recycle, inlet guide vanes, and inventory control. To determine the best operating conditions for each configuration and control strategy, a genetic algorithm was implemented to optimize the cycle performance across the range of operating temperatures being considered. The final selection of cycle configuration, design temperature and control strategy is also presented.

bennett, jeffrey↗

A multicriteria framework with voxel-dependent parameters for radiotherapy treatment plan optimization

Purpose: To establish a new mathematical framework for radiotherapy treatment optimization with voxel-dependent optimization parameters. Methods: In the treatment plan optimization problem for radiotherapy, a clinically acceptable plan is usually generated by an optimization process with weighting factors or reference doses adjusted for a set of the objective functions associated to the organs. Recent discoveries indicate that adjusting parameters associated with each voxel may lead to better plan quality. However, it is still unclear regarding the mathematical reasons behind it. Furthermore, questions about the objective function selection and parameter adjustment to assure Pareto optimality as well as the relationship between the optimal solutions obtained from the organ-based and voxel-based models remain unanswered. To answer these questions, the authors establish in this work a new mathematical framework equipped with two theorems. Results: The new framework clarifies the different consequences of adjusting organ-dependent and voxel-dependent parameters for the treatment plan optimization of radiation therapy, as well as the impact of using different objective functions on plan qualities and Pareto surfaces. The main discoveries are threefold: (1) While in the organ-based model the selection of the objective function has an impact on the quality of the optimized plans, this is no longer an issue for the voxel-based model since the Pareto surface is independent of the objective function selection and the entire Pareto surface could be generated as long as the objective function satisfies certain mathematical conditions; (2) All Pareto solutions generated by the organ-based model with different objective functions are parts of a unique Pareto surface generated by the voxel-based model with any appropriate objective function; (3) A much larger Pareto surface is explored by adjusting voxel-dependent parameters than by adjusting organ-dependent parameters, possibly allowing for the generation of plans with better trade-offs among different clinical objectives. Conclusions: The authors have developed a mathematical framework for radiotherapy treatment optimization using voxel-based parameters. The authors can improve the plan quality by adjusting voxel-based weighting factors and exploring the unique and large Pareto surface which include all the Pareto surfaces that can be generated by organ-based model using different objective functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comprehensive formulation for volumetric modulated arc therapy planning

Purpose: Volumetric modulated arc therapy (VMAT) is a widely employed radiation therapy technique, showing comparable dosimetry to static beam intensity modulated radiation therapy (IMRT) with reduced monitor units and treatment time. However, the current VMAT optimization has various greedy heuristics employed for an empirical solution, which jeopardizes plan consistency and quality. The authors introduce a novel direct aperture optimization method for VMAT to overcome these limitations. Methods: The comprehensive VMAT (comVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term to penalize the difference between the optimized dose and the prescribed dose, as well as an anisotropic total variation term to promote piecewise continuity in the fluence maps, preparing it for direct aperture optimization. A level set function was used to describe the aperture shapes and the difference between aperture shapes at adjacent angles was penalized to control MLC motion range. A proximal-class optimization solver was adopted to solve the large scale optimization problem, and an alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc comVMAT plans, utilizing 180 beams with 2° angular resolution, were generated for a glioblastoma multiforme case, a lung (LNG) case, and two head and neck cases—one with three PTVs (H&N{sub 3PTV}) and one with foue PTVs (H&N{sub 4PTV})—to test the efficacy. The plans were optimized using an alternating optimization strategy. The plans were compared against the clinical VMAT (clnVMAT) plans utilizing two overlapping coplanar arcs for treatment. Results: The optimization of the comVMAT plans had converged within 600 iterations of the block minimization algorithm. comVMAT plans were able to consistently reduce the dose to all organs-at-risk (OARs) as compared to the clnVMAT plans. On average, comVMAT plans reduced the max and mean OAR dose by 6.59% and 7.45%, respectively, of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N{sub 3PTV} case. PTV coverages measured by D95, D98, and D99 were within 0.25% of the prescription dose. By comprehensively optimizing all beams, the comVMAT optimizer gained the freedom to allow some selected beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel nongreedy VMAT approach simultaneously optimizes all beams in an arc and then directly generates deliverable apertures. The single arc VMAT approach thus fully utilizes the digital Linac’s capability in dose rate and gantry rotation speed modulation. In practice, the new single VMAT algorithm generates plans superior to existing VMAT algorithms utilizing two arcs.

60 APPLIED LIFE SCIENCES↗

Ideal isotropic auxetic networks from random networks

We design and create isotropically auxetic networks with Poisson's ratio close to −1 in experiments. To achieve this, we selectively prune bonds from disordered networks, and then optimize the properties of individual bonds and nodes.

Reid, Daniel R.↗

Current capabilities of the residual stress diffractometer at the high flux isotope reactor

The engineering diffractometer 2nd Generation Neutron Residual Stress Facility (NRSF2) at the Oak Ridge National Laboratory’s High Flux Isotope Reactor was built specifically for the mapping of residual strains. NRSF2 is optimized to investigate a wide range of engineering materials by providing the user a selection of monochromatic neutron wavelengths to maintain the selected Bragg reflection near 2θ = 90°, which is the optimal scattering geometry for strain mapping. Here in this work, details of the instrument configuration and operation are presented, and considerations for experimental planning are also discussed. Selected examples of recent residual stress work completed with NRSF2 are presented to highlight capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objective and algorithm considerations when optimizing the number and placement of turbines in a wind power plant

Abstract. Optimizing turbine layout is a challenging problem that has been extensively researched in the literature. However, optimizing the number of turbines within a given boundary has not been studied as extensively and is a difficult problem because it introduces discrete design variables and a discontinuous design space. An essential step in performing wind power plant layout optimization is to define the objective function, or value, that is used to express what is valuable to a wind power plant developer, such as annual energy production, cost of energy, or profit. In this paper, we demonstrate the importance of selecting the appropriate objective function when optimizing a wind power plant in a land-constrained site. We optimized several different wind power plants with different wind resources and boundary sizes. Results show that the optimal number of turbines varies drastically depending on the objective function. For a simple, one-dimensional, land-based scenario, we found that a wind power plant optimized for minimal cost of energy produced just 72 % of the profit compared to the wind power plant optimized for maximum profit, which corresponded to a loss of about USD 2 million each year. This paper also compares the performance of several different optimization algorithms, including a novel repeated-sweep algorithm that we developed. We found that the performance of each algorithm depended on the number of design variables in the problem as well as the objective function.

17 WIND ENERGY↗

A Comparative Study of Electrical Double Layer Effects for CO Reduction Reaction Kinetics

Solvation models describe how the interactions between the solutes and solvents affect the reactivity and selectivity in electrochemical processes. In this study, we developed a framework for evaluating the effects of applied potential and electrical double layer on CO reduction (COR), comparing fully explicit, implicit, and hybrid solvation models at the standard hydrogen electrode (SHE) scale. We analyzed all crucial intermediates leading to the production of C 1 and C 2 products and found good agreement across these models. Some notable differences were observed in the implicit description of *C and *CO adsorption at higher overpotentials and overall trends in the adsorption energies within the hybrid model. Using this unified SHE framework, we built comparable microkinetic models for COR kinetics and rates. Despite small differences in thermodynamics, solvation-model-based microkinetic simulations showed good agreement for onset potentials against the benchmark experiment. Only qualitative difference was observed for C 1+ versus hydrogen evolution at high overpotentials for the implicit model. Finally, we constructed a generalized C 2 selectivity map in descriptor space (U SHE , ΔG electrolyte CO ), which highlights the limitations of a copper-based COR catalyst and guides the search for optimal descriptor parameters to maximize C 2 selectivity. In conclusion, these findings demonstrate the importance of considering electrical double layer effects in reduction reactions and offer a useful framework for comparing solvation models and predicting optimal electrochemical conditions for specific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Vitro Selection of Antibodies Targeting Yersinia pestis Membrane Lipids Using Nanodisc-Based Antigen Presentation

Proteins are the most common targets for antibody discovery and vaccine development, but their sequence variability can limit the breadth of resulting antigens. Lipids represent an alternative class of antigens due to their structural conservation and roles in host–pathogen interactions. Here, we describe the development and optimization of an in vitro antibody selection workflow using lipid-containing nanodiscs as antigen presentation platforms to enable phage and yeast display selections under conditions adapted for these non-protein targets. Lipopolysaccharide (LPS) nanodiscs were first used as a model system to evaluate selection strategies, including competitive and subtractive approaches to reduce non-specific binders, yielding peptide and single-chain variable fragment (scFv) binders that were affinity matured to improve binding signals. The same approach was subsequently used to select scFv antibodies that recognize lipid nanodiscs prepared from Yersinia pestis membrane lipid extracts. These antibodies show binding to lipid nanodiscs derived from Y. pestis, with evidence of selectivity relative to control nanodiscs. Overall, this work establishes a workflow for antibody selection against lipid-containing nanodisc antigens and highlights practical considerations associated with these targets. The approach may be useful for generating affinity reagents to membrane-associated lipids, although further characterization is required to define antigen specificity and functional activity.

59 BASIC BIOLOGICAL SCIENCES↗