Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Electromagnon excitation in the field-induced nonlinear ferrimagnetic phase of Ba 2 Mg 2 Fe 12 O 22 studied by polarized inelastic neutron and terahertz time-domain optical spectroscopy

We have studied magnetic excitations in a field-induced noncollinear commensurate ferrimagnetic phase of Ba 2 Mg 2 Fe 12 O 22 by means of polarized inelastic neutron scattering (PINS) and terahertz (THz) time-domain optical spectroscopy under magnetic field. A previous THz spectroscopy study reported that the field-induced phase exhibits electric-dipole-active excitations with energies of around 5 meV [Kida et al., Phys. Rev. B 83, 064422 (2011)]. In the present PINS measurements, we observed inelastic scattering signals around 5 meV at the zone center in the spin-flip channel. This directly shows that the electric-dipole-active excitations are indeed of magnetic origin, that is, electromagnons . In addition, the present THz spectroscopy confirms that the excitations have oscillating electric polarization parallel to the c axis. In terms of the spin-current model (Katsura-Nagaosa-Balatsky model), the noncollinear magnetic order in the field-induced phase can induce static electric polarization perpendicular to the c axis, but not dynamic electric polarization along the c axis. Furthermore, we suggest that the electromagnon excitations can be explained by applying the magnetostriction model to the out-of-phase oscillations of the magnetic moments, which is deduced from the present experimental results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Positron annihilation spectroscopy investigation of vacancy defects in neutron-irradiated 3 C -SiC

We described positron annihilation spectroscopy characterization results for neutron-irradiated 3 C -SiC, with a specific focus on explaining the size and character of vacancy clusters as a complement to the current understanding of the neutron irradiation response of 3 C -SiC. Positron annihilation lifetime spectroscopy was used to capture the irradiation temperature and dose dependence of vacancy defects in 3 C -SiC following neutron irradiation from 0.01 to 31 dpa in the temperature range from 380C °to 790C .° The neutral and negatively charged vacancy clusters were identified and quantified. The results suggest that the vacancy defects that were measured by positron annihilation spectroscopy technique contribute very little to the transient swelling of SiC. Additionally, we used coincidence Doppler broadening measurement to investigate the chemical identity surrounding the positron trapping sites.Finally, we found that silicon vacancy-related defects dominate in the studied materials and the production of the antisite defect C Si may result in an increase in the probability of positron annihilation with silicon core electrons.

36 MATERIALS SCIENCE↗

In-beam γ-ray and electron spectroscopy of 249,251 Md

The odd-Z 251 Md nucleus was studied using combined γ-ray and conversion-electron in-beam spectroscopy. Besides the previously observed rotational band based on the [521]1/2 - configuration, another rotational structure has been identified using γ-γ coincidences. The use of electron spectroscopy allowed the rotational bands to be observed over a larger rotational frequency range. Using the transition intensities that depend on the gyromagnetic factor, a [514]7/2 - single-particle configuration has been inferred for this band, i.e., the ground-state band. A physical background that dominates the electron spectrum with an intensity of ≃60% was well reproduced by simulating a set of unresolved excited bands. Moreover, a detailed analysis of the intensity profile as a function of the angular momentum provided a method for deriving the orbital gyromagnetic factor, namely g K = $0.69$ $^{+0.19}_{-0.16}$ for the ground-state band. The odd-Z 249 Md was studied using γ-ray in-beam spectroscopy. Evidence for octupole correlations resulting from the mixing of the Δl = Δ j = 3 [521]3/2 - and [633]7/2 + Nilsson orbitals were found in both 249,251 Md. Here, a surprising similarity of the 251 Md ground-state band transition energies with those of the excited band of 255 Lr has been discussed in terms of identical bands. Lastly, Skyrme-Hartree-Fock-Bogoliubov calculations were performed to investigate the origin of the similarities between these bands.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence against the Efimov effect in 12 C from spectroscopy and astrophysics

Background: The Efimov effect is a universal phenomenon in physics whereby three-body systems are stabilized via the interaction of an unbound two-body subsystems. A hypothetical state in 12 C at 7.458-MeV excitation energy, comprising a loose structure of three α particles in mutual two-body resonance, has been suggested in the literature to correspond to an Efimov state in nuclear physics. The existence of such a state has not been demonstrated experimentally. Purpose: Using a combination of γ spectroscopy, charged-particle spectroscopy, and astrophysical rate calculations allowing for strict limits on the existence of such a state to been established here. Method: Using the combined data sets from two recent experiments, one with the TexAT (Texas Active Target) TPC (Time Projection Chamber) to measure α decay and the other with Gammasphere to measure γ decay of states in 12 C populated by 12 N and 12 B β decay, respectively, we achieve high sensitivity to states in close proximity to the α threshold in 12 C. Results: No evidence of a state at 7.458 MeV is seen in either data set. Using a likelihood method, the 95% confidence limit γ -decay branching ratio is determined as a function of the β-decay feeding strength relative to the Hoyle state. In parallel, calculations of the 3α reaction rate show the inclusion of the Efimov corresponds to a large increase in the reaction rate around 5 × 10 7 K. Conclusion: From decay spectroscopy—at the 95% confidence limit, the Efimov state cannot exist at 7.458 MeV with any γ-decay branching ratio unless the β strength is less than 0.7% of the Hoyle state. This limit is evaluated for a range of different excitation energies and the results are not favorable for existence of the hypothetical Efimov state in 12 C . Furthermore, the 3α reaction rate with the inclusion of a state between 7.43 and 7.53 MeV exceeds the rate required for stars to undergo the red giant phase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-Time Observation of Molecular Spinning with Angular High-Harmonic Spectroscopy

We demonstrate an angular high-harmonic spectroscopy method to probe the spinning dynamics of a molecular rotation wave packet in real time. With the excitation of two time-delayed, polarization-skewed pump pulses, the molecular ensemble is impulsively kicked to rotate unidirectionally, which is subsequently irradiated by another delayed probe pulse for high-order harmonic generation (HHG). The spatiotemporal evolution of the molecular rotation wave packet is visualized from the time-dependent angular distributions of the HHG yields and frequency shift measured at various polarization directions and time delays of the probe pulse. Here, the observed frequency shift in HHG is demonstrated to arise from the nonadiabatic effect induced by molecular spinning. Different from the previous spectroscopic and Coulomb explosion imaging techniques, the angular high-harmonic spectroscopy method can reveal additionally the electronic structure and multiple orbitals of the sampled molecule. All the experimental findings are well reproduced by numerical simulations. Further extension of this method would provide a powerful tool for probing complex polyatomic molecules with HHG spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrafast X-Ray Absorption Spectroscopy of Strongly Correlated Systems: Core Hole Effect

Recently, ultrafast pump-probe spectroscopy has provided insightful information about the nonequilibrium dynamics of excitations in materials. In a typical experiment of time-resolved x-ray absorption spectroscopy, the systems are excited by a femtosecond laser pulse (pump pulse) followed by an x-ray probe pulse after a time delay to measure the absorption spectra of the photoexcited systems. We present a theory for nonequilibrium x-ray absorption spectroscopy in one-dimensional strongly correlated systems. The core hole created by the x ray is modeled as an additional effective potential of the core hole site, which changes the spectrum qualitatively. In equilibrium, the spectrum reveals the charge gap at half-filling and the metal-insulator transition in the presence of the core hole effect. Moreover, a pump-probe scheme is introduced to drive the system out of equilibrium before the x-ray probe. The effects of the pump pulse with varying frequencies, shapes, and fluences are discussed for the dynamics of strongly correlated systems in and out of resonance. The spectrum suggests that the driven insulating state has a metallic droplet around the core hole. The rich structures of the nonequilibrium x-ray absorption spectrum give more insight into the dynamics of electronic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hard-X-Ray Spectroscopy with a Spectrographic Approach

Hard-x-ray spectroscopy relies on a suite of modem techniques for studies of vibrational, electronic, and magnetic excitations in condensed matter. At present, the energy resolution of these techniques can be improved only by decreasing the spectral window of the involved optics-monochromators arid analyzers- thereby sacrificing the intensity. Here, we demonstrate hard-x-ray spectroscopy with greatly improved energy resolution without narrowing the spectral window by adapting principles of spectrographic imaging to the hard-x-ray regime. Similar to Newton's classical prism, the hard-x-ray spectrograph disperses different "colors"-i.e., energies-of x-ray photons in space. Then, selecting each energy component with a slit ensures high energy resolution, whereas measuring x-ray spectra with all components of a broad spectral window keeps the intensity. We employ the principles of spectrographic imaging for phonon spectroscopy. Here the new approach revealed anomalous soft atomic dynamics in α-iron, a phenomenon which was not previously reported in the literature. Finally, we argue that hard-x-ray spectrographic imaging also could be a path to discovering new physics in studies of electronic and magnetic excitations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved X-ray Spectroscopy from the Atomic Orbital Ground State Up

X-ray spectroscopy has been a key method to determine ground and excited state properties of quantum materials with atomic specificity. Now, new x-ray facilities are opening the door to the study of pump-probe x-ray spectroscopy - specifically time-resolved x-ray absorption (trXAS) and time-resolved resonant inelastic x-ray scattering (trRIXS). In this paper we will present simulations of each of these spectroscopies using a time-domain full atomic multiplet, charge transfer Hamiltonian, adapted to study the properties of a generalized cluster model including a central transition metal ion caged by ligand atoms in a planar geometry. The numerically evaluated trXAS and trRIXS cross-sections for representative electron configurations 3d9 and 3d8 demonstrate the insights that can be obtained from charge transfer pumping, and how this nonequilibrium process affects ground and excited state properties. The straightforward characterization of the excitations in these systems, based on our analysis of the simulations, can serve as a benchmark for future experiments, as access to these time-resolved spectroscopic techniques becomes more widely available.

Jost, Daniel↗

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.

Uhlig, J.↗

Alpha Coincidence Spectroscopy studied with GEANT4

Abstract The high-energy side of peaks in alpha spectra, e.g. 241Am, as measured with a silicon detector has structure caused mainly by alpha-conversion electron and to some extent alphagamma coincidences. We compare GEANT4 simulation results to 241Am alpha spectroscopy measurements with a passivated implanted planar silicon detector. A large discrepancy between the measurements and simulations suggest that the GEANT4 photon evaporation database for 237Np (daughter of 241Am decay) does not accurately describe the conversion electron spectrum and therefore was found to have large discrepancies with experimental measurements. We describe how to improve the agreement between GEANT4 and alpha spectroscopy for actinides of interest by including experimental measurements of conversion electron spectroscopy into the photon evaporation database.

Dion, Michael P.↗

On‐line discrimination of storage shelf‐life and prediction of post‐harvest quality for strawberry fruit by visible and near infrared spectroscopy

Abstract Quick assessment of storage time is important for the guarantee of fruit shelf‐life. On‐line discrimination of refrigerated storage time and prediction of post‐harvest quality for strawberry fruit was carried out by visible and near‐infrared (Vis/NIR) spectroscopy. For the classification of samples with storage time of 1, 3, 5, and 7 days, partial least square discriminant analysis (PLS‐DA) achieved correct classified rates of 93.3–97.4% in prediction based on selected wavelengths obtained by competitive adaptive reweighted sampling (CARS) at speeds of 0.05, 0.10, and 0.15 m/s. Moreover, for prediction of soluble solids content (SSC) in strawberry, the determination coefficient ( r p 2 ), root mean square error of prediction (RMSEP), and RPD value obtained by PLS coped with CARS at fruit moving speed of 0.10 m/s was 0.733, 0.699 °Brix and 1.96, respectively. Overall, this study indicates that Vis–NIR spectroscopy offers the potential as an on‐line tool for quality assurance of strawberry fruit. Practical applications Visible and near‐infrared (Vis/NIR) spectroscopy is a very attractive technique for nondestructive evaluation of quality of food products. Strawberry has an extremely short shelf‐life which is estimated to be less than 5 days. Rapid identification its postharvest storage time is essential for the evaluation of its shelf‐life. Based on the results reported here, Vis–NIR has the potential for on‐line monitoring of postharvest storage time and post‐harvest quality for strawberry fruit in real situation.

Shen, Fei↗

Utilization of PARAFAC ‐Modeled Excitation‐Emission Matrix ( EEM ) Fluorescence Spectroscopy to Identify Biogeochemical Processing of Dissolved Organic Matter in a Northern Peatland

Abstract In this study, we contrast the fluorescent properties of dissolved organic matter ( DOM ) in fens and bogs in a Northern Minnesota peatland using excitation emission matrix fluorescence spectroscopy with parallel factor analysis ( EEM ‐ PARAFAC ). EEM ‐ PARAFAC identified four humic‐like components and one protein‐like component and the dynamics of each were evaluated based on their distribution with depth as well as across sites differing in hydrology and major biological species. The PARAFAC ‐ EEM experiments were supported by dissolved organic carbon measurements ( DOC ), optical spectroscopy ( UV ‐Vis), and compositional characterization by ultrahigh resolution Fourier transform ion cyclotron resonance mass spectroscopy ( FT ‐ ICR MS ). The FT ‐ ICR MS data indicate that metabolism in peatlands reduces the molecular weights of individual components of DOM , and oxygen‐rich less aromatic molecules are selectively biodegraded. Our data suggest that different hydrologic and biological conditions within the larger peat ecosystem drive molecular changes in DOM , resulting in distinctly different chemical compositions and unique fluorescent fingerprints. PARAFAC modeling of EEM data coupled with ultrahigh resolution FT ‐ ICR MS has the potential to provide significant molecular‐based information on DOM composition that will support efforts to better understand the composition, sources, and diagenetic status of DOM from different terrestrial and aquatic systems.

Tfaily, Malak M.↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗

Magnetic resonance spectroscopy of the human brain

I give a brief description of the magnetic resonance spectroscopy (MRS) in the human brain examinations. MRS allows a noninvasive chemical analysis of the brain using a standard high field MR system. Nowadays, the dominant form of MR brain spectroscopy is proton spectroscopy. Two main techniques of MRS, which utilize the chemical shift of metabolites in the external magnetic field, are SVS (single voxel) and CSI (single slice). The major peaks in the spectrum of a normal brain include NAA, Cr, Cho and m-Ins, which are neuronal, energetic, membrane turnover and glial markers, respectively. In disease, two pathological metabolites can be found in the brain spectra: Lac, which is end product of anaerobic glycolysis and Lip, which is a marker of membrane breakdown, occurring in necrosis. The common way to analyze clinical spectra is to determine metabolite ratios, e.g. NAA/Cr, Cho/Cr, Cho/NAA. This analysis permits a safe and noninvasive examination of the brain tissue as each disease state has its own characteristic spectroscopic image. MRS is a valuable diagnostic tool in such clinical applications as detecting brain tumors and differentiating tumors from inflammatory and infectious processes. Proton MRS is also very helpful in diagnostic of ischemic lesions, Alzheimer’s disease and hepatic encephalopathy. The MRS brain spectra should always be correlated with the Magnetic Resonance Imaging (MRI) results and alone cannot make neurological diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vibronic and Environmental Effects in Simulations of Optical Spectroscopy

Including both environmental and vibronic effects is important for accurate simulation of optical spectra, but combining these effects remains computationally challenging. We outline two approaches that consider both the explicit atomistic environment and the vibronic transitions. Both phenomena are responsible for spectral shapes in linear spectroscopy and the electronic evolution measured in nonlinear spectroscopy. The first approach utilizes snapshots of chromophore-environment configurations for which chromophore normal modes are determined. We outline various approximations for this static approach that assumes harmonic potentials and ignores dynamic system-environment coupling. The second approach obtains excitation energies for a series of time-correlated snapshots. This dynamic approach relies on the accurate truncation of the cumulant expansion but treats the dynamics of the chromophore and the environment on equal footing. Both approaches show significant potential for making strides toward more accurate optical spectroscopy simulations of complex condensed phase systems.

Chemistry↗

Diffuse Reflectance Spectroscopy and Principal Component Analysis to Retrospectively Determine Production History of Plutonium Dioxide

Diffuse reflectance spectroscopy measurements in the shortwave infrared (930–1600 nm) spectral region were acquired for Pu 2 (C 2 O 4 ) 3 •9H 2 O and its thermal decomposition product, PuO 2 . We analyzed a total of eight PuO 2 samples that were produced at different calcination temperatures (300, 350, 450, 525, 600, 675, 750, and 900 °C). Our goal was to identify spectroscopic fingerprints that could be used to gain retrospective information regarding the production parameters of these important nuclear compounds. The diffuse reflectance spectrum of Pu 2 (C 2 O 4 ) 3 •9H 2 O features several broad bands that currently preclude detailed analysis. However, all PuO 2 samples produced relatively sharp spectral features that got sharper and more intense for samples that were produced at higher calcination temperatures. The electronic band observed at 1433 nm in the diffuse reflectance spectra of PuO 2 was found to be a sensitive indicator of crystallinity; a result that is corroborated by ancillary Raman spectroscopy measurements. Principal component analysis of diffuse reflectance spectra was able to clearly rank and categorize PuO 2 samples based on the calcination temperature that was employed during their production. Thus, we show herein that important retrospective information pertaining to the process history of PuO 2 can be gained through the relatively simplistic combination of diffuse reflectance spectroscopy and principal component analysis. This discovery presents a new method for determining the provenance and process history of PuO 2 and should have an impact in the fields of nuclear forensics and nuclear nonproliferation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data for Rapid and High-Throughput Determination of Sorghum ( Sorghum bicolor ) Biomass Composition using Near Infrared Spectroscopy and Chemometrics

Compositional characterization of biomass is vital for the biofuel industry. Traditional wet chemistry-based methods for analyzing biomass composition are laborious, time-consuming, and require extensive use of chemical reagents as well as highly skilled personnel. In this study, near-infrared (NIR) spectroscopy was used to quickly assess the composition of above-ground vegetative biomass from 113 diverse, photoperiod-sensitive, biomass-type sorghum ( Sorghum bicolor ) accessions cultivated under field conditions in Central Illinois. Biomass samples were analyzed using NIR spectra collected in the spectral range of 867–2536 nm, with their chemical compositions determined following the National Renewable Energy Laboratory (NREL) protocol. Advanced spectral pre-treatment and band selection techniques were utilized to develop calibration models using partial least squares regression (PLSR). The models’ effectiveness was assessed through cross-validation and independent data tests. The predictions for moisture, ash, extractives, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin were accurate and reliable, demonstrating the capability of NIR spectroscopy to provide rapid and precise characterization of sorghum biomass. The results demonstrated that NIR spectroscopy is an efficient tool for rapidly characterizing sorghum biomass, making it a sustainable option for screening desirable feedstock for biofuel or bioproduct production.

Biomass Analytics↗

X-ray absorption spectroscopy using a self-seeded soft X-ray free-electron laser

X-ray free electron lasers (XFELs) enable unprecedented new ways to study the electronic structure and dynamics of transition metal systems. L-edge absorption spectroscopy is a powerful technique for such studies and the feasibility of this method at XFELs for solutions and solids has been demonstrated. But, the required x-ray bandwidth is an order of magnitude narrower than that of self-amplified spontaneous emission (SASE), and additional monochromatization is needed. We compare L-edge x-ray absorption spectroscopy (XAS) of a prototypical transition metal system based on monochromatizing the SASE radiation of the linac coherent light source (LCLS) with a new technique based on self-seeding of LCLS. We demonstrate how L-edge XAS can be performed using the self-seeding scheme without the need of an additional beam line monochromator. Lastly, we show how the spectral shape and pulse energy depend on the undulator setup and how this affects the x-ray spectroscopy measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗