Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Multiplanar Synthetic Arrays and Their Application to Full-Scale Landing Gear Noise Source Identification

Identification and quantification of noise sources generated by the landing gears of large civil transports are critical for the development of viable abatement technologies that can be applied locally to affect solely the source regions. Leveraging validated computational data sets obtained from airframe noise simulations of a full-scale B777-300ER aircraft, a frame-work based on multiplanar synthetic arrays was developed to examine landing gear sources. The position of the arrays relative to the aircraft nose or main landing gears, the number of microphones in each array, and their distribution pattern were judiciously selected to provide adequate spatial resolution of the sources in the primary flyover, sideline, and upstream directions while maintaining reasonable signal-to-noise ratio and beamwidth over a wide frequency range. Overall, seven synthetic arrays with 800 microphones each, for a total of 5,600 microphones, were used in the framework. Fully synchronous synthetic pressure records at each microphone location were obtained from the simulated data sets via a Ffowcs-Williams and Hawkings integral approach, with flow quantities on a permeable data surface enclosing the source regions used as input. Various applications of synthetic multiplanar arrays to acoustic data analysis are presented; the advantages of the framework in properly resolving and identifying the B777 landing gear sources is demonstrated by comparing three-dimensional source distribution maps with those obtained from a synthetic version of the ground-based microphone array used during flight tests of the same aircraft.

airframe noise↗

GAMMA DOSE RATE NEAR A NEW (252)Cf BRACHYTHERAPY SOURCE

A new generation of medical grade (252)Cf sources was developed in 2002 at the Oak Ridge National Laboratory. The combination of small size and large activity of (252)Cf makes the new source suitable to be used with the conventional high-dose-rate remote afterloading system for interstitial brachytherapy. A recent in-water calibration experiment showed that the measured gamma dose rates near the new source are slightly greater than the neutron dose rates, contradicting the well established neutron-to-gamma dose ratio of approximately 2:1 at locations near a (252)Cf brachytherapy source. Specifically, the MCNP-predicted gamma dose rate is a factor of two lower than the measured gamma dose rate at the distance of I cm, and the differences between the two results gradually diminish at distances farther away from the source. To resolve this discrepancy, we updated the source gamma spectrum by including in the ORIGEN-S data library the experimentally measured (252)Cf prompt gamma spectrum as well as the true (252)Cf spontaneous fission yield data to explicitly model delayed gamma emissions from fission products. We also investigated the bremsstrahlung X-rays produced by the beta particles emitted from fission product decays. The results show that the discrepancy of gamma dose rates is mainly caused by the omission of the bremsstrahlung X-rays in the MCNP runs. By including the bremsstrahlung X-rays, the MCNP results show that the gamma dose rates near a new (252)Cf source agree well with the measured results and that the gamma dose rates are indeed greater than the neutron dose rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a Position-Sensitive Multi-Anode Photomultiplier Tube for Finding Gamma-Ray Source Direction

In an urban environment where gamma-ray background counts vary rapidly, it is important to determine the angle (with respect to the detector system) of a discrete gamma-ray–emitting source for localization purposes. We have recently developed a handheld gamma-ray detection system that provides gamma-ray energy spectral data and angular position of the target source. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. The objectives of this project were to design and build a prototype, light-weight, hand-held, gamma-ray spectrometer with directional sensitivity. It is important for first responders in a radiological emergency to have an easy-to-use gamma spectrometric detection system that determines the incident gamma-ray energy along with the relative angular position of a point-like radioactive source in a near-field measurement (≤3 meters from the source). The technical challenge of this project, driven by search scenarios for monitoring crowds in a national special security events was to determine the relative angle of a gamma-ray–emitting source (50 μCi strong) at a distance of 3 meters from the detector in 3 minutes. We designed and built small, portable, light-weight directional gamma energy spectrometers using a position-sensitive multi-anode photomultiplier. All of three spectrometers showed remarkable (ΔΘ = ± 2°) sensitivity to relative angular position of the source in near-field laboratory measurements.

position-sensitive photomultiplier tube (PMT), mul↗

Identification of mixed sources with an organic scintillator-based radiation portal monitor

We have developed radionuclide identification algorithms for radiation portal monitor applications. One algorithm uses a spectral angle mapper to match the power spectral density of modified cumulative distribution functions of measured pulse height distributions to reference spectra, while the others rely on the decomposition of the observed spectrum as a linear mixture of known radionuclide spectra. Three algorithms were then tested for their ability to perform on-the-fly radionuclide identification on datasets acquired with a liquid organic scintillator-based pedestrian radiation portal monitor on moving special nuclear material and industrial radiological sources, as well as common medical isotopes. We quantified and compared the relative efficacies of the algorithms considered using F-score analysis. Measured radiation sources included 51 g of highly enriched uranium, 6.6 g of weapons grade plutonium, 241 Am, 133 Ba, 57 Co and 137 Cs sources with activities of several hundred kBq, as well as 260 kBq liquid solution samples of the medical isotopes 99m Tc, 111 In, 67 Ga, 123 I, 131 I, and 201 Tl. We achieved 100% positive identification, for three-second measurements of single sources moving at a source-transit speed of 1.2 m/s. For mixed sources with strongest and weakest sources having no more than a 5:1 ratio of detected counts, encouraging positive identification results were achieved with the un-mixing algorithms. Current radiation portal monitor designs suffer from a high incidence rate of nuisance radiation alarms caused in radiation portal monitor primary screenings by recent nuclear medicine patients and cargo containing large amounts of naturally occurring radioactive materials. Integrating reliable on-the-fly radionuclide identification into the radiation portal monitors could lower the number of nuisance alarms requiring time-consuming secondary inspections.

47 OTHER INSTRUMENTATION↗

Heuristic based analytics for gas leak source identification

Heuristic-based techniques for gas leak source identification are provided. In one aspect, a method for identifying a location of a gas leak source includes: obtaining gas sensor data and wind data synchronously from a gas leak detection system having a network of interconnected motes comprising gas sensors and wind sensors, with the gas sensors arranged around possible gas leak sources in a given area of interest; identifying the location of the gas leak source using the gas sensor data and wind data; and determining a magnitude of gas leak from the gas leak source using the location of the gas leak source and a distance d between the location of the gas leak source and a select one of the gas sensors from which the gas sensor data was obtained. A gas leak detection system is also provided.

03 NATURAL GAS↗

Source identification by non-negative matrix factorization combined with semi-supervised clustering

Machine-learning methods and apparatus are provided to solve blind source separation problems with an unknown number of sources and having a signal propagation model with features such as wave-like propagation, medium-dependent velocity, attenuation, diffusion, and/or advection, between sources and sensors. In exemplary embodiments, multiple trials of non-negative matrix factorization are performed for a fixed number of sources, with selection criteria applied to determine successful trials. A semi-supervised clustering procedure is applied to trial results, and the clustering results are evaluated for robustness using measures for reconstruction quality and cluster separation. The number of sources is determined by comparing these measures for different trial numbers of sources. Source locations and parameters of the signal propagation model can also be determined. Disclosed methods are applicable to a wide range of spatial problems including chemical dispersal, pressure transients, and electromagnetic signals, and also to non-spatial problems such as cancer mutation.

97 MATHEMATICS AND COMPUTING↗

Data Release Report for the Source Physics Experiment Phase II: Dry Alluvium Geology Experiments (DAG-1 through DAG-4), Nevada National Security Site

The Dry Alluvium Geology (DAG) project was Phase II of the Source Physics Experiment and consisted of a series of four chemical explosive tests conducted in the same source hole on the Nevada National Security Site. This hole is located at 37.1146°N and -116.0693°W, with a surface elevation of 1,285.2 meters (m) (4,216.5 feet [ft]) above sea level. The first test (DAG-1) was conducted on July 20, 2018, at 16:51:52.67838 Coordinated Universal Time (UTC). The explosive source for DAG-1 was nitromethane initiated by a small plastic-bonded explosive (PBX) charge, detonated at the depth of 385.0 m (1,263.2 ft) below ground surface. DAG-1 had a trinitrotoluene (TNT) equivalent yield of 0.908 metric tons (2,002 pounds [lbs]). DAG-2 was conducted on December 19, 2018, at 18:45:56.92115 UTC. This test was the largest in the series, with a TNT equivalent yield of 50.997 metric tons (112,429 lbs). The explosive source for DAG-2 was nitromethane initiated by a small PBX charge, detonated at the depth of 299.8 m (983.6 ft) below ground surface. DAG-3 was conducted on April 27, 2019, at 15:49:01.84183 UTC. The explosive source for this test was nitromethane initiated by a small PBX charge, detonated at the depth of 149.9 m (492.0 ft) below ground surface. DAG-3 had a TNT equivalent yield of 0.908 metric tons (2,002 lbs). The final DAG test (DAG-4) was conducted on June 22, 2019, at 21:06:19.87632 UTC. The explosive source for DAG-4 was nitromethane initiated by a small PBX charge, detonated at the depth of 51.6 m (169.3 ft) below ground surface. DAG-4 had a TNT equivalent yield of 10.357 metric tons (22,833 lbs). The four tests were recorded by an extensive set of instrumentation that included sensors both at near-field (less than 200 m) and far-field (200 m or greater) distances. The near-field instruments consisted of three-component (3C) accelerometers installed at various depths ranging from 51.6 to 385 m (169.3 to 1,263.1 ft) below ground surface in boreholes positioned around the source hole, and arrays of single-component and 3C accelerometers on the surface. The far-field network comprised a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and 3C accelerometers at distances of 200 m to 400 kilometers. In addition, the DAG-2, DAG-3, and DAG-4 explosions were recorded by a temporary array of 496 geophones arranged in a densely spaced grid pattern known as “Large N.” This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the four DAG tests and the various types of near-field, far-field, and other data that are available. Assembled data sets are accessible through: Incorporated Research Institutions for Seismology, Data Management Center 1408 NE 45th Street, Suite 201, Seattle, Washington 98105 USA. www.iris.washington.edu

58 GEOSCIENCES↗

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Source identification by non-negative matrix factorization combined with semi-supervised clustering

Machine-learning methods and apparatus are provided to solve blind source separation problems with an unknown number of sources and having a signal propagation model with features such as wave-like propagation, medium-dependent velocity, attenuation, diffusion, and/or advection, between sources and sensors. In exemplary embodiments, multiple trials of non-negative matrix factorization are performed for a fixed number of sources, with selection criteria applied to determine successful trials. A semi-supervised clustering procedure is applied to trial results, and the clustering results are evaluated for robustness using measures for reconstruction quality and cluster separation. The number of sources is determined by comparing these measures for different trial numbers of sources. Source locations and parameters of the signal propagation model can also be determined. Disclosed methods are applicable to a wide range of spatial problems including chemical dispersal, pressure transients, and electromagnetic signals, and also to non-spatial problems such as cancer mutation.

Alexandrov, Boian S.↗

The Impacts of Source Location in Tomographic Gamma Scanning - 17324

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has been equipped to use various collimators and attenuators to assay containers under a wide range of operational conditions. In this paper, we report on experimental work using TGS systems aimed at evaluating the effects of source locations at the limits of volume elements, or voxels, defined in the image reconstruction. These include sources placed at voxel boundaries within a single vertical layer and sources placed in the lowest and highest possible vertical positions within the containers. Building upon previous studies, the accuracy of the TGS system was also assessed by varying the radial position of a point source within a vertical segment. The robustness of the TGS image reconstruction algorithm to location of the sources location was also analyzed as a function of matrix density and gamma-ray energy. Methods to reduce the biases from source location at extreme positions within the container were implemented and tested. The results from this work have been used to better understand the total measurement uncertainty (TMU) and analysis methodology used in TGS systems currently deployed and under development. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reconstruction of Irradiation History of Am-241/Be Startup Sources for Disposal at WIPP - 18644

The National Nuclear Security Administration, Global Material Security (GMS)/ Off-site Source Recovery Program (OSRP) requires an approved final disposition pathway for sealed neutron startup sources with undocumented or questionable irradiation histories. To obtain approval for WIPP disposal, a reliable method is required to determine yields of transmutation, as well as fission and activation products contained within the source at the time of disposal. This paper presents a method to reconstruct the irradiation history of americium beryllium (Am/Be) reactor startup sources using gamma spectroscopy, ORIGEN modeling and the initial composition of the source. Using this method, measured isotopes in the Am/Be startup sources are related to the WIPP disposal requirements. Maximum allowable measurement uncertainties have been quantified and related to uncertainties in the WIPP required isotopes. Characterization calculations and experimental measurements of irradiated Am/Be sources are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

BRIGHT SOURCE SUBTRACTION REQUIREMENTS FOR REDSHIFTED 21 cm MEASUREMENTS

The H I 21 cm transition line is expected to be an important probe into the cosmic dark ages and epoch of reionization. Foreground source removal is one of the principal challenges for the detection of this signal. This paper investigates the extragalactic point source contamination and how accurately bright sources ({approx}>1 Jy) must be removed in order to detect 21 cm emission with upcoming radio telescopes such as the Murchison Widefield Array. We consider the residual contamination in 21 cm maps and power spectra due to position errors in the sky model for bright sources, as well as frequency-independent calibration errors. We find that a source position accuracy of 0.1 arcsec will suffice for detection of the H I power spectrum. For calibration errors, 0.05% accuracy in antenna gain amplitude is required in order to detect the cosmic signal. Both sources of subtraction error produce residuals that are localized to small angular scales, k{sub perpendicular} {approx}> 0.05 Mpc{sup -1}, in the two-dimensional power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

STELLAR X-RAY SOURCES IN THE CHANDRA COSMOS SURVEY

We present an analysis of the X-ray properties of a sample of solar- and late-type field stars identified in the Chandra Cosmic Evolution Survey (COSMOS), a deep (160 ks) and wide ({approx}0.9 deg{sup 2}) extragalactic survey. The sample of 60 sources was identified using both morphological and photometric star/galaxy separation methods. We determine X-ray count rates, extract spectra and light curves, and perform spectral fits to determine fluxes and plasma temperatures. Complementary optical and near-IR photometry is also presented and combined with spectroscopy for 48 of the sources to determine spectral types and distances for the sample. We find distances ranging from 30 pc to {approx}12 kpc, including a number of the most distant and highly active stellar X-ray sources ever detected. This stellar sample extends the known coverage of the L{sub X}-distance plane to greater distances and higher luminosities, but we do not detect as many intrinsically faint X-ray sources compared to previous surveys. Overall the sample is typically more luminous than the active Sun, representing the high-luminosity end of the disk and halo X-ray luminosity functions. The halo population appears to include both low-activity spectrally hard sources that may be emitting through thermal bremsstrahlung, as well as a number of highly active sources in close binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CHANDRA COSMOS SURVEY. III. OPTICAL AND INFRARED IDENTIFICATION OF X-RAY POINT SOURCES

The Chandra COSMOS Survey (C-COSMOS) is a large, 1.8 Ms, Chandra program that has imaged the central 0.9 deg{sup 2} of the COSMOS field down to limiting depths of 1.9 Multiplication-Sign 10{sup -16} erg cm{sup -2} s{sup -1} in the soft (0.5-2 keV) band, 7.3 Multiplication-Sign 10{sup -16} erg cm{sup -2} s{sup -1} in the hard (2-10 keV) band, and 5.7 Multiplication-Sign 10{sup -16} erg cm{sup -2} s{sup -1} in the full (0.5-10 keV) band. In this paper we report the i, K, and 3.6 {mu}m identifications of the 1761 X-ray point sources. We use the likelihood ratio technique to derive the association of optical/infrared counterparts for 97% of the X-ray sources. For most of the remaining 3%, the presence of multiple counterparts or the faintness of the possible counterpart prevented a unique association. For only 10 X-ray sources we were not able to associate a counterpart, mostly due to the presence of a very bright field source close by. Only two sources are truly empty fields. The full catalog, including spectroscopic and photometric redshifts and classification described here in detail, is available online. Making use of the large number of X-ray sources, we update the 'classic locus' of active galactic nuclei (AGNs) defined 20 years ago in soft X-ray surveys and define a new locus containing 90% of the AGNs in the survey with full-band luminosity >10{sup 42} erg s{sup -1}. We present the linear fit between the total i-band magnitude and the X-ray flux in the soft and hard bands, drawn over two orders of magnitude in X-ray flux, obtained using the combined C-COSMOS and XMM-COSMOS samples. We focus on the X-ray to optical flux ratio (X/O) and we test its known correlation with redshift and luminosity, and a recently introduced anti-correlation with the concentration index (C). We find a strong anti-correlation (though the dispersion is of the order of 0.5 dex) between X/O computed in the hard band and C and that 90% of the obscured AGNs in the sample with morphological information live in galaxies with regular morphology (bulgy and disky/spiral), suggesting that secular processes govern a significant fraction of the black hole growth at X-ray luminosities of 10{sup 43}-10{sup 44.5} erg s{sup -1}. We also investigate the degree of obscuration of the sample using the hardness ratio, and we compare the X-ray color with the near-infrared to optical color.

79 ASTRONOMY AND ASTROPHYSICS↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources

Purpose: The goal of this work is to compare D{sub m,m} (radiation transported in medium; dose scored in medium) and D{sub w,m} (radiation transported in medium; dose scored in water) obtained from Monte Carlo (MC) simulations for a subset of human tissues of interest in low energy photon brachytherapy. Using low dose rate seeds and an electronic brachytherapy source (EBS), the authors quantify the large cavity theory conversion factors required. The authors also assess whether applying large cavity theory utilizing the sources' initial photon spectra and average photon energy induces errors related to spatial spectral variations. First, ideal spherical geometries were investigated, followed by clinical brachytherapy LDR seed implants for breast and prostate cancer patients. Methods: Two types of dose calculations are performed with the GEANT4 MC code. (1) For several human tissues, dose profiles are obtained in spherical geometries centered on four types of low energy brachytherapy sources: {sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds, as well as an EBS operating at 50 kV. Ratios of D{sub w,m} over D{sub m,m} are evaluated in the 0-6 cm range. In addition to mean tissue composition, compositions corresponding to one standard deviation from the mean are also studied. (2) Four clinical breast (using {sup 103}Pd) and prostate (using {sup 125}I) brachytherapy seed implants are considered. MC dose calculations are performed based on postimplant CT scans using prostate and breast tissue compositions. PTV D{sub 90} values are compared for D{sub w,m} and D{sub m,m}. Results: (1) Differences (D{sub w,m}/D{sub m,m}-1) of -3% to 70% are observed for the investigated tissues. For a given tissue, D{sub w,m}/D{sub m,m} is similar for all sources within 4% and does not vary more than 2% with distance due to very moderate spectral shifts. Variations of tissue composition about the assumed mean composition influence the conversion factors up to 38%. (2) The ratio of D{sub 90(w,m)} over D{sub 90(m,m)} for clinical implants matches D{sub w,m}/D{sub m,m} at 1 cm from the single point sources. Conclusions: Given the small variation with distance, using conversion factors based on the emitted photon spectrum (or its mean energy) of a given source introduces minimal error. The large differences observed between scoring schemes underline the need for guidelines on choice of media for dose reporting. Providing such guidelines is beyond the scope of this work.

60 APPLIED LIFE SCIENCES↗