Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Novel Electron-Bubble Tracking Detectors

Our Columbia group, in collaboration with Brookhaven and SMU, has been carrying out R&D on tracking detectors in cryogenic liquids, including neon and helium. A cryostat purchased by this Grant capable of working temperatures down to 1 K and pressures above the critical point of neon and helium has been operated with a variety of noble fluids. Gaseous Electron Multipliers (GEM) with hydrogen additives have been operated with tracks of radioactive sources read out both by electrical charge detecting electronics, and an optical camera purchased by this Grant, measuring mobility, charge yield, transitions through phase boundaries, gain limitations, and other properties. The goal is very high resolution in large volumes. The scope of the project is the provision of a high performance camera and its installation in a cryogenic facility providing pressure up to 40 atmospheres and a temperature from ambient down to about 1 K. In this section we will address the goals and results having to do with this project and particularly the performance of the camera, and provide a summary of the status of the detector project. The technical development of digital cameras has been dominated for the last forty years by the Charge-Coupled Device technology (CCD). This allows photon recording on very small pixels on silicon planes that provide high quantum efficiency in the visible spectrum, recording the charge generated by a single photon stored on one pixel with an area of order ten microns square. The area can be up to several centimeters squared, containing a million pixels or more. The stores charge is usually read out by manipulating voltage biases to shift the charge in each pixel over to the next, and eventually out of the array and sent to an external processor and memory. Mass production has brought the cost per channel down to very small values and allowed cameras to be integrated to many consumer products. Thermal noise becomes larger than one photon on a single pixel at good temperature, and demand night vision and other demanding applications has led to intense R&D over the years, and small coolers that maintain the CCD at temperatures of more than 100K below ambient are integrated into the camera package. These systems are sold in quantity to amateur astronomers with the same silicon devices used in professional systems, provided long exposure times with less than one electron noise per pixel. In our particle readout, we are imaging a three-dimensional track drifting into the readout plane over time, and we need to read out one plane after another, and we need a high rate of pixel processing. For many years, the noise in the electronic amplifier matching the CCD to the external electronics led to noise levels of many electrons, much higher than in the CCD itself. A break-through was made by providing signal gain inside the CCD, connecting to the external line, by a Electron Multiplier CCD, using a number of electron avalanche stages, each with a small, stable gain. This device was brought out just before out application for the present Grant, provided the last link in the development chain, which allowed out optical readout concept to be implemented at reason fact. In fact, we profited from the falling cost by delaying our order for about a year, which, together with the university discount, allowed us to proceed within our budget. The camera we purchase from the firm ANDOR, which introduced the technique, comes with an extensive suite of software that allows the fast readout with different integration times, and makes a very convenient use in our application. We have been able to make images of the light signals coming from out GEM electron avalanche detectors under many conditions, with tracks of different particle types. We have reconfigured the system a number of times, using the results from the camera to learn how to change the TPC drift geometry and the GEM charge amplifier to improve performance, a process that is still going on. The camera purchase with this Grant has performed reliably and just as specified by the manufacturer and has been a trouble-free element of our larger product. The ability of being able to vary the pressure and temperature over a wide range is very important for several reasons: (1) we are able to choose a fluid density to make the best compromise between a range of low energy tracks long enough to measure, and higher density to minimize the detector size for a given rate; (2) we can identify the density the allows the avalanche rate that provides sufficient signal to noise for the low-energy tracks we need to measure in a given application; and (3) we can operate at the optimum density and hydrogen admixture for light production. A special cryostat was required to operate down to 1 K with pressures up to 40 Bar, well above the critical point of Neon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

pH-dependent structural change of the extracellular sensor domain of the DraK histidine kinase from Streptomyces coelicolor

Highlights: ► We described the biochemical and biophysical properties of the extracellular sensory domain (ESD) of DraK histidine kinase. ► The ESD of DraK showed a reversible pH-dependent conformational change in a wide pH range. ► The E83 is an important residue for the pH-dependent conformational change. -- Abstract: Recently, the DraR/DraK (Sco3063/Sco3062) two-component system (TCS) of Streptomycescoelicolor has been reported to be involved in the differential regulation of antibiotic biosynthesis. However, it has not been shown that under which conditions and how the DraR/DraK TCS is activated to initiate the signal transduction process. Therefore, to understand the sensing mechanism, structural study of the sensory domain of DraK is highly required. Here, we report the biochemical and biophysical properties of the extracellular sensory domain (ESD) of DraK. We observed a reversible pH-dependent conformational change of the ESD in a pH range of 2.5–10. Size-exclusion chromatography and AUC (analytical ultracentrifugation) data indicated that the ESD is predominantly monomeric in solution and exists in equilibrium between monomer and dimer states in acidic condition. Using NMR (nuclear magnetic resonance) and CD (circular dichroism) spectroscopy, our findings suggest that the structure of the ESD at low pH is more structured than that at high pH. In particular, the glutamate at position 83 is an important residue for the pH-dependent conformational change. These results suggest that this pH-dependent conformational change of ESD may be involved in signal transduction process of DraR/DraK TCS.

60 APPLIED LIFE SCIENCES↗

Evaluation of Deep Subsurface Resistivity Imaging for Hydrofracture Monitoring

This report describes the results of the first of its kind monitoring of a hydrofracture operation with electromagnetic measurements. The researchers teamed with oil and gas producer Encana Corporation to design and execute a borehole to surface monitoring of three fracture stages at a well pad in central Colorado. The field project consisted of an equipment upgrade, a survey design and modeling phase, several weeks of data collection, and data processing and interpretation. Existing Depth to Surface Resistivity (DSR) instrumentation was upgraded to allow for continuous high precision recording from downhole sources. The full system can now collect data continuously for up to 72 hours, which is sufficient to measure data for 10 frac stages. Next we used numerical modeling and frac treatment data supplied by Encana to design a field survey to detect EM signal from induced fractures. Prior to modeling we developed a novel technique for using well casing as an antenna for a downhole source. Modeling shows that 1) a measurable response for an induced fracture could be achieved if the facture fluid was of high salinity 2) an optimum fracture response is created when the primary source field is parallel to the well casing but perpendicular to the fracture direction. In mid-July, 2014 we installed an array of more than 100 surface sensors, distributed above the treatment wells and extending for approximately 1 km north and 750 m eastward. We applied a 0.6 Hz square wave signal to a downhole current electrode located in a horizontal well 200 m offset from the treatment well with a return electrode on the surface. The data were transmitted to a recording trailer via Wi-Fi where we monitored receiver and transmitter channels continuously in a 72-hour period which covered 7 frac stages, three of which were high salinity. Although the background conditions were very noisy we were able to extract a clear signal from the high salinity stages. Initial data interpretation attempts consisting of trying to directly invert collected data using a simple background starting model did not produce reasonable models. We next used a simulated data set to develop a constrained inversion workflow that places the downhole fracture in the correct location. Finally, we used a combination of forward and inverse models to fit the collected data to a model that incorporated 3 frac stages. This project provided a first-of-its-kind application of EM technology to map an induced fracture. The results demonstrated a clear anomaly during the operation that can be fit to a reasonable model of an induced fracture.

42 ENGINEERING↗

Real-Time Movement-Based Traffic Volume Prediction at Signalized Intersections

The traffic volume of each movement at signalized intersections can provide valuable information on real-time traffic conditions that enable traffic control systems to dynamically respond to the fluctuated traffic demands. Real-time movement-based traffic volume prediction is challenging due to various nonlinear spatial relationships at different locations/approaches and the complicated underlying temporal dependencies. In this study, a novel deep intersection spatial-temporal network (DISTN) is developed for real-time movement-based traffic volume prediction at signalized intersections, which considers both spatial and temporal features by the convolutional neural network (CNN) and long short-term memory (LSTM), respectively. In addition, the within-day, daily, and weekly periodic trends of traffic volume are also considered in the proposed model. This is the first time that a deep-learning method has been applied for movement-based traffic volume prediction at signalized intersections. In the numerical experiment, the proposed model is evaluated using real-world data and simulation data to demonstrate its effectiveness. The impacts of various structures of traffic networks on the proposed model are also discussed. Results show that the proposed model outperforms some of the state-of-the-art volume prediction methods currently in the literature.

99 GENERAL AND MISCELLANEOUS↗

Modulation of iridovirus-induced apoptosis by endocytosis, early expression, JNK, and apical caspase

Chilo iridescent virus (CIV) is the type species for the family Iridoviridae, which are large, isometric, cytoplasmic dsDNA viruses. We examined the mechanism of apoptosis induction by CIV. High CIV doses (CIV{sub XS}; 400 {mu}g/ml), UV-irradiated virus (CIV{sub UV}; 10 {mu}g/ml) and CVPE (CIV protein extract; 10 {mu}g/ml) induced apoptosis in 60% of treated Choristoneura fumiferana (IPRI-CF-124T) cells. Normal doses of infectious CIV (10 {mu}g/ml) induced apoptosis in only 10% of C. fumiferana (CF) cells. Apoptosis was inhibited by Z-IETD-FMK, an apical caspase inhibitor, indicating that CIV-induced apoptosis requires caspase activity. The putative caspase in CF cells was designated Cf-caspase-i. CIV{sub UV} or CVPE enhanced Cf-caspase-i activity by 80% at 24 h relative to mock-treated cells. Since the MAP kinase pathway induces or inhibits apoptosis depending on the context, we used JNK inhibitor SP600125 and demonstrated drastic suppression of CVPE-induced apoptosis. Thus, the JNK signaling pathway is significant for apoptosis in this system. Virus interaction with the cell surface was not sufficient for apoptosis since CIV{sub UV} particles bound to polysterene beads failed to induce apoptosis. Endocytosis inhibitors (bafilomycin or ammonium chloride) negated apoptosis induction by CIV{sub UV}, CIV{sub XS} or CVPE indicating that entry through this mode is required. Given the weak apoptotic response to infectious CIV, we postulated that viral gene expression inhibited apoptosis. CIV infection of cells pretreated with cycloheximide induced apoptosis in 69% of the cells compared to 10% in normal infections. Furthermore, blocking viral DNA replication with aphidicolin or phosphonoacetic acid suppressed apoptosis and Cf-caspase-i activity, indicating that early viral expression is necessary for inhibition of apoptosis, and de novo synthesis of viral proteins is not required for induction. We show for the first time that, in a member of the family Iridoviridae, apoptosis: (i) requires entry and endocytosis of virions or virion proteins, (ii) is inhibited under conditions permitting early viral expression, and (iii) requires the JNK signaling pathway. This is the first report of JNK signal requirement during apoptosis induction by an insect virus.

60 APPLIED LIFE SCIENCES↗

Microstructural and Defect Characterization in Ceramic Composites Using an Ultrasonic Guided Wave Scan System

In this study, an ultrasonic guided wave scan system was used to characterize various microstructural and flaw conditions in two types of ceramic matrix composites, SiC/SiC and C/SiC. Rather than attempting to isolate specific lamb wave modes to use for characterization (as is desired for many types of guided wave inspection problems), the guided wave scan system utilizes the total (multi-mode) ultrasonic response in its inspection analysis. Several time and frequency-domain parameters are calculated from the ultrasonic guided wave signal at each scan location to form images. Microstructural and defect conditions examined include delamination, density variation, cracking, and pre/ post-infiltration. Results are compared with thermographic imaging methods. Although the guided wave technique is commonly used so scanning can be eliminated, applying the technique in the scanning mode allows a more precise characterization of defect conditions.

Roth, D. J.↗

Filter failure detection for systems with large space structure dynamics

A failure detection filter is applied to the detection of actuator and sensor failures on a free-free beam. Computer simulation tests are used to verify the filter design and study the effect of unmodeled modes on filter performance. In actuator tests, the failure signal to spillover noise ratio was found to be greatest when the filter bandwidth was 5 rad/sec beyond the input frequency. Observation spillover, however, was found to vary widely in tests run under similar conditions (same input frequency and filter poles) but with different detector gains. In sensor tests, the maximum signal-to-noise ratio for varying filter bandwidth depended upon the initial conditions placed on the unmodeled modes; the performance was good even for initial amplitudes on the first unmodeled mode 7.5% of that on the last modeled mode.

Carignan, C. R.↗

Robustness of the smartpixels classifier for different simulated sensor geometries and non-ideal detector conditions

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in high-rate online event selection, such as the ATLAS or CMS first-level trigger systems. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p T ) based on the geometrical shape of the charge deposition (“cluster”). To design viable detectors for deployment, the dependence of the NN as a function of the sensor geometry, external magnetic field, irradiation, and noise must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. For the CMS HL-LHC sensor geometry, we obtain a signal efficiency of (91.9 ± 0.7)% and a data reduction of (29.7 ± 1.0)%. A smaller sensor pitch in the bending direction improves the p T discrimination, but a larger pitch can be partially compensated with detector thickness. Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by approximately 30–60% in absolute terms, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data. •ASIC-compatible track-momentum classifier is robust in realistic detector conditions.•About 90% signal efficiency and 30% data reduction per layer for CMS HL-LHC geometry.•Single-layer signal efficiency increases for smaller pixel pitch or thicker sensors.•Performance with noise or after radiation damage mostly recovered by retraining.

Shekar, Danush [Illinois U., Chicago] (ORCID:00000↗

Plant Roots: The Hidden Half: Calcium and Gravitropism - Chapter 16

Environmental signals such as light and gravity control many aspects of plant growth and development. In higher plants, the directional growth of an organ in response to stimuli such as gravity and light is considered a tropic movement. Such movement could be either positive or negative with respect to a specific stimulus. In general, stems show a positive response to light and negative response to gravity. In contrast, most roots show a positive response to gravity and a negative response to light. Investigations on plant tropism date back a century when Darwin studied the phototropic responses of maize seedlings (Darwin). Although the precise mechanism of signal perception and transduction in roots is not understood, Darwin recognized over 100 years ago that the root cap is the probable site of signal perception. He discovered that the removal of the root cap eliminates the ability of roots to respond to gravity. Other investigators have since confirmed Darwin's observation (Konings; Evans et al.). In recent years, especially with the advent of the U.S. Space Program, there has been a renewed interest in understanding how plants respond to extracellular signals such as gravity (Halstead and Dutcher). Studies on the mechanisms involved in perception and transduction of gravity signal by roots would ultimately help us to better understand gravitropism and also to grow plants under microgravity conditions as in space. In this chapter, we restrict ourselves to the role of calcium in transduction of the gravity signal. In doing so, emphasis is given to the role of calcium-modulated proteins and their role in signal transduction in gravitropism. Detailed reviews on various other aspects of gravitropism (Scott, Torrey, Wilkins, Fim and Digby, Feldman, Pickard, Moore and Evans, Halstead and Dutcher, Poovaiah et al.) and on the role of calcium as a messenger in signal transduction in general have been published (Helper and Wayne, Poovaiah and Reddy, Roberts and Hartnon, Bowler and Chua, Gilroy and Trewavas). Plant roots have been widely used to study the transduction of gravity and light signals (Poovaiah et al., Roux and Serlin). Most roots show positive gravitropic response in either dark or light. However, roots of some varieties of plants (e.g., Zea mays L., cv Merit, and Zea rwvs L., cv Golden Cross Bantam 70) show positive gravitropic response only in light (Feldman, Miyazaki et al.). Investigations from various laboratories indicate that calcium acts as a messenger in transducing gravity and light signals in plant roots(Pickard, Evans et al., Pooviah et al.).

Poovaiah, B. W.↗

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗

Using feature importance as an exploratory data analysis tool on Earth system models

Abstract. Machine learning (ML) models are commonly used to generate predictions, but these models can also support the discovery of new science. Generating accurate predictions necessitates that a model captures the structure of the underlying data. If the structure is properly extracted, ML could be a useful exploratory and evidential tool. In this paper, we present a case study that demonstrates the use of ML for exploratory data analysis (EDA) in the climate space. We apply the ML explainability method of spatiotemporal zeroed feature importance (stZFI) to understand how climate-variable associations evolve over space and time. Our analyses focus on data from ensembles of Earth system models (ESMs) which provide data on different climate states and conditions. We elect to work with ESM ensembles since they allow us to compare feature importance across alternative scenarios not available with observed data. The ensembles also account for natural variability so that we can distinguish between signal and noise due to natural climate variability when computing feature importance. The use of perturbed initial condition ensembles introduces variability mimicking the natural variability in the atmosphere; thus the signals emerging using feature importance (FI) can be evaluated against the natural variability in the climate system. For our analyses, we consider the 1991 volcanic eruption of Mount Pinatubo, which was a large stratospheric aerosol injection. We explore the climate pathway associated with the eruption from aerosols to radiation to temperature at both the near-surface and stratospheric levels. In addition to applying the method to data generated from two different ESMs, we apply stZFI to reanalysis data to compare the associations identified by stZFI. We show how stZFI tracks the importance of aerosol optical depth over time on forecasting temperatures. This case study illustrates usefulness of an ML tool (stZFI) for EDA on a well-studied climate exemplar.

Ries, Daniel (ORCID:0000000250294647)↗

A diagnostic system for electrical faults in a high current discharge plasma setup

A diagnostic system to detect electrical faults inside a coaxial high current discharge device is presented here. This technique utilizes two biconical antennas picking up electromagnetic radiation from the discharge device, a voltage divider sensing input voltage, and a Rogowski coil measuring the main discharge current. A computer program then analyses frequency components in these signals and provides information as to whether the discharge event was normal or any breakdown fault occurred inside the coaxial device. The diagnostic system is developed for a 450 kV and 50 kA capillary discharge plasma setup. For the setup various possible faults are analyzed by electrical simulation, followed by experimental results. In the case of normal discharge through the capillary load the dominant frequency is {approx}4 MHz. Under faulty conditions, the peak in magnitude versus frequency plot of the antenna signal changes according to the fault position which involves different paths causing variation in the equivalent circuit elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent Lidar Design and Performance Verification

This final report summarizes the investigative results from the 3 complete years of funding and corresponding publications are listed. The first year saw the verification of beam alignment for coherent Doppler lidar in space by using the surface return. The second year saw the analysis and computerized simulation of using heterodyne efficiency as an absolute measure of performance of coherent Doppler lidar. A new method was proposed to determine the estimation error for Doppler lidar wind measurements without the need for an independent wind measurement. Coherent Doppler lidar signal covariance, including wind shear and turbulence, was derived and calculated for typical atmospheric conditions. The effects of wind turbulence defined by Kolmogorov spatial statistics were investigated theoretically and with simulations. The third year saw the performance of coherent Doppler lidar in the weak signal regime determined by computer simulations using the best velocity estimators. Improved algorithms for extracting the performance of velocity estimators with wind turbulence included were also produced.

Frehlich, Rod↗

Generalizability analysis of tool condition monitoring ensemble machine learning models

Tool condition monitoring (TCM) is an essential research area for the optimization and automation of metal machining processes, and could help manufacturers reduce costs, production time, machine downtime, energy use, and part scrappage. However, TCM systems developed in prior studies have struggled to reach the high level of generalizability which is necessary for industrial applications. This study addresses TCM system generalizability to new machining conditions, how variations in machining and environmental conditions may be used to improve model generalizability, and ensemble machine learning techniques for TCM. Further, milling tool life experiments were conducted using various machining conditions, and the processes' sound, spindle power, and axial load signals were collected. Different machine learning models were evaluated for the prediction of tool wear levels, including four individual models and five ensemble models. Changes in cutting speed were found to display a large effect on model performance, while the chip load showed some effect, and the feed rate had little effect. A simulated noise data augmentation technique for model improvement is applied within TCM for the first time, and resulted in increased model generalizability and reduced overfitting. Across several performance metrics the extremely randomized trees ensemble machine learning model generally performed the best for this application, achieving a leave-one-group-out cross validation accuracy score of 92.4 %, a 10-fold cross validation score of 98.9 %, and an averaged accuracy across 11 generalizability tests of 87.3 %.

42 ENGINEERING↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. It has been estimated that once the fiber-optic gauges are put into operation, it should be possible to determine fluid masses with 3 percent or less. It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank supporting legs.

Figueroa, Jorge↗

Caution and Warning Alarm Design and Evaluation for NASA CEV Auditory Displays: SHFE Information Presentation Directed Research Project (DRPP) report 12.07

The design of caution-warning signals for NASA s Crew Exploration Vehicle (CEV) and other future spacecraft will be based on both best practices based on current research and evaluation of current alarms. A design approach is presented based upon cross-disciplinary examination of psychoacoustic research, human factors experience, aerospace practices, and acoustical engineering requirements. A listening test with thirteen participants was performed involving ranking and grading of current and newly developed caution-warning stimuli under three conditions: (1) alarm levels adjusted for compliance with ISO 7731, "Danger signals for work places - Auditory Danger Signals", (2) alarm levels adjusted to an overall 15 dBA s/n ratio and (3) simulated codec low-pass filtering. Questionnaire data yielded useful insights regarding cognitive associations with the sounds.

Durand R Begault↗

GILZ overexpression attenuates endoplasmic reticulum stress-mediated cell death via the activation of mitochondrial oxidative phosphorylation

The Glucocorticoïd-induced leucine zipper (GILZ) protein has profound anti-inflammatory activities in haematopoietic cells. GILZ regulates numerous signal transduction pathways involved in proliferation and survival of normal and neoplastic cells. Here, we have demonstrated the potential of GILZ in alleviating apoptosis induced by ER stress inducers. Whereas the glucocorticoid, dexamethasone, protects from tunicamycin-induced cell death, silencing endogeneous GILZ in dexamethasone-treated cancer cells alter the capacity of glucocorticoids to protect from tunicamycin-mediated apoptosis. Under ER stress conditions, overexpression of GILZ significantly reduced activation of mitochondrial pathway of apoptosis by maintaining Bcl-xl level. GILZ protein affects the UPR signaling shifting the balance towards pro-survival signals as judged by down-regulation of CHOP, ATF4, XBP1s mRNA and increase in GRP78 protein level. Interestingly, GILZ sustains high mitochondrial OXPHOS during ER stress and cytoprotection mediated by GILZ is abolished in cells depleted of mitochondrial DNA, which are OXPHOS-deficient. These findings reveal a new role of GILZ, which acts as a cytoprotector against ER stress through a pathway involving mitochondrial OXPHOS. - Highlights: • GILZ attenuates apoptotic cell death induced by ER stress conditions. • GILZ promotes pro-survival signaling of the UPR. • GILZ overexpression sustains high mitochondrial activity under ER stress. • Mitochondrial OXPHOX is required for GILZ protective effects against ER stress-mediated apoptosis.

60 APPLIED LIFE SCIENCES↗

Evaluation of pulsed RFI effects on digital satellite repeaters

This paper presents an analytical approach for assessing the effect of pulsed RFI on the error probability of a coherent phase-shift keyed signal through a nonlinear satellite repeater. The RFI is assumed to affect the uplink channel and to consist of CW pulses with random power levels and arriving randomly in time with a Poisson distribution. A model to approximate the effect of intermodulation products is introduced and the error probability conditioned on the output of the satellite repeater is computed. The classical moment technique is then used as an efficient method of averaging the conditional error probability over the numerous random parameters associated with the uplink signal.

Huang, T. C.↗