A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the resolution of dual readout calorimeters

Dual readout calorimeters allow state-of-the-art resolutions for hadronic energy measurements. Their various incarnations are leading candidates for the calorimeter systems for future colliders. In this paper, we present a simple formula for the resolution of a dual readout calorimeter, which we verify with a toy simulation and with full simulation results. This formula can help those new to dual readout calorimetry understand its strengths and limitations. The paper also highlights that the dual readout correction works not just to compensate for binding energy loss, but also for energies escaping the calorimeter or clustering algorithm. Formulae are also presented for approximate resolutions and energy scales in terms of different sources of response.

Calorimeters↗

A new framework to map fine resolution cropping intensity across the globe: Algorithm, validation, and implication

We report accurate estimation of cropping intensity (CI), an indicator of food production, is well aligned with the ongoing efforts to achieve sustainable development goals (SDGs) under diminishing natural resources. The advancement in satellite remote sensing provides unprecedented opportunities for capturing CI information in a spatially continuous manner. However, challenges remain due to the lack of generalizable algorithms for accurately and efficiently mapping global CI with a fine spatial resolution. In this study, we developed a 30-m planetary-scale CI mapping framework with the reconstructed time series of Normalized Difference Vegetation Index (NDVI) from multiple satellite images. Using a binary crop phenophase profile indicating growing and non-growing periods, we estimated pixel-by-pixel CI by enumerating the total number of valid cropping cycles during the study years. Based on the Google Earth Engine cloud computing platform, we implemented the framework to estimate CI during 2016–2018 in eight geographic regions across continents that are representative of global cropping system diversity. Comparison with PhenoCam network data in four cropland sites suggests that the proposed framework is capable of capturing the seasonal dynamics of cropping practices. Spatially, overall accuracies based on validation samples range from 80.0% to 98.9% across different regions worldwide. Regarding the CI classes, single cropping systems are associated with more robust and less biased estimations than multiple cropping systems. Finally, our CI estimates reveal high agreement with two widely used land surface phenology products, including Vegetation Index and Phenology V004 (VIP4) and Moderate Resolution Imaging Spectroradiometer Land Cover Dynamics (MCD12Q2), meanwhile providing much more spatial details. Due to its robustness, the developed CI framework can be potentially generalized to produce global fine resolution CI products for food security and other applications.

54 ENVIRONMENTAL SCIENCES↗

Studying drought-induced forest mortality using high spatiotemporal resolution evapotranspiration data from thermal satellite imaging

Drought can have pervasive and wide-spread impacts to forest health, as evidenced in several severe events occurring over the recent decades. Extensive forest die-off due to drought can impair the ecological functioning of forests, impacting habitat, water yield and quality from forested lands, and altering forest fire dynamics and intensity. Satellite remote sensing provides an effective means for detecting and monitoring spatial patterns of forest mortality over large areas, exploiting free and open long-term image archives available at a range in spatial and temporal resolutions. While remotely sensed surface reflectances and vegetation indices have been widely used to study optical response of forest canopies to drought events, retrievals of evapotranspiration (ET) derived from thermal satellite imagery – particularly at resolutions approaching crown scale - can provide insights into cumulative tree stresses that can incite disease and trigger mortality. In this study, we applied a multi-sensor satellite data fusion approach to estimate daily 30-m resolution ET and an associated Evaporative Stress Index (ESI) to study drought-induced mortality in a temperate forest at the Missouri Ozark AmeriFlux (MOFLUX) site, located in the central United States. The study covered the period from 2010 to 2014, including an exceptional drought year of 2012. Modeled ET agreed well with eddy flux measurements from the MOFLUX tower, with average monthly relative errors of 15%. Plot-scale ESI, describing temporal anomalies in the ratio of actual-to-reference ET, was used as an index of relative forest health to investigate relationships between forest mortality and drought severity. ESI showed good agreement with observed predawn leaf water potential, especially during the drought year. Furthermore, plot-scale ESI was also correlated with the subsequent year's tree mortality, suggesting the importance of considering the forest health condition prior to drought when studying drought-induced forest impacts. This study demonstrates the utility of multi-year ET remote sensing data at the stand or plot scale as an indicator of forest health and as a predictor of future mortality due to drought.

54 ENVIRONMENTAL SCIENCES↗

Progress in ultrahigh energy resolution EELS

Electron energy loss spectroscopy (EELS) in the electron microscope has progressed remarkably in the last five years. Advances in monochromator and spectrometer design have improved the energy resolution attainable in a scanning transmission electron microscope (STEM) to 4.2 meV, and new applications of ultrahigh energy resolution EELS have not lagged behind. They include vibrational spectroscopy in the electron microscope, a field that did not exist 5 years ago but has now grown very substantially. Notable examples include vibrational mapping with about 1 nm spatial resolution, analyzing the momentum dependence of vibrational states in very small volumes, determining the local temperature of the sample from the ratio of energy gains to energy losses, detecting hydrogen and analyzing its bonding, probing radiation-sensitive materials with minimized damage by aloof spectroscopy and leap-frog scanning, and identifying biological molecules with different isotopic substitutions. As a result, we review the instrumentation advances, provide a summary of key applications, and chart likely future directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The internal architecture of dendritic spines revealed by super-resolution imaging: What did we learn so far?

The molecular architecture of dendritic spines defines the efficiency of signal transmission across excitatory synapses. It is therefore critical to understand the mechanisms that control the dynamic localization of the molecular constituents within spines. However, because of the small scale at which most processes within spines take place, conventional light microscopy techniques are not adequate to provide the necessary level of resolution. Recently, super-resolution imaging techniques have overcome the classical barrier imposed by the diffraction of light, and can now resolve the localization and dynamic behavior of proteins within small compartments with nanometer precision, revolutionizing the study of dendritic spine architecture. Here, we highlight exciting new findings from recent super-resolution studies on neuronal spines, and discuss how these studies revealed important new insights into how protein complexes are assembled and how their dynamic behavior shapes the efficiency of synaptic transmission.

60 APPLIED LIFE SCIENCES↗

High-Resolution Field Emission Scanning Electron Microscopy (FESEM) Imaging of Cellulose Microfibril Organization in Plant Primary Cell Walls

Abstract We have used field emission scanning electron microscopy (FESEM) to study the high-resolution organization of cellulose microfibrils in onion epidermal cell walls. We frequently found that conventional “rule of thumb” conditions for imaging of biological samples did not yield high-resolution images of cellulose organization and often resulted in artifacts or distortions of cell wall structure. Here we detail our method of one-step fixation and dehydration with 100% ethanol, followed by critical point drying, ultrathin iridium (Ir) sputter coating (3 s), and FESEM imaging at a moderate accelerating voltage (10 kV) with an In-lens detector. We compare results obtained with our improved protocol with images obtained with samples processed by conventional aldehyde fixation, graded dehydration, sputter coating with Au, Au/Pd, or carbon, and low-voltage FESEM imaging. The results demonstrated that our protocol is simpler, causes little artifact, and is more suitable for high-resolution imaging of cell wall cellulose microfibrils whereas such imaging is very challenging by conventional methods.

biofuels (including algae and biomass), bio-inspir↗

Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint

Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.

BASIC BIOLOGICAL SCIENCES,MATERIALS SCIENCE↗

Achieving High-Resolution Hard X-ray Microscopy using Monolithic 2D Multilayer Laue Lenses

This article introduces the 2D multilayer Laue lens (MLL) nanofocusing optics recently developed for high-resolution hard X-ray microscopy. The new optics utilized a micro-electro-mechanical-system (MEMS)-based template to accommodate two linear MLL optics in a pre-aligned configuration. Angular misalignment between the two lenses was controlled in tens of millidegrees, and the lateral position error was on a micrometer scale. Using the developed 2D MLLs, an astigmatism-free point focus of approximately 14 nm by 13 nm in horizontal and vertical directions, respectively, at 13.6 keV photon energy was obtained. In conclusion, the success of 2D MLL optics with an approaching 10 nm resolution is a significant step forward for the development of high-resolution hard X-ray microscopy and applications of MLL optics in the hard X-ray community.

36 MATERIALS SCIENCE↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral Narrowing Accompanies Enhanced Spatial Resolution in Saturated Coherent Anti-Stokes Raman Scattering (CARS): Comparisons of Experiment and Theory

Here, we demonstrate theoretically and confirm experimentally the mechanism by which spectral narrowing accompanies enhanced spatial resolution in a saturated coherent anti-Stokes Raman scattering (CARS) signal that is demodulated at the third harmonic (3$f$) of the pump modulation frequency ($f$). Under these modulation conditions, theory predicts a narrowing of the full-width at half-maximum (FWHM) of the CARS spectrum by a factor of 2.0 with respect to that of the spectrum obtained by demodulation at the fundamental frequency. Theory also predicts an improvement of spatial resolution by a factor of 1.7. Experimentally, narrowing of the FWHM of the CARS spectrum of 1,4-bis((E)-2-methylstyryl) benzene (MSB) crystals by a factor of 2.5 is observed upon saturation. Further experimental confirmation is provided from investigating diamond particles, for which spectral narrowing was enhanced by a factor of 2.8 and spatial resolution was enhanced by a factor of 2. Details of the mechanism and execution of the saturated CARS experiment are elucidated and limits to its applicability are suggested, one of which is the conclusion that the saturation approach is not suitable for extraction of harmonics beyond 3$f$ . In this work we have developed a more comprehensive understanding of the correlation between the observed experimental results and experimental factors than has been previously reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatially Resolved Mapping of Three-Dimensional Molecular Orientations with ~2 nm Spatial Resolution through Tip-Enhanced Raman Scattering

We record local optical field images of silver nanocubes (75 nm) using tip-enhanced Raman (TER) spectral imaging. The images that we observe are consistent with several recent reports from our group, but here, we demonstrate sub-2 nm spatial resolution in local optical field nanoimaging under ambient laboratory conditions. This is achieved by scanning the substrate (nanocube on Si) relative to a 4-thiobenzonitrile (TBN)-functionalized Ag-coated TER probe. The spatial resolution that we obtain necessitates that only a few molecules govern the recorded optical response; molecular orientation becomes an important consideration in such measurements. We model the orientation through geometry optimization of a TBN molecule chemisorbed onto an Ag79 cluster (sphere with a ~1 nm diameter). Using the computed orientation of the cluster-bound molecule, we then model the optical response using formalism that accounts for the orientation of the molecule relative to vector components of the local optical fields. We find optimal agreement between experiment and theory. In effect, this work reveals the parallels between single-molecule Raman scattering and high-spatial-resolution TER spectroscopy, even when the images themselves cannot be used to visualize a single molecule in real space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Light Atoms at Subnanometer Resolution: Realization of Scanning Transmission Electron Microscope Holography

Atomic resolution imaging of light elements in electron-transparent materials has long been a challenge. Biomolecular materials, for example, are rapidly altered by incident electrons. We demonstrate a scanning transmission electron microscopy (STEM) technique, called STEM holography, capable of efficient structural analysis of beam-sensitive nanomaterials. STEM holography measures the absolute phase and amplitude of electrons passed through a specimen via interference with a vacuum reference wave. We use an amplitude-dividing nanofabricated grating to prepare multiple beams focused at the sample. We configure the postspecimen microscope imaging system to overlap the beams, forming an interference pattern. We record and analyze the pattern at each 2D-raster-scan-position, reconstructing the complex object wave. As a demonstration, we image gold nanoparticles on an amorphous carbon substrate at 2.4 Å resolution. In conclusion STEM holography offers higher contrast of the carbon while maintaining gold atomic lattice resolution compared to high angle annular dark field STEM.

4D-STEM↗

Tip-Enhanced Raman Chemical and Chemical Reaction Imaging in H 2 O with Sub-3-nm Spatial Resolution

Reproducible chemical and chemical reaction nano-imaging at solid-liquid interfaces remains challenging, particularly when resolutions on the order of a few nm are sought after. In this work, we demonstrate the latter through liquid tip-enhanced Raman (TER) measurements that target gold nanoplates functionalized with 4-mercaptobenzonitrile (MBN). In addition to chemical imaging and local optical field nano-visualization with high spatial resolution, we observe the signatures of 4-mercaptobenzoic acid, which forms as a result of plasmon-induced hydrolysis of MBN. Evidently, the solvent leads to distinct plasmon-induced/enhanced chemical reaction pathways that have not been documented. Here this work shows that such reactions that take place at solid-liquid interfaces can be tracked with a record sub-3 nm spatial resolution via TER spectral nano-imaging in liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnosis of ULF Wave-Particle Interactions With Megaelectron Volt Electrons: The Importance of Ultrahigh-Resolution Energy Channels

Electron flux measurements are an important diagnostic for interactions between ultralow-frequency (ULF) waves and relativistic (~1 MeV) electrons. Since measurements are collected by particle detectors with finite energy channel width, they are affected by a phase mixing process that can obscure these interactions. In this paper, we demonstrate that ultrahigh-resolution electron measurements from the Magnetic Electron Ion Spectrometer on the Van Allen Probes mission—obtained using a data product that improves the energy resolution by roughly an order of magnitude—are crucial for understanding ULF wave-particle interactions. In particular, the ultrahigh-resolution measurements reveal a range of complex dynamics that cannot be resolved by standard measurements. Furthermore, the standard measurements provide estimates for the ULF flux modulation amplitude, period, and phase that may not be representative of true flux modulations, potentially leading to ambiguous conclusions concerning electron dynamics.

42 ENGINEERING↗

Evaluating Variable‐Resolution CESM Over China and Western United States for Use in Water‐Energy Nexus and Impacts Modeling

Abstract Climate models are critical tools to study earth system processes and are often further downscaled to provide refined‐resolution data sets for regional water‐energy impact analyses. In this study, the Variable‐Resolution Community Earth System Model (VR‐CESM), a new dynamical downscaling method, is employed to generate 1/8° simulations for China and the western United States over 1970–2006. Precipitation, temperature, snowpack, radiation, and wind speed are compared with two 1° global climate models, regional climate model ensemble, and reference data sets to evaluate their fidelity. Simulated precipitation skill is dependent upon the reference data sets used, a slight (<+10%) and spatially consistent wet bias in China during summer and the western United States during winter. Precipitation bias in VR‐CESM is the smallest among models and demonstrates the added value provided by resolution refinement. However, temperature biases are generally greater than precipitation due to more complicated interactions among processes. VR‐CESM simulates +2°C warm bias in the low‐elevation regions in China but −2°C cold bias in mountains. However, DJF cold bias (−2.23°C to−3.37°C) and JJA warm bias (+1.13°C to +1.87°C) exist in the western United States. The modeling skills of precipitation and temperature at various topographies are similar in the two evaluated regions. The cold bias was likely affected by downward shortwave radiation deficit (−15%) and slow bias of surface wind speeds (−16% to −29%). Despite the wet and cold bias, snow water equivalent and snow cover are underestimated in mountains. We conclude that VR‐CESM outperforms other models evaluated and provides the best estimation of downscaled climate model data for water‐energy studies.

54 ENVIRONMENTAL SCIENCES↗