Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Processing Methodology for Double Sensor Probe in a Bubbly Flow

Bubbly flow phenomenon is the most common flow pattern in nuclear plant system. In this paper, according to Hibiki and Bartel, the experiment was designed to observe the fluid conditions surrounding nuclear rod. In recent years, double sensor probe is one of the measuring techniques for the bubbly flow. It can measure local void fraction and bubble velocity. After mathematical statistical calculation, interfacial area concentration is obtained by Kataoka. The double sensor probe method, with the advantage for measuring local interfacial area concentration, has become widely used in many measurement methods. The paper of Liu and Zhao were referred to establish the post-processing for the raw data obtained from measuring instrument. After drawing the signal of the probe, it is important to analyze the raw data for the elimination of unnecessary noise signal and highlight the characteristic signal. Based on the same experimental condition, the different filtering methods, Simple Moving Average (SMA) and Gaussian average, were compared and discussed by the double sensor probe.

42 ENGINEERING↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Probe for selectively characterizing enzymes involved in xenobiotic metabolism and method of making and using the same

Activity-based probes that can be used to selectively identify and characterize enzymes that are involved in different phases of xenobiotic metabolism in a host and its microbiota population(s) are described. The activity-based probes described specifically label only their target active enzymes involved in xenobiotic metabolism and therefore provide a measurement of true protein functional activity rather than transcript or protein abundance. The activity-based probes also provide multimodal profiling of these active enzymes. Methods for preparing the activity based probes and exemplary methods for their use also are disclosed.

Wright, Aaron T.↗

Capture probe

A system and method for sampling a sample material includes a device for directing sample into a capture probe. The device for supplying sample material to the probe can be a device for radiating energy to the sample material to eject sample from the sample material. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate such that gas with sample is withdrawn with the liquid.

Kertesz, Vilmos↗

Constraints on Dynamical Dark Energy from Multiple Probes in the Full Dark Energy Survey

We present results on dark energy evolution, assuming a time-dependent equation of state $w(a)=w_0+w_a(1-a)$, from growth and geometric probes using the full six-year Dark Energy Survey dataset: type Ia supernovae, baryon acoustic oscillations, and weak gravitational lensing and galaxy clustering (3$\times$2pt). The combination yields $w_0=-0.84^{+0.10}_{-0.10}$ and $w_a=-0.44^{+0.60}_{-0.55}$, the tightest constraints ever obtained from a single survey, with $2.2σ$ deviation from a cosmological constant. Adding the DESI DR2 BAO data yields $w_0=-0.84^{+0.06}_{-0.07}$ and $w_a=-0.53^{+0.33}_{-0.28}$, representing the most stringent low-redshift-only test of dynamical dark energy to date, with a $2.3σ$ deviation. In this combination, adding 3$\times$2pt doubles the constraining power. Finally, when combined with primary CMB information, we obtain $w_0=-0.82^{+0.05}_{-0.05}$, $w_a=-0.63^{+0.21}_{-0.18}$, with a $3.0σ$ deviation. We find that including 3$\times$2pt in the previously studied SN + DESI BAO + CMB combination leaves the significance essentially unchanged ($3.2 σ$ to $3.0σ$) while improving the figure of merit by $\sim$10%. We systematically investigate the impact of leaving out each one of the probes and find that the significance of the deviation from a cosmological constant ranges from 2.3 to 3.2$σ$, with best-fit parameters consistently in the region $w_0 >-1$ and $w_a <0$. Excluding SN from the all data combination yields a $2.6σ$ departure from $Λ$CDM, providing a cross-check independent of supernova photometric calibration. These results support the weak preference for evolving dark energy reported by several recent cosmological analyses. By combining growth and geometric probes from a single survey, this work realizes the multi-probe dark energy program envisioned at the inception of DES.

Abbott, T. M.C. [Cerro-Tololo InterAmerican Obs.] ↗

The approach to equilibrium during tempering of a bulk nanocrystalline steel: an atom probe investigation

A local electrode atom probe has been used to analyze the solute partitioning during bainite transformation in a novel, nanocrystalline bainitic steel. Atom probe results show the absence of any partitioning of substitutional elements between the phases involved. The results are fully consistent with the diffusionless transformation of austenite to bainite. However, substitutional elements are expected to redistribute approaching an equilibrium phase boundary as the mixture of bainitic ferrite and retained austenite is tempered. The compositional analysis of the austenite/ferrite interface by atom probe tomography indicates that retained austenite decomposes during tempering before equilibrium is reached at the interface.

36 MATERIALS SCIENCE↗

New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems

There has been a recent surge in the use of cryo and/or vacuum specimen preparation and transfer systems that are broadening the scope of research enabled by the microscopy technique of atom probe tomography. This is driven by the fact that, like for many microscopes, the application of atom probe to air and temperature sensitive materials or wet biological specimens has previously been limited by through-air-transfer and through-vacuum-transfer at room temperature. Here we provide an overview of the critical areas of research that require these new transfer and analysis protocols, as well as a review of current advances in transfer devices, environmental cells and glove boxes for controlled sample manipulation. This includes the study of catalysis and corrosion, the application of atom probe to biological samples, the study of liquid-solid interfaces, natural ageing investigations and the analysis of hydrogen in metals.

36 MATERIALS SCIENCE↗

Application of a Liquid Extraction Based Sealing Surface Sampling Probe for Mass Spectrometric Analysis of Dried Blood Spots and Mouse Whole-Body Thin Tissue Sections

The utility of a liquid extraction based sealing surface sampling probe (SSSP) for the direct mass spectrometric analysis of targeted drugs and metabolites in dried blood spots (DBSs) and whole mouse thin tissue sections was demonstrated. The accuracy and precision for the quantitative analysis of a minimum of 50 ng/mL sitamaquine or acetaminophen in DBSs on paper were well within the required 15% dictated by internationally recognized acceptance criteria for assay validations. Analysis of whole-body mouse thin tissue sections from animals dosed with propranolol, adhered to an adhesive tape substrate, provided semi-quantitative information for propranolol and its hydroxyproranolol glucuronide metabolite within specific organs of the tissue. The relative abundances recorded for the two compounds in the brain, lung, kidney and liver were in nominal agreement with previously reported amounts based on analysis using a liquid microjunction surface sampling probe (LMJ-SSP), and whole-body autoradiography (WBA) and HPLC-MS analysis. The ability to sample and analyze from tape-adhered tissue samples, which are generally employed in WBA analysis, presents the possibility of consecutive WBA and SSSP-MS analysis of the same tissue section. This would facilitate assignment, and possibly quantitation, of the different molecular forms of total drug related material detected in the WBA analysis. The flexibility to sample larger or smaller spot sizes, alternative probe sealing mechanisms, and a reduction in internal volumes and associated sample carryover issues will be among the first simple improvements necessary to make the SSSP-MS method a practical DBS and/or thin tissue section analysis tool or to expand its use to other surface sampling applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved Electrical Scanning Probe Microscopy of Layered Perovskites Reveals Spatial Variations in Photoinduced Ionic and Electronic Carrier Motion

We study light-induced dynamics in thin films comprising Ruddlesden–Popper phases of the layered 2D perovskite (C 4 H 9 NH 3 ) 2 PbI 4 . We probe ionic and electronic carrier dynamics using two complementary scanning probe methods, time-resolved G-mode Kelvin probe force microscopy and fast free time-resolved electrostatic force microscopy, as a function of position, time, and illumination. Here, we show that the average surface photovoltage sign is dominated by the band bending at the buried perovskite–substrate interface. However, the film exhibits substantial variations in the spatial and temporal response of the photovoltage. Under illumination, the photovoltage equilibrates over hundreds of microseconds, a time scale associated with ionic motion and trapped electronic carriers. Surprisingly, we observe that the surface photovoltage of the 2D grain centers evolves more rapidly in time than at the grain boundaries. We propose that the slower evolution at grain boundaries is due to a combination of ion migration occurring between PbI 4 planes, as well as electronic carriers traversing grain boundary traps, thereby changing the time-dependent band unbending at grain boundaries. These results provide a model for the photoinduced dynamics in 2D perovskites and are a useful basis for interpreting photovoltage dynamics on hybrid 2D/3D structures.

14 SOLAR ENERGY↗

Digital smoothing of the Langmuir probe I-V characteristic

Electrostatic probes or Langmuir probes are the most common diagnostic tools in plasma discharges. The second derivative of the Langmuir probe I-V characteristic is proportional to the electron energy distribution function. Determining the second derivative accurately requires some method of noise suppression. We compare the Savitzky-Golay filter, the Gaussian filter, and polynomial fitting to the Blackman filter for digitally smoothing simulated and measured I-V characteristics. We find that the Blackman filter achieves the most smoothing with minimal distortion for noisy data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-Particles as Electrostatic Probes for Plasma Sheath Diagnostic

An interesting aspect in the research of complex (dusty) plasmas is the experimental study of the interaction of micro-particles of different sizes with the surrounding plasma for diagnostic purpose. In the plasma micro-disperse particles are negatively charged and confined in the sheath. The particles are trapped by an equilibrium of gravity, electric field force and ion drag force. From the behavior, local electric fields can be determined, e.g. particles are used as electrostatic probes. In combination with additional measurements of the plasma parameters with Langmuir probes and thermal probes as well as by comparison with an analytical sheath model, the structure of the sheath can be described. In the present work we focus on the behavior of micro-particles of different sizes and several plasma parameters e.g. the gas pressure and the rf-power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpretation and implementation of an ion sensitive probe as a plasma potential diagnostic

An ion sensitive probe (ISP) is developed as a robust diagnostic for measuring plasma potentials ({Phi}{sub P}) in magnetized plasmas. The ISP relies on the large difference between the ion and electron gyroradii ({rho}{sub i}/{rho}{sub e}{approx}60) to reduce the electron collection at a collector recessed behind a separately biased wall distance {approx}{rho}{sub i}. We develop a new ISP method to measure the plasma potential that is independent of the precise position and shape of the collector. {Phi}{sub P} is found as the wall potential when charged current to the probe collector vanishes during the voltage sweep. The plasma potentials obtained from the ISP match {Phi}{sub P} measured with an emissive probe over a wide range of plasma conditions in a small magnetized plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-controlled pulse propagation in media with cross coupling of electric and magnetic probe field component

Light propagation is discussed in media with a cross coupling of the electric and magnetic component of an applied probe field. We derive the wave equations for a probe pulse propagating through such a medium and solve them analytically in Fourier space using the slowly varying envelope approximation. Our analysis reveals the influence of the different medium response coefficients on the propagation dynamics. We apply these results to a specific example system in which cross couplings are induced in an atomic medium by additional control fields. We show that the cross couplings render the propagation dynamics sensitive to the relative phase of the additional fields, and this phase dependence enables one to control the pulse during its propagation through the medium. Our results demonstrate that the magnetic field component of a probe beam can crucially influence the system dynamics already at experimentally accessible parameter ranges in dilute vapors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic probe measurements of the current sheath on the PF-3 facility

Results are presented from experimental studies of the dynamics of the current sheath (CS) on the PF-3 plasma focus facility. The parameters of the sheath, including the current distribution in it, were measured using absolutely calibrated magnetic probes installed at different positions with respect to the facility axis and the anode surface. The CS dynamics in discharges operating in argon and neon was investigated, and the skin depth in different stages of the discharge was determined. One of the probes was installed at a distance of {approx}2 cm from the facility axis, which made it possible to estimate the efficiency of current transfer to the region of pinch formation. Operating modes were obtained in which the current dynamics detected by magnetic probes at different distances from the axis agreed well with the dynamics of the total discharge current until the instant of singularity in the current time derivative. It is shown that shunting breakdowns can lead to the formation of closed current loops. The shunting of the discharge current by the residual plasma is directly related to the efficiency of snowplowing of the working gas by the CS as it propagates from the insulator toward the facility axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved probing of laser-induced nanostructuring processes in liquids

Laser synthesis and processing of colloids (LSPC) in liquids has gained widespread applications in producing nanomaterials of different classes of solids. While the technical processes in different cases of ablation, fragmentation or colloidal fusion may look macroscopically different in each application, the underlying fundamental mechanisms are always the same cascade of laser interaction with matter, non-thermal or thermal energy deposition, phase transitions, and the subsequent structure formation processes. Disentangling these mechanisms represents a veritable challenge, as ultrafast and structurally sensitive experimental methods are required. This review presents a discussion of how state-of-the-art experimental protocols using ultrafast lasers and sensitive structural probes, such as electrons or X-rays are able to address this challenge. In particular, it is possible to investigate LSPC on single objects using single probe pulses and avoid accumulation effects in a heterogeneous sample. The presented results capture structure formation with femtosecond and atomic scale resolution. Ultrafast time-resolved probing approaches are key to revealing the transient states and pathways that govern material transformation in LSPC.

X-ray scattering↗

Van Allen Probes, THEMIS, GOES, and cluster observations of EMIC waves, ULF pulsations, and an electron flux dropout

We examined an electron flux dropout during the 12–14 November 2012 geomagnetic storm using observations from seven spacecraft: the two Van Allen Probes, Time History of Events and Macroscale Interactions during Substorms (THEMIS)-A (P5), Cluster 2, and Geostationary Operational Environmental Satellites (GOES) 13, 14, and 15. The electron fluxes for energies greater than 2.0 MeV observed by GOES 13, 14, and 15 at geosynchronous orbit and by the Van Allen Probes remained at or near instrumental background levels for more than 24 h from 12 to 14 November. For energies of 0.8 MeV, the GOES satellites observed two shorter intervals of reduced electron fluxes. The first interval of reduced 0.8 MeV electron fluxes on 12–13 November was associated with an interplanetary shock and a sudden impulse. Cluster, THEMIS, and GOES observed intense He + electromagnetic ion cyclotron (EMIC) waves from just inside geosynchronous orbit out to the magnetopause across the dayside to the dusk flank. The second interval of reduced 0.8 MeV electron fluxes on 13–14 November was associated with a solar sector boundary crossing and development of a geomagnetic storm with Dst <–100 nT. At the start of the recovery phase, both the 0.8 and 2.0 MeV electron fluxes finally returned to near prestorm values, possibly in response to strong ultralow frequency (ULF) waves observed by the Van Allen Probes near dawn. A combination of adiabatic effects, losses to the magnetopause, scattering by EMIC waves, and acceleration by ULF waves can explain the observed electron behavior.

58 GEOSCIENCES↗

The occurrence and wave properties of H⁺-, He⁺-, and O⁺-band EMIC waves observed by the Van Allen Probes

We perform a statistical study of electromagnetic ion cyclotron (EMIC) waves detected by the Van Allen Probes mission to investigate the spatial distribution of their occurrence, wave power, ellipticity, and normal angle. The Van Allen Probes have been used which allow us to explore the inner magnetosphere (1.1 to 5.8 RE). Magnetic field measurements from the Electric and Magnetic Field Instrument Suite and Integrated Science on board the Van Allen Probes are used to identify EMIC wave events for the first 22 months of the mission operation (8 September 2012 to 30 June 2014). EMIC waves are examined in H⁺-, He⁺-, and O⁺-bands. Over 700 EMIC wave events have been identified over the three different wave bands (265 H⁺-band events, 438 He⁺-band events, and 68 O⁺-band events). EMIC wave events are observed between L = 2 – 8, with over 140 EMIC wave events observed below L = 4. The results show that H⁺-band EMIC waves have two peak magnetic local time (MLT) occurrence regions: pre-noon (09:00 < MLT ≤ 12:00) and afternoon (15:00 < MLT ≤ 17:00) sectors. He⁺-band EMIC waves feature an overall stronger dayside occurrence. O⁺-band EMIC waves have one peak region located in the morning sector at lower L shells (L < 4). He⁺-band EMIC waves average the highest wave power overall (>0.1 nT²/Hz), especially in the afternoon sector. Ellipticity observations reveal that linearly polarized EMIC waves dominate in lower L shells.

58 GEOSCIENCES↗

Multifunctional Biomedical Imaging in Physiological and Pathological Conditions Using a NIR-II Probe

Contrasted with imaging in the visible (400–650 nm) and near-infrared window I (NIR-I, 650–900 nm) regions, imaging in near-infrared window II (NIR-II, 1000–1700 nm) is a highly promising in vivo imaging modality with improved resolution and deeper tissue penetration. Here, a small molecule NIR-II dye,5,5'-(1H,5H-benzo[1,2-c:4,5-c'] bis[1,2,5]thiadiazole)-4,8-diyl)bis(N,N-bis(4-(3-((tert-butyldimethylsilyl)oxy)propyl)phenyl) thiophen-2-amine), is successfully encapsulated into phospholipid vesicles to prepare a probe CQS1000. The novel NIR-II probe is studied for in vivo multifunctional biological imaging. The results of this study indicate that the NIR-II vesicle CQS1000 can noninvasively and dynamically visualize and monitor many physiological and pathological conditions of circulatory systems, including lymphatic drainage and routing, angiogenesis of tumor, and vascular deformity such as arterial thrombus formation and ischemia with high spatial and temporal resolution. More importantly, by virtue of the favorable half-life of blood circulation of CQS1000, NIR-II imaging is capable of aiding precise resection of tumor such as osteosarcoma and accelerating the process of lymph node dissection to complete sentinel lymph node biopsy for better decision making during the tumor surgery. Overall, CQS1000 is a highly promising NIR-II probe for multifunctional biomedical imaging in physiological and pathological conditions, surpassing traditional NIR-I imaging modality and pathologic assessments for clinical diagnosis and treatment.

36 MATERIALS SCIENCE↗