Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Waiting for precise measurements of K{sup +}{yields}{pi}{sup +}{nu}{nu} and K{sub L}{yields}{pi}{sup 0}{nu}{nu}

In view of future plans for accurate measurements of the theoretically clean branching ratios Br(K{sup +}{yields}{pi}{sup +}{nu}{nu}) and Br(K{sub L}{yields}{pi}{sup 0}{nu}{nu}), which should occur in the next decade, the relevant formulas for quantities of interest are collected and their theoretical and parametric uncertainties are analyzed. In addition to the angle {beta} in the unitarity triangle (UT), the angle {gamma} can also be determined from these decays with respectable precision and in this context the importance of the recent NNLO QCD calculation on the charm contribution to K{sup +}{yields}{pi}{sup +}{nu}{nu} and of the improved estimate on the long-distance contribution by means of chiral perturbation theory are presented. In addition to known expressions, several new ones that should allow transparent tests of the standard model (SM) and of its extensions are presented. While the review is centered around the SM, models with minimal flavor violation and scenarios with new complex phases in decay amplitudes and meson mixing are also discussed. A review of existing results within specific extensions of the SM, in particular the littlest Higgs model with T-parity, Z{sup '} models, the MSSM, and a model with one universal extra dimension are given. A new ''golden'' relation between B and K systems is derived that involves ({beta},{gamma}) and Br(K{sub L}{yields}{pi}{sup 0}{nu}{nu}), and the virtues of (R{sub t},{beta}), (R{sub b},{gamma}), ({beta},{gamma}), and ({eta},{gamma}) strategies for the UT in the context of K{yields}{pi}{nu}{nu} decays with the goal of testing the SM and its extensions are investigated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise 𝐾* ⁡(892) → 𝐾⁡𝜋 branching fractions

Although discovered more than sixty years ago, direct measurement of the 𝐾*⁡(892) → 𝐾⁡𝜋 branching fractions is a formidable challenge that has not been attempted. Typically they are assumed to obey the isospin limit in hundreds of particle data measurements. We show that an abundance of recent amplitude analyses and other data, however, enables recovery of the ratios ℬ⁡(𝐾 *+ → 𝐾 + ⁢𝜋 0 )/ℬ⁡(𝐾 *+ → 𝐾$^0_S$ ⁢𝜋 + ) and 4⁢ℬ⁡(𝐾 *0 → 𝐾$^0_S$ ⁢𝜋 0 )/ℬ⁡(𝐾 *0 → 𝐾 +⁢ 𝜋 − ) at ∼5% precision.

Gligorov, Vladimir V. [Sorbonne Université, Paris ↗

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the 𝑁 = 28 shell closure

Although it is known that the N = 28 spherical shell closure erodes, the strength of the closure with decreasing proton number Z < 20 is an open question in nuclear structure. Here, in this region of interest, high-precision mass measurements of neutron-rich 43-45 Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME(⁴³Cl) = -24114.4(1.7) keV, ME(⁴⁴Cl) = -20450.8(10.6) keV, and ME(⁴⁵Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ∼40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to ab initio calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Erington, H. [Michigan State Univ., East Lansing, ↗

Precision measurement of the $Ξ^0_b$ baryon lifetime

A sample of 𝑝⁢𝑝 collision data, corresponding to an integrated luminosity of 5.4 fb −1 and collected by the LHCb experiment during LHC Run 2, is used to measure the ratio of the lifetime of the $Ξ^0_b$ baryon to that of the $Λ^0_b$ baryon, 𝑟 𝜏 $≡$ $𝜏_{Ξ^0_b}$$/𝜏_{Λ^0_b}$. The value 𝑟$^{\textrm{Run 2}}_𝜏$ =1.004 ± 0.009 ± 0.006 is obtained, where the first uncertainty is statistical and the second systematic. This value is averaged with the corresponding value from Run 1 to obtain 𝑟 𝜏 =1.004 ± 0.008 ± 0.005. Multiplying by the known value of the $Λ^0_b$ lifetime yields $𝜏_{Ξ^0_b}$ = 1.475 ± 0.012 ± 0.008 ± 0.009 ps, where the last uncertainty is due to the limited knowledge of the $Λ^0_b$ lifetime. This measurement improves the precision of the current world average of the $Ξ^0_b$ lifetime by about a factor of two, and is in good agreement with the most recent theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision study of the massive Schwinger model near quantum criticality

We perform a numerical analysis of the massive Schwinger model in the presence of a background electric field. Using the Density Matrix Renormalization Group approach, we efficiently compute the spectrum of the Schwinger model on a staggered lattice with up to 3000 qubits. As a result, we achieve a precise computation of the critical mass of the massive Schwinger model to five digits using four different “criticality criteria,” observing perfect agreement among them Additionally, we discuss the effect of a four-fermion operator deformation of the Schwinger model and compute the critical mass for various values of the deformation parameter.

Critical phenomena↗

Precision Measurement of Neutrino Oscillation Parameters with 10 Years of Data from the NOvA Experiment

This Letter reports measurements of muon-neutrino disappearance and electron-neutrino appearance and the corresponding antineutrino processes between the two NOvA detectors in the NuMI neutrino beam. These measurements use a dataset with double the neutrino mode beam exposure that was previously analyzed, along with improved simulation and analysis techniques. A joint fit to these samples in the three-flavor paradigm results in the most precise single-experiment constraint on the atmospheric neutrino mass-splitting, $Δm^2_{32}= 2.431^{+0.036}_{-0.034} (-2.479^{+0.036}_{-0.036}) \times 10^{-3}$~eV$^2$ if the mass ordering is Normal (Inverted). In both orderings, a region close to maximal mixing with $\sin^2θ_{23}=0.55_{+0.06}^{-0.02}$ is preferred. The NOvA data show a mild preference for the Normal mass ordering with a Bayes factor of 2.4 (corresponding to 70% of the posterior probability), indicating that the Normal ordering is 2.4 times more probable than the Inverted ordering. When incorporating a 2D $Δm^2_{32}\textrm{--}\sin^2 2θ_{13}$ constraint based on Daya Bay data, this preference strengthens to a Bayes factor of 6.6 (87\%).

FOS: Physical sciences↗

Remarkable Precision of the 90-Year-Old Dynamical Diffraction Theories of Darwin and Ewald

The reflectivity functions calculated by Bonse and Hart for a multi-bounce channel-cut single crystal following the 90-year-old Darwin and Ewald theories exhibit extremely narrow, nearly rectangular profiles. This feature provides ultra-high angular resolution and sensitivity for the double-crystal diffractometers now widely used for observation of large-scale structures in condensed matter. However, the experimental results are several orders of magnitude poorer than the theoretical prediction, the wings problem , and the reason for this discrepancy has remained unidentified for more than 40 years, creating problems for both theory and practice. Here we show a complete solution of this problem for neutron diffraction in Si channel-cut crystals. Our results allow obtaining nearly theoretical functions of multiple reflectivity, which demonstrates the remarkable precision of the Darwin and Ewald theories in the range of the wings and give rise to much improved sensitivity for the next generation of the Bonse-Hart double-crystal diffractometers.

99 GENERAL AND MISCELLANEOUS↗

Simultaneous multiplexed materials characterization using a high-precision hard X-ray micro-slit array

Here, the needs both for increased experimental throughput and for in operando characterization of functional materials under increasingly realistic experimental conditions have emerged as major challenges across the whole of crystallography. A novel measurement scheme that allows multiplexed simultaneous measurements from multiple nearby sample volumes is presented. This new approach enables better measurement statistics or direct probing of heterogeneous structure, dynamics or elemental composition. To illustrate, the submicrometer precision that optical lithography provides has been exploited to create a multiplexed form of ultra-small-angle scattering based X-ray photon correlation spectroscopy (USAXS-XPCS) using micro-slit arrays fabricated by photolithography. Multiplexed USAXS-XPCS is applied to follow the equilibrium dynamics of a simple colloidal suspension. While the dependence of the relaxation time on momentum transfer, and its relationship with the diffusion constant and the static structure factor, follow previous findings, this measurements-in-parallel approach reduces the statistical uncertainties of this photon-starved technique to below those associated with the instrument resolution. More importantly, we note the potential of the multiplexed scheme to elucidate the response of different components of a heterogeneous sample under identical experimental conditions in simultaneous measurements. Lastly, in the context of the X-ray synchrotron community, this scheme is, in principle, applicable to all in-line synchrotron techniques. Indeed, it has the potential to open a new paradigm for in operando characterization of heterogeneous functional materials, a situation that will be even further enhanced by the ongoing development of multi-bend achromat storage ring designs as the next evolution of large-scale X-ray synchrotron facilities around the world.

36 MATERIALS SCIENCE↗

Characterization of a quadrant diamond transmission X-ray detector including a precise determination of the mean electron–hole pair creation energy

Precise monitoring of the incoming photon flux is crucial for many experiments using synchrotron radiation. For photon energies above a few keV, thin semiconductor photodiodes can be operated in transmission for this purpose. Diamond is a particularly attractive material as a result of its low absorption. The responsivity of a state-of-the art diamond quadrant transmission detector has been determined, with relative uncertainties below 1% by direct calibration against an electrical substitution radiometer. From these data and the measured transmittance, the thickness of the involved layers as well as the mean electron–hole pair creation energy were determined, the latter with an unprecedented relative uncertainty of 1%. Lastly, the linearity and X-ray scattering properties of the device are also described.

47 OTHER INSTRUMENTATION↗

Fabrication and characterization of a full-size ultra-precise lamellar grating for the Cosmic beamline at ALS-U

We have developed a new process for the production of ultra-precise variable line spacing (VLS) lamellar diffraction gratings through nanofabrication. The process enables the fabrication of full-size X-ray gratings with sub-nanometre accuracy in groove depth, an optimal land-to-groove ratio, and uniform groove depth across the entire grating area. We also established a method for evaluating VLS groove density variation using stitched Fizeau interferometry. The measurements confirmed the exceptionally high accuracy of the VLS groove density in the fabricated gratings, which is well within the specification tolerances while the residual groove density errors are vanishingly small. The gold-coated grating demonstrated near-theoretical diffraction efficiency across the energy range of 100–1200 eV.

36 MATERIALS SCIENCE↗

Study of Fricke-gel dosimeter calibration for attaining precise measurements of the absorbed dose

A method has been studied for attaining, with good precision, absolute measurements of the spatial distribution of the absorbed dose by means of the Fricke gelatin Xylenol Orange dosimetric system. With this aim, the dose response to subsequent irradiations was analyzed. In fact, the proposed modality is based on a pre-irradiation of each single dosimeter in a uniform field with a known dose, in order to extrapolate a calibration image for a subsequent non-uniform irradiation with an un-known dose to be measured. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

High precision gate signal timing control based active voltage balancing scheme for series-connected fast switching field-effect transistors

Due to the low availability, high cost, and limited performance of high voltage power devices in high voltage high power applications, series-connection of low voltage switches is commonly considered. Practically, because of the dynamic voltage unbalance and the resultant reliability issue, switches in series-connection are not popular, especially for fast switching field-effect transistors such as silicon (Si) super junction MOSFETs, silicon carbide (SiC) JFETs, SiC MOSFETs, and gallium nitride (GaN) HEMTs, since their switching performance is highly sensitive to gate control, circuit parasitics, and device parameters. In the end, slight mismatch can introduce severe unbalanced voltage. This paper proposes an active voltage balancing scheme, including 1) tunable gate signal timing unit between series-connected switches with <; 1 ns precision resolution by utilizing a high resolution pulse-width modulator (HRPWM) which has existed in micro-controllers; and 2) online voltage unbalance monitor unit integrated with the gate drive as the feedback. Based on the latest generation 600-V Si CoolMOS, experimental results show that the dynamic voltage can be automatically well balanced in a wide range of operating conditions, and more importantly, the proposed scheme has no penalty for high-speed switching.

Zhang, Zheyu↗

VecPAC: A Vectorizable and Precision-Aware CGRA

This paper proposes VecPAC -- a vectorizable and precision-aware coarse-grained reconfigurable array (CGRA) design. VecPAC integrates CGRA tiles with scalar functional units and specialized tiles with vector functional units that can trade off the number of vector lanes for the accuracy of the computation. We discuss the architecture design and present the related compilation framework. The experimental evaluation on a set of applications from three different domains (embedded, machine learning, and high-performance computing) shows that the hybrid design of VecPAC outperforms CGRAs with only scalar functional units by 1.48x, while providing higher scalability.

Tan, Cheng↗

A Precision, Low-Cost GPS-Based Transmitter Synchronization Scheme for Improved AM Reception

This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to {approx}1 part in 10{sup 9} or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station's carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station's audio at the receiver and concurrent distortion of the audio modulation from the distant station(s) and often cause listeners to ldquotune outrdquo due to the low reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; hybrid digital (HD) signals will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1000-$2000), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long- term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific carrier frequency desired. The stability of the disciplining source, typically {approx}1 part in 10{sup 9} to 10{sup 11}, is thus transferred to the final AM transmitter carrier output frequency.

42 ENGINEERING↗

A Precision Dose Control Circuit for Maskless E-Beam Lithography With Massively Parallel Vertically Aligned Carbon Nanofibers

This paper describes a highly accurate dose control circuit (DCC) for the emission of a desired number of electrons from vertically aligned carbon nanofibers (VACNFs) in a massively parallel maskless e-beam lithography system. The parasitic components within the VACNF device cause a premature termination of the electron emission, resulting in underexposure of the photoresist. In this paper, we compensate for the effects of the parasitic components and noise while reducing the area of the chip and achieving a precise count of emitted electrons from the VACNFs to obtain the optimum dose for the e-beam lithography.

47 OTHER INSTRUMENTATION↗

A Novel Event Detection Method Using PMU Data with High Precision

To take full advantage of the considerably high reporting rate of phasor measurement units (PMU) data, this paper develops a novel PMU-based event detection methodology. Considering the huge amount of streaming PMU data, a data compression algorithm, swinging door trending (SDT), is first used to compress the PMU data and generate multiple compression intervals. Then dynamic programming is utilized to solve the optimization problem, which is recursively constituted by a score function. Based on predefined PMU event rules, dynamic programming merges adjacent compression intervals with the same slope direction. Finally, all the PMU event features are characterized. A conventional wavelet-based event detection method is compared with the developed dynamic programming based SDT (DPSDT) method. Numerical simulations on the real-time and synthetic PMU data show that the DPSDT method can accurately detect the start-time of an event and the event placement with relatively high precision. Furthermore, the PMU event features, including the magnitude and duration of strokes, are characterized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clarifying Terminology in Microbial Ecology: A Call for Precision in Scientific Communication

The rapid evolution of microbiology as a field of research has led to the introduction of new terminology and the adaptation of existing terms. However, inconsistencies in the use of these terms, including variations across different scientific disciplines, can lead to confusion and miscommunication within the scientific community. This article discusses the importance of precise terminology in microbiome research, highlighting examples where terms have been misused or redefined without clear justification. We also present a list of frequently used terms in microbial ecology along with their specific definitions. We argue that the misuse of terminology can hinder scientific progress by creating ambiguity and misunderstanding. To address this, we propose a set of guidelines for the consistent use of key terms and provide clear definitions for some of the most commonly misused or newly introduced terms in the field. The definitions provided herein will also function as a guide for young researchers new to the field of microbial ecology. Accurate and consistent use of terminology is crucial for effective communication and collaboration in microbiology research. By adhering to standardised definitions, researchers can ensure that their work is clearly communicated and contributes meaningfully to the progress of science.

definitions↗

High-Precision Zinc Isotopic Measurement of Certified Reference Materials Relevant to the Environmental, Earth, Planetary and Biomedical Sciences

The zinc (Zn) stable isotope system has emerged as a powerful tool for investigating natural and anthropogenic processes of interest to disciplines extending from the Earth and planetary sciences to biomedical research. In nature, Zn isotopes typically fractionate ( 66 Zn/ 64 Zn) within the range of –1 and +1 permil (‰), and however, analytical limitations restrict the application of the Zn isotope system. Specifically, there is a lack of well-characterised matrix-matched reference materials covering most Zn isotope applications that are essential for validating laboratory performance, particularly given the contamination prone nature of Zn. Furthermore, the increasing demand for analysis of size-limited materials and sample types displaying small, sub-permil level Zn isotope variations requires improvements in measurement procedures. To address these limitations, the δ 66 Zn values of two pure Zn solutions and eighteen reference materials including the previously uncharacterised RGM-2, BCR-279, DOLT-4, DOLT-5, NASS-7, SBC-1, SGR-1b, MESS-3 and HISS-1, and the understudied QLO-1, SDC-1, BCR-414, NASS-6 and COQ-1 materials are reported. Furthermore, a 70 Zn- 67 Zn double-spike design has been implemented that routinely achieves intermediate measurement precision better than ± 0.02‰. This represents at least a two-fold improvement when compared with other double-spike designs, providing a robust platform of δ 66 Zn values required for quality control procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗