At least 1,261 records · Page 70

Methods for Microgrid Protection (Literature Review)

This work reviews existing conventional and non-conventional protection schemes for grid- and islanded-connected mode operations in North American microgrid projects. The protection schemes applied for the microgrid projects had different types of distributed energy resources (DERs), and integrated the hydropower/diesel generators, gas/steam/wind turbines and photovoltaic (PV) systems with energy storages. In this work, conventional protection schemes were those defined within the IEEE Standard C37.2-2008, while non-conventional schemes were those not defined within this Standard. The pros and cons of conventional and non-conventional protection schemes applied in microgrid projects were discussed in detail. The overvoltage, undervoltage and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because the small fault currents contributed by the low-inertia DERs and power-electronic sources. The directional overcurrent elements allowed to distinguish between external (grid) and internal (microgrid) faults. The adaptive protection was the most popular non-conventional protection scheme applied in microgrid projects. The adaptive protection detected if the microgrid was set in grid- or islanding-connected modes and selected the relay settings for the actual microgrid conditions to avoid relays’ misoperations. In conclusion, each microgrid project can confront different types of DERs and operation modes that require individual studies to solve their protection and control challenges, to obtain the best technical and economical solution. The protection scheme results and discussions for North American microgrid projects collected in this report provides an important information to guide protection and control engineers, designers and researchers in defining the protection methods for microgrids based on the types of DERs and grid- or islanded-connected operational modes

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗

Evaluating Grid Strength under Uncertain Renewable Generation

The increasing displacement of synchronous generators with renewable resources such as wind and solar via power electronic interfaces causes a reduction in short-circuit strength and weak grid issues. The variation and uncertainty of renewable energy increase challenges for identifying weak grid conditions. This paper proposes an efficient method to analyze the impact of uncertain renewable energy on grid strength. The proposed method uses the probabilistic collocation method (PCM) to approximate the results of grid strength assessment under uncertain renewable generation, in order to reduce computational burden without compromising result accuracy when compared with traditional Monte Carlo simulation (MCS). To improve the accuracy of the approximation results, the proposed method integrates the K-means clustering technique with PCM to select the approximation samples of input variables. The efficacy of the proposed method is demonstrated by comparison with MCS on the modified IEEE 9-bus system and modified IEEE 39-bus system with multiple renewable generators.

grid strength↗

Uncovering Droop Control Laws Embedded Within the Nonlinear Dynamics of Van der Pol Oscillators

This paper examines the dynamics of power-electronic inverters in islanded microgrids that are controlled to emulate the dynamics of Van der Pol oscillators. The general strategy of controlling inverters to emulate the behavior of nonlinear oscillators presents a compelling time-domain alternative to ubiquitous droop control methods which presume the existence of a quasistationary sinusoidal steady state and operate on phasor quantities. We present two main results in this paper. First, by leveraging the method of periodic averaging, we demonstrate that droop laws are intrinsically embedded within a slower time scale in the nonlinear dynamics of Van der Pol oscillators. Second, we establish the global convergence of amplitude and phase dynamics in a resistive network interconnecting inverters controlled as Van der Pol oscillators. Furthermore, under a set of nonrestrictive decoupling approximations, we derive sufficient conditions for local exponential stability of desirable equilibria of the linearized amplitude and phase dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Singular Perturbation-Based Large-Signal Order Reduction of Microgrids for Stability and Accuracy Synthesis With Control

The increasing penetration of distributed energy resources (DERs) highlights the growing importance of microgrids (MGs) in enhancing power system reliability. Employing electromagnetic transient (EMT) analysis in MGs becomes crucial for controlling the rapid transients. However, this requires an accurate but high-order model of power electronics and their underlying control loops, complexifying the stability analysis from the viewpoint of a higher control level. To overcome these challenges, this paper proposes a large-signal order reduction (LSOR) method for MGs with considerations of external control inputs and the detailed dynamics of underlying control levels based on singular perturbation theory (SPT). Specially, we innovatively proposed and strictly proved a general stability and accuracy assessment theorem that allows us to analyze the dynamic stability of a full-order nonlinear system by only leveraging our derived reduced-order model (ROM) and boundary layer model (BLM). Furthermore, this theorem furnishes a set of conditions that determine the accuracy of the developed ROM. Lastly, by embedding such a theorem into the SPT, we propose a novel LSOR approach with guaranteed accuracy and stability analysis equivalence. Case studies are conducted on MG systems to show the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Structures for Voltage Controllers in Inverters: Preprint

Output voltage regulation is a primary performance objective in power electronics systems which are not supported by a stiff voltage source. In this paper, we pose an optimal voltage control problem for ac inverter systems and study the structure of the resulting feedback laws. Here, it is demonstrated that the solution to the optimal voltage regulation control problem exhibits an inner current-controller structure even though there are no explicit objectives on tracking current which are targeted. Furthermore, the outer-loop voltage control and inner-loop current control structure is insensitive to the weighting transfer functions used in the optimal control problem. Although the inner-outer structure has been used in prior works, the optimal nature of such a structure was not known. In deriving the optimal controller, we also present a systematic design framework which is cognizant of the physical properties of inverters. Case studies are used to study the optimal controller and its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance-Based Prediction of Distortions Generated by Resonance in Grid-Connected Converters

Small-signal impedance-based analysis can effectively predict the frequency and damping of resonance modes in power electronic systems. However, it cannot predict the magnitude of resonance or explain resonance-generated distortions in the absence of an external disturbance at the resonance frequency. This paper presents an impedance-based theory for the prediction of the magnitude of resonance or resonance-generated distortions in grid-connected converters. It is discovered that the impedance response of a converter starts changing with the magnitude of resonance at its terminals. The changing converter impedance response may stabilize an unstable growing resonance mode beyond a certain magnitude, at which point the converter enters a limit cycle mode of sustained oscillations. The proposed theory uses large-signal impedance for the prediction of resonance-generated distortions; the large-signal impedance of an electrical equipment represents its impedance response for different magnitudes of perturbation injected at its terminals. Large-signal impedance-based prediction of resonance-generated distortions is demonstrated for a three-phase grid-connected voltage-source converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

All-SiC Inductively Coupled Charger with Integrated Plug-in and Boost Functionalities for PEV Applications

So far, vehicular power electronics integration is limited to the integration of on-board battery chargers (OBC) into the traction drive system and sometimes to the accessory dc/dc converters in plug-in electric vehicles (PEV). These integration approaches do not provide isolation from the grid although it is an important feature that is required for user interface systems that have grid connections. This is therefore a major limitation that needs to be addressed along with the integrated functionality. Furthermore, there is no previous study that proposes the integration of wireless charger with the other on-board components. This study features a unique way of combining the wired and wireless charging functionalities with vehicle side boost converter integration and maintaining the isolation to provide the best solution to the plug-in electric vehicle users. The new topology is additionally compared with commercially available OBC systems from manufacturers.

boost converter↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

A Rotational Control in Medium-Voltage Modular Solid-State Transformer-Based Converter System

This article presents a novel control strategy to significantly reduce the high-frequency transformer loss in a modular solid-state transformer (SST) based converter system. The modular SST design is based on an ac-dc power-electronic building block comprised of an H-bridge at the ac input and a bidirectional soft-switching isolated dc-dc converter with a medium-voltage insulated high-frequency transformer. The ac terminals of input H-bridges are connected in series and directly coupled to the medium-voltage ac line, while the output dc terminals are all connected in parallel at a low voltage. The key innovation described in this paper, without sacrificing the output performance, is the control scheme that reduces core and winding losses associated with the dc-dc resonant stage by turning off the selected dc-dc converters in synchronism with the line voltage. The prototype for the test described in this paper is based on a modular SST where each module is rated at 50 kVA, with a 200 kHz transformer using 1.7 kV silicon carbide discrete mosfets, but the described control concepts are more broadly applicable to similar topologies.

42 ENGINEERING↗

Model-free control for frequency response support in microgrids utilizing wind turbines

Islanded microgrids integrated with renewable energy resources bring additional challenges to the primary frequency control due to their power-electronic interfaced generations. Developing an efficient control strategy for inertia emulation and frequency response support of microgrids is becoming an important issue. Wind turbine dynamics, however, will degrade the emulated inertial and primary responses with most traditional control strategies. On the other hand, compensation methods often require the knowledge of system models at the design stage and state estimation for feedback once deployed online. To overcome these challenges, this paper explores a model-free control (MFC) strategy to emulate the desired inertia and support the frequency response of a diesel-wind microgrid system. Additionally, the proposed MFC strategy utilizes a model reference concept to obtain guaranteed inertial response and improve the frequency response of microgrids. This work considers different control strategies with different operating points. The proposed controller is implemented and verified using the modified 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results demonstrate the improved frequency response by precisely emulating the desired inertia using the MFC strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced TidGen Power System - LCOE Calculations and System Overview

The TidGen Power System generates emission-free electricity from tidal currents and connects directly into existing grids using smart grid technology. The power system consists of three major subsystems: shore-side power electronics, mooring system, and turbine generator unit (TGU) device. This submission includes the Advanced TidGen cost and cost of energy metrics after critical design review for BP1, and a complete LCOE content model and LCOE reporting according to DOE guidance for the baseline system and the system with advanced technology integrated. A revised LCOE content model is also included, with more relevant market array assumptions. Additionally, this submission includes a complete system overview and component overview content models. The LCOE Content Model provides data submitters with an easy and consistent means of uploading data that can be used to calculate the levelized cost of energy for MHK devices. Data represents the design completed for the Critical Design Review conducted at ORPC in December, 2017. All values are for a single device. Note that with substantial fixed costs, larger arrays will greatly reduce LCOE. For an array in Admiralty Inlet producing 136,000 MWh, 270 devices with an array CAPEX of $540,260,052 and an array OPEX of $39,959,207 would result in an LCOE of $722/MWh.

16 TIDAL AND WAVE POWER↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗