Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

A re-entrant groove hydrogen heat pipe

This paper extends the development of reentrant groove technology to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. Acceptable production-type runs of extruded lengths (over 300 m) could only be achieved at the expense of a wider nominal groove opening than specified (0.33 mm vs. 0.20 mm). However, dimensional variations of other critical dimensions were within 0.05 mm, which exceeded expectations. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3-mm-diam vapor core. Each axial groove is 0.775-mm-diam with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Details of the instrumentation and helium-cooled test installation are also presented.

Alario, J.↗

Performance investigations of liquid-metal heat pipes for space and terrestrial applications

The high heat transfer capacity of liquid-metal heat pipes is demonstrated in performance tests with mercury, potassium, sodium, and lithium working fluids and wick structures which serve to minimize liquid pressure losses and vapor/liquid interactions. Appropriate wicks for horizontal and vertical operation are described. It is shown that heat-transfer with these wicks is limited by vapor flow effects. Examples are given of particular effects associated with a long adiabatic section between evaporator and condenser and with a heat source of uniform temperature as opposed to a source of uniform power.

Kemme, J. E.↗

A siphon method of determining resistivities of thin heat-pipe wicks

A simple siphon method is described for determining the resistivities of thin heat pipe wicks as a function of the pressure difference between the liquid in the wick and the vapor above it. The method was applied to wicks of one layer and two layers of 100 mesh (40 per centimeter) stainless steel screens diffusion bonded to stainless steel substrates. Some possible improvements in the method are suggested.

Katzoff, S.↗

Heat pipe radiators for space

An optimized flight-weight prototype fluid-header panel (heatpipe radiator system) was tested in a vacuum environment over a wide range of coolant inlet temperatures, coolant flow rates, and environmental absorbed heat fluxes. The maximum performance of the system was determined. Results are compared with earlier data obtained on a smaller fluid-header feasibility panel, and computer predictions. Freeze-thaw tests are described and the change in thaw recovery time due to the addition of a low-freezing point feeder heat pipe is evaluated. Experimental panel fin-temperature distributions are compared with calculated results.

Sellers, J. P.↗

Subcarrier phase recovery performance in bent-pipe mode of Shuttle data transmission

The subcarrier phase recovery is analyzed for the bent-pipe mode of Space Shuttle detached-payload data transmission on the Tracking and Data Relay Satellite System (TDRSS) Ku-band return link. The high-power component of the subcarrier modulation is unrestored payload data, either at baseband or modulating another subcarrier. At the receiver a Costas loop recovers the subcarrier phase. To analyze its performance in the baseband case, we obtain the loop S-curve, the power spectral density of the equivalent noise process, and the loop phase error variance.

Mckenzie, T. M.↗

Heat pipe cooling of power processing magnetics

A heat pipe cooled transformer and input filter were developed for the 2.4 kW beam supply of a 30 cm ion thruster system. This development yielded a mass reduction of 40% (1.76 kg) and lower mean winding temperature (20 C lower). While these improvements are significant, preliminary designs predict even greater benefits to be realized at higher power. The design details are presented along with the results of thermal vacuum operation and the component performance in a 3 kW breadboard power processor.

Hansen, I. G.↗

Long term tests of the HEPP liquid trap diode heat pipe prototype

The test results which were obtained with the HEPP liquid trap diode heat pipe prototype after it had been in storage for almost 27 months are presented. Transport data were obtained over the range of 150 to 220 K and reverse mode shutdown was measured with nominal operation at 180 K.

Source record↗

NASTRAN analysis of heat-transfer fluid fill pipe failure

An example that shows the difficulties of failure analyses and the advantage of the finite element method (NASTRAN) in assisting in determining the true cause of a failure is presented. In this example, cracks were developing along a pipe weld. After discarding several possible causes for the failures, it was finally determined that the problem was due to stress corrosion cracking associated with a rather unusual and novel environmental condition.

Winter, J. R.↗

Comparison of finite element analysis of a piping tee using NASTRAN and CORTES/SA

A comparison of finite element analyses of a piping tee was made using NASTRAN and CORTES/SA, a modified version of SAP3 having a special purpose input processor for generating geometries for a wide variety of tee joints. Four finite element models were subjected in force, moment, and pressure loadings. Flexibility factors and principal stresses were computed for each model and compared with results obtained experimentally by Combustion Engineering, Inc. Results from the NASTRAN analyses were in good agreement with experimental results for all loadings except internal pressure. The CORTES/SA analyses gave good results for the internal pressure loading, but poorer results for out of plane bending moments or forces resulting in out of plane bending. Two of the basic load cases in CORTES/SA were found to contain errors that could not be easily corrected. COST COMPARison of NASTRAN and CORTES/SA showed NASTRAN to be less expensive to two than CORTES/SA for identical meshes.

Quezon, A. J.↗

Acoustic loading in straight pipes

Based on linear one-dimensional acoustics, a geometrically perfect elastic waveguide would respond to an oscillatory internal pressure only in the presence of path deflectors (elbows and branches). In practice, a significant elasto-acoustic interaction results even in straight conduits as a result of manufacturing tolerances. A theoretical model of the linear acoustic loading in straight pipes is developed that considers the acoustic wave distortion due to perimeter, axial, and wall thickness nonuniformities.

El-Raheb, M.↗

On the calculation of turbulent heat transport downstream from an abrupt pipe expansion

A numerical study of flow and heat transfer in the separated flow region produced by an abrupt pipe explosion is reported, with emphasis on the region in the immediate vicinity of the wall where turbulent transport gives way to molecular conduction and diffusion. The analysis is based on a modified TEACH-2E program with the standard k-epsilon model of turbulence. Predictions of the experimental data of Zemanick and Dougall (1970) for a diameter ratio of 0.54 show generally encouraging agreement with experiment. At a diameter ratio of 0.43 different trends are discernable between measurement and calculation, though this appears to be due to effects unconnected with the wall region studied here.

Chieng, C. C.↗

On the calculation of turbulent heat transport downstream from an abrupt pipe expansion

A numerical study is reported of flow and heat transfer in the separated flow region created by an abrupt pipe expansion. Computations employed an adaptation of the TEACH-2E computer program with the standard model of turbulence. Emphasis is given to the simulation, from both a physical and numerical viewpoint, of the region in the immediate vicinity of the wall where turbulent transport gives way to molecular conduction and diffusion. Wall resistance laws or wall functions used to bridge this near-wall region are based on the idea that, beyond the viscous sublayer, the turbulent length scale is universal, increasing linearly with distance from the wall. Predictions of expermental data for a diameter ratio of 0.54 show generally encouraging agreement with experiment. At a diameter of 0.43 different trends are discernible between measurement and calculation though this appears to be due to effects unconnected with the wall region studied.

Chieng, C. C.↗

Heat pipe solar receiver with thermal energy storage

An HPSR Stirling engine generator system featuring latent heat thermal energy storge, excellent thermal stability and self regulating, effective thermal transport at low system delta T is described. The system was supported by component technology testing of heat pipes and of thermal storage and energy transport models which define the expected performance of the system. Preliminary and detailed design efforts were completed and manufacturing of HPSR components has begun.

Zimmerman, W. F.↗

The monogroove high performance heat pipe

The development of the monogroove heat pipe, a fundamentally new high-performance device suitable for multi-kilowatt space radiator heat-rejection systems, is reported. The design separates heat transport and transfer functions, so that each can be separately optimized to yield heat transport capacities on the order of 25 kW/m. Test versions of the device have proven the concept of heat transport capacity control by pore dimensions and the permeability of the circumferential wall wick structure, which together render it insensitive to tilt. All cases tested were for localized, top-side heat input and cooling and produced results close to theoretical predictions.

Alario, J.↗

The heat pipe thermal canister

The thermal canister represents a new approach to instrument thermal control for Shuttle experiments which require tight temperature control. The canister substitutes a known, benign thermal environment for the variable and uncertain environment of space, the space environment being neutralized by a system of feedback controlled variable conductance heat pipes. A proto-flight unit has been fabricated and this paper describes the acceptance thermal vacuum test results of the thermal canister experiment which will fly on an early Space Shuttle flight.

Harwell, W.↗

Reentrant-Groove Hydrogen Heat Pipe

Aluminum heat pipe extruded with reentrant axial grooves, which give better overall performance than conventional rectangular grooves. Reentrant grooves increase wicking height of cryogenic fluids and also lower amount of fluid charge required.

Alario, J.↗

Portable Pipe Wrapper

New tool applies fragile layered insulation to cryogenic tubing. Used routinely to apply two layers of fiberglass and one of aluminum foil on pipe used as inner line in vacuum jacketed cryogenic plumbing. Wrapper is easy to use and made from inexpensive, readily available parts. Wheeled to whatever location is convenient for wrapping.

Dennis, G. B.↗