Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PH VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Investigating the Effect of Sorbed Humic Acid on the Mobility of Uranium - 19461

The Savannah River Site (SRS) was one of the major nuclear facilities for the U.S Department of Energy. During the Cold War, these facilities produced large amounts of radioactive and hazardous waste. On site, the F-Area consisted of three unlined seepage basins that collected approximately 6.8 billion liters of low-level waste that contained nitric acid, radionuclides, and dissolved metals due to plutonium separation operations. Sufficient quantities of uranium isotopes, I-129, Tc-99, and tritium migrated into the groundwater, creating an acidic plume with a pH between 3 and 5.5. Although the basins functioned as designed, the acidic nature of the waste created a source of contamination for the groundwater and soil below the basins. With radionuclides above their maximum contaminant level (MCL) remediation efforts took place. Humic acid as a remediation technology has shown potential for controlling radionuclide mobility. Humic acid is a fraction of humic substance that are ubiquitous in the environment. Humic substances (HS) are complex heterogeneous mixtures of polydispersed materials formed by biochemical and chemical reactions during the decay and transformation of plant and microbial remains. Humic substances account for 50-80% of the organic carbon in the soil or sediment and are known for their excellent binding capacity for metals. Humic acid can be extracted with a potassium hydroxide base solution and then drying it. The high pH solubilizes the humic acid molecules and generates a dark-brown highly-concentrated solution, rich in humic acid, which can be diluted for use. Humic acid's strong sorption capacity and its ability to develop a bond with uranium at slightly acid pH constitute it as remediation technology to reduce uranium (VI) mobility. Column experiments were performed to identify the sorption and desorption of HS in flow-through porous media representative of the acidic aquifer at the F-Area Seepage Basins. Two commercially available HA were selected for comparison, Huma-K and KW15 modified humics (modified humic acid, mod-HA). By conducting a nonreactive rhenium tracer test, on columns filled with soil obtained from SRS's FAW-1 at a depth interval of 18 m -21 m, column parameters such as pore volume (PV), variance, dispersion and peclet number were determined. Columns were then used to estimate the influence of HA on uranium mobility. Data obtained from this study shows that using HA as an amendment for uranium remediation improves uranium removal significantly. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Chemistry Envelope for the Determination of Pitting Corrosion Susceptibility - 19554

Liquid radioactive wastes at the Hanford and Savannah River sites are stored in large underground carbon steel tanks. The high-level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life (i.e., greater than 60 years). Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. Chemistry controls are based on in-situ coupon tests, waste tank experience, and laboratory testing. These requirements comprise the technical standards for corrosion control. The standards are utilized then as guidelines for operational procedures. The present waste chemistry controls for the Hanford DSTs were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the DOE Savannah River Site (SRS). Portions of the SRS chemistry limits, which were developed at the Savannah River National Laboratory (SRNL) were coupled with corrosion testing results from Pacific Northwest National Laboratories (PNNL) and adopted for corrosion control of the double-shell tank (DST) waste at the Hanford Site. Since that time, the temperatures of the waste in the DSTs have decreased to less than 50 deg. C in most cases as the radioactive material has decayed. As a consequence, new chemistry controls were formulated for SCC in 2010. This testing however, did not address that potential for pitting in the supernatant and at the liquid-air interface. Indeed, initial tests indicated that the inhibitor requirements for SCC would be insufficient for the prevention of pitting. In addition to lower waste temperatures, future retrieval and process changes may impact the DST waste chemistry. Initial projections suggest that the waste chemistry of the DSTs may shift to a broader range of pH and higher aggressive anion concentrations (e.g., chloride, sulfate, etc.) than the wastes that are presently stored. Additionally, processes within the vitrification facility may result in streams that are returned to the tank farm for evaporation. These streams may also contain high concentrations of aggressive species. SRNL investigated the propensity for pitting of the carbon steel waste tanks at current and projected DST waste chemistries. A statistically designed series of tests provided a pitting factor that relates the ratio of the inhibitor species to the aggressive species and the probability of observing pitting. An acceptable pitting factor was determined and was utilized for the development of a new chemistry envelope. The new chemistry envelope was compared to the envelope that was established for SCC and was determined to be bounding. Validation of the new chemistry envelope was performed via model simulations and comparison with historical experimental results and approaches to establishing chemistry envelopes. The new chemistry envelope will eventually be part of an overall assessment of the condition of the tanks and any changes made to the overall structural integrity program for the Hanford DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding and Controlling Cesium Loading on Crystalline Silicotitanate - 19601

Savannah River Remediation (SRR) contracted with Westinghouse Electric Corporation (WEC), Columbia Energy and Environmental Services (CEES), to build and deliver a modular ion exchange process that will be used to remove radioactive cesium from dissolved salt solution contained in Tank 10 at the Savannah River Site (SRS). The resulting decontaminated salt solution will be sent to Tank 11 and then to Tank 50 for final disposition in grout at the Saltstone facility. At the end of processing, the loaded ion exchange (IX) columns are drained, rinsed, and dried. The IX columns are removed from the modular unit and stored at Interim Safe Storage (ISS). This ion exchange process is called the Tank Closure Cesium Removal (TCCR) system. The TCCR system consists of several unit operations and process monitoring capability housed within three modular units. The first modular unit contains the process control computer, the second modular unit contains the main process equipment (two prefilters, four IX columns, and resin trap (post filtration)), and the third modular unit is the ventilation system. The main unit operations of the TCCR system are filtration, ion exchange, and ventilation. The ion exchange media utilized is a form of inorganic Crystalline Silicotitanate (CST), IONSIV{sup TM} R9120-B supplied by UOP Honeywell. CST has a high selectivity for cesium (Cs) and has some affinity for other Group IA alkali metals on the periodic chart (hydrogen, lithium, sodium, potassium, rubidium, and francium). CST has also been shown to have affinity for strontium and actinides. Cesium loading on the CST is dependent on many factors including chemical composition (cations and anions), temperature, and pH of the salt solution. The actual amount of Cs loaded onto an IX column is dependent on the factors above along with the salt solution volume fed to the IX column. Because of CST's high selectivity for Cs, the Cs-137 equilibrium loading can contribute enough decay heat to result in an ion exchange column boiling event under no flow conditions in the IX column. The boiling event under no flow is a safety concern that must be prevented from occurring. To prevent boiling of the column under no flow conditions, the Cs-137 equilibrium loading must be determined and understood. Several methodologies were evaluated for performing the Cs-137 equilibrium loading determination for CST. After review of available research and development (R and D), batch equilibrium contact test data, and Zheng Anthony Miller (ZAM) model predictions for the salt solution chemistry in Tank 10, a methodology for determining the Cs-137 equilibrium loading on CST was selected. The methodology selected involves an in-tank batch equilibrium contact test performed in duplicate that considers additional corrections to account for anticipated operational evolutions. The in-tank batch equilibrium contact test utilizes ∼0.1 grams of CST secured in a slotted sample vial. The slotted sample vial design allows for salt solution to be in contact with the CST. The slotted sample vials containing the CST are submerged in Tank 10 and exposed to the salt solution for ten days. After ten days, the samples are retrieved and sent to the Savannah River National Laboratory (SRNL) for analysis of the Cs-137 equilibrium loading. Additional corrections are then made to the Cs-137 results to account for anticipated operational evolutions. Anticipated operational evolutions include external additions (water/caustic) to Tank 10 that result in a change to its chemical composition, tank temperature effects, departures from the laboratory testing (mixed vs. stagnant tank conditions), and IX column flushes. A description of the methodologies considered, feasibility of methodology deployment, and the down select process (benefits vs. risks) is discussed in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adapting Online Fiber Optic Colorimeter Systems for Process Measurements in H Canyon

A filter-based photometric analyzer, commonly referred to as a colorimeter, is an important instrument for monitoring uranium concentrations for nuclear safety control in SRS's H-Canyon facility. These instruments are effective but technologically out of date, and the facility does not have spare instruments on hand. Newly developed spectrophotometers will replace them and be capable of more accurate and reliable performance than the current colorimeters. However, the installation of the spectrophotometers will take some time. To make sure that the H-Canyon facility can continue processing operations and reduce the risk of a colorimeter going out of service, spare colorimeters previously configured for Pu monitoring in HB-Line will be reconfigured and calibrated for uranium. These spare colorimeters are readily available and their operating procedures are already known to the H-Canyon facility. This reconfiguration is an efficient and cost-effective means to meet a facility need. Both instruments have a linear response and accurately measure U over the range of concentrations expected in the H Canyon process. The instruments are functionally identical and can be used interchangeably. Changes of acidity within the expected process range will not introduce a bias in the measurement. Higher acidity solutions result in a positive bias, but this is conservative with respect to maintaining nuclear safety.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mineral Dissolution upon Alkaline Treatment and Variable Redox Conditions

Over 200.000 kg of uranium released to vadose zone from historic leaks and improper disposal of wastes from plutonium production. U highly mobile due to presence of carbonates and oxidizing conditions with partition coefficients k{sub d} of 0.11-8 mL/g at pH 8. Ammonia (NH{sub 3}) gas injection investigated as an in situ remediation technique that will not introduce additional liquid to the subsurface. Objectives: Understand the impact of remediation with base injection on geochemical process in Hanford site vadose zone. Understand effects of different base treatments on mineral dissolution. Results: - incongruent dissolution based on mineral stoichiometry: if ratio = 1 congruent dissolution occurs, if ratio <1.0 greater leaching of Si and Al and incongruent dissolution occurs. Conclusions: incongruent dissolution occurred for both alkaline treatments and redox conditions across all minerals. By 1440 hr. all normalised Al:Si ratios were <1 representing less [Al]{sub aq} and suggesting formation of secondary Al precipitates as a function of time. [Si]{sub aq} increased and [Al]{sub aq} decreased with increasing contact time with both alkaline treatments. NaOH dissolved slightly more than NH{sub 4}OH especially for [Al]{sub aq} in all investigated minerals. No clear trend for muscovite and montmorillonite for redox conditions but slightly greater Si dissolved under anaerobic conditions for illite. Ammonia gas injection increases the pH and dissolves aluminosilicate minerals in the vadose zone. U is likely to coprecipitate with secondary minerals forming at elevated pH and as the system reequilibrates at natural neutral pH. Further, U solids may be coated with low solubility, secondary precipitates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bioaugmentation of an Engineered Metal Treatment Wetland with Cupriavidus SRS

There are many chemical methods to remediate copper (Cu) from the environment. However, the use of microorganisms has been identified to be cheaper and more efficient in remediating toxic compounds in a method known as bioremediation. A microorganism, Cupriavidus SRS, is a metal resistant, rod shaped, gram negative bacteria that was isolated from a location with heavy metal contamination. As a predator this isolate has the ability to attack gram-negative and gram-positive bacteria. It is highly tolerant to Cu, and the isolates growth initiation is stimulated by Cu. Wang et al. (2015) determined that efflux pump activity is one of the most important mechanisms of heavy metal tolerance and the Cupriavidus genus demonstrates this behavior. In this study, Cupriavidus SRS will be inoculated to sediment and water from an area with high concentrations of Cu and zinc, to determine the ability of the isolate to grow and survive in a high level Cu wetland as well as the bioremoval efficiency. The H-02 wetland in the AL1 outfall area is an engineered wetland that was constructed to utilize natural processes associated with sediments and microbial communities to remove contaminants from waste waters at the Savannah River Site. Specifically, this wetland treats the building processes and runoff form the Tritium Processing Facility in H-area to prevent Cu and Zn from entering the water before the contaminants go in the Savannah River. Distributions of Cu and Zn follow organic matter levels with higher densities along the shoreline showing that metal concentrations correlate with organic matter content. Cupriavidus SRS Growth: Cupriavidus SRS was isolated at the Savannah River Site from an area with heavy metal contamination. Cultures were grown in R2A medium at 25 deg. C and shaken at 80 rpm for liquid cultures for 5 days. Sediment and Water Collection: All samples were collected from the AL1 Outfall area within the Department of Energy's Savannah River Site. Sediment cores, organic layer samples, and water samples were collected from the Inlet and Outlet cells in triplicate. Only water samples were collected from the basin. Cell Pellet: After centrifugation at 10,000 RPM for 10 minutes the supernatant was removed. 1 mL of phosphate buffer saline was added to the tube, vortexed, and recentrifuged. Inoculation of Sediment and Water: All samples were done in triplicate, vortexed after inoculation, and put on the shaker for 72 hours. Day 0 begins when the samples are removed from the shaker. Experimental Set-Up: All samples were done in triplicate. All sediment samples were centrifuged at 7500 RPM for 10 minutes on Day 0 and Day 5. All the sediment and water samples were filtered with a 0.2 μm nylon filters to obtain approximately 10 mL of supernatant on Day 0 and Day 3. pH was taken 24, 48, and 72 hours after the samples had been on the shaker. Plate Count: Plate counts were done on Day 0 and Day 3 to determine Cupriavidus SRS growth following a quantitative counting method from Seely et al. (1972). This project is ongoing and the goal is to determine if Cupriavidus SRS has the ability to uptake excess Cu out of the environment. These could be some possible results for the experiment: - The isolate uptakes too much Cu, dies, and releases Cu back into the environment. - The isolate is able to uptake Cu, continue to live, but chemically changes the environment introducing new problems. - The isolate is able to uptake Cu, continue to live, and does not disrupt the environment with toxic chemical changes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biosorption of Uranium by Bone Meal

The treatment of aqueous solution waste containing organic compounds and radionuclides has always been a great concern since the processes available are usually expensive and unfeasible for the low volume of radioactive liquid waste recovered. In view of a more efficient and low cost treatment, biosorption-based technologies for the removal of this hazardous radionuclides, heavy metals, and organic substances from contaminated matrices have been studied as an alternative process. In this context, bone meal is the material of choice, and contains calcium phosphate in the form of hydroxyapatite. Previous studies with hydroxyapatite showed that this material is efficient in removing heavy metals from polluted soils due to its adsorbing ability. In this context, uranium biosorption capacity by using bone meal was evaluated by different experimental conditions. This study aims at analyzing the capacity of bone meal to remove uranium from aqueous solution through biosorption process, considering that this nuclide is radiotoxic and may cause serious environmental problems and risks to human life if not correctly disposed. The biosorption capacity of U by bone meal was evaluated under different experimental conditions. The results suggested that adsorption with this material can be applied in the treatment of aqueous solutions as a low-cost and highly efficient alternative to remove U. Therefore, we believe that our results are useful for other investigators dealing with similar problems. Further work is required to evaluate this material as a potential adsorbent concerning the treatment of liquid organic radioactive waste containing uranium. Next studies are crucial to ascertain the biosorption efficiency, by analyzing other variables, such as adsorbent dosage, pH and temperature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation of DWPF Chemical Process Cell Using a Reaction Calorimeter

The Defense Waste Processing Facility (DWPF) converts liquid radioactive waste into glass using a Sludge Receipt Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in addition to other processes. The SRAT and SME processes can be simulated on a small-scale using the Mettler-Toledo Reaction Calorimeter (RC1). This equipment is able to automate the execution and monitoring of experiments involving nonradioactive chemical simulants. During the chemical processing of sludge in the SRAT process, foam begins to form and can foam over the reaction vessel. The current antifoam used at DWPF creates a risk of increased flammability and has a limited pH range. Usually, mercury is circulated back into the reaction vessel during the SRAT process, making it difficult to remove. To combat foam over, novel antifoams will be tested during the boil-up process using the RC1. To improve mercury extraction, 3D-printed coalescer columns will be tested within the Mercury Water Wash Tank (MWWT) of the RC1. Testing of Simulant Sludge Batch 6 (SB6) was performed to ensure: the sludge would form a stable foam at boiling during full SRAT/SME runs; the antifoam would reduce the amount of foam within the vessel The sludge and a Precipitate Reactor Feed Tank (PRFT) simulant with monosodium titanate (MST) were mixed separately, combined, and then heated to boiling. As shown below, the antifoam used was able to eliminate the foam within the vessel, as expected. The FormLabs Form2 3D Printer can be used to create roughly 3-inch tall and 1-inch diameter columns from clear and ceramic resins. The columns will utilize chemical and physical forces to draw the mercury out of a condensed offgas stream leaving the RC1 reaction vessel. These columns will be tested during full SRAT/SME runs on the basis of how well they are able to collect elemental mercury. In preparation for full-scale runs, the RC1 equipment was assembled onto a custom table and tested with water runs. The software used to control automation, iControl, has a user-friendly interface that allows the experiment to be altered as needed. An example of the data recorded during an experimental run is represented in Figure 1 below. Water runs were utilized as a way to prove if the RC1 system was functioning in the following areas: Boil-up rates, Chemical additions using pumps, Temperature readings, Balance readings, Probe readings, Offgas system, Agitation. Future Plans: Five novel antifoams will be tested during full SRAT/SME runs. The most effective antifoam will be utilized in DWPF's Chemical Process Cell. The design of the Mercury Extraction Coalescer can be further manipulated to increase the extraction of not only elemental mercury, but other heavy metals in environmental remediation processes as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metal Bioavailability and Ecotoxicity of Bioremediated Oils and Tailings by BioTiger{sup TM}, a Microbial Consortium

Oil Sands and Mature Fine Tailings: Oil sand reserves are a major source of oil for the United States. Oil sands are a mixture of sand, clay, water, and bitumen. The refining process requires large volumes of water and generates hazardous Mature Fine Tailings (MFTs) that are stored in engineered settling ponds. They are of major environmental concern due to their persistence and difficulty to naturally biodegrade. MFT Contaminants of Concern: Naphthenic Acids (NAs), Polycyclic Aromatic Hydrocarbons (PAHs), Benzene, Toluene, Ethylbenzene and Xylene (BTEX), Metals, Residual Bitumen. BioTiger{sup TM} (BT{sup TM}), the SRNL patented 12 component microbial consortia was found to cometabolically degrade some NAs and PAHs. Previous studies performing short term exposure (48 hours and 7 days) to BT{sup TM} have resulted in increased toxicity due to the partial degradation of PAHs forming toxic intermediates. Objective: Evaluate the ecotoxicity of BT{sup TM} remediated MFTs exposed to a 2 week period w/ yeast (Y) extract. This work will determine BT{sup TM}'s remediation of MFTs from Fort McMurray, Alberta. Acute toxicity tests will be performed under section 9 of EPA's Method for Measuring Acute Toxicity using the freshwater organism, Ceriodaphnia dubia. Monitor BT{sup TM} growth through Most Probable Number (MPN) counts, pH, and metal bioavailability will also be evaluated. Preparing tailing solutions for biodegradation: BT{sup TM} components were grown in R2A media and combined. Mother BT{sup TM} was centrifuged at 7000 rpm for 20 minutes and resuspended in Bushnell Haus. 33 g of tailings were added to 1100 mL Bushnell Haus along with yeast extract (11 g) to create a 3% tailing solution. Treatments were performed in triplicate. Preparing solutions for toxicity tests using C. dubia: Supernatant was collected immediately after centrifuging at 7000 rpm for 20 min. Supernatant was filtered via a 0.22 μm sterile system. All treatments except MFT, Y peaked at T=4. This decrease in microbial growth could be associated with toxicity from intermediate byproducts. Treatments containing only MFTs decreased in the initial 11 days before growing significantly. Final solution for MFT, Y treatment had the highest pH. This could potentially be due to increased microbial activity linked with yeast consumption. All treatments except MFT, Y peaked at T=4. This decrease in microbial growth could be associated with toxicity from intermediate byproducts. Treatments containing only MFTs decreased in the initial 11 days before growing significantly. Future Direction: Await results from Acute Toxicity Tests and Metal Bioavailability Quantification of biosurfactant production. Evaluate hydrocarbon degradation byproducts using an analytical chemistry approach. More toxicity experiments with variations in time and conditions.

54 ENVIRONMENTAL SCIENCES↗

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Interfaces to Support Low-Level Waste Disposal System Performance Assessments - 20366

In low-level waste (LLW) disposal sites, interfaces between cementitious materials, used as waste forms and/or engineered barriers, and the surrounding soil or backfill material are often encountered. Reactions across these interfaces may lead to chemical and structural alteration of the cementitious and backfill materials that may ultimately affect long-term performance. For example, the ingress of carbon dioxide from soil gas into a waste tank concrete shell at the Hanford Site or Savannah River Site (SRS) or a low-level waste disposal vault at SRS leads to carbonation of cement hydration products (e.g. portlandite, calcium-silicate hydrate or C-S-H, and ettringite). The result of carbonation is a decrease in pH in the cement paste portion of the tank wall or vault concrete structure that could ultimately lead to de-passivation of the embedded structural steel and, eventually, to cracking. Cracking can lead to increased ingress of water into the structure, corresponding increased release of constituents of concern, and to subsequent increased transport of these constituents to the surrounding environment. The mobility of trace constituents (e.g., radionuclides of concern) in waste forms may increase in response to changes in pH, pore structure, and mineralogical gradients. Depletion of portlandite results in subsequent decalcification of C-S-H that leads to changes in the cement strength and may lead to structural failure. At the boundary between waste forms and concrete vaults, the migration of sulfate ions from the salt waste form (e.g., the saltstone waste form used for LLW disposal at the Savannah River Site in Saltstone Disposal Units, or SDUs) into the barrier or vault concrete has been predicted to result in expansive mineral phase formation (or 'sulfate attack'). Expansive mineral formation could result in cracking and potential loss of structural integrity in the vault concrete. In the performance assessment (PA) for the SRS SDUs, prediction of both the carbonation and sulfate attack fronts are critical to assessing the long-term performance of these LLW disposal vaults. A general purpose geochemical reactive transport model has been developed in LeachXS/ORCHESTRA to evaluate typical interfaces for LLW disposal environments, including SDUs at SRS. The model may be used to predict the long-term performance of interfaces between cementitious materials and saltstone or backfill materials with respect to primary phases by considering mass transport, cement chemistry, geochemical speciation, and multi-ionic diffusion over interfaces between different materials. The present study compares the performance and interactions between vault concrete and saltstone waste form for a representative SDU scenario. The materials were characterized using pH-dependence leaching test (EPA 1313) and semi-dynamic transport tests (EPA 1315) with test results used to parameterize the interface model. The development of a credible inter model provides an important basis for supporting future PAs where carbonation and sulfate attack are important aging and degradation mechanisms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation and Analysis of Dolomite Dissolution in Variable Strength Systems Relevant to the WIPP

The Waste Isolation Pilot Plant (WIPP) was opened in 1999 as a solution to the long-term disposal of the nation's nuclear defense-generated transuranic (TRU) waste. The salt beds were recommended as the ideal location because they are free from flowing fresh water, easily mined, impermeable, and geologically stable. However, for performance assessment modeling, release scenarios must be considered. The most likely release scenario was determined to be human intrusion leading to direct and/or long-term brine release (US DOE 1995, US DOE 1996, Perkins et al., 1999). The focus of this research is the Rustler formation because it is located above the WIPP and is the most transmissive layer (Perkins et al., 1999). Objective: To determine the effect of chelating ligands ( e.g. EDTA) on dissolution of dolomite in high ionic strength systems. Do brines impact dolomite dissolution and how is it affected by EDTA binding with cations? By varying the ionic strengths, different brine conditions can be simulated similar to those in and around the Culebra member and evaluate trends of dissolved Ca and Mg in the aqueous phase from the quantified data. Conclusions: <2% of dolomite dissolved over one week at pH 8.5. Greater dissolution occurred at higher ionic strength and in the presence of NaCl with approximately 0.4 vs. 0.9% of Mg removed from dolomite in 0.1 and 1.0 M Na. Further, 0.3 vs. 0.9% of Mg was removed from dolomite in 1.0 M IS CaCl{sub 2} versus NaCl. EDTA increased dissolution of dolomite at low ionic strength due to its strong complexation affinity for Ca/Mg with slightly greater removal of Ca than Mg. Significant differences were not observed at high ionic strength due to the presence of large concentrations of competing cations (Na, Ca, Mg). Slightly higher concentrations of Ca were removed from dolomite than Mg after one week, suggesting either incongruent dissolution or release through ion exchange of Ca from trace mineral impurities. Further, when EDTA was present, it may have increased Ca removal due to its greater complexation for Ca than Mg. Environmental Implications: High ionic strength brines and low ionic strength solutions with organic ligands increase dissolution of dolomite. Due to the long half-lives of radionuclides in the TRU waste, it may be important to consider the long term impact of dolomite dissolution for potential release scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium Partitioning upon Ammonia Gas Treatment on Phyllosilicate Minerals

In the past, > 200,000 kg of U was released to the Hanford Site vadose zone from disposal and leakage of waste byproducts from plutonium production during World War II and the Cold War (Zachara et al., 2007). U is highly mobile due to the presence of carbonates and oxidizing conditions, with K{sub d} of 0.1 - 8 mL/g at the site (Zachara et al., 2007; Szecsody et al., 2013; Serne et al., 2008). NH{sub 3} (gas) injection is being investigated as a remediation technique as it is an in situ method that will not introduce additional liquid that could drive contaminants deeper into vadose zone towards groundwater. Objectives: To understand the impact of alkaline injection on geochemical processes in the Hanford Site vadose zone, including: 1)Long-term fate of uranium (U); 2)Dissolution and re-precipitation of secondary minerals. Apparent K{sub d}'s increase significantly with NH{sub 3} gas treatment, especially for six-month aging. - K{sub d} decreases after aeration, primarily due to U desorption at lower pH. U removal is still significantly greater than natural conditions (K{sub d} < 8 vs. > 100 mL/g). - Three-day aeration has higher loading than six-month after ammonia gas treatment and aeration. However, significantly greater desorption of U occurs with aeration in the six-month aged sample potentially due to transformation into different, more soluble solid phases with longer term aging. - U removal is primarily due to (1) co-precipitation of U with secondary minerals and (2) adsorption to minerals' surface, although further research is required to identify dominant mechanisms. Future experiments will focus on garnering a better understanding of the solid phase U speciation. Solids will be characterized using SEM-EDS, EMPA, XPS, XAFS, and TEM to better understand the effects of basic treatments on initial minerals and formation of secondary precipitates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disulfonamide Ligands as f-Element Extractants from Alkaline High-Level Waste

Almost 100 million gallons of high level waste (HLW) has been generated from defense reprocessing programs to support nuclear weapons production. HLW is currently stored at the Hanford and Savannah River Sites (SRS) [1]. It contains radioactive components, such as {sup 137}Cs, {sup 99}Tc and {sup 90}Sr, as well as large amounts of non-radioactive species, including solvated cations and insoluble metal hydroxides. HLW has high concentration of soluble hydroxides ([OH{sup -}] = 2 M at SRS [2]), complexing inorganic anions ([NO{sub 3}{sup -}] ∼ 0.65 - 3.7 M at SRS [2]) and a high ionic strength. Even though the majority of actinide component in alkaline HLW is precipitated, studies of An(III) and Ln(III) complexation in highly alkaline solutions in the presence of high nitrate concentrations have showed that soluble nitrate complexes can be formed [3]. The current treatment of HLW at SRS currently consists of two processes: The Actinide Removal Process (ARP) and the Next-Generation Caustic-Side Solvent Extraction process (NG-CSSX). Strontium and actinides are removed by sorption on monosodium titanate through the Actinide Removal Process (ARP) commonly referred to as the alpha-strike step [4]. Then, cesium is selectively extracted from the alkaline media via the Caustic-Side Solvent Extraction (CSSX) process [5]. The CSSX solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix containing i) a solvent modifier (alkylphenoxy alcohol) which increases extractant solubility and prevents third phase formation, and ii) a suppressor (trioctylamine or guanidine) - that mitigates surfactant effects. The CSSX process removes {sup 137}Cs selectively and rapidly, yet the post- CSSX aqueous stream may still contain high amounts of An, thus requiring a second ARP treatment (referred to as 'alpha-finishing') for some tanks. Despite the success of the ARP process in removing Sr and An, it often represents the kinetic bottleneck of integrated processing, as it is slower than solvent extraction. Understanding the complexation of actinides by organic ligands that are compatible with the CSSX process could eventually lead to a combined caustic-side Cs/Sr/actinide extraction process with better economics due to a reduced amount of monosodium titanate and/or a shorter required contact time with titanate during ARP. This would ensure a low-activity waste (LAW) stream with no actinides without additional ARP processing post-CSSX. Disulfonamides were studied for extraction of Sm(III) from alkaline aqueous media of pH 10-14 into dichloromethane. Up to 82% of Sm(III) was extracted from solutions of pH 12.5 -13.5 and up to 84% from solutions of pH 10.5 - 11.5. These results show some resemblance with Am extraction results by calixarene ligands previously reported [10]. Kinetic studies demonstrated that even 5 min is enough to complete stripping, whereas extraction is time-limiting process and requires up to 20 h for efficient removal of Sm(III) from alkaline aqueous media. Determination of composition of complexes in solution after extraction by the equilibrium shift method showed a 1:1 Sm(III):dsa-2 complexation ratio for the extracted species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long Term Assessment of Radiocesium in Deer, Fish, Soil, and Vegetation at the Savannah River Site

Throughout the Savannah River Site's (SRS) operational history, many radionuclides have been released into the environment. However, due to fallout from weapons testing, the amount released from SRS, its persistence in the environment, and the seclusion of the Site, radiocesium (Cs-137) is one of the most critical radionuclides in the SRS environment. The Effective half-life (Te) is the time it takes for a radionuclide in the environment to decrease by 50% of its initial amount. There are three means of radionuclide removal: Physical: Radioactive decay, sedimentation, and washout; Chemical: Changes in pH, oxidation state or adsorption; Biological: Changes in the food web or translocation. Effective half-life (T{sub e}) = log{sub e}2/λ{sub e} Where λ{sub e} is estimated from the slopes of loge-transformed Cs-137 activity concentrations regressed on year. The objective of this work was to calculate the effective half-life of Cs-137 in various biota at SRS and to perform an assessment of the changes in the effective half life over time. Compared to 2013 data, there is a slight increase in the effective half-lives for fish at most sampling locations. This effective half-life increase is an indication that the rate of Cs-137 loss is starting to plateau. The effective half-life of Cs-137 in SRS fish ranges from 4-11 years. The effective half-life of Cs-137 in soil at the Creek plantation is about 15 years. The effective half-life of Cs-137 in grassy vegetation at the Creek Plantation is about 14 years. The effective half-life of deer hunted on the SRS is about 15.5 years. After termination of all reactor activity by 1980, the Cs-137 activity began to drop drastically.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chromate Removal by Long Life IX Resins Without Continuous pH Adjustment - 20083

Long life resins are available for chromate removal from water but have traditionally had the disadvantage of requiring pH adjustment, first to reduce pH before treatment, and then to raise pH following treatment. The requirement for double pH adjustment leads to a significant increase in TDS, added complexity, risks associated with the use of strong acids and bases, and the ongoing costs of purchasing and using these chemicals. The mechanism of removal in long life resins used for chromate removal is ion exchange, followed by reduction of hexavalent chromium to trivalent chromium, followed by immobilization of trivalent chromium within the IX resin polymer. The second step is rate limiting and pH dependent and is the reason why lowering pH before treatment has until now been necessary. However, there is a reasonably simple way to use these long life resins that does not require continuous pH adjustment. By taking a portion of the treatment vessels off line and soaking them in a low pH solution, the rate constant for the reduction step is increased sufficiently to catch up, making the ion exchange step the limiting factor. The long life resin is effectively regenerated by the low pH soaks. Rejuvenated resin beds can then be put back on line and operated at the natural pH of the feedwater. This method of operation is protected by US Patent no. US20150136706A1. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Study on the Transfer of Cs, Sr, Pu and Water in Concrete for the Estimation of Contamination - 20085

As part of the 'Nuclear Energy Science and Technology and Human Resources Development project- through concentrating wisdom-by MEXT' in Japan, the major results from the second year of a project on the analysis of radionuclide contamination mechanisms of concrete and the estimation of contamination distribution at the Fukushima Daiichi nuclear power station active during 2018-2020 are presented. The transfer of Cs, Sr, Pu, and water through concrete was studied experimentally. In a saturated condition, the clay did not affect the transfer and Cs penetrated much faster than Sr. In the dried condition, clay retarded Cs transfer. Carbonation of the concrete retarded the transfer of Cs and Sr. Pu was expected to be precipitated immediately in a high pH condition of concrete. Water suction depends on the temperature. Further, the detailed mechanism was analyzed by {sup 1}H-NMR. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Stability of SiO{sub 2} Fe{sub 3}O{sub 4} Nanoparticles for Uranium Extraction in Acidic Media - 20189

This comprehensive study has shown that the proposed strategy of SiO{sub 2} coating of Fe{sub 3}O{sub 4} nanoparticles (NPs) for the use of uranium (U) extraction in acidic media was successful. The breakdown of Fe{sub 3}O{sub 4} in acidic media has proven to be a challenge when applying to a nuclear waste removal scenario, leading to the dissolution of Fe{sub 3}O{sub 4} and preventing uptake of U ions in the waste. To overcome this a SiO{sub 2} passivating layer was grafted to the Fe{sub 3}O{sub 4} NPs, to which an acid stability test was conducted between pH 3 and pH 4. It has been shown via Transmission Electron Microscopy (TEM) and zeta potential measurements that the uncoated Fe{sub 3}O{sub 4} NPs exhibit rapid coagulation when exposed to acidic conditions, moving from a stable zeta potential of -44 mV to an unstable zeta potential of +6 mV. SiO{sub 2} coated Fe{sub 3}O{sub 4} on the other hand can remain stable for several hours and continue to be stable beyond that. Throughout acid exposure the zeta potential of these NPs remained at ∼ -38 mV, showing great stability. As a functionality is needed on the surface of the NPs for separation and extraction, the phosphate complex used was also tested for its acid stability. It was determined that with a constant zeta potential of ∼ -20 mV, the phosphate functionality was able to remain stable in the acidic conditions simulating the environment of certain nuclear wastes. Overall SiO{sub 2} coated (PO)x-Fe{sub 3}O{sub 4} NPs show great promise for application in separation and removal of U in acid media. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗