Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PASSIVATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Integrating helicoid channels for passive control of fiber alignment in direct-write 3D printing

3D printing of fiber-reinforced composites has been receiving increasing attention as an efficient additive approach enabling lightweight, functional, and high-performance components required for industrial applications. The properties of fiber composites significantly depend on internal microstructures, including fiber orientation, distribution, and degree of alignment. Although multiple strategies have been introduced for controlling the fiber composites microstructures, these strategies are mostly active approaches relying on additional control of mechatronics parts, external forces, or intentionally introduced unstable flows inside narrow nozzles. These methods suffer from higher risk of nozzle clogging and requiring extra parts in 3D printing. Here, we introduce helicoid channels into extrusion system as a passive approach to control the fiber alignment without any additional moving parts in direct-write 3D printing. The helicoid channels automatically guide the composite inks and align fibers before flowing into narrow nozzle space, avoiding clogging and improving printability. The analyses indicate that both helicoid surface to volume ratio and helix angle affect the pre-alignment of fibers, leading to tunable mechanical properties of printed fiber-reinforced composites with increased stiffness and strength up to 77.6% and 47.8%, respectively.

36 MATERIALS SCIENCE↗

Hydrokinetic energy conversion using flow induced oscillations of single-cylinder with large passive turbulence control

Various types of flow-induced oscillations (FIOs) have been implemented in development of marine hydrokinetic (MHK) energy converters. With passive turbulence control (PTC), energy harvesting starts at a flow speed of about 0.5 m/s. However, there is worldwide MHK energy available in even slower currents. In the present study, the effect of damping on FIO and power extraction is investigated for a converter with large turbulence stimulation (PTC) consisting of straight strips with a height of 15% of the cylinder diameter and placed symmetrically on the cylinder surface. The oscillating amplitude decreases, as the damping ratio increases, with unchanged sinusoidal pattern of the displacement time-history. The frequency ratio is also affected by damping especially in the VIV initial branch and transition region between VIV and galloping. An important flow characteristic of the large-PTC cylinder is that a recirculation region is formed behind the PTC, causing appreciable disturbance to the flow past the cylinder. Power can be harvested in the whole FIO range and the harnessed power maximum appears at the largest inflow velocity tested. However, the optimum of harnessing efficiency is located at the beginning of the VIV upper branch. The gap between VIV and galloping is bridged when large PTC is used, eliminating the drop in power and efficiency even at higher damping, which would be a weakness of regular-PTC cylinder for energy harvesting. Finally, the mechanism behind the variation of harnessing efficiency with inflow velocity and damping ratio is revealed, and the optimality criterion for the converter design is discussed.

16 TIDAL AND WAVE POWER↗

Intracellular delivery and passive tumor targeting of a self-assembled nanogel containing carborane clusters for boron neutron capture therapy

Boron neutron capture therapy, based on the release of thermal neutron irradiation from boron, is a targeted radiation therapy for cancer. Targeted and sufficient accumulation of boron in tumor cells to achieve cytotoxic efficacy and reduce off-target effects remains a challenge. Carborane has been investigated for use as a delivery agent in boron neutron capture therapy because of its high boron content and chemical stability; however, it is cytotoxic, making safe delivery difficult. The aim of this study was to investigate the potential of carborane-bearing pullulan nanogels to safely and effectively deliver boron to tumor cells in vitro and in vivo and, consequently, assess their potential as a boron neutron capture therapeutic. Murine fibrosarcoma cells (CMS5a) were used for in vitro investigations of nanogel cytotoxicity, cell uptake. A mouse fibrosarcoma xenograft model was used to investigate the bio-distribution of nanogels after intravenous administration. The nanogels produced no apparent cytotoxicity and underwent cell uptake in CMS5a cells after a 24 h incubation at up to 2000 μg/mL and 400 μg/mL, respectively. The internalized nanogels were localized around the nuclear membrane. The nanogels were administered intravenously to mice bearing fibrosarcoma xenografts. Nanogel tumor localization likely occurred through the enhanced permeation and retention effect. The nanogels successfully reduced the cytotoxicity of carborane, were internalized into tumor cells, acted as a dual-delivery therapeutic and accumulated in tumors in vivo. Consequently, they demonstrate significant potential as a boron neutron capture therapeutic. - Highlights: • A carborane-bearing pullulan nanogel is developed as a boron delivery agent. • The nanogels are cell-friendly and show effective cell uptake for drug delivery. • The nanogels show passive tumor targeting by enhanced permeation and retention.

60 APPLIED LIFE SCIENCES↗

Membrane hydrophobicity determines the activation free energy of passive lipid transport

The collective behavior of lipids with diverse chemical and physical features determines a membrane's thermodynamic properties. Yet, the influence of lipid physicochemical properties on lipid dynamics, in particular interbilayer transport, remains underexplored. Here, we systematically investigate how the activation free energy of passive lipid transport depends on lipid chemistry and membrane phase. Through all-atom molecular dynamics simulations of 11 chemically distinct glycerophospholipids, we determine how lipid acyl chain length, unsaturation, and headgroup influence the free energy barriers for two elementary steps of lipid transport: lipid desorption, which is rate limiting, and lipid insertion into a membrane. Consistent with previous experimental measurements, we find that lipids with longer, saturated acyl chains have increased activation free energies compared to lipids with shorter, unsaturated chains. Lipids with different headgroups exhibit a range of activation free energies; however, no clear trend based solely on chemical structure can be identified, mirroring difficulties in the interpretation of previous experimental results. Compared to liquid-crystalline phase membranes, gel phase membranes exhibit substantially increased free energy barriers. Overall, we find that the activation free energy depends on a lipid's local hydrophobic environment in a membrane and that the free energy barrier for lipid insertion depends on a membrane's interfacial hydrophobicity. Both of these properties can be altered through changes in lipid acyl chain length, lipid headgroup, and membrane phase. Thus, the rate of lipid transport can be tuned through subtle changes in local membrane composition and order, suggesting an unappreciated role for nanoscale membrane domains in regulating cellular lipid dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Optimization-based, property-preserving algorithm for passive tracer transport

Here we present a new optimization-based property-preserving algorithm for passive tracer transport. The algorithm utilizes a semi-Lagrangian approach based on incremental remapping of the mass and the total tracer. However, unlike traditional semi-Lagrangian schemes, which remap the density and the tracer mixing ratio through monotone reconstruction or flux correction, we utilize an optimization-based remapping that enforces conservation and local bounds as optimization constraints. In so doing we separate accuracy considerations from preservation of physical properties to obtain a conservative, second-order accurate transport scheme that also has a notion of optimality. Moreover, we prove that the optimization-based algorithm preserves linear relationships between tracer mixing ratios. We illustrate the properties of the new algorithm using a series of standard tracer transport test problems in a plane and on a sphere.

97 MATHEMATICS AND COMPUTING↗

Study the existing form of copper ( p-type oxide/segregation ) and its release mechanism from the passive film of Ti-7Cu alloy

For this work, the existing form of copper and its release mechanism from the passive film of Ti-7Cu alloy was studied by Quantitative analysis of depth profile and series of electrochemical tests. Results were interpreted within the Point Defect Model-II. Copper does not form any p-type (cuprous or cupric) oxide but preferentially oxidises at the metal/film interface and segregated as Cu interstitials ($Cu^+_i$) and become substituted as $Cu^{x'}_{Ti}$ in the oxygen-deficient TiO 2-x barrier layer having n-type semiconducting character. Eventually, the segregated species of Cu preferentially dissolute through the film as Cu ions into the solution at film/solution interface via the Esaki-tunnelling effect.

Siddiqui, Muhammad Ali↗

Significant life extension of lithium-ion batteries using compact metallic lithium reservoir with passive control

Both traditional graphite-based lithium-ion batteries and next generation silicon-based chemistries suffer significant capacity fade from loss of cyclable lithium due to continued solid-electrolyte interphase growth. A possible engineering solution to maintaining the capacity of cells is incorporating a metallic lithium reservoir and discharging the reservoir into a working electrode to make up for lost cyclable lithium. Here, metallic lithium reservoirs are inserted into both pouch- and cylindrical-format cells. Significant capacity recovery and lifetime extension are demonstrated for traditional graphite and Si/graphite-based cells. In this work, a combination of post-mortem characterization and modeling provide insight into how the lithium distribution as a function of position from reservoir vary with recovery rate. The potential of using passive control to potentially eliminate the need for extra wiring for the third electrode is explored using a simple resistor.

25 ENERGY STORAGE↗

State-of-the-art and review of condensation heat transfer for small modular reactor passive safety: Experimental studies

Here this study focused on state-of-the-art and review of condensation heat transfer for small modular reactors (SMR). Nuclear reactors adopt passive containment cooling systems (PCCS) for accident mitigation, containment integrity, and primarily to maintain the last barrier for radioactive particle release to the environment during and beyond design-basis accidents. However, improving the effectiveness of the PCCS is more critical for the SMR than for commercial reactors to ensure higher safety margins and compactness. In the PCCS of SMR, due to its smaller size containment, the filmwise condensation (FWC) is dominant. Therefore, this study emphasized the FWC. Earlier condensation studies for the PCCS did not make SMR the primary focus, so a critical review for formulating the state-of-the-art was necessary. Part-1 of this study covered the review of physics phenomena, previous experimental studies with a brief overview of associated test facilities and empirical correlations. This study identified a research gap with the condensation test data scaling relations by using the information and findings of the previous PCCS studies and applied them to the SMR system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Respiratory Motion on Passively Scattered Proton Therapy Versus Intensity Modulated Photon Therapy for Stage III Lung Cancer: Are Proton Plans More Sensitive to Breathing Motion?

Purpose: To quantify and compare the effects of respiratory motion on paired passively scattered proton therapy (PSPT) and intensity modulated photon therapy (IMRT) plans; and to establish the relationship between the magnitude of tumor motion and the respiratory-induced dose difference for both modalities. Methods and Materials: In a randomized clinical trial comparing PSPT and IMRT, radiation therapy plans have been designed according to common planning protocols. Four-dimensional (4D) dose was computed for PSPT and IMRT plans for a patient cohort with respiratory motion ranging from 3 to 17 mm. Image registration and dose accumulation were performed using grayscale-based deformable image registration algorithms. The dose–volume histogram (DVH) differences (4D-3D [3D = 3-dimensional]) were compared for PSPT and IMRT. Changes in 4D-3D dose were correlated to the magnitude of tumor respiratory motion. Results: The average 4D-3D dose to 95% of the internal target volume was close to zero, with 19 of 20 patients within 1% of prescribed dose for both modalities. The mean 4D-3D between the 2 modalities was not statistically significant (P<.05) for all dose–volume histogram indices (mean ± SD) except the lung V5 (PSPT: +1.1% ± 0.9%; IMRT: +0.4% ± 1.2%) and maximum cord dose (PSPT: +1.5 ± 2.9 Gy; IMRT: 0.0 ± 0.2 Gy). Changes in 4D-3D dose were correlated to tumor motion for only 2 indices: dose to 95% planning target volume, and heterogeneity index. Conclusions: With our current margin formalisms, target coverage was maintained in the presence of respiratory motion up to 17 mm for both PSPT and IMRT. Only 2 of 11 4D-3D indices (lung V5 and spinal cord maximum) were statistically distinguishable between PSPT and IMRT, contrary to the notion that proton therapy will be more susceptible to respiratory motion. Because of the lack of strong correlations with 4D-3D dose differences in PSPT and IMRT, the extent of tumor motion was not an adequate predictor of potential dosimetric error caused by breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality of Life and Toxicity From Passively Scattered and Spot-Scanning Proton Beam Therapy for Localized Prostate Cancer

Purpose: To report quality of life (QOL)/toxicity in men treated with proton beam therapy for localized prostate cancer and to compare outcomes between passively scattered proton therapy (PSPT) and spot-scanning proton therapy (SSPT). Methods and Materials: Men with localized prostate cancer enrolled on a prospective QOL protocol with a minimum of 2 years' follow-up were reviewed. Comparative groups were defined by technique (PSPT vs SSPT). Patients completed Expanded Prostate Cancer Index Composite questionnaires at baseline and every 3-6 months after proton beam therapy. Clinically meaningful differences in QOL were defined as ≥0.5 × baseline standard deviation. The cumulative incidence of modified Radiation Therapy Oncology Group grade ≥2 gastrointestinal (GI) or genitourinary (GU) toxicity and argon plasma coagulation were determined by the Kaplan-Meier method. Results: A total of 226 men received PSPT, and 65 received SSPT. Both PSPT and SSPT resulted in statistically significant changes in sexual, urinary, and bowel Expanded Prostate Cancer Index Composite summary scores. Only bowel summary, function, and bother resulted in clinically meaningful decrements beyond treatment completion. The decrement in bowel QOL persisted through 24-month follow-up. Cumulative grade ≥2 GU and GI toxicity at 24 months were 13.4% and 9.6%, respectively. There was 1 grade 3 GI toxicity (PSPT group) and no other grade ≥3 GI or GU toxicity. Argon plasma coagulation application was infrequent (PSPT 4.4% vs SSPT 1.5%; P=.21). No statistically significant differences were appreciated between PSPT and SSPT regarding toxicity or QOL. Conclusion: Both PSPT and SSPT confer low rates of grade ≥2 GI or GU toxicity, with preservation of meaningful sexual and urinary QOL at 24 months. A modest, yet clinically meaningful, decrement in bowel QOL was seen throughout follow-up. No toxicity or QOL differences between PSPT and SSPT were identified. Long-term comparative results in a larger patient cohort are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating Intensity Modulated Proton Therapy Relative to Passive Scattering Proton Therapy for Increased Vertebral Column Sparing in Craniospinal Irradiation in Growing Pediatric Patients

Purpose: At present, proton craniospinal irradiation (CSI) for growing children is delivered to the whole vertebral body (WVB) to avoid asymmetric growth. We aimed to demonstrate the feasibility and potential clinical benefit of delivering vertebral body sparing (VBS) versus WVB CSI with passively scattered (PS) and intensity modulated proton therapy (IMPT) in growing children treated for medulloblastoma. Methods and Materials: Five plans were generated for medulloblastoma patients, who had been previously treated with CSI PS proton radiation therapy: (1) single posteroanterior (PA) PS field covering the WVB (PS-PA-WVB); (2) single PA PS field that included only the thecal sac in the target volume (PS-PA-VBS); (3) single PA IMPT field covering the WVB (IMPT-PA-WVB); (4) single PA IMPT field, target volume including thecal sac only (IMPT-PA-VBS); and (5) 2 posterior-oblique (−35°, +35°) IMPT fields, with the target volume including the thecal sac only (IMPT2F-VBS). For all cases, 23.4 Gy (relative biologic effectiveness [RBE]) was prescribed to 95% of the spinal canal. The dose, linear energy transfer, and variable-RBE-weighted dose distributions were calculated for all plans using the tool for particle simulation, version 2, Monte Carlo system. Results: IMPT VBS techniques efficiently spared the anterior vertebral bodies (AVBs), even when accounting for potential higher variable RBE predicted by linear energy transfer distributions. Assuming an RBE of 1.1, the V10 Gy(RBE) decreased from 100% for the WVB techniques to 59.5% to 76.8% for the cervical, 29.9% to 34.6% for the thoracic, and 20.6% to 25.1% for the lumbar AVBs, and the V20 Gy(RBE) decreased from 99.0% to 17.8% to 20.0% for the cervical, 7.2% to 7.6% for the thoracic, and 4.0% to 4.6% for the lumbar AVBs when IMPT VBS techniques were applied. The corresponding percentages for the PS VBS technique were higher. Conclusions: Advanced proton techniques can sufficiently reduce the dose to the vertebral body and allow for vertebral column growth for children with central nervous system tumors requiring CSI. This was true even when considering variable RBE values. A clinical trial is planned for VBS to the thoracic and lumbosacral spine in growing children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phosphate-passivated mordenite for tandem-catalytic conversion of syngas to ethanol or acetic acid

Selective and stable production of C 2 oxygenates from syngas is enabled by a phosphate-passivated mordenite catalyst used in tandem with a commercial Cu/ZnO/AlMgO x catalyst. Unmodified mordenite used in this arrangement is accompanied by substantial hydrocarbon formation and carbon deposition. Therefore, phosphate groups are used to remove or significantly reduce Brønsted acidity in mordenite by capping aluminum sites. Such groups are stable to calcination and catalyst regeneration. Here, trimethylphosphite is used as a phosphate precursor because it is able to enter the 12 membered-ring pores of mordenite where hydrocarbon formation occurs, but not enter the 8 membered-ring sidepockets, where methanol carbonylation occurs selectively. The catalyst was characterized using X-ray fluorescence, X-ray diffraction, and thermal gravimetric analysis. Optionally, a third bed of Cu/ZnO/AlMgO x catalyst is able to hydrodeoxygenate acetic acid to ethanol. The C 2 oxygenate selectivity is over 96% and among the best reported in a single reactor with a syngas feed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT)

With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as well as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients’ average CT. All the plans delivered 50.4 Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V{sub 18} {sub Gy}), stomach (mean and V{sub 20} {sub Gy}), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V{sub 18} {sub Gy}), liver (mean dose), total bowel (V{sub 20} {sub Gy} and mean dose), and small bowel (V{sub 15} {sub Gy} absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose escalation and combining with radiosensitizing chemotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Impact of Gate Width Setting and Gate Utilization Factors on Plutonium Assay in Passive Correlated Neutron Counting

In the field of nuclear safeguards, passive neutron multiplicity counting (PNMC) is a method typically employed in non-destructive assay (NDA) of special nuclear material (SNM) for nonproliferation, verification and accountability purposes. PNMC is generally performed using a well-type thermal neutron counter and relies on the detection of correlated pairs or higher order multiplets of neutrons emitted by an assayed item. To assay SNM, a set of parameters for a given well-counter is required to link the measured multiplicity rates to the assayed item properties. Detection efficiency, die-away time, gate utilization factors (tightly connected to die-away time) as well as optimum gate width setting are among the key parameters. These parameters along with the underlying model assumptions directly affect the accuracy of the SNM assay. In this paper we examine the role of gate utilization factors and the single exponential die-away time assumption and their impact on the measurements for a range of plutonium materials. In addition, we examine the importance of item-optimized coincidence gate width setting as opposed to using a universal gate width value. Finally, the traditional PNMC based on multiplicity shift register electronics is extended to Feynman-type analysis and application of this approach to Pu mass assay is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Confirming the absence of nuclear warheads via passive gamma-ray measurements

Arms-control agreements between the United States and Russia negotiated after the end of the Cold War have imposed limits on the number of deployed strategic nuclear weapons. Verification of these agreements has relied on onsite inspections, sometimes supported by radiation detection techniques to confirm the absence of a nuclear warhead when ambiguities arise. So far, these measurements have sought to detect neutron emissions associated with the presence of plutonium, but they would be inadequate for uranium devices. In an effort to offer instruments that could be used to confirm the absence of both plutonium and uranium weapons, here we propose an inspection system that uses only passive gamma radiation detection techniques. Such a system would be particularly valuable for next-generation arms-control agreements that limit total numbers of weapons and would involve containerized items in storage. We conducted extensive Monte Carlo simulations to support the development of a verification protocol and detection algorithm. Here, we demonstrate the viability of the technique using standard laboratory check sources and MCNP simulations for simplified configurations of special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗