Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARALLEL PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Determining Compression Characteristics of Honeycomb Material - 19674

The objective is to determine compression test characteristics of stainless steel honeycomb material to be able to represent honeycomb structures accurately in analytical models used to simulate hypothetical accident scenarios of shipping packages. Honeycomb is a material used primary in the aerospace industry due to its high strength-to-weight ratio. Because it doesn't have a shelf life and can withstand high heats, it is an excellent candidate for a structural material in package designs. Honeycomb has orthotropic material properties. The honeycomb currently being evaluated is made of metal ribbons spot welded together to form hexagon pattern between metal plates. The hexagon ribbons are brazed to the metal plates. The complexity of the honeycomb significantly lengthens the simulation time, which is further complicated when the brazing, welding, and imperfections of the material is considered. This means to affectively represent the honeycomb in simulation programs, such as Abaqus, the material needs to be approximated as a uniform orthotropic material. This requires material properties in each of the three directions, T, W, and L. The T direction is defined as the 'strong' direction, perpendicular to the honeycomb sheet. The L direction is parallel the ribbon and the W direction is perpendicular to the ribbon. Honeycomb has 3 different compression stages. Stage 1 is the initial compression where the honeycomb maintains its structural integrity and does not permanently deform from loads from normal operations. Stage 2 is when the initial buckling causes irreversible damage to the honeycomb. Stage 2 is the one we are most interested in because it absorbs the most energy from a hypothetical accident scenario. During Stage 2, the honeycomb fails layer-by-layer, indicating that the more layers, the longer material crushing is sustained, and thus the more energy that is absorbed. Stage 3 is final compression, similar to compressing solid metal. During stage 3 the stress increases with a diminishing rate of elongation and the honeycomb is completely failed where the plates between the honeycomb core sandwich the crushed honeycomb ribbon. The stress-strain graph bellow shows compression test of 3 different samples in the T direction. The red lines divide the three stages. The far left is Stage 1, the middle stage 2, and the right stage 3. The data collected is displayed in the table below. The expressions in the table represent the regression formula that represents each stage of the compression on a stress-strain graph. Stage 1 is assumed to intersect with the origin; data for stage 3 for the crush in W and L directions where unable to be gathered due to the nature of failure for those directions. Stage 1 and 2 are linear regressions while stage 3 is a degree 2, to best match the curve. Linear regression is used on stage 2 because ultimately that represents the energy absorbed. With more data, a degree n x 2 regression would be a more appropriate regression for stage 2, where n is the number of layers. The table below is the approximation of each scenario and stage. Each stage starts and ends at the intersection of the next stage. There where two main objectives for these tests: firstly to understand how honeycomb performs under extreme compression, and secondly to be able to numerically represent the honeycomb structure. Both of these where completed to varying degrees. It is important understood how the honeycomb fails. If it is crushed in the T direction it retains its integrity even after being crushed, however when crushed in the L and W crush direction, if it fails, it disintegrates, and loses all integrity. Also, the more layers the more time the material spends in stage 2. Failure is started by buckling, thus if there is any imperfection, the stress will not spike but transition straight into stage 2. The data collected and aggregated can be used for initial simulation of honeycomb used in packages. The initial testing has set the ground work for more data to be collected in order to verify results and to allow more confidence in the simulation results. This is only the initial data collected. The next steps is to continue to collect more data to verify results and to test more variants of honeycomb, with different brazing, layers, and shape.

36 MATERIALS SCIENCE↗

Enabling Ultra-Compact, Lightweight, Efficient, and Reliable 6.6 kW On-Board Bi-Directional Electric Vehicle Charger with Advanced Topology and Control

The research explored new topologies, control methods, mechanical integration, and thermal management methods for electric vehicle (EV) on-board chargers. The team investigated capacitor-based power conversion, leveraging the high energy densities inherent to capacitive energy storage compared to inductive methods. The proposed topologies simultaneously enabled high power density and high efficiency of the design. The proposed architecture was demonstrated in a 6.6 kW bi-directional charger prototype. The research pursued several directions to improve system performance. Innovative topologies were studied for both the main power conversion stage as well as the single-phase twice-line-frequency energy buffer. To ensure robust and efficient operation, new control methods were developed to integrate these two subsystems. To achieve high power density in the full system solution, the mechanical structure of the charger is highly optimized to maximally fill the converter box volume. In parallel with the mechanical design effort, the converter was packaged with high-performance cooling methods which removed heat from key areas of power dissipation in the converter. The thermal management system was optimized to minimize its weight and volume, ultimately motivating the design of a custom additively manufactured cold-plate. The full system achieves a peak power of 7 kW with less than 0.3% total harmonic distortion (THD) and greater than 0.994 power factor in power factor correction (PFC) operation, corresponding to a total box-volume power density of 47.9 kW/L and gravimetric power density of 24.6 W/g. The system achieves a peak efficiency of 98.9%, with 97.9% efficiency at maximum power.

33 ADVANCED PROPULSION SYSTEMS↗

Microwave dichroic plate

A dichroic plate for microwave energy includes an array of interlaced crossed slots or dipole elements. Each of the elements includes first and second crossed arms that are at approximately right angles to each other and aligned with X and Y axes. The elements are arranged so that the centers thereof are aligned parallel to the X and Y axes to form columns and rows, and the interlacing is such that a line between the centers of all adjacent elements has nonzero, differing components relative to the X and Y axes. In one embodiment, the spacing between adjacent arms of different, adjacent elements is the same along the X and Y axes, while in a second embodiment, the spacing between similarly directed arms of adjacent elements differs from the spacing between oppositely directed arms of adjacent elements.

Wise, T. E.↗

Characteristics of a microchannel plate intensifier

A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

Sandie, W. G.↗

Proceedings of the Flat-Plate Solar Array Project Research Forum on the Design of Flat-Plate Photovoltaic Arrays for Central Stations

The Flat Plate Solar Array Project, focuses on advancing technologies relevant to the design and construction of megawatt level central station systems. Photovoltaic modules and arrays for flat plate central station or other large scale electric power production facilities require the establishment of a technical base that resolves design issues and results in practical and cost effective configurations. Design, qualification and maintenance issues related to central station arrays derived from the engineering and operating experiences of early applications and parallel laboratory reserch activities are investigated. Technical issues are examined from the viewpoint of the utility engineer, architect/engineer and laboratory researcher. Topics on optimum source circuit designs, module insulation design for high system voltages, array safety, structural interface design, measurements, and array operation and maintenance are discussed.

Source record↗

Why does near ridge extensional seismicity occur primarily in the Indian Ocean?

It is argued that though thermoelastic stresses provide a low level background in all plates, the data favoring their contributing significantly to the stress field and seismicity in the young oceanic lithosphere may be interpreted in terms of stresses resulting from individual plate geometry and local boundary effects. The dramatic concentration of extensional seismicity in the Central Indian Ocean region is shown to be consistent with finite element results for the intraplate stress incorporating the effects of the Himalayan collision and the various subduction zones. Most of the data for both ridge-parallel extension and depth stratification are provided by earthquakes in this area, and it is suggested that these effects may be due more to the regional stress.

Stein, Seth↗

Acoustical scattering from finite compliant surfaces bounding a duct

Acoustic radiation effects of a finite compliant surface covering a transverse slot in a two-dimensional parallel walled rigid duct are investigated. Radiation from a harmonic source external to the duct is shown to impinge on the slot, reradiating to the half plane and propagating through the duct. Integral equation techniques are employed to study the cases of an open slot, a membrane cover, and a flexible plate cover. The total power radiated to the half plane external to the duct and to the region internal to the duct is determined, taking into account slot-width and fluid-loading variations and the effect of the surface on the power radiated.

Smith, M. E.↗

Grain orientation effects on dynamic strength of FCC multicrystals at low shock pressures: a hydrodynamic instability study

Variability in local dynamic plasticity due to material anisotropy in polycrystalline metals is likely to be important on damage nucleation and growth at low pressures. Hydrodynamic instabilities could be used to study these plasticity effects by correlating measured changes in perturbation amplitudes at free surfaces to local plastic behaviour and grain orientation, but amplitude changes are typically too small to be measured reliably at low pressures using conventional diagnostics. Correlations between strength at low shock pressures and grain orientation were studied in copper (grain size ≈ 800 μm) using the Richtmyer–Meshkov instability with a square-wave surface perturbation (wavelength = 150 μm, amplitude = 5 μm), shocked at 2.7 GPa using symmetric plate impacts. A Plexiglas window was pressed against the peaks of the perturbation, keeping valleys as free surfaces. This produced perturbation amplitude changes much larger than those predicted without the window. Amplitude reductions from 64 to 88% were measured in recovered samples and grains oriented close to $\langle$0 0 1$\rangle$ parallel to the shock had the largest final amplitude, whereas grains with shocks directions close to $\langle$1 0 1$\rangle$ had the lowest. Finite element simulations were performed with elastic-perfectly plastic models to estimate yield strengths leading lead to those final amplitudes. Anisotropic elasticity and these yield strengths were used to calculate the resolved shear stresses at yielding for the two orientations. In conclusion, results are compared with reports on orientation dependence of dynamic yielding in Cu single crystals and the higher values obtained suggest that strength estimations via hydrodynamic instabilities are sensitive to strain hardening and strain rate effects.

36 MATERIALS SCIENCE↗

Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

We have designed and tested a robust 20×20 cm 2 thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al 2 O 3 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm 2 array of 2-dimensional square ‘pads’ with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Low energy, high power hydrogen neutral beam for plasma heating

A high power, relatively low energy neutral beam injector was developed to upgrade of the neutral beam system of the gas dynamic trap device and C2-U experiment. The ion source of the injector produces a proton beam with the particle energy of 15 keV, current of up to 175 A, and pulse duration of a few milliseconds. The plasma emitter of the ion source is produced by superimposing highly ionized plasma jets from an array of four arc-discharge plasma generators. A multipole magnetic field produced with permanent magnets at the periphery of the plasma box is used to increase the efficiency and improve the uniformity of the plasma emitter. Multi-slit grids with 48% transparency are fabricated from bronze plates, which are spherically shaped to provide geometrical beam focusing. The focal length of the Ion Optical System (IOS) is 3.5 m and the initial beam diameter is 34 cm. The IOS geometry and grid potentials were optimized numerically to ensure accurate beam formation. The measured angular divergences of the beam are ±0.01 rad parallel to the slits and ±0.03 rad in the transverse direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniature triaxial metastable ionization detector for gas chromatographic trace analysis of extraterrestrial volatiles

The present investigation is concerned with a miniature metastable ionization detector featuring an unconventional electrode configuration, whose performance characteristics parallel those of traditional design. The ionization detector is to be incorporated in a flight gas chromatograph (GC) for use in the Space Shuttle. The design of the detector is discussed, taking into account studies which verified the sensitivity of the detector. The triaxial design of the detector is compared with a flat-plate style. The obtained results show that the principal goal of developing a miniature, highly sensitive ionization detector for flight applications was achieved. Improved fabrication techniques will utilize glass-to-metal seals and brazing procedures.

Woeller, F. H.↗

NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY16 Status Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year two of this three year project. Highlights from research accomplishments include: • Continuation of a joint collaboration between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. • An updated parallel wire HT MPFD design was developed. • Program support for HT MPFD deployments was given to Accident Tolerant Fuels (ATF) and Advanced Gas-cooled Reactor (AGR) irradiation test programs. • Quality approved materials for HT MPFD construction were procured by irradiation test programs for upcoming deployments. • KSU improved and performed electrical contact and fissile material plating. • KSU delivered fissile HT MPFD parts to INL for final construction of HT MPFD prototype. • A prototype HT MPFD was constructed and analyzed at INL. • The HT MPFD has been modeled in MCNP to optimize the amount of fissile material deposition. • The HT MPFD has been modeled in MCNP to optimize the sensor location in the irradiation test. • The fissile material deposition is undergoing independent verifications. • Detector amplifier electronics have been revised and tested by KSU. • Several project meetings were held at INL and KSU to discuss the roles and responsibilities between INL, KSU, and CEA for development and deployment of the HT MPFDs. As documented in this report, FY16 funding has allowed the project to meet year two planned accomplishments to develop a HT MPFD. In addition, the accomplishments of this project have attracted independent funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for MTR irradiations of the MPFD technology. These are significant opportunities for this NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors project because the irradiation expense of these experiments could not be included in the original project scope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a mesh adaptive scheme based on an element-level error indicator

We investigate the formulation and application of element-level error indicators based on parametrized variational principles. The qualifier 'element-level' means that no information from adjacent elements is used for error estimation. This property is ideally suited to drive adaptive mesh refinement on parallel computers where access to neighboring elements resident on different processors may incur significant computational overhead. Furthermore, such indicators are not affected by physical jumps at junctures or interfaces. An element-level indicator has been derived from the higher-order element energy and applied to r and h mesh adaptation of meshes in plates and shell structures. We report on our initial experiments with a cylindrical shell that intersects with fist plates forming a simplified 'wing-body intersection' benchmark problem.

Keating, Scott↗

4 kW Test of Solid Oxide Electrolysis Stacks with Advanced Electrode-Supported Cells

A new test stand has been developed at the Idaho National Laboratory for multi-kW testing of solid oxide electrolysis stacks. This test stand will initially be operated at the 4 KW scale. The 4 kW tests will include two 60-cell stacks operating in parallel in a single hot zone. The stacks are internally manifolded with an inverted-U flow pattern and an active area of 100 cm2 per cell. Process gases to and from the two stacks are distributed from common inlet/outlet tubing using a custom base manifold unit that also serves as the bottom current collector plate. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. Treated metallic interconnects with integral flow channels separate the cells and electrode gases. Sealing is accomplished with compliant mica-glass seals. A spring-loaded test fixture is used for mechanical stack compression. Due to the power level and the large number of cells in the hot zone, process gas flow rates are high and heat recuperation is required to preheat the cold inlet gases upstream of the furnace. Heat recuperation is achieved by means of two inconel tube-in-tube counter-flow heat exchangers. A current density of 0.3 A/cm2 will be used for these tests, resulting in a hydrogen production rate of 25 NL/min. Inlet steam flow rates will be set to achieve a steam utilization value of 50%. The 4 kW test will be performed for a minimum duration of 1000 hours in order to document the long-term durability of the stacks. Details of the test apparatus and initial results will be provided.

08 HYDROGEN↗

20 years of cosmic muons research performed in IFIN-HH

During the last two decades a modern direction in particle physics research has been developed in IFIN-HH Bucharest, Romania. The history started with the WILLI detector built in IFIN-HH Bucharest in collaboration with KIT Karlsruhe (formerly Forschungszentrum Karlsruhe). The detector was designed for measurements of the low energy muon charge ratio (< 1GeV) based on a delayed coincidence method, measuring the decay time of the muons stopped in the detector: the positive muons decay freely, but the negative muons are captured in the atom thus creating muonic atoms and decay depending on the nature of the host atom. In a first configuration, the WILLI detector was placed in a fixed position for measuring vertical muons. Further WILLI has been transformed in a rotatable device which allows directional measurements of muon charge ratio and muon flux. The results exhibit a pronounced azimuthal asymmetry (East-West effect) due to the different in fluence of the geomagnetic field on the trajectories of positive and negative muons in air. In parallel, flux measurement, taking into account muon events with nergies > 0.4GeV, show a diurnal modulation of the muon flux. The analysis of the muon events for energies < 0.6GeV reveals an aperiodic variation of the muon flux. A new detection system performing coincidence measurements between the WILLI calorimeter and a small array of 12 scintillators plates has been installed in IFIN-HH starting from the autumn of 2010. The aim of the system is to investigate muon charge ratio from individual EAS by using the mini-array as trigger for the WILLI calorimeter. Such experimental studies could provide detailed information on hadronic interaction models and primary cosmic ray composition at energies around 10{sup 15}eV. Simulation studies and preliminary experimental tests, regarding the performances of the mini-array, have been performed using H and Fe primaries, with energies in a range 10{sup 13}eV - 10{sup 15}eV. The results show detailed effects of the direction of EAS incidence relative to the geomagnetic field, depending, in particular, of the primary mass. Based on the results, we can say that WILLI-EAS experiment could be used for testing the hadronic interaction models. Measurements of the high energy muon flux in underground of the salt mine from Slanic Prahova, Romania was performed using a new mobile detector developed in IFIN-HH, Bucharest. Consisting of 2 scintillator plates measuring in coincidence, the detector is installed on a van which facilitates measurements on different positions at surface or in underground. The detector was used to measure muon fluxes in different locations at surface or in underground. The detector was used to measure muon fluxes at different sites of Romania and in the underground of the salt mines from Slanic Prahova, Romania where IFIN-HH has a modern underground laboratory. New methods for the detection of cosmic ray muons are investigated in our institute based on scintillator techniques using optical fiber and MPPC photodyodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-176: Results of Images Acquired with Backscattered MV Radiation Using a Pinhole Collimator

Purpose: To ascertain the feasibility of acquiring real time images of small lung tumors from scattered photons while undergoing radiation treatment.There are several methodologies currently used to track tumor location such as MV-cine acquisition and kV fluoroscopy. However, MVcine offers no information parallel to the beam axis while kV fluoroscopy offers little potential for soft tissue discernability while also increasing the patient dose. This study investigates the feasibility of observing an actual simulated tumor while exploring techniques that may improve image quality. Methods: A prototype imager consisting of a gamma camera pinhole collimator and a computed radiography (CR) plate were used in conjunction with a Varian TrueBeam linac. One study consisted of a 2.5 cm diameter solid water cylinder representing a solid tumor imbedded within a lung equivalent material slab. The cylinder with the lung slab was sandwiched between 1 cm lung equivalent slabs and these were sandwiched between 2 slabs of solid water. The top water slab was 1 cm thick. The other imaging study consisted of three different density plugs, 0.46, 1.09, and 1.82 g/cm3 placed on the accelerator couch. The gantry was orientated 70° relative to the CR plate. The slabs and plugs were irradiated with 2000 MU and 500 MU respectively using the 6FFF mode. Results: The solid water plug was visually discernible in the slab phantom. The ratio of the signal coming from the higher density plugs (placed on the treatment couch) to that between the plugs increased from 1.02 to about 3.0 after subtracting the background image acquired with no plugs present. Conclusion: Preliminary results indicate that a lung tumor could be visualized with scattered radiation during treatment. Improvements in discerning an object can be enhanced by filtering out the head leakage and background scattered radiation not emanating from the imaged object.

60 APPLIED LIFE SCIENCES↗