Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ozone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Standard ozone profiles from balloon and satellite data sets

Standard profiles based on upper level averaged profiles from BUV and lower level averaged profiles from balloon measurements are presented in a parametric representation as a function of time of year and latitude. The representation is a simple 4-parameter function representing the ozone amount (m-atm-cm) in each of 12 atmospheric layers defined following the standard Umkehr convention. The same parameterization is applied to the Nimbus-7 SBUV data and is compared to the BUV/balloon parameterization. The ozone variance unaccounted for by the representation is presented and discussed. The season-latitude representation reduces considerably the ozone variance at all levels and explains much of the correlation between layers. This simple representation and corresponding covariance matrix have been used as a priori information in the ozone vertical profile inversion of the Nimbus-7 SBUV experimental measurements.

Klenk, K. F.↗

Intercomparison of NIMBUS 7 solar backscattered ultraviolet ozone profiles with rocket, balloon, and Umkehr profiles

A global ozone data set covering the two years from November 1978 until October 1980, with an average of 1200 profiles per day, has been produced and archived from the solar backscattered ultraviolet (SBUV) instrument flown on the NIMBUS 7 spacecraft. The SBUV ozone profiles are compared with measurements from chemical and optical sensors launched on balloons and rockets and with ozone profiles obtained from the ground-based Dobson spectrophotometers using the Umkehr method. The biases between the SBUV results and the balloon and Umkehr results are generally less than 10 percent. These biases are functions of layer height and latitude and are believed to be largely due to inconsistencies in the ozone absorption cross sections used for the various measurement systems. The precision of the SBUV measurements is found to be better than 8 percent for pressures between 1 and 64 mbar and better than 15 percent from 64 to 253 mbar.

Bhartia, P. K.↗

Active Optical Sounding of Ozone and Minor Constituents in the Middle Atmosphere: a Review of Ground-based Lidar Measurements

Due to the rapid development of powerful laser sources in the UV wavelength range which includes nd:yag pumped dye lasers and excimer lasers, ground-based lidar systems are now operational for ozone monitoring in the troposphere and the stratosphere. Such systems will play an important role in the determination of long term ozone trends in the photochemical region. The capacities of active lidar systems in terms of high temporal and spatial resolution and measurements continuity, allow the observation of the ozone variations at various time and space scales which are important in present day areas of interest. The already operational character of the lidar systems will constitute the basis for development of a ground-base network for middle atmospheric observations of ozone and other race gases.

Megie, G.↗

Cumulus cloud venting of mixed layer ozone

Observations are presented which substantiate the hypothesis that significant vertical exchange of ozone and aerosols occurs between the mixed layer and the free troposphere during cumulus cloud convective activity. The experiments utilized the airborne Ultra-Violet Differential Absorption Lidar (UV-DIAL) system. This system provides simultaneous range resolved ozone concentration and aerosol backscatter profiles with high spatial resolution. Evening transects were obtained in the downwind area where the air mass had been advected. Space-height analyses for the evening flight show the cloud debris as patterns of ozone typically in excess of the ambient free tropospheric background. This ozone excess was approximately the value of the concentration difference between the mixed layer and free troposphere determined from independent vertical soundings made by another aircraft in the afternoon.

Ching, J. K. S.↗

The influences of the galactic cosmic ray on the atmospheric ozone

The relationship between the yearly variations of cosmic ray intensity and ozone in the atmosphere, and the ozone disturbance initiated by the Forbush decrease of 1965-1976 is analyzed. The data on cosmic ray intensity were selected from the records of the super neutron monitor at Deep River station and the ionization chamber at Beijing station. Ozone data were taken from Resolute (Canada), Bismark (N. Dakota, USA), Kagoshima (Japan), and Kodaikanal (India). The statistical results show that ozone is prominently modulated and disturbed by the 11 year variation and the Forbush decrease in the galactic cosmic ray.

Ye, Z.↗

The temporal behavior of upper stratospheric ozone at low latitudes - Evidence from Nimbus 4 BUV data for short-term responses to solar ultraviolet variability

Ozone mixing ratios at pressure levels near 2 mbar are analyzed for the purpose of estimating the average response of the upper stratospheric ozone to solar UV variability on the time scale of the solar rotation period. The data were obtained from observations made with the Nimbus 4 backscattering UV radiometer in 13 latitude zones between 65 degrees N and 65 degrees S. The anaysis showed that temporal variations are negatively correlated with changes in zonally averaged equivalent temperature measured simultaneously by Nimbus 4 radiometer. A linear regression analysis is performed in order to obtain estimates of the average percent change of ozone at low latitudes, on the considered time scale for given changes in 10.7-cm flux, and in the UV flux model developed by Lean et al. (1982). Reproductions of the ozone profiles are provided.

Hood, L. L.↗

Transport and the seasonal variation of ozone

The transport mechanisms responsible for the seasonal behavior of total ozone are deduced from the comparison of model results to stratospheric data. The seasonal transport is dominated by a combination of the diabatic circulation and transient planetary wave activity acting on a diffusively and photochemically determined background state. The seasonal variation is not correctly modeled as a diffusive process. The buildup of total ozone at high latitudes during winter is dependent upon transient planetary wave activity of sufficient strength to cause the breakdown of the polar vortex. While midwinter warmings are responsible for enhanced ozone transport to high latitudes, the final warming marking the transition from zonal mean westerlies to zonal mean easterlies is the most important event leading to the spring maximum. The final warming is not followed by reacceleration of the mean flow; so that the ozone transport associated with this event is more pronounced than that associated with midwinter warmings.

Rood, R. B.↗

An intercomparison of ozone profile measurements from LIMS, SAGE, and SBUV

Ozone profile measurements by the Limb IR Monitor of Stratosphere (LIMS) and the Solar Backscatter UV (SBUV) aboard the Nimbus satellite, and the Stratospheric Aerosol and Gas Experiment (SAGE) aboard the AEM-2 satellite are intercompared in an effort to assess the quality of satellite ozone retrieval techniques. Good correlation between LIMS and SBUV observations is noted in the ozone layer bounded by pressures of 31.2-15.6 mb; absolute differences are generally less than 10 percent, with similar zonal variations. Above 35 km SAGE values are systematically larger than SBUV or LIMS. The differences generally increase with height and are largest in the tropics. Finally, excellent agreement is noted to exist among the three data sets between 10 and 35 km of altitude with respect to the latitude dependence of the ozone profiles.

Fleig, A. J.↗

Transport of ozone in the middle stratosphere - Evidence for planetary wave breaking

Data from the Nimbus 7 Limb Infrared Monitor of the Stratosphere (LIMS) for the period October 25, 1978-May 28, 1979 are used in a descriptive study of ozone variations in the middle stratosphere. It is shown that the ozone distribution is strongly influenced by irreversible deformation associated with large amplitude planetary-scale waves. This process, which has been described by McIntyre and Palmer as planetary wave breaking, takes place throughout the 3-30 mb layer, and poleward transport of ozone within this layer occurs in narrow tongues drawn on the tropics and subtropics in association with major and minor warming events. These events complement the zonal mean diabatic circulation in producing significant changes in the total column amount of ozone.

Leovy, C. B.↗

Detection of the response of ozone in the middle atmosphere to short-term solar ultraviolet variations

The response of ozone to solar UV variation is determined in the middle atmosphere between the heights of 10 and 0.2 mb. The definitive isolation of the smaller variations associated with short-term solar variability is accomplished only after removal of the larger changes of ozone related to temperature variations. Using this approach the correlation coefficients between detrended ozone (Nimbus 7 LIMS) and short-term 205 nm solar variation (Nimbus 7 SBUV) are found to be much higher (0.9) than achieved in previous studies. The theoretical response time and amplitude of response of ozone in the middle atmosphere to observed short-term solar UV variations is found to be in good agreement with observations, except near 0.2 mb. The corresponding long-term response over the solar cycle is also estimated.

Keating, G. M.↗

The response of ozone to solar proton events during solar cycle 21 - The observations

It is pointed out that during a solar proton event (SPE), large numbers of high-energy protons penetrate the earth's mesosphere and upper stratosphere and perturb the normal chemistry by ionizing molecules and changing the balance of odd nitrogen, oxygen, and hydrogen. Changes in ozone caused by an SPE are produced very rapidly, typically in a matter of hours, and are confined to a limited geographic area, the region above 60 deg geomagnetic latitude. In this paper, an analysis is reported of the response of ozone to the significant SPE's in solar cycle 21 from the Nimbus 7 launch in October 1978 to date, using data from the solar backscattered ultraviolet instrument (SBUV). Ozone data during 15 SPE's were examined. It was found that ozone depletion occurred during SPE's on at least five dates.

Mcpeters, R. D.↗

Intrusion process of stratospheric ozone into the troposphere over Japan

The stratospheric-tropospheric exchanges play an important role in determining the distribution and residence time of ozone, aerosol and other substances in the stratosphere and troposphere. The ozone transport is estimated from the stratosphere into the troposphere by so-called tropopause folding event associated with the polar front jet stream. It is shown that in winter ozone transport occurs mainly in the region to the north of Japan in Asia. The ozone transport rate is estimated. Vertical velocity was estimated by marking the air parcel of an observation aircraft and tracking is on the isentropic surface.

Muramatsu, H.↗

Monthly mean distribution of ozone and temperature

Global monthly mean charts for both hemispheres are given for four mid-season months, and for the pressure levels 30, 10, 1, and 0.1 mbar for temperature and 0.4 mbar for ozone. Charts of total ozone are provided separately. This set of charts shows clearly the very close coupling between the temperature and ozone distributions and demonstrates the influence of the large-scale planetary waves which give rise to very large longitudinal variations. The regular and interannual variability of temperature and ozone are discussed.

Labitzke, K.↗

The detection of long-term changes in stratospheric ozone Scientific requirements and current results from satellite-based measurement systems

The ability to detect subtle trends in upper stratospheric ozone places strict requirements on satellite-based Solar Backscatter Ultraviolet (SBUV) sensors intended for this purpose. Simulation of the long-term change in backscattered radiance indicates trends in the range 1.0-1.6 percent per decade depending on wavelength for an ozone depletion scenario based on chlorofluorocarbon (CFC) chemistry. The maximum percentage change in the measured quantity, as would be sensed by the Nimbus-7 SBUV experiment and future similar instruments, is roughly a factor of two less than the maximum percentage change in ozone, the quantity of geophysical interest. Furthermore, interannual variations, whose magnitude can be estimated from the SBUV data set, could obscure a CFC-related trend in radiance when viewed over a period less than a decade. Even when such atmospheric noise and possible solar cycle variations are neglected, the detection of an ozone trend of the magnitude predicted for CFC-related chemistry requires a set of radiance measurements that are internally consistent to 1 percent or better over a time span of a decade.

Frederick, J. E.↗

Tropospheric ozone - Seasonal behavior, trends, and anthropogenic influence

In the present analysis of tropospheric ozone data, attention is given to spatial and temporal variations. Two modes of seasonal behavior are noted for surface ozone at mid-latitudes: a broad summer maximum within a few hundred km of industrial/urban areas in Europe and the U.S., and a minimum in summer or autumn in sparcely populated regions that are remote from industrial activity. These and limited historical data indicate that summertime concentrations of ozone near the surface in the rural areas of Europe and the U.S. may have increased between 20 and 100 percent since the 1940s. It is suggested that the summer maximum in ozone and other observed trends are due to photochemical production associated with anthropogenic emissions of NO(x), hydrocarbons, and CO from fossil fuel combustion.

Logan, J. A.↗

The observed distribution of atmospheric ozone and its variations

It is pointed out that both the total amount and the vertical distribution of atmospheric ozone are presently measured routinely by various ground-based and satellite-borne instruments and by instruments mounted on different carrier platforms such as balloons, aircraft, and rockets. The techniques of observing atmospheric ozone are discussed, taking into account the determination of total ozone, the Dobson spectrophotometer, the Brewer spectrophotometer, the M-83 Filter Ozonometer, and satellite techniques. In a discussion of studies of vertical distribution, remote systems are considered along with in situ measurements. Attention is given to ground-based methods, satellite platforms, backscatter measurements, limb observations, electrochemical methods, chemiluminescent methods, optical methods, and rocket observations. A number of graphs showing the observed distribution of atmospheric ozone are also presented, and changes in this distribution are evaluated.

London, J.↗

Mesospheric ozone changes associated with 27-day solar ultraviolet flux variations

Solar ultraviolet flux changes associated with the 27-day solar rotational period cause corresponding variations in mesospheric ozone near the maximum of the 11-year sunspot cycle. This statement is based on a correlation and spectral analysis of ozone mixing ratios, deduced from Solar Mesospheric explorer satellite-based measurements of 1.27-micron O2 airglow emission and solar flux observations made from the same spacecraft in 1982. With the Lyman-alpha flux taken as an indicator of solar ultraviolet variability, spectral analysis shows a primary period of 27.1 days with a secondary period of 13.5 days. The 27.1-day period is observed in the ozone mixing ratio data together with other periods, including 13.5 days. Both a classical statistical analysis and a time series treatment show that, for 244 days, there is a correlation between ozone and solar flux near 50 km and between 65 and 70 km. Calculations predict a positive correlation over the entire mesosphere if there is no change in temperature accompanying the solar flux. Lack of correlation is temperature induced.

Aikin, A. C.↗

Measurement of the ozone absorption cross-section at the 253.7 nm mercury line

The absorption cross-section of ozone at 253.7 nm is frequently used as a standard for the entire UV wavelength range. The presently accepted value is 1.147 x 10 to the -17th/sq cm, which is known with an uncertainty of about 2 percent. The cross-section has been recently measured by simultaneously monitoring the ozone pressure, the impurities in the ozone gas, the gas temperature, and the UV beam intensity. The cross-section at room temperature was found to be 1.137 x 10 to the -17th/sq cm having an uncertainty of + or - .7 percent. The improved accuracy will aid a number of ozone experiments including the in situ photometers and Solar Backscatter Ultraviolet instruments.

Mauersberger, K.↗