Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Performance of PMTs for the JSNS 2 experiment

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate γ-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS 2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were purchased around 10 years ago, therefore JSNS 2 did pre-calibration of the PMTs including the purchased PMTs. 123 PMTs demonstrated acceptable performance for the JSNS 2 experiment, and 120 PMTs were installed in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observational techniques for solar flare gamma-rays, hard X-rays, and neutrons

The development of new instrumentation and techniques for solar hard X-ray, gamma ray and neutron observations from spacecraft and/or balloon-borne platforms is examined. The principal accomplishments are: (1) the development of a two segment germanium detector which is near ideal for solar hard X-ray and gamma ray spectroscopy; (2) the development of long duration balloon flight techniques and associated instrumentation; and (3) the development of innovative new position sensitive detectors for hard X-ray and gamma rays.

Lin, Robert P.↗

Resource Letter GrW-1: Gravitational Waves

The phenomenon of gravitational radiation was one of the first predictions of Einstein's general theory of relativity. Progress in understanding this radiation theoretically was slow at first, owing to the difficulty of the nonlinear field equations and the subtleties of their physical effects. The experimental side of this subject also has taken a long time to develop, with efforts at detection severely challenged by the extreme weakness of the waves impinging on the Earth. However, as the 21st century begins, observations of the gravitational waves from astrophysical sources such as black holes, neutron stars, and stellar collapse are expected to open a new window on the universe. Vigorous experimental programs centered on ground-based detectors are being carried out worldwide, and a space-based detector is in the planning stages. On the theoretical side, much effort is being expended to produce robust models of the astrophysical sources and accurate calculations of the waveforms they produce. In this Resource Letter, a set of basic references will be presented first, to provide a general introduction to and overview of the literature in this field. The focus then will shift to highlighting key resources in more specialized areas at the forefront of current research.

White, Nicholas E.↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

Gravitational Waves: A New Observational Window

The era of gravitational wave astronomy is rapidly approaching, with a likely start date around the middle of this decade ' Gravitational waves, emitted by accelerated motions of very massive objects, provide detailed information about strong-field gravity and its sources, including black holes and neutron stars, that electromagnetic probes cannot access. In this talk I will discuss the anticipated sources and the status of the extremely sensitive detectors (both ground and space based) that will make gravitational wave detections possible. As ground based detectors are now taking data, I will show some initial science results related to measured upper limits on gravitational wave signals. Finally Z will describe new directions including advanced detectors and joint efforts with other fields of astronomy.

Camp, Jordan B.↗

Post-CDR Thermal Design and Analysis of the Starburst Instrument

The StarBurst Multimessenger Pioneer is a small satellite serving as a wide-field gamma-ray observatory designed to detect the initial emissions of short gamma ray bursts, electromagnetic indicators of neutron star mergers. This paper will detail the thermal design and analysis of the instrument, which includes both the control electronics and crystal detector units (CDUs). The CDUs are a critical component essential to mission success and have the narrowest temperature range, however the CDU thermal model is low fidelity at the time of Critical Design Review (CDR) before a final CDU design is completed. Therefore, a more detailed CDU model is created for post-CDR analysis to update the passive Thermal Control System (TCS) design and efficiently maintain the operational and survival temperature limits with minimal heater power. Including the additional detail is necessary to determine the final Multilayer Insulation (MLI) design, including material selection and coverage, coating selection, and required heater power.

thermal design↗

Post-CDR Thermal Design and Analysis of the Starburst Instrument

The StarBurst Multimessenger Pioneer is a small satellite serving as a wide-field gamma-ray observatory designed to detect the initial emissions of short gamma ray bursts, electromagnetic indicators of neutron star mergers. This paper will detail the thermal design and analysis of the instrument, which includes both the control electronics and crystal detector units (CDUs). The CDUs are a critical component essential to mission success and have the narrowest temperature range, however the CDU thermal model is low fidelity at the time of Critical Design Review (CDR) before a final CDU design is completed. Therefore, a more detailed CDU model is created for post-CDR analysis to update the passive Thermal Control System (TCS) design and efficiently maintain the operational and survival temperature limits with minimal heater power. Including the additional detail is necessary to determine the final Multilayer Insulation (MLI) design, including material selection and coverage, coating selection, and required heater power.

thermal design↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

The low-energy secondary cosmic ray flux: Detectors in iron meteorites

The cosmic ray-produced nuclides in the interiors of very large bodies are mainly due to secondary particle reactions. The records of low-energy products, specifically the neutron capture products in meteorites, may provide new information regarding multi-stage irradiation and parent body break-ups. Noble gas nuclides, in general, are the best candidates for these investigations. The troilite nodules of iron meteorites contain very low amounts of trapped gas and, because of their elemental abundance systematics of suitable target elements for low energy production of noble gas nuclides, they are ideal candidates for this purposes. Results of a study of noble gases and nitrogen in a troilite nodule of the Cape York iron are presented.

Murty, S. V. S.↗

Search for lightly ionizing particles in superCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e/(3 × 105) as well as the strongest limits for charges ≤ e/160, with a minimum intensity of 1.36 × 10-7 cm-2s-1sr-1 at charge e/160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulationmore » study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10-6 cm-2s-1. The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.« less

Banik, Samir↗

A Concept for the Inclusion of Analytical and Computational Capability in Existing Systems for Measurement of Neutron Flux

For approximately two decades, efforts have been sponsored by NASA's Marshall Space Flight Center to make possible high-speed, automated classification and quantification of constituent materials in various harsh environments. MSFC, along with the Air Force/Arnold Engineering Development Center, has led the work, developing and implementing systems that employ principles of emission and absorption spectroscopy to monitor molecular and atomic particulates in gas plasma of rocket engine flow fields. One such system identifies species and quantifies mass loss rates in H2/O2 rocket plumes. Other gases have been examined and the physics of their detection under numerous conditions were made a part of the knowledge base for the MSFC/USAF team. Additionally, efforts are being advanced to hardware encode components of the data analysis tools in order to address real-time operational requirements for health monitoring and management. NASA has a significant investment in these systems, warranting a spiral approach that meshes current tools and experience with technological advancements. This paper addresses current systems - the Optical Plume Anomaly Detector (OPAD) and the Engine Diagnostic Filtering System (EDIFIS) - and discusses what is considered a natural progression: a concept for migrating them towards detection of high energy particles, including neutrons and gamma rays. The proposal outlines system development to date, basic concepts for future advancements, and recommendations for accomplishing them.

Patrick, Clinton↗

Machine learning inversion of interatomic force constants from single-crystal inelastic neutron scattering

Atomic vibrations govern many macroscopic properties of materials, but experiments to comprehensively probe them remain challenging. Inelastic neutron scattering (INS) is a powerful technique to map phonon dispersions in crystals, especially when leveraging modern time-of-flight (ToF) spectrometers with large detectors. However, efficiently and robustly extracting interatomic force constants (FCs) parameterizing phonon dynamics from experimental spectra remains a bottleneck due to the complexity and high dimensionality of ToF INS datasets. Here, we present a machine learning approach for the direct inversion of FCs from single-crystal INS measurements. The framework leverages synthetic training data generated using universal machine-learned force fields and an efficient physics-based forward model. We benchmark two neural architectures–one emphasizing structured latent representation learning and the other direct, supervised spectral regression–across simulated datasets for two materials under idealized and noisy conditions. The latent-representation model is subsequently applied to experimental single-crystal INS data on germanium. The model is shown to reproduce FCs derived from both first-principles simulations and from iterative optimization, and furthermore achieves reliable inference even from sparse, single-orientation measurements representing short data acquisitions. Analysis of the learned latent space reveals semantically continuous and physically interpretable encodings that support strong cross-domain generalization. By bridging theoretical and experimental domains, we establish a path toward rapid inversion of experimental spectra and data-driven interpretation of temperature-dependent lattice dynamics.

42 ENGINEERING↗

Search for Lightly Ionizing Particles in SuperCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e /(3 × 10 5 ) as well as the strongest limits for charges ≤ e /160, with a minimum intensity of 1.36 × 10 -7 cm -2 s -1 sr -1 at charge e /160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulation study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10 -6 cm -2 s -1 . The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.

Banik, Samir↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shape evolution of neutron-rich 106,108,110 Mo isotopes in the triaxial degree of freedom

Background: Neutron-rich nuclei with mass number between 100 and 110 attract much attention, since several kinds of shapes, such as spherical, prolate, oblate, and triaxial shapes, are predicted. In particular, for neutron-rich Mo isotopes, different models predict different magnitudes and rigidity of triaxial deformation. Previous interpretations of experimental results based solely on low-lying $2^+_2$ states are insufficient to distinguish between the rigid triaxial shape, $\gamma$ vibration, or $\gamma$-soft rotor. Purpose: The shape evolution of 106 Mo, 108 Mo, and 110 Mo is investigated through their $2^+_1$-state lifetimes, decay-branching ratios of the $2^+_2$ state, and energies of the low-lying collective excited states with $K^π = 0^+, 2^+$, and $4^+$. Method: $\beta$-delayed $\gamma$-ray spectroscopy was employed for neutron-rich Nb and Zr isotopes produced at the RIKEN RI Beam Factory to populate excited states in 106 Mo, 108 Mo, and 110 Mo. The EUroball-RIKEN Cluster Array was used for high-resolution $\gamma$-ray detection and lifetimes of the $2^+_1$ states were determined using the UK fast-timing array of LaBr 3 (Ce) detectors. Results: New $\gamma$-ray transitions and levels are reported, including newly assigned $0^+_2$ states in 108,110 Mo. Quadrupole deformations were obtained for 106,108,110 Mo from their $2^+_1$ energies and lifetimes. The $\beta$-delayed neutron-emission probabilities of 108 Nb and 110 Nb were determined by examining the $\gamma$ rays of their respective daughter decays. Conclusions: In this work, the even-odd energy staggering in the $2^+_2$ band was compared with typical patterns of the $\gamma$-vibrational band, rigid triaxial rotor, and $\gamma$-soft rotor. The very small even-odd staggering of 106 Mo, 108 Mo, and 110 Mo favors a $\gamma$-vibrational band assignment. The kinematic moment of inertia for the $2^+_2$ band showed a trend similar to the ground-state band, which is as expected for the $\gamma$-vibrational band. Beyond-mean-field calculations employing the constrained Hartree-Fock-Bogoliubov and local quasiparticle-random-phase approximation method using the SLy5 + T interaction reproduced the ground and $2^+_2$ bands in 106 Mo and 108 Mo. The collective wave functions are consistent with the interpretation of the $2^+_2$ band as the $\gamma$-vibrational band of the prolate shape. However, the staggering pattern observed in 110 Mo differs from the one suggested in the calculations which predict a $\gamma$-soft rotor. There was no experimental indication of the oblate shape or the $\gamma$-soft rotor predicted in these Mo isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Use of a Longitudinally Polarized Target with CLAS12

Run Group C comprises eight experiments utilizing the CLAS12 detector system in Hall B at Jefferson Lab to study the multidimensional partonic structure of nucleons. The experiments scatter electrons from polarized protons and neutrons in samples of solid NH$_3$ and ND$_3$, dynamically polarized at a temperature of 1 K in a 5 T magnetic field. After a brief description of the target system, the current status of the target and preliminary results of its performance in the experiment are presented.

Keith, Christopher↗