Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Reagent-free and portable detection of Bacillus anthracis spores using a microfluidic incubator and smartphone microscope

Rapid, cost-effective bacterial detection systems are needed to respond to potential biothreat events. Here we report the use of smartphone-based microscopy in combination with a simple microfluidic incubation device to detect 5000 Bacillus anthracis spores in 3 hours. This field-deployable approach is compatible with real-time PCR for secondary confirmation.

B. anthracis↗

Implementation on a desktop computer of the real time feedback control loop of a scanning probe microscope

A software package has been developed to implement the real time feedback control loop needed in scanning probe microscopy on a general purpose desktop computer of the current high-speed/multicore generation. The main features of the implementation of both the feedback loop and the control of the experiment on the same computer are discussed. The package can work with several general purpose data acquisition boards and can be extended in a modular way to further board models; timing performance has been tested with several hardware configurations and some applications common in scanning probe microscopy. The package is available under an Open Source license.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Room temperature electron transport properties of single C{sub 60} studied using scanning tunneling microscope and reak junctions.

We report the measurements of the electron transport of an individual C{sub 60} molecule through the combination of two experimental efforts. The nanometer-sized junctions were fabricated using electromigration combined with electron beam lithography and shadow effect evaporation. We performed the scanning tunneling microscopy/spectroscopy measurements of dispersed C{sub 60} molecules which were deposited on a highly ordered pyrolytic graphite substrate. The single electron tunneling through a single C{sub 60} molecule due to the Coulomb blockage effect is observed at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-lived frequency shifts observed in a magnetic resonance force microscope experiment following microwave irradiation of a nitroxide spin probe

We introduce a spin-modulation protocol for force-gradient detection of magnetic resonance that enables the real-time readout of longitudinal magnetization in an electron spin resonance experiment involving fast-relaxing spins. We applied this method to observe a prompt change in longitudinal magnetization following the microwave irradiation of a nitroxide-doped perdeuterated polystyrene film having an electron spin-lattice relaxation time of T{sub 1}{approx}1ms. The protocol allowed us to discover a large, long-lived cantilever frequency shift. Based on its magnitude, lifetime, and field dependence, we tentatively attribute this persistent signal to deuteron spin magnetization created via transfer of polarization from nitroxide spins.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scanning probe microscope simulator for the assessment of noise in scanning probe microscopy controllers

We present an electronic circuit that allows to calibrate and troubleshoot scanning probe microscopy (SPM) controllers with respect to their noise performance. The control signal in an SPM is typically highly nonlinear—the tunneling current in scanning tunneling microscopy (STM) varies exponentially with distance. The exponential current-versus-voltage characteristics of diodes allow to model the current dependence in STM. Additional inputs allow to simulate the effects of external perturbations and the reactions of the control electronics. We characterized the noise performance of the feedback controller using the apparent topography roughness of recorded images. For a comparison of different STM controllers, an optimal gain parameter was determined by exploring settling times through a rectangular perturbation signal. We used the circuit to directly compare the performance of two types of SPM controllers used in our laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Luminescence of Quantum Dots by Coupling with Nonradiative Surface Plasmon Modes in a Scanning Tunneling Microscope

The electronic coupling between quantum dots (QDs) and surface plasmons (SPs) is investigated by a luminescence spectroscopy based on scanning tunneling microscopy (STM). We show that tunneling luminescence from the dot is excited by coupling with the nonradiative plasmon mode oscillating at the metallic tunneling gap formed during the STM operation. This approach to the SP excitation reveals aspects of the SP-QD coupling not accessible to the more conventional optical excitation of SPs. In the STM, luminescence from the dot is observed when and only when the SP is in resonance with the fundamental transition of the dot. The tunneling luminescence spectrum also suggests that excited SP-QD hybrid states can participate in the excitation of QD luminescence. Not only the SP excitation regulates the QD luminescence but the presence of the dot at the tunneling gap imposes restrictions to the SP that can be excited in the STM, in which the SP cannot exceed the energy of the fundamental transition of the dot. The superior SP-QD coupling observed in the STM is due to the tunneling gap acting as a tunable plasmonic resonator in which the dot is fully immersed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microscope of glassy relaxation in femtogram samples: Charge offset drift in the single electron transistor

By measuring the long-term charge offset drift in single electron tunneling transistors, we have observed a transient relaxation after fabrication which is correlated with the presence of amorphous insulator. The temperature and time dependence of the transient relaxation are both in agreement with an extension of the standard model for two-level systems in glasses. This technique, which is sensitive to atomic scale motion in femtogram-sized samples, offers the possibility of a technique for investigation of glassy relaxation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale Proximity Effect in the High-Temperature Superconductor Bi2Sr2CaCu2O8+δ Using a Scanning Tunneling Microscope

High-temperature cuprate superconductors exhibit extremely local nanoscale phenomena and strong sensitivity to doping. While other experiments have looked at nanoscale interfaces between layers of different dopings, we focus on the interplay between naturally inhomogeneous nanoscale regions. Using scanning tunneling microscopy to carefully track the same region of the sample as a function of temperature, we show that regions with weak superconductivity can persist to elevated temperatures if bordered by regions of strong superconductivity. This suggests that it may be possible to increase the maximum possible transition temperature by controlling the distribution of dopants.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Probe Length Effect on the Cantilever of an Atomic Force Microscope in Measuring the Mechanical Properties of Living Neurons

Living sensory neurons were studied by atomic force microscopy in the PeakForce QNM mode under near-physiological conditions. The dependence of the measured apparent Young modulus of cells on the ratio of the probe height to the beam length on a used cantilever was revealed. A qualitative explanation based on the analysis of beam strains in two limit cases, in which the probe slides over a studied object and the probe sticks to the latter, was given to the obtained result. It was proposed to classify native cells by the character of their interaction with the probe (sliding or sticking).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time Studies of Battery Electrochemical Reactions Inside a Transmission Electron Microscope

We report the development of new experimental capabilities and ab initio modeling for real-time studies of Li-ion battery electrochemical reactions. We developed three capabilities for in-situ transmission electron microscopy (TEM) studies: a capability that uses a nanomanipulator inside the TEM to assemble electrochemical cells with ionic liquid or solid state electrolytes, a capability that uses on-chip assembly of battery components on to TEM-compatible multi-electrode arrays, and a capability that uses a TEM-compatible sealed electrochemical cell that we developed for performing in-situ TEM using volatile battery electrolytes. These capabilities were used to understand lithiation mechanisms in nanoscale battery materials, including SnO 2 , Si, Ge, Al, ZnO, and MnO 2 . The modeling approaches used ab initio molecular dynamics to understand early stages of ethylene carbonate reduction on lithiated-graphite and lithium surfaces and constrained density functional theory to understand ethylene carbonate reduction on passivated electrode surfaces.

25 ENERGY STORAGE↗

Electron optics for 4 MeV ultrafast electron microscope - Final Report

Calabazas Creek Research, Inc. (CCR), in collaboration with Northern Illinois University (NIU), proposed to leverage CCR’s experience in electron beam generation and focusing and NIU’s experience in electron microscopy to develop a 4 MeV UEM with sub-ns temporal resolution and 0.3 nm spatial resolution with a relative energy spread of 10-5. Important design tools for the program were CCR’s 3D, finite element code Beam Optics Analyzer (BOA) and the photocathode design code PHOTOQE. However, early in the program it became clear that information necessary to use PHOTOQE was not available, and the program focused on the modifying to BOA to provide the required functionality.

beam optics simulation↗

Transmission electron microscope (TEM), BBOP

These transmission electron microscopy (TEM) images indicate representative particle shapes and mixing states collected during the BBOP campaign. Aerosol particles were collected onto lacey-carbon substrates.

54 ENVIRONMENTAL SCIENCES↗