Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Internal Charging Design Environments for the Earths Radiation Belts

Relativistic electrons in the Earth's radiation belts are a widely recognized threat to spacecraft because they penetrate lightly shielded vehicle hulls and deep into insulating materials where they accumulate to sufficient levels to produce electrostatic discharges. Strategies for evaluating the magnitude of the relativistic electron flux environment and its potential for producing ESD events are varied. Simple "rule of thumb" estimates such as the widely used 10(exp 10) e-/sq cm fluence within 10 hour threshold for the onset of pulsing in dielectric materials provide a quick estimate of when to expect charging issues. More sophisticated strategies based on models of the trapped electron flux within the Earth s magnetic field provide time dependent estimates of electron flux along spacecraft orbits and orbit integrate electron flux. Finally, measurements of electron flux can be used to demonstrate mean and extreme relativistic electron environments. This presentation will evaluate strategies used to specify energetic electron flux and fluence environments along spacecraft trajectories in the Earth s radiation belts.

Minow, Joseph I.↗

Internal Electrostatic Discharge Testing of Inert Solid Rocket Motor Materials

Jupiter’s moon Europa is believed to have a global liquid-water ocean beneath its icy surface. As such, it is a highly interesting destination for explorers seeking signs of life outside of Earth. This interest has given rise to the Europa Lander Mission [Hand, et al., 2017]. The central goal of the Europa Lander Mission is to place a stationary lander on Europa and make surface and sub-surface measurements, dramatically improving understanding of this Jovian moon, and potentially detecting signs of life.Placing a lander on Europa will require multiple spacecraft elements deployed across a multi-year mission timeline. Some of the key elements include: a large payload capacity rocket, such as the Space Launch System (SLS), capable of providing direct Jupiter orbit insertion; a solar-powered carrier; a de-orbit system; a sky crane landing system; and, of course, the surface lander. A noteworthy fact is that the current design requires a large solid rocket motor to provide the necessary braking thrust for the de-orbit stage. While solid rocket motors have been used extensively by NASA during launch, in-space use has been limited. In addition to the normal challenges associated with a long-distance planetary mission, the Europa Lander Mission must also contend with the high-radiation environment associated with the Jovian system. The size of Jupiter, combined with its magnetic field strength, and rotation speed, result in a harsh radiation environment composed of high energy charged particles (ions and electrons) as well as high-temperature plasmas [de Soria-Santacruz Pich, 2016]. Due to this high-radiation environment, each component of the Europa Lander spacecraft must be evaluated to determine its radiation dose tolerance and its likelihood for experiencing electrostatic charging (and discharging). In general, metal components in a Jovian environment do not pose a concern for radiation degradation; in fact, metal structures and closeouts can act as radiation shielding for the more sensitive components. Charging of a metal component is only an issue if the component is not properly grounded to the spacecraft chassis. However, electrically insulating materials, such as polymers, are subject to radiation degradation as well as surface and internal charging, and therefore require extra scrutiny. The focus of this paper will be on the insulating materials that are commonly used inside solid rocket motors. The special application of a solid rocket motor used in space after a relatively long duration flight, combined with the high energy electron environment in the Jovian system, raises concerns about the possibility of significant charging and discharging leading to reduced performance.

Schneider, Todd A.↗

V3FIT: a code for three-dimensional equilibrium reconstruction

The V3FIT code for performing equilibrium reconstruction in three-dimensional plasmas is described. It is a modular code that has the potential to be coupled with a variety of equilibrium solvers to compute the externally measured response to an arbitrary internal state of the plasma. Singular value decomposition is used to identify the dominant components of the plasma state that can be accurately determined by the reconstruction process and to guide the minimization of the ! " 2 variance-normalized mismatch between the measured and computed signals. Comparison of a tokamak plasma equilibrium computed by V3FIT and by the axisymmetric equilibrium reconstruction code EFIT is presented. V3FIT is used to reconstruct an axisymmetric DIII-D equilibrium using experimentally observed magnetic diagnostic signals. Three-dimensional reconstructions of stellarator plasma equilibria in the CTH device show the code behaves as expected in the presence of experimental noise, appropriately ignores near-singular directions in parameter space, and robustly reconstructs equilibria starting from substantially different initial parameter values.

CIRCULAR CROSS-SECTION↗

Convection in Neptune's magnetosphere

It is assumed that nonthermal escape from Triton's atmosphere produces a co-orbiting torus of unionized gas (presumably nitrogen and hydrogen) that subsequently becomes ionized by electron impact to populate a partial Triton plasma torus analogous to the Io plasma torus in Jupiter's magnetosphere. Centrifugal and magnetic-mirror forces confine the ions to a plasma sheet located between the magnetic and centrifugal equators. The ionization rate, and hence the torus ion concentration, is strongly peaked at the two points (approximately 180 deg apart in longitude) at which Triton's orbit intersects the plasma equator. During the course of Neptune's rotation these intersection points trace out two arcs roughly 75 deg in longitudinal extent, which we take to be the configuration of the resulting (partial) plasma torus. The implied partial ring currents produce a quadrupolar (four-cell) convection system that provides rapid outward transport of plasma from the arcs. Ring-current shielding, however, prevents this convection system from penetrating very far inside the plasma-arc distance. It is suggested that this convection/shielding process accounts for the radial confinement of trapped particles (150 keV or greater) within L = 14.3 as observed by the Voyager LECP instrument.

Hill, T. W.↗

Nondestructive Evaluation Techniques for Development and Characterization of Carbon Nanotube Based Superstructures

Recently, multiple commercial vendors have developed capability for the production of large-scale quantities of high-quality carbon nanotube sheets and yarns. While the materials have found use in electrical shielding applications, development of structural systems composed of a high volume fraction of carbon nanotubes is still lacking. A recent NASA program seeks to address this by prototyping a structural nanotube composite with strength-toweight ratio exceeding current state-of-the-art carbon fiber composites. Commercially available carbon nanotube sheets, tapes, and yarns are being processed into high volume fraction carbon nanotube-polymer nanocomposites. Nondestructive evaluation techniques have been applied throughout this development effort for material characterization and process control. This paper will report on the progress of these efforts, including magnetic characterization of residual catalyst content, Raman scattering characterization of nanotube diameter, defect ratio, and nanotube strain, and polarized Raman scattering for characterization of nanotube alignment.

Wincheski, Buzz↗

Probing the Electronic Structure of a Thorium Nitride Complex by Solid-State 15N NMR Spectroscopy

The solid-state 15N NMR powder spectra of the thorium nitride complex, [K(18-crown-6)(THF)2][(R2N)3Th(m-15N)(Th(NR2)3] ([K][1-15N], R = SiMe3), and the thorium amide complex, [Th(NR2)3(15NH2)] (2-15N) were recorded. The spectrum for [K][1-15N] represents the first reported solid-state 15N NMR data for an actinide nitride complex. The experimentally measured tensor spans are 847 ppm for [K][1-15N] and 237 ppm for 2-15N. Both shielding tensors exhibit a near-zero asymmetry parameter, which for [K][1-15N] is consistent with a local rotational symmetry of its 15N-labelled nitride ligand. For 2-15N, the lack of asymmetry can be rationalized by a quasi-free Th-NH2 bond rotation in the solid-state. DFT calculations overestimate the tensor span somewhat for [K][1-15N], but provide isotropic shifts in good agreement with both the solid-state and solution values for both complexes. Natural localized molecular orbital (NLMO) analyses of the nuclear shielding reveal that the larger tensor span in [K][1-15N] vs. 2-15N is primarily a consequence of more pronounced covalency of the N-Th bonds, and large spin-orbit coupling due to significant Th 5f orbital contribution to those bonds, impacting the principal components of the shielding tensor perpendicular to the Th-N-Th axis. Overall, our analysis confirms the involvement of the 5f orbitals in Th-N multiple bonds, and further demonstrates the value of solid-state NMR spectroscopy for interrogating actinide-ligand bonding.

actinides, covalent bonding, Nuclear Magnetic Reso↗

Replacement of a Photomultiplier Tube with Silicon Photomultipliers for use in Safeguards Applications

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor scintillating materials for radiation detection purposes. The systems are sometimes limited by disadvantages in the PMTs that may degrade their performance, including temperature dependence and variation with magnetic field. Instrumentation engineering must also contend with a potentially large volume relative to the active scintillator volume, fragility, and high voltage requirements. One possible alternative is an array of silicon photomultipliers (SiPMs). Measurements were made with a 5.04x5.04-cm sensL J-series SiPM array and a 7.62cm Hamamatsu PMT. We demonstrated how the SiPM bias can be sufficiently altered to remove the effects of temperature variation encountered in environments where nuclear safeguards work is often performed. Finally, we evaluated a method of determining enrichment levels of 235 U at various levels and shielding configurations, using both the PMT-mounted and SiPM-mounted scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutral atom analyzers for diagnosing hot plasmas: A review of research at the ioffe physicotechnical institute

Research on neutral particle diagnostics of thermonuclear plasmas that has been carried out in recent years at the Ioffe Physicotechnical Institute of the Russian Academy of Sciences (St. Petersburg, Russia) is reviewed. Work on the creation and improvement of neutral atom analyzers was done in two directions: for potential applications (in particular, on the International Thermonuclear Experimental Reactor, which is now under construction at Cadarache in France) and for investigation of the ion plasma component in various devices (in particular, in the largest tokamaks, such as JET, TFTR, and JT-60). Neutral atom analyzers are the main tool for studying the behavior of hydrogen ions and isotopes in magnetic confinement systems. They make it possible to determine energy spectra, to perform the isotope analysis of atom fluxes from the plasma, to measure the absolute intensity of the fluxes, and to record how these parameters vary with time. A comparative description of the analyzers developed in recent years at the Ioffe Institute is given. These are ACORD-12/24 analyzers for recording 0.2-100-keV hydrogen and deuterium atoms with a tunable range of simultaneously measured energies, CNPA compact analyzers for a fixed energy gain in the ranges 80-1000 eV and 0.8-100 keV, an ISEP analyzer for simultaneously recording the atoms of all the three hydrogen isotopes (H, D, and T) in the energy range 5-700 keV, and GEMMA analyzers for recording atom fluxes of hydrogen and helium isotopes in the range 0.1-4 MeV. The scintillating detectors of the ISEP and GEMMA analyzers have a lowered sensitivity to neutrons and thus can operate without additional shielding in neutron fields of up to 10{sup 9} n/(cm{sup 2} s). These two types of analyzers, intended to operate under deuterium-tritium plasma conditions, are prototypes of atom analyzers created at the Ioffe Institute for use in the International Thermonuclear Experimental Reactor. With these analyzers, a number of new results have been obtained in recent years in various devices. Some results are presented from investigation of ions in the Globus-M spherical tokamak, the W7-AS stellarator, and the JET tokamak by means of the analyzers developed at the Ioffe Institute. Challenges and opportunities for applying these diagnostics in the International Thermonuclear Experimental Reactor project are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized Geometry for Superconducting Sensing Coils

An optimized geometry has been proposed for superconducting sensing coils that are used in conjunction with superconducting quantum interference devices (SQUIDs) in magnetic resonance imaging (MRI), magnetoencephalography (MEG), and related applications in which magnetic fields of small dipoles are detected. In designing a coil of this type, as in designing other sensing coils, one seeks to maximize the sensitivity of the detector of which the coil is a part, subject to geometric constraints arising from the proximity of other required equipment. In MRI or MEG, the main benefit of maximizing the sensitivity would be to enable minimization of measurement time. In general, to maximize the sensitivity of a detector based on a sensing coil coupled with a SQUID sensor, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. Simply making the coil larger may increase its self-inductance and does not necessarily increase sensitivity because it also effectively increases the distance from the sample that contains the source of the signal that one seeks to detect. Additional constraints on the size and shape of the coil and on the distance from the sample arise from the fact that the sample is at room temperature but the coil and the SQUID sensor must be enclosed within a cryogenic shield to maintain superconductivity.

Eom, Byeong Ho↗

Increasing Flexibility of Polymers in the Application of Complex Space Craft Heat Shield Geometries

Highly crosslinked polymers, commonly utilized in spacecraft component fabrication, especially for heatshields, have historically encountered challenges due to their inherent brittleness. To overcome this issue, researchers have explored the incorporation of additives into the polymer backbone to enhance flexibility and durability. This study aims to improve the flexibility and durability of highly crosslinked polymers by introducing long-chain aliphatic silicon-based additives with varying molecular weights into the polymer backbone. By increasing the flexibility of these brittle polymers, they can be effectively employed in constructing intricate curvatures for heatshields, eliminating the need for gap fillers. In this study, we investigated six different additives, comparing them to a highly crosslinked high-temperature polymer used as a baseline. Various characterization techniques, including thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), dilatometry, dynamic mechanical analysis (DMA), nuclear magnetic resonance (NMR), and Fourier transform infrared spectroscopy (FTIR), were employed to assess the properties of the materials. The FTIR and NMR results indicated the successful incorporation of the silicon-based additives into the polymer backbone. Furthermore, thermal characterization results demonstrated that certain additives exhibited superior flexibility and lower densities compared to the baseline polymer.

Tane Boghozian↗

Microwave Processing of Planetary Surfaces for the Extraction of Volatiles

In-Situ Resource Utilization will be necessary for sustained exploration of space. Volatiles are present in planetary soils, but water by far has the most potential for effective utilization. The presence of water at the lunar poles, Mars, and possibly on Phobos opens the possibility of producing LOX for propellant. Water is also a useful radiation shielding material , and valuable to replenish expendables (water and oxygen) required for habitation in space. Because of the strong function of water vapor pressure with temperature, heating soil effectively liberates water vapor by sublimation. Microwave energy will penetrate soil and heat from within much more efficiently than heating from the surface with radiant heat. This is especially true under vacuum conditions since the heat transfer rate is very low. The depth of microwave penetration is a strong function of the microwave frequency and to a lesser extent on soil dielectric properties. Methods for complex electric permittivity and magnetic permeability measurement are being developed and used for measurements of lunar soil simulants. A new method for delivery of microwaves deep into a planetary surface is being prototyped with laboratory experiments and modeled with COMSOL MultiPhysics. We are planning to set up a planetary testbed in a large vacuum chamber in the coming year. Recent results are discussed.

Ethridge, Edwin C.↗

Simulation of Earth-Moon-Mars Environments for the Assessment of Organ Doses

Space radiation environments for historically large solar particle events (SPE) and galactic cosmic rays (GCR) at solar minimum and solar maximum are simulated in order to characterize exposures to radio-sensitive organs for missions to low-Earth orbit (LEO), moon, and Mars. Primary and secondary particles for SPE and GCR are transported through the respective atmosphere of Earth or Mars, space vehicle, and astronaut s body tissues using the HZETRN/QMSFRG computer code. In LEO, exposures are reduced compared to deep space because particles are deflected by the Earth s magnetic field and absorbed by the solid body of the Earth. Geomagnetic transmission function as a function of altitude was applied for the particle flux of charged particles, and the shift or the organ exposures to higher velocity or lower stopping powers compared to those in deep space were analyzed. In the transport through Mars atmosphere, a vertical distribution of atmospheric thickness was calculated from the temperature and pressure data of Mars Global Surveyor, and the directional cosine distribution was implemented to describe the spherically distributed atmospheric distance along the slant path at each altitude. The resultant directional shielding by Mars atmosphere at solar minimum and solar maximum was used for the particle flux simulation at various altitudes on the Martian surface. Finally, atmospheric shielding was coupled with vehicle and body shielding for organ dose estimates. We made predictions of radiation dose equivalents and evaluated acute symptoms at LEO, moon, and Mars at solar minimum and solar maximum.

Kim, Myung-Hee↗

Design, performance, and grounding aspects of the International Thermonuclear Experimental Reactor ion cyclotron range of frequencies antenna

ITER's Ion Cyclotron Range of Frequencies (ICRF) system [Lamalle et al., Fusion Eng. Des. 88, 517–520 (2013)] comprises two antenna launchers designed by CYCLE (a consortium of European associations listed in the author affiliations above) on behalf of ITER Organisation (IO), each inserted as a Port Plug (PP) into one of ITER's Vacuum Vessel (VV) ports. Each launcher is an array of 4 toroidal by 6 poloidal RF current straps specified to couple up to 20 MW in total to the plasma in the frequency range of 40 to 55 MHz but limited to a maximum system voltage of 45 kV and limits on RF electric fields depending on their location and direction with respect to, respectively, the torus vacuum and the toroidal magnetic field. A crucial aspect of coupling ICRF power to plasmas is the knowledge of the plasma density profiles in the Scrape-Off Layer (SOL) and the location of the RF current straps with respect to the SOL. The launcher layout and details were optimized and its performance estimated for a worst case SOL provided by the IO. The paper summarizes the estimated performance obtained within the operational parameter space specified by IO. Aspects of the RF grounding of the whole antenna PP to the VV port and the effect of the voids between the PP and the Blanket Shielding Modules (BSM) surrounding the antenna front are discussed. These blanket modules, whose dimensions are of the order of the ICRF wavelengths, together with the clearance gaps between them will constitute a corrugated structure which will interact with the electromagnetic waves launched by ICRF antennas. The conditions in which the grooves constituted by the clearance gaps between the blanket modules can become resonant are studied. Simple analytical models and numerical simulations show that mushroom type structures (with larger gaps at the back than at the front) can bring down the resonance frequencies, which could lead to large voltages in the gaps between the blanket modules and perturb the RF properties of the antenna if they are in the ICRF operating range. The effect on the wave propagation along the wall structure, which is acting as a spatially periodic (toroidally and poloidally) corrugated structure, and hence constitutes a slow wave structure modifying the wall boundary condition, is examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave Processing of Planetary Surfaces for Volatile Extraction

In-Situ Resource Utilization will be necessary for sustained exploration of space. Volatiles are present in planetary soils, but water by far has the strongest potential for effective utilization. The presence of water at the lunar poles, Mars, and possibly on Phobos opens the possibility of producing LOX for propellant. Water is also a useful radiation shielding material and water (and oxygen) are expendables that are also required for habitation in space. Because of the strong function of water vapor pressure with temperature, heating soil effectively liberates water vapor by sublimation. Microwave energy will penetrate soil and heat from within much more efficiently than heating from the surface with radiant heat. This is especially true under vacuum conditions since the heat transfer rate is very low. The depth of microwave penetration is a strong function of the microwave frequency and to a lesser extent on soil dielectric properties. Methods for measuring the complex electric permittivity and magnetic permeability are being developed and have been measured for some lunar soil simulants at 0.5, 2.45, and 10 GHz from room temperature down to liquid nitrogen temperature. A new method for delivery of microwaves deep into a planetary surface is being prototyped with laboratory experiments and modeled with COMSOL MultiPhysics. We have plans to set up a planetary testbed in a large vacuum chamber in the coming year. Recent results will be presented.

Ethridge, Edwin C.↗

Lockout/Tagout (LOTO) Simulator

The Lockout/Tagout (LOTO) Simulator is a portable training aid, or demonstration tool, designed to physically illustrate real-time critical-safety concepts of electrical lockout/tagout. The objective is to prevent misinterpretations of what is off and what is on during maintenance and repair of complex electrical systems. The simulator is designed in the form of a hinged box that opens up and stands on its own as an easel for demonstrations. On the outer face of the unit is a simulated circuit breaker box housing the switches. The breakers control the main power to the unit, a light bulb, and an electrical control cabinet. The light bulb is wired so that either of two breakers can provide power to it. When power is sent to the electrical control cabinet, a red indicator light illuminates. Inside the cabinet is the power supply from a personal computer. The power supply produces a 12-V dc output that is sent over to a small fan next to it, also from a computer, and an amber light on the front of the cabinet illuminates. A separate switch powers the fan on and off. The power supply is behind a plastic shield to protect against exposure to live conductors. Electrical banana jacks are mounted in the plastic shield to allow a voltmeter to be connected safely when opening the cabinet and taking a meter reading to verify de-energization as part of a simulation exercise. This LOTO simulator prototype is designed and fabricated as an all-in-one unit. All accessories can be stored inside the hinged case, and there is a handle on top for ease of transport. The circuit breaker labels attach with hook and loop fasteners so that they may be moved and changed to fit the training or demonstration scenario. The warning signs and labels on the electrical control box are magnetic, allowing for easy reconfiguration to emulate different equipment setups. A specially designed magnetic cover was made to disguise the indicator lights for demonstrations when these indicators are not used. The cover is disguised as an arc flash safety label that would typically be found on such a cabinet. One indicator light has a separate switch that can take it offline. This is to allow for demonstration to trainees on why it is important not to completely rely on indicator lights, but that they should always take a meter reading at the exposed conductors to absolutely verify de-energization before exposure. A clear plastic barrier and banana jacks inside the cabinet provide a safe way to plug in a voltmeter for demonstrations without exposure to the hazards of energized equipment. A small remote control unit is wired into the fan circuit. The remote allows the demonstrator to turn the fan on and off, provided that all of the breakers and switches leading to it are configured on as well. The remote feature was added in order to demonstrate the importance of starting the lockout/tagout task with energized equipment, then powering it down, isolating it, and locking it out to ensure that the correct breakers have been locked out.

Scheer, Jennifer↗

Development of imaging bolometers for magnetic fusion reactors (invited)

Imaging bolometers utilize an infrared (IR) video camera to measure the change in temperature of a thin foil exposed to the plasma radiation, thereby avoiding the risks of conventional resistive bolometers related to electric cabling and vacuum feedthroughs in a reactor environment. A prototype of the IR imaging video bolometer (IRVB) has been installed and operated on the JT-60U tokamak demonstrating its applicability to a reactor environment and its ability to provide two-dimensional measurements of the radiation emissivity in a poloidal cross section. In this paper we review this development and present the first results of an upgraded version of this IRVB on JT-60U. This upgrade utilizes a state-of-the-art IR camera (FLIR/Indigo Phoenix-InSb) (3-5 {mu}m, 256x360 pixels, 345 Hz, 11 mK) mounted in a neutron/gamma/magnetic shield behind a 3.6 m IR periscope consisting of CaF{sub 2} optics and an aluminum mirror. The IRVB foil is 7 cmx9 cmx5 {mu}m tantalum. A noise equivalent power density of 300 {mu}W/cm{sup 2} is achieved with 40x24 channels and a time response of 10 ms or 23 {mu}W/cm{sup 2} for 16x12 channels and a time response of 33 ms, which is 30 times better than the previous version of the IRVB on JT-60U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma fuelling with cryogenic pellets in the stellarator TJ-II

Cryogenic pellet injection is a widely used technique for delivering fuel to the core of magnetically confined plasmas. Indeed, such systems are currently functioning on many tokamak, reversed field pinch and stellarator devices. A pipe-gun-type pellet injector is now operated on the TJ-II, a low-magnetic shear stellarator of the heliac type. Cryogenic hydrogen pellets, containing between 3×10 18 and 4×10 19 atoms, are injected at velocities between 800 and 1200 m s -1 from its low-field side into plasmas created and/or maintained in this device by electron cyclotron resonance and/or neutral beam injection heating. In this paper, the first systematic study of pellet ablation, particle deposition and fuelling efficiency is presented for TJ-II. From this, light-emission profiles from ablating pellets are found to be in reasonable agreement with simulated pellet ablation profiles (created using a neutral gas shielding-based code) for both heating scenarios. In addition, radial offsets between recorded light-emission profiles and particle deposition profiles provide evidence for rapid outward drifting of ablated material that leads to pellet particle loss from the plasma. Finally, fuelling efficiencies are documented for a range of target plasma densities (~4×10 18 – ~2×10 19 m -3 ). These range from ~20%– ~85% and are determined to be sensitive to pellet penetration depth. Additional observations, such as enhanced core ablation, are discussed and planned future work is outlined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of MEMS-Based Microshutter Arrays for Optical Transmission Selection

A MEMS-based programmable aperture mask is under development at the NASA Goddard Space Flight Center. Termed the Microshutter (u-shutter) Array, the device will be used to control the transmission of light, with both high efficiency and contrast, to a multi-object spectrometer on the James Webb Space Telescope. Fabrication of the p-shutter array employs several novel designs and processing techniques. The current generation of micro-shutters consists of 128x64 pixel arrays with unit cell dimensions of 100x200 microns. Shutters are patterned in silicon nitride and sit on a 100 micron silicon frame that is DRIE etched below each shutter. The front and back sides of the device are shown. A magnetic cobalt-iron alloy patterned on top of the shutter allows it to be actuated 90 degrees out-of-plane, into the frame, by an external magnetic field. An electrode on the shutter and a vertical electrode on the sidewall of the frame, approximately 90pm deep, allow them to be electrostatically latched in their rotated position. The vertical electrode is deposited and patterned on the backside of the frame in a single step using a directionally controlled evaporation. Individual addressing of shutters for electrostatic latching is accomplished via a crosspoint addressing scheme, with no on-chip active components. A portion of an array with shutters in the open, latched, and closed positions is shown. Light loss at shutter edges is minimized by an overhanging aluminum light-shield that is anchored to the frame. A photoresist sacrificial layer is used to raise the light-shield up and over the 2 micron gap that surrounds each pixel. After completion, arrays are subjected to life cycle, environmental and optical testing. Fabricated devices have survived 10(exp 6) actuation cycles at both room and cryogenic temperatures and a 14g rms launch-simulation test. Optical testing has shown contrast measurements between open and closed shutters up to 10000:1.

Lynch, Bernard A.↗