Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

The JCMT BISTRO Survey: The Magnetic Field Strength in the Orion A Filament

We determine the magnetic field strength in the OMC 1 region of the Orion A filament via a new implementation of the Chandrasekhar–Fermi method using observations performed as part of the James Clerk Maxwell Telescope (JCMT) B-Fields In Star-forming Region Observations (BISTRO) survey with the POL-2 instrument. We combine BISTRO data with archival SCUBA-2 and HARP observations to find a plane-of-sky magnetic field strength in OMC 1 of B{sub pos}=6.6±4.7 mG, where δB{sub pos}=4.7 mG represents a predominantly systematic uncertainty. We develop a new method for measuring angular dispersion, analogous to unsharp masking. We find a magnetic energy density of ∼1.7×10{sup −7} J m{sup −3} in OMC 1, comparable both to the gravitational potential energy density of OMC 1 (∼10{sup −7} J m{sup −3}) and to the energy density in the Orion BN/KL outflow (∼10{sup −7} J m{sup −3}). We find that neither the Alfvén velocity in OMC 1 nor the velocity of the super-Alfvénic outflow ejecta is sufficiently large for the BN/KL outflow to have caused large-scale distortion of the local magnetic field in the ∼500 yr lifetime of the outflow. Hence, we propose that the hourglass field morphology in OMC 1 is caused by the distortion of a primordial cylindrically symmetric magnetic field by the gravitational fragmentation of the filament and/or the gravitational interaction of the BN/KL and S clumps. We find that OMC 1 is currently in or near magnetically supported equilibrium, and that the current large-scale morphology of the BN/KL outflow is regulated by the geometry of the magnetic field in OMC 1, and not vice versa.

79 ASTRONOMY AND ASTROPHYSICS↗

Resonantly-enhanced axion-photon regeneration

A resonantly-enhanced photon-regeneration experiment to search for the axion or axion-like particles is discussed. Photons enter a strong magnetic field and some are converted to axions; the axions can pass through an opaque wall and some may convert back to photons in a second high-field region. The photon regeneration is enhanced by employing matched Fabry-Perot optical cavities, with one cavity within the axion generation magnet and the second within the photon regeneration magnet. The optics for this experiment are discussed, with emphasis on the alignment of the two cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and optimization of arrays of neodymium iron boron-based magnets for magnetic tweezers applications

We present the design methodology for arrays of neodymium iron boron (NdFeB)-based magnets for use in magnetic tweezers devices. Using finite element analysis (FEA), we optimized the geometry of the NdFeB magnet as well as the geometry of iron yokes designed to focus the magnetic fields toward the sample plane. Together, the magnets and yokes form a magnetic array which is the basis of the magnetic tweezers device. By systematically varying 15 distinct shape parameters, we determined those features that maximize the magnitude of the magnetic field gradient as well as the length scale over which the magnetic force operates. Additionally, we demonstrated that magnetic saturation of the yoke material leads to intrinsic limitations in any geometric design. Using this approach, we generated a compact and light-weight magnetic tweezers device that produces a high field gradient at the image plane in order to apply large forces to magnetic beads. We then fabricated the optimized yoke and validated the FEA by experimentally mapping the magnetic field of the device. The optimization data and iterative FEA approach outlined here will enable the streamlined design and construction of specialized instrumentation for force-sensitive microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A peripheral component interconnect express-based scalable and highly integrated pulsed spectrometer for solution state dynamic nuclear polarization

High sensitivity, high data rates, fast pulses, and accurate synchronization all represent challenges for modern nuclear magnetic resonance spectrometers, which make any expansion or adaptation of these devices to new techniques and experiments difficult. Here, we present a Peripheral Component Interconnect Express (PCIe)-based highly integrated distributed digital architecture pulsed spectrometer that is implemented with electron and nucleus double resonances and is scalable specifically for broad dynamic nuclear polarization (DNP) enhancement applications, including DNP-magnetic resonance spectroscopy/imaging (DNP-MRS/MRI). The distributed modularized architecture can implement more transceiver channels flexibly to meet a variety of MRS/MRI instrumentation needs. The proposed PCIe bus with high data rates can significantly improve data transmission efficiency and communication reliability and allow precise control of pulse sequences. An external high speed double data rate memory chip is used to store acquired data and pulse sequence elements, which greatly accelerates the execution of the pulse sequence, reduces the TR (time of repetition) interval, and improves the accuracy of TR in imaging sequences. Using clock phase-shift technology, we can produce digital pulses accurately with high timing resolution of 1 ns and narrow widths of 4 ns to control the microwave pulses required by pulsed DNP and ensure overall system synchronization. The proposed spectrometer is proved to be both feasible and reliable by observation of a maximum signal enhancement factor of approximately −170 for {sup 1}H, and a high quality water image was successfully obtained by DNP-enhanced spin-echo {sup 1}H MRI at 0.35 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Combined Release and Radiation Effects Satellite program (CRRES): A unique series of scientific experiments

CRRES is a program to study the space environment which surrounds Earth and the effects of space radiation on modern satellite electronic systems. The satellite will carry an array of active experiments including chemical releases and a complement of sophisticated scientific instruments to accomplish these objectives. Other chemical release active experiments will be performed with suborbital rocket probes. These chemical releases will paint the magnetic and electric fields in Earthspace with clouds of glowing ions. Earthspace will be a laboratory, and the releases will be studied with an extensive network of ground-, aircraft-, and satellite-based diagnostic instruments.

Source record↗

Solar Modulation of {sup 2}H/{sup 1}H and {sup 3}He/{sup 4}He according to Data Obtained in the PAMELA Satellite-Borne Experiment between 2006 and 2014

Preliminary results of measurements of the solar modulation of the isotopic hydrogen and helium content in galactic cosmic rays are presented for the first time. These data were obtained between 2006 and 2014 in the PAMELA international orbital experiment via measuring the time of flight of nuclei in the Pamela scintillation telescope and via analyzing, in the multilayered calorimeter of the PAMELA magnetic spectrometer, ionization losses of nuclei whose rigidity was known from trajectory measurements and which traversed the instrument without undergoing nuclear interactions. The results of these measurements are compared with existing experimental and calculated data, which are quite scanty.

79 ASTRONOMY AND ASTROPHYSICS↗

Tests of Coordinate Transfer from Magnetic to Mechanical Reference for LCLS Undulator Fiducialization

Fiducialization of the LCLS undulators will be based on magnetic measurements by Hall probe. Pointed magnets, proposed by I.Vasserman for quadrupole lens fiducialization will be used as an intermediate reference. A prototype of the pointed magnet fixture has been made and tested. In this note we will describe a procedure for measuring the position of the center of the Hall probe sensitive area with respect to the undulator fiducial marks. The pointed magnet calibration procedure, a two-point algorithm for locating the magnetic center of the fixture, and test results are presented.

43 PARTICLE ACCELERATORS↗

Precisely mapping the magnetic field gradient in vacuum with an atom interferometer

The magnetic field gradient has been measured with an atom interferometer using the magnetic sublevels of {sup 87}Rb atoms. The Doppler-insensitive measurement effectively eliminates the contribution from gravity and background vibration noise, and the differential measurement also can reject some systematic errors. A resolution of 300 pT/mm has been demonstrated with a 90-s integration time and a spatial resolution of 1.4 mm. The gradiometer was then used to measure the magnetic field gradient in an ultrahigh-vacuum environment. The technique will also be very useful to subtract the systematic error arising from the magnetic field inhomogeneity in precision atom-interferometry experiments, such as gravity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An extension of the dual magnetometer method for use on a dual spinning spacecraft

A method of estimating and correcting for the magnetic field of a dual spinning spacecraft has been developed by employing an extension of the dual magnetometer technique. This new method is useful for those situations in which a magnetometer boom of modest length is attached to the spinning part of a large spacecraft. The purpose of using a dual spinning spacecraft is to accommodate two types of instruments: imaging and similar pointed remote sensing systems on the stationary platform, and fields, particles and other in-situ measuring instruments on the spinning portion. The new method assumes that the stationary part of the spacecraft possesses a magnetic field which is represented by a combination of a dipole and a quadrupole field.

Lepping, R. P.↗

The Solar Energetic Particle Event of December 14, 2006

We report on observations of a solar energetic particle event by instruments on five different spacecraft: the Advanced Composition Explorer (ACE), STEREO A and B, WIND, and GOES II. The event began with a class X1.5 .soft x-ray flare in AR930 on December 14 at 22:15 UT. At this time the two STEREO spacecraft were located outside the Earth's magnetosphere and were heading for their first lunar swing-by on December 15. The x-ray event was located on the sun at W46, a longitude which is nominally well-connected magnetically to the Earth. An interplanetary shock, associated with an earlier X3.4 event on December 13 (also from AR930), passed the Earth on December 14 at approx.13:56 (time at ACE). The corresponding magnetic cloud arrived at approx.22 UT on December 14, close to the time of the onset of the particle event associated with the X1.5 flare, and extended until approx.08 UT on December 15. The intensity of approx.14 MeV protons at STEREO A shows three dips by factors of approx.10 or more during the early stages of this event while the spacecraft was within the magnetic cloud. Similar dips are seen for protons to at least 100 MeV. In principle, these dips could have been caused by changes in the magnetic field direction with respect to the particle telescope's field of view while viewing a beamed particle distribution. However, this possibility can be ruled out because the magnetic field at the spacecraft shows no evidence of such directional variations, and similar particle intensity dips were seen by instruments on other spacecraft in the near-Earth solar wind. We shall present evidence that the dips were actually associated with varying magnetic connection to the Sun within the magnetic cloud. These dips were not observed at GOES II, suggesting they were somehow smoothed out by passage into the magnetosphere.

vonRosenvinge, T. T.↗

Design and analysis of embedded I and C for loop-scale magnetically suspended pump - 261

Improving nuclear reactor designs and fuel processing technologies for safer and more efficient operation require the development of new component designs. In particular, many of the advanced reactor design such as the molten salt reactors and high-temperature gas cooled reactors have operating environments beyond the ability of many currently commercially available components. To address this, new cross-cutting technologies need to be developed that will enable the design, fabrication, and reliable operation of new classes of reactor components. The Advanced Sensor Initiative of the Nuclear Energy Enabling Technologies initiative is investigating advanced sensor and control designs that are capable of operating in these extreme environments. Under this initiative Oak Ridge National Laboratory (ORNL) has been developing embedded instrumentation and control for extreme environments. To develop, test, and validate these new sensing and control techniques, ORNL is building a pump testbed with submerged magnetic bearings. The eventual goal is to apply these techniques to a high temperature (700 deg. C) canned rotor pump that utilizes active magnetic bearings to eliminate the need for mechanical bearings and seals. The technologies will benefit the Next Generation Power Plant, Advanced Reactor Concepts, and Small Modular Reactor programs. In this paper we will detail the design and analysis of the embedded I and C testbed with submerged magnetic bearings. Then we will analyze the fluid forces on the shaft. Finally, we will develop the radial and thrust bearing geometries needed to meet the force requirements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Coronal Magnetic Field Configuration on Particle Acceleration and Release during the Ground Level Enhancement Events in Solar Cycle 24

Ground level enhancements (GLEs) are extreme solar energetic particle (SEP) events that are of particular importance in space weather. In solar cycle 24, two GLEs were recorded on 2012 May 17 (GLE 71) and 2017 September 10 (GLE 72), respectively, using a range of advanced modern instruments. Here we conduct a comparative analysis of the two events by focusing on the effects of large-scale magnetic field configuration near active regions on particle acceleration and release. Although the active regions are both located near the western limb, temporal variations of SEP intensities and energy spectra measured in situ display different behaviors at early stages. By combining a potential field model, we find the coronal mass ejection (CME) in GLE 71 originated below the streamer belt, while in GLE 72 it originated near the edge of the streamer belt. We reconstruct the CME shock fronts with an ellipsoid model based on nearly simultaneous coronagraph images from multiple viewpoints and further derive the 3D shock geometry at the GLE onset. The highest-energy particles are primarily accelerated in the shock–streamer interaction regions, i.e., likely at the nose of the shock in GLE 71 and the eastern flank in GLE 72, due to quasi-perpendicular shock geometry and confinement of closed fields. Subsequently, they are released to the field lines connecting to near-Earth spacecraft when the shocks move through the streamer cusp region. This suggests that magnetic structures in the corona, especially shock–streamer interactions, may have played an important role in the acceleration and release of the highest-energy particles in the two events.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass spectrometry and inhomogeneous ion optics

Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.

White, F. A.↗

Plasma Waves Observed in the Cusp Turbulent Boundary Layer: An Analysis of High Time Resolution Wave and Particle Measurements from the Polar Spacecraft

The boundary layer located in the cusp and adjacent to the magnetopause is a region that is quite turbulent and abundant with waves. The Polar spacecraft's orbit and sophisticated instrumentation are ideal for studying this region of space. Our analysis of the waveform data obtained in this turbulent boundary layer shows broadband magnetic noise extending up to a few kilohertz (but less than the electron cyclotron frequency); sinusoidal bursts (a few tenths of a second) of whistler mode waves at around a few tens of hertz, a few hundreds of hertz, and just below the electron cyclotron frequency; and bipolar pulses, interpreted as electron phase-space holes. In addition, bursts of electron cyclotron harmonic waves are occasionally observed with magnetic components. We show evidence of broadband electrostatic bursts covering a range of approx. 3 to approx. 25 kHz (near but less than the plasma frequency) occurring in packets modulated at the frequency of some of the whistler mode waves. On the basis of high time resolution particle data from the Polar HYDRA instrument, we show that these bursts are consistent with generation by the resistive medium instability. The most likely source of the whistler mode waves is the magnetic reconnection site closest to the spacecraft, since the waves are observed propagating both toward and away from the Earth, are bursty, which is often the case with reconnection, and do not fit on the theoretical cold plasma dispersion relation curve.

Pickett, J. S.↗

Auroral, Ionospheric and Ground Magnetic Signatures of Magnetopause Surface Modes

Surface waves on Earth's magnetopause have a controlling effect upon global magnetospheric dynamics. Since spacecraft provide sparse in situ observation points, remote sensing these modes using ground-based instruments in the polar regions is desirable. However, many open conceptual questions on the expected signatures remain. Therefore, we provide predictions of key qualitative features expected in auroral, ionospheric, and ground magnetic observations through both magnetohydrodynamic theory and a global coupled magnetosphere-ionosphere simulation of a magnetopause surface eigenmode. These show monochromatic oscillatory field-aligned currents (FACs), due to both the surface mode and its non-resonant Alfvén coupling, are present throughout the magnetosphere. The currents peak in amplitude at the equatorward edge of the magnetopause boundary layer, not the open-closed boundary as previously thought. They also exhibit slow poleward phase motion rather than being purely evanescent. We suggest the upward FAC perturbations may result in periodic auroral brightenings. In the ionosphere, convection vortices circulate the poleward moving FAC structures. Finally, surface mode signals are predicted in the ground magnetic field, with ionospheric Hall currents rotating perturbations by approximately (but not exactly) 90° compared to the magnetosphere. Thus typical dayside magnetopause surface modes should be strongest in the East-West ground magnetic field component. Overall, all ground-based signatures of the magnetopause surface mode are predicted to have the same frequency across L-shells, amplitudes that maximize near the magnetopause's equatorward edge, and larger latitudinal scales than for field line resonance. Implications in terms of ionospheric Joule heating and geomagnetically induced currents are discussed.

M. O. Archer↗

Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5–10 GHz frequency range

We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme for studying high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes in the magnetization on short time scales and nanometer spatial dimensions is achieved by combining the excitation mechanism with single photon counting electronics that is locked to the synchrotron operation frequency. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with high spatial resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a ∼6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ∼0.1° amplitude at ∼9 GHz in a micrometer-sized cobalt strip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and experimental tests of a novel neutron spin analyzer for wide angle spin echo spectrometers

This paper describes the design and experimental tests of a novel neutron spin analyzer optimized for wide angle spin echo spectrometers. The new design is based on nonremanent magnetic supermirrors, which are magnetized by vertical magnetic fields created by NdFeB high field permanent magnets. The solution presented here gives stable performance at moderate costs in contrast to designs invoking remanent supermirrors. In the experimental part of this paper we demonstrate that the new design performs well in terms of polarization, transmission, and that high quality neutron spin echo spectra can be measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗