Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Single-particle properties of N = 12 to N = 20 silicon isotopes within the dispersive optical model

Experimental neutron and proton single-particle energies in N = 12 to N = 20 silicon isotopes and data on neutron and proton scattering by nuclei of the isotope {sup 28}Si are analyzed on the basis of the dispersive optical model. Good agreement with available experimental data was attained. The occupation probabilities calculated for the single-particle states in question suggest a parallel-type filling of the 1d and 2s{sub 1/2} neutron states in the isotopes {sup 26,28,30,32,34}Si. The single-particle spectra being considered are indicative of the closure of the Z = 14 proton subshell in the isotopes {sup 30,32,34}Si and the N = 20 neutron shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

I. The isotopic Foldy-Wouthuysen representation and chiral symmetry

The paper introduces the isotopic Foldy-Wouthuysen representation. This representation was used to derive equations for massive interacting fermion fields. When the interaction Hamiltonian commutes with the matrix γ{sup 5}, these equations possess chiral invariance irrespective of whether fermions have mass or are massless. The isotopic Foldy-Wouthuysen representation preserves the vector and axial currents irrespective of the fermion mass value. In the Dirac representation, the axial current is preserved only for massless fermions. In the isotopic Foldy-Wouthuysen representation, the ground state of fermions (vacuum) turns out to be degenerate, and therefore there is the possibility of spontaneously breaking parity (P — symmetry). This study considers the example of constructing a chirally symmetric quantum electrodynamics framework in the isotopic Foldy-Wouthuysen representation. A number of physical processes are calculated in the lowest orders of the perturbation theory. Final results of the calculations agree with the results of the standard quantum electrodynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: ${}^{36}\hbox {Ar}$, ${}^{38}\textrm{Ar}$, and ${}^{40}\textrm{Ar}$. We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotope-selective radiography and material assay using high-brilliance, quasi-monochromatic, high-energy photons

We demonstrate the possibility to directly detect microgram amounts of the isotope 7 Li using a quasi-monochromatic high-energy photon beam. The isotope selective detection is based on a witness scatterer absorbing and re-emitting photons via nuclear resonance fluorescence. This enables the detection of isotopes with microgram accuracy at long distances from the actual sample. Further, we demonstrate that the technique can deliver quantitative information without specific knowledge of the photon flux and no spectral capabilities or knowledge of the resonance fluorescence cross section. Detection of low-atomic-weight isotopes screened by heavy shielding is also shown. The techniques described are applicable to all next-generation, ultrahigh brilliance, laser-Compton light sources currently under construction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementing an electronic sideband offset lock for isotope shift spectroscopy in radium

We demonstrate laser frequency stabilization with at least 6 GHz of offset tunability using an in-phase/quadrature (IQ) modulator to generate electronic sidebands (ESB) on a titanium sapphire laser at 714 nm and we apply this technique to perform isotope shift spectroscopy of 226 Ra and 225 Ra. By locking the laser to a single resonance of a high finesse optical cavity and adjusting the lock offset, we determine the frequency difference between the magneto-optical trap (MOT) transitions in the two isotopes to be 2630.0 ± 0.3 MHz, a factor of 29 more precise than the previously available data. Using the known value of the hyperfine splitting of the 3 P 1 level, we calculate the isotope shift for the 1 S 0 to 3 P 1 transition to be 2267.0 ± 2.2 MHz, a factor of 8 more precise than the best available value. Our technique could be applied to countless other atomic systems to provide unprecedented precision in isotope shift spectroscopy and other relative frequency comparisons.

47 OTHER INSTRUMENTATION↗

Production of Cf-252 and other transplutonium isotopes at Oak Ridge National Laboratory

In 1957 Glenn T. Seaborg conceived and advocated for the construction of the High Flux Isotope Reactor (HFIR) and the Transuranium Processing Plant (since then renamed the Radiochemical Engineering Development Center, or REDC) at Oak Ridge National Laboratory. There, heavily shielded hot cells, glove boxes, and laboratories allow recovery of transuranium elements produced in substantial quantities. Seaborg’s vision of HFIR and REDC producing milligram quantities of berkelium, californium, and einsteinium has been fulfilled beginning in 1966 through May 2019 with 78 production campaigns yielding a cumulative totals of 1.2 g of 249 Bk, 10.2 g of 252 Cf, 39 mg of 253 Es, and 15 pg of 257 Fm. Notably, 252 Cf is a neutron source used in many industrial applications including oil exploration; process control systems for the cement industry, coal analysis, and power production; sources to start nuclear reactors and perform nondestructive materials analyses; homeland security and national defense detection devices; and medical research. Isotopes made available through transplutonium production at HFIR/REDC have enabled scientists to study the nuclear properties and reactions, chemical properties, optical properties, and solid-state properties of transplutonium elements. Long-lived isotopes have served as targets in heavy ion accelerators to produce heavier elements leading to the discovery of 104 Rf, 105 Db, 106 Sg, 113 Nh, 114 Fl, 115 Mc, 116 Lv, 117 Ts, and 118 Og. This paper reviews the evolution of the processing flowsheets to produce, separate, and purify transplutonium isotopes, which have evolved over 50 years of operation at HFIR and REDC, and summarizes directions of future work to improve the efficiency of the production operations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Inductively Coupled Plasma/Mass Spectrometric Isotopic Determination of Nuclear Wastes Sources Associated with Hanford Tank Leaks

The subsurface distribution of a nuclear waste tank leak on the U.S. Department of Energy’s Hanford Site was sampled by slant drilling techniques in order to characterize the chemical and radiological characteristics of the leaked material and assess geochemical transport properties of hazardous constituents. Sediment core samples recovered from the borehole were subjected to distilled water and acid leaching procedures with the resulting leachates analyzed for isotopic and chemical signatures. High-sensitivity inductively coupled plasma/mass spectrometry (ICP/MS) techniques were used for determination of isotopic ratios for Cs, I, Mo. Analysis of the isotopic patterns of I and Mo combined with associated chemical data showed evidence for at least two separate intrusions of nuclear waste into the subsurface. Isotopic data for Cs was inconclusive with respect to a source attribution signature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lithium and Lithium Isotopes in Earth’s Surface Cycles

Lithium and its isotopes can provide information on continental silicate weathering, which is the primary natural drawdown process of atmospheric CO 2 and a major control on climate. Lithium isotopes themselves can aid our understanding of weathering, via globally important processes such as clay formation and cation retention. Both these processes occur as part of weathering in modern surface environments, such as rivers, soil pore waters, and groundwaters, but Li isotopes can also be used to track weathering changes across major climate-change events. Lithium isotope evidence from several past climatic warming and cooling episodes shows that weathering processes respond rapidly to changes in temperature, meaning that weathering is capable of bringing climate back under control within a few tens of thousands of years.

54 ENVIRONMENTAL SCIENCES↗

Final Report - Alternative Methods for Producing Medical Isotopes (AMPMI)

This project developed a new concept for medical isotopes production that offers an alternative to reactor-based and accelerator-based technologies and is expected to cost-effectively produce “neutron capture” medical isotopes such as, for example, 177Lu, 125I, 99Tc, and 103Pd, which are used for cancer therapy including prostate cancer. The concept provides for using a neutron flux, like reactor technologies, to make the isotopes of interest. However, the neutron flux is generated by a machine, the Alternative Method for Producing Medical Isotopes (AMPMI) technology, not by a reactor making the technology more applicable.

Eakin, David E↗

The Multi-Isotope Process (MIP) Monitor Project: FY12 Progress and Accomplishments

The Multi-Isotope Process (MIP) Monitor, being developed at Pacific Northwest National Laboratory (PNNL), provides an efficient approach to monitoring the process conditions in reprocessing facilities in support of the goal of "...(minimization of) the risks of nuclear proliferation and terrorism." The MIP Monitor measures distributions of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. These indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to spectral patterns representing "normal" process conditions using multivariate pattern recognition software. The monitor utilizes this multivariate analysis and gamma spectroscopy of reprocessing streams to detect small changes in the gamma spectrum, which may indicate changes in process conditions. Multivariate analysis methods common in chemometrics, such as principal component analysis (PCA) and partial least squares regression (PLS), act as pattern recognition techniques, which can detect small deviations from the expected, nominal condition. By targeting multiple gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, relatively high-resolution gamma detectors that may be easily deployed throughout an existing facility. The automated multivariate analysis can provide a level of data obscurity, giving a built-in information barrier to protect sensitive or proprietary operational data. Proof-of-concept simulations and experiments have been performed in previous years to demonstrate the validity of this tool in a laboratory setting. Development of the MIP Monitor approach continues to evaluate the efficacy of the monitor for automated, real-time or near-real-time application. This report details follow-on research and development efforts sponsored by the U.S. Department of Energy Fuel Cycle Research and Development related to the MIP Monitor for fiscal year 2012 (FY12).

fuel characterization↗

Isotopes and Applications Working Group: Report update October 2013

No significant changes are proposed for the scientific program. The standard mode of operation at FRIB will be to produce a rare isotope beam for a primary user, for example 60 Ca from a 82 Se beam. At the same time, the fragmentation or fission of the production beam will produce up to 1000 other isotopes that could be collected (harvested) and used for other experiments or applications. The potential applications of these harvested isotopes range from the determination of neutron cross sections for homeland security to kinetic studies of radionuclide uptake in biological processes. Longer-lived samples of the unused isotopes could be collected and used in an ion source for accelerated beam experiments at ReA3, ReA12 or other accelerator facilities outside FRIB.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

GADRAS isotope ID user s manual for analysis of gamma-ray measurements and API for Linux and Android .

Isotope identification algorithms that are contained in the Gamma Detector Response and Analysis Software (GADRAS) can be used for real-time stationary measurement and search applications on platforms operating under Linux or Android operating sys-tems. Since the background radiation can vary considerably due to variations in natu-rally-occurring radioactive materials (NORM), spectral algorithms can be substantial-ly more sensitive to threat materials than search algorithms based strictly on count rate. Specific isotopes or interest can be designated for the search algorithm, which permits suppression of alarms for non-threatening sources, such as such as medical radionuclides. The same isotope identification algorithms that are used for search ap-plications can also be used to process static measurements. The isotope identification algorithms follow the same protocols as those used by the Windows version of GADRAS, so files that are created under the Windows interface can be copied direct-ly to processors on fielded sensors. The analysis algorithms contain provisions for gain adjustment and energy lineariza-tion, which enables direct processing of spectra as they are recorded by multichannel analyzers. Gain compensation is performed by utilizing photopeaks in background spectra. Incorporation of this energy calibration tasks into the analysis algorithm also eliminates one of the more difficult challenges associated with development of radia-tion detection equipment.

97 MATHEMATICS AND COMPUTING↗

Understanding H isotope adsorption and absorption of Al-alloys using modeling and experiments (LDRD: #165724)

Current austenitic stainless steel storage reservoirs for hydrogen isotopes (e.g. deuterium and tritium) have performance and operational life-limiting interactions (e.g. embrittlement) with H-isotopes. Aluminum alloys (e.g.AA2219), alternatively, have very low H-isotope solubilities, suggesting high resistance towards aging vulnerabilities. This report summarizes the work performed during the life of the Lab Directed Research and Development in the Nuclear Weapons investment area (165724), and provides invaluable modeling and experimental insights into the interactions of H isotopes with surfaces and bulk AlCu-alloys. The modeling work establishes and builds a multi-scale framework which includes: a density functional theory informed bond-order potential for classical molecular dynamics (MD), and subsequent use of MD simulations to inform defect level dislocation dynamics models. Furthermore, low energy ion scattering and thermal desorption spectroscopy experiments are performed to validate these models and add greater physical understanding to them.

36 MATERIALS SCIENCE↗

Collaborative Proposal. Development of an Isotope-Enabled CESM for Testing Abrupt Climate Changes

We have made significant landmarks in our proposed work in the last 4 years (3 years plus 1 year of no cost extension). We have developed the simulation capability of the major isotopes in CESM. In particular, we have completed the implementation of the stable water isotopes (δ 18 O, δD) into the components for the atmosphere, ocean, land surface, runoff transport, sea ice, and coupler. In addition, the carbon isotopes (abiotic and biotic radiocarbon, δ 13 C) have been implemented into the CESM ocean and land models, and long spinup simulations have been completed (Jahn et al., 2015). Furthermore, we have added abiotic Neodymium to the CESM ocean model as a tracer of ocean circulation, also measured by the proxy data community. Fullycoupled simulations with the stable water isotopes and ocean radiocarbon are currently being run for the preindustrial and also the Last Glacial Maximum. We have secured 19 million core-hours on the NWSC Yellowstone supercomputer for 12 months. Together with some CESM Paleoclimate Working Group CSL Yellowstone core hours, we are guaranteed sufficient computing for the spin-up experiments and deglaciation simulations for 21 to 15ka.

54 ENVIRONMENTAL SCIENCES↗

A Hydrogen and He Isotope Nanoprobe

Materials that incorporate hydrogen and helium isotopes are of great interest at Sandia and throughout the NNSA and DOE. The Ion Beam Lab at SNL-NM has invented techniques using micron to mm-size MeV ion beams to recoil these light isotopes (Elastic Recoil Detection or ERD) that can very accurately make such measurements. However, there are many measurements that would benefit NW and DOE that require much better resolution, such as the distribution of H isotopes (and 3He) in individual grains of materials relevant to TPBARs, H and He-embrittlement of weapon components important to Tritium Sustainment Programs, issues with GTSs, batteries… Higher resolution would also benefit the field of materials science in general. To address these and many other issues, nm-scale lateral resolution is required. This LDRD demonstrated that neutral H atoms could be recoiled through a thin film by 70 keV electrons and detected with a Channeltron electron multiplier (CEM). The electrons were steered away from the CEM by strong permanent magnets. This proved the feasibility that the high energy electrons from a transmissionelectron- microscope-TEM can potentially be used to recoil and subsequently detect (e-ERD), quantify and map the concentration of H and He isotopes with nm resolution. This discovery could lead to a TEM-based H/He-isotope nanoprobe with 1000x higher resolution than currently available.

36 MATERIALS SCIENCE↗

Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled High-Resolution Gamma Spectrometry Systems Final Report

Under a 2006 agreement between the Department of Energy (DOE) of the United States of America and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) of France, the National Nuclear Security Administration (NNSA) within DOE and IRSN initiated a collaboration to improve isotopic identification and analysis of nuclear material [i.e., plutonium (Pu) and uranium (U)]. The specific aim of the collaborative project was to develop new versions of two types of isotopic identification and analysis software: (1) the fixed-energy response-function analysis for multiple energies (FRAM) codes and (2) multi-group analysis (MGA) codes. The project is entitled Action Sheet 4 – Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled, High-Resolution Gamma Spectrometry Systems (Action Sheet 4). FRAM and MGA/U235HI are software codes used to analyze isotopic ratios of U and Pu. FRAM is an application that uses parameter sets for the analysis of U or Pu. MGA and U235HI are two separate applications that analyze Pu or U, respectively. They have traditionally been used by safeguards practitioners to analyze gamma spectra acquired with high-resolution gamma spectrometry (HRGS) systems that are cooled by liquid nitrogen. However, it was discovered that these analysis programs were not as accurate when used on spectra acquired with a newer generation of more portable, electrically cooled HRGS (ECHRGS) systems. In response to this need, DOE/NNSA and IRSN collaborated to update the FRAM and U235HI codes to improve their performance with newer ECHRGS systems. Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) performed this work for DOE/NNSA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Collaborative Project: Development of an Isotope-Enabled CESM for Testing Abrupt Climate Changes

One of the most important validations for a state-of-art Earth System Model (ESM) with respect to climate changes is the simulation of the climate evolution and abrupt climate change events in the Earth’s history of the last 21,000 years. However, one great challenge for model validation is that ESMs usually do not directly simulate geochemical variables that can be compared directly with past proxy records. In this proposal, we have met this challenge by developing the simulation capability of major isotopes in a state-of-art ESM, the Community Earth System Model (CESM), enabling us to make direct model-data comparison by comparing the model directly against proxy climate records. Our isotope-enabled ESM incorporates the capability of simulating key isotopes and geotracers, notably δ 18 O, δD, δ 14 C, and δ 13 C, Nd and Pa/Th. The isotope-enabled ESM have been used to perform some simulations for the last 21000 years. The direct comparison of these simulations with proxy records has shed light on the mechanisms of important climate change events.

54 ENVIRONMENTAL SCIENCES↗

(U) Second Derivative of an (α,n) Neutron Source with Respect to Constituent Isotope Densities

We are deriving adjoint-based second-order sensitivities of a response in transport theory. Neutron problems need the second-order sensitivity of the inhomogeneous source with respect to the constituent isotope densities. We have previously derived and verified the first-order sensitivity of an (α,n) neutron source with respect to isotope densities and the subsequent first-order sensitivity of a leakage response. In this memo, we derive and verify the second-order sensitivity of an (α,n) neutron source with respect to constituent isotope densities. We show that the second-order sensitivity of a spontaneous-fission source with respect to constituent isotope densities is zero. The propagation of these second-order sensitivities to the second-order sensitivity of a response awaits the completion of the coding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗