Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverse Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Information-theoretic discrepancy based iterative reconstructions (IDIR) for polychromatic x-ray tomography

Purpose: X-ray photons generated from a typical x-ray source for clinical applications exhibit a broad range of wavelengths, and the interactions between individual particles and biological substances depend on particles' energy levels. Most existing reconstruction methods for transmission tomography, however, neglect this polychromatic nature of measurements and rely on the monochromatic approximation. In this study, we developed a new family of iterative methods that incorporates the exact polychromatic model into tomographic image recovery, which improves the accuracy and quality of reconstruction.Methods: The generalized information-theoretic discrepancy (GID) was employed as a new metric for quantifying the distance between the measured and synthetic data. By using special features of the GID, the objective function for polychromatic reconstruction which contains a double integral over the wavelength and the trajectory of incident x-rays was simplified to a paraboloidal form without using the monochromatic approximation. More specifically, the original GID was replaced with a surrogate function with two auxiliary, energy-dependent variables. Subsequently, the alternating minimization technique was applied to solve the double minimization problem. Based on the optimization transfer principle, the objective function was further simplified to the paraboloidal equation, which leads to a closed-form update formula. Numerical experiments on the beam-hardening correction and material-selective reconstruction were conducted to compare and assess the performance of conventional methods and the proposed algorithms.Results: The authors found that the GID determines the distance between its two arguments in a flexible manner. In this study, three groups of GIDs with distinct data representations were considered. The authors demonstrated that one type of GIDs that comprises “raw” data can be viewed as an extension of existing statistical reconstructions; under a particular condition, the GID is equivalent to the Poisson log-likelihood function. The newly proposed GIDs of the other two categories consist of log-transformed measurements, which have the advantage of imposing linearized penalties over multiple discrepancies. For all proposed variants of the GID, the aforementioned strategy was used to obtain a closed-form update equation. Even though it is based on the exact polychromatic model, the derived algorithm bears a structural resemblance to conventional methods based on the monochromatic approximation. The authors named the proposed approach as information-theoretic discrepancy based iterative reconstructions (IDIR). In numerical experiments, IDIR with raw data converged faster than previously known statistical reconstruction methods. IDIR with log-transformed data exhibited superior reconstruction quality and faster convergence speed compared with conventional methods and their variants.Conclusions: The authors' new framework for tomographic reconstruction allows iterative inversion of the polychromatic data model. The primary departure from the traditional iterative reconstruction was the employment of the GID as a new metric for quantifying the inconsistency between the measured and synthetic data. The proposed methods outperformed not only conventional methods based on the monochromatic approximation but also those based on the polychromatic model. The authors have observed that the GID is a very flexible means to design an objective function for iterative reconstructions. Hence, the authors expect that the proposed IDIR framework will also be applicable to other challenging tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures

Purpose: In this report, the authors introduce the general concept of the completeness map, as a means to evaluate the completeness of data acquired by a given CT system design (architecture and scan mode). They illustrate the utility of completeness map by applying the completeness map concept to a number of candidate CT system designs, as part of a study to advance the state-of-the-art in cardiac CT. Methods: In order to optimally reconstruct a point within a volume of interest (VOI), the Radon transform on all possible planes through that point should be measured. The authors quantified the extent to which this ideal condition is satisfied for the entire image volume. They first determined a Radon completeness number for each point in the VOI, as the percentage of possible planes that is actually measured. A completeness map is then defined as a 3D matrix of the completeness numbers for the entire VOI. The authors proposed algorithms to analyze the projection datasets in Radon space and compute the completeness number for a fixed point and apply these algorithms to various architectures and scan modes that they are evaluating. In this report, the authors consider four selected candidate architectures, operating with different scan modes, for a total of five system design alternatives. Each of these alternatives is evaluated using completeness map. Results: If the detector size and cone angle are large enough to cover the entire cardiac VOI, a single-source circular scan can have {>=}99% completeness over the entire VOI. However, only the central z-slice can be exactly reconstructed, which corresponds to 100% completeness. For a typical single-source architecture, if the detector is limited to an axial dimension of 40 mm, a helical scan needs about five rotations to form an exact reconstruction region covering the cardiac VOI, while a triple-source helical scan only requires two rotations, leading to a 2.5x improvement in temporal resolution. If the source and detector of an inverse-geometry (IGCT) system have the same axial extent, and the spacing of source points in the axial and transaxial directions is sufficiently small, the IGCT can also form an exact reconstruction region for the cardiac VOI. If the VOI can be covered by the x-ray beam in any view, a composite-circling scan can generate an exact reconstruction region covering the VOI. Conclusions: The completeness map evaluation provides useful information for selecting the next-generation cardiac CT system design. The proposed completeness map method provides a practical tool for analyzing complex scanning trajectories, where the theoretical image quality for some complex system designs is impossible to predict, without yet-undeveloped reconstruction algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ground Penetrating Radar in Hydrogeophysics

To meet the needs of a growing population and to provide us with a higher quality of life, increasing pressures are being placed on our environment through the development of agriculture, industry, and infrastructures. Soil erosion, groundwater depletion, salinization, and pollution have been recognized for decades as major threats to ecosystems and human health. More recently, the progressive substitution of fossil fuels by biofuels for energy production and climate change have been recognized as potential threats to our water resources and sustained agricultural productivity. The vadose zone mediates many of the processes that govern water resources and quality, such as the partition of precipitation into infiltration and runoff , groundwater recharge, contaminant transport, plant growth, evaporation, and energy exchanges between the Earth's surface and its atmosphere. It also determines soil organic carbon sequestration and carbon-cycle feedbacks, which could substantially impact climate change. The vadose zone's inherent spatial variability and inaccessibility precludes direct observation of the important subsurface processes. In a societal context where the development of sustainable and optimal environmental management strategies has become a priority, there is a strong prerequisite for the development of noninvasive characterization and monitoring techniques of the vadose zone. In particular, hydrogeophysical approaches applied at relevant scales are required to appraise dynamic subsurface phenomena and to develop optimal sustainability, exploitation, and remediation strategies. Among existing geophysical techniques, ground penetrating radar (GPR) technology is of particular interest for providing high-resolution subsurface images and specifically addressing water-related questions. Ground penetrating radar is based on the transmission and reception of VHF-UHF (30-3000 MHz) electromagnetic waves into the ground, whose propagation is determined by the soil electromagnetic properties and their spatial distribution. As the dielectric permittivity of water overwhelms the permittivity of other soil components, the presence of water in the soil principally governs GPR wave propagation. Therefore, GPR-derived dielectric permittivity is usually used as surrogate measure for soil water content. In the areas of unsaturated zone hydrology and water resources, GPR has been used to identify soil stratigraphy, to locate water tables, to follow wetting front movement, to estimate soil water content, to assist in subsurface hydraulic parameter identification, to assess soil salinity, and to support the monitoring of contaminants. The purpose of this special section of the Vadose Zone Journal is to present recent research advances and applications of GPR in hydrogeophysics, with a particular emphasis on vadose zone investigations. This special section includes contributions presented at the European Geosciences Union General Assembly 2006 (EGU 2006, Vienna, Austria) and the 11th International Conference on Ground Penetrating Radar (GPR 2006, Columbus, OH). The studies presented here deal with a wide range of surface and borehole GPR applications, including GPR sensitivity to contaminant plumes, new methods for soil water content determination, three-dimensional imaging of the subsurface, time-lapse monitoring of hydrodynamic events and inversion techniques for soil hydraulic properties estimation, and joint interpretation of GPR and electric resistivity tomography (ERT) data.

54 ENVIRONMENTAL SCIENCES↗

Performance of a High-Concentration Erbium-Doped Fiber Amplifier with 100 nm Amplification Bandwidth

Increasing demand for higher bandwidth has driven the need for higher Wavelength Division Multiplexing (WDM) channels. One of the requirements to achieve this is a broadband amplifier. This paper reports the performance of a broadband, compact, high-concentration and silica-based erbium-doped fiber amplifier. The amplifier optimized to a 2.15 m long erbium-doped fiber with erbium ion concentration of 2000 ppm. The gain spectrum of the amplifier has a measured amplification bandwidth of 100 nm using a 980 nm laser diode with power of 150 mW. This silica-based EDFA shows lower noise figure, higher gain and wider bandwidth in shorter wavelengths compared to Bismuth-based EDFA with higher erbium ion concentration of 3250 ppm at equivalent EDF length. The silica-based EDF shows peak gain at 22 dB and amplification bandwidth between 1520 nm and 1620 nm. The lowest noise figure is 5 dB. The gain is further improved with the implementation of enhanced EDFA configurations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unveiling the Role of In Situ Al 2 O 3 Passivation in Molecular-Ink-Processed CuIn(S,Se) 2 Photovoltaics

Here, we report on the optimization of in situ passivation of ink-based CuIn(S,Se) 2 thin-film solar cells via controlled incorporation of Al 2 O 3 in CuIn(S,Se) 2 films by the addition of Al(NO 3 ) 3 to the molecular ink precursor. For this purpose, the Al/(Al + In) (AAI) metal ratio was varied from 0.05 to 0.30. We observe that the efficiency of the cells made of Al 2 O 3 -incorporated CuIn(S,Se) 2 is consistently higher than those without Al 2 O 3 , especially due to an improvement in open-circuit voltage (V OC ) and fill factor (FF), for all tested AAI ratios. With an AAI of 0.05, a maximum efficiency of 11.2% and an average efficiency of 8.5% (measured across 18 cells) was achieved, compared to 8.5% maximum efficiency and 6.5% average efficiency for Al-free CuIn(S,Se) 2 . Furthermore, we find that cells made of Al 2 O 3 -incorporated CuIn(S,Se) 2 with an AAI of 0.2 show a narrow distribution in the photovoltaic performance, indicating higher reproducibility and higher FF. Energy-dispersive X-ray spectroscopy shows that, at AAI = 0.2, Al 2 O 3 is distributed more homogeneously at the surface of the Al 2 O 3 -incorporated CISSe. Capacitance-voltage measurements reveal a reduced defect density by incorporation of Al 2 O 3 , which could be partly responsible for the higher V OC . Furthermore, using detailed surface analysis with various X-ray and electron spectroscopy methods, we derive chemical and electronic structure information from the surface. With ultraviolet photoelectron (UPS) and inverse photoemission spectroscopies (IPES), the electronic band gap of the CuIn(S,Se) 2 thin-film surface is found to increase from 1.22 to 1.88 eV (+-0.12 eV) with Al 2 O 3 incorporation. This is accompanied by a clear reduction of the conduction band spike at the CdS/CISSe interface due to Al 2 O 3 addition, as derived by both UPS and IPES as well as temperature-dependent V OC measurements.

14 SOLAR ENERGY↗

Nonnegative tensor factorization for contaminant source identification

Unsupervised Machine Learning (ML) is becoming increasingly popular for solving various types of data analytics problems including feature extraction, blind source separation, exploratory analyses, model diagnostics, etc. In this work, we have developed a new unsupervised ML method based on Nonnegative Tensor Factorization (NTF) for identification of the original groundwater types (including contaminant sources) present in geochemical mixtures observed in an aquifer. Frequently, groundwater types with different geochemical signatures are related to different background and/or contamination sources. The characterization of groundwater mixing processes is a challenging but very important task critical for any environmental management project aiming to characterize the fate and transport of contaminants in the subsurface and perform contaminant remediation. This task typically requires solving complex inverse models representing groundwater flow and geochemical transport in the aquifer, where the inverse analysis accounts for available site data. Usually, the model is calibrated against the available data characterizing the spatial and temporal distribution of the observed geochemical types. Numerous different geochemical constituents and processes may need to be simulated in these models which further complicates the analyses. Additionally, the application of inverse methods may introduce biases in the analyses through the assumptions made in the model development process. Here, we substitute the model inversion with unsupervised ML analysis. The ML analysis does not make any assumptions about underlying physical and geochemical processes occurring in the aquifer. Our ML methodology, called NTFk, is capable of identifying (1) the unknown number of groundwater types (contaminant sources) present in the aquifer, (2) the original geochemical concentrations (signatures) of these groundwater types and (3) spatial and temporal dynamics in the mixing of these groundwater types. These results are obtained only from the measured geochemical data without any additional site information. In general, the NTFk methodology allows for interpretation of large high-dimensional datasets representing diverse spatial and temporal components such as state variables and velocities. NTFk has been tested on synthetic and real-world site three-dimensional datasets. Finally, the NTFk algorithm is designed to work with geochemical data represented in the form of concentrations, ratios (of two constituents; for example, isotope ratios), and delta notations (standard normalized stable isotope ratios).

58 GEOSCIENCES↗

Short-term variation in leaf-level water use efficiency in a tropical forest

Here we report the representation of stomatal regulation of transpiration and CO 2 assimilation is key to forecasting terrestrial ecosystem responses to global change. Given its importance in determining the relationship between forest productivity and climate, accurate and mechanistic model representation of the relationship between stomatal conductance (g s ) and assimilation is crucial. We assess possible physiological and mechanistic controls on the estimation of the g 1 (stomatal slope, inversely proportional to water use efficiency) and g 0 (stomatal intercept) parameters, using diurnal gas exchange surveys and leaf level response curves of six tropical broadleaf evergreen tree species. g 1 estimated from ex-situ response curves averaged 50% less than g 1 estimated from survey data. While g 0 and g 1 varied between leaves of different phenological stages, the trend was not consistent among species. We identified a diurnal trend associated with g 1 and g 0 that significantly improved model projections of diurnal trends in transpiration. The accuracy of modelled g s can be improved by accounting for variation in stomatal behavior across diurnal periods, and between measurement approaches, rather than focusing on phenological variation in stomatal behavior. Additional investigation into the primary mechanisms responsible for diurnal variation in g 1 will be required to account for this phenomena in land surface models.

54 ENVIRONMENTAL SCIENCES↗

Three-dimensional NDE of VHTR core components via simulation-based testing. Final report

A next generation, simulation-driven-and-enabled testing platform is developed for the 3D detection and characterization of defects and damage in nuclear graphite and composite structures in Very High Temperature Reactors (VHTRs). The proposed work addresses the critical need for the development of high-fidelity Non-Destructive Examination (NDE) technologies for as-manufactured and replaceable in-service VHTR components. Centered around the novel use of elastic (sonic and ultrasonic) waves, this project deploys a robust, non-iterative inverse solution for the 3D defect reconstruction together with a non-contact, laser-based approach to the measurement of experimental waveforms in VHTR core components. In particular, this research (1) deploys three-dimensional Scanning Laser Doppler Vibrometry (3D SLDV) as a means to accurately and remotely measure 3D displacement waveforms over the accessible surface of a VHTR core component excited by mechanical vibratory source; (2) implements a powerful new inverse technique, based on the concept of Topological Sensitivity (TS), for non-iterative elastic waveform tomography of internal defects - that permits robust 3D detection, reconstruction and characterization of discrete damage (e.g. holes and fractures) in nuclear graphite from limited-aperture NDE measurements; (3) implements state-of-the art computational (finite element) model that caters for accurately simulating elastic wave propagation in 3D blocks of nuclear graphite; (4) integrates the SLDV testing methodology with the TS imaging algorithm into a non-contact, high-fidelity NDE platform for the 3D reconstruction and characterization of defects and damage in VHTR core components; and (5) applies the proposed methodology to VHTR core component samples (both two- and three-dimensional) with a priori induced, discrete damage in the form of holes and fractures. Overall, the newly established SLDV-TS testing platform represents a next-generation NDE tool that surpasses all existing techniques for the 3D ultrasonic imaging of material damage from non-contact, limited-aperture waveform measurements. Outlook. The next stage in the development of this technology includes items such as (a) non-contact generation of mechanical vibrations in VHTR components via thermal expansion created by high-intensity laser; (b) development and incorporation of Synthetic Aperture Focusing Technique (SAFT) for elevating the accuracy of 3D imaging in highly noisy environments with minimal accessible surface; (c) further analytical and computational developments to facilitate the reconstruction of diffuse damage (e.g. microcracks) in nuclear graphite as they lead to the dispersion of elastic waves, (d) concept of model updating for accurate tracking of the evolution of material damage via periodic inspections; (d) adoption of the Bayesian framework to obtain information on the certainty of obtained images; and (e) optimization of the computational scheme toward real-time, model-based imaging of damage in VHTR core components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An ant-nest-like cathode substrate for lithium-sulfur batteries with practical cell fabrication parameters

We report that electrochemical performances of lithium-sulfur batteries have received much progress in recent years. However, their practical deployment encounters challenges with respect to optimizing the cell-fabrication parameters (e.g., amounts of the active material and electrolyte). We present here an “ant-nest-like” cathode substrate with unique architecture to synchronously attain high electrochemical performance and necessary cell-fabrication parameters. The cells with a high sulfur loading (11.5 mg cm -2 ), a high sulfur content (75 wt.%), and a low electrolyte/sulfur ratio (9 μL mg -1 ) display a high areal capacity and energy density of, respectively, 7 mA h cm -2 and 14 mW h cm -2 with a capacity retention of 70% after 150 cycles. Moreover, the cells exhibit a low self-discharge behavior with a low self-discharge constant of 0.0013 per day and a long rest period of one month. Lastly, these dynamic and static electrochemical stabilities are attributed to the ant-nest-like structure and low surface area of the cathode substrate that allows, respectively, the accommodation and encapsulation of a high amount of active material and reduces the consumption of electrolyte.

25 ENERGY STORAGE↗

Comparison of Oncentra® Brachy IPSA and graphical optimisation techniques: a case study of HDR brachytherapy head and neck and prostate plans

There are a number of different dwell positions and time optimisation options available in the Oncentra® Brachy (Elekta Brachytherapy Solutions, Veenendaal, The Netherlands) brachytherapy treatment planning system. The purpose of this case study was to compare graphical (GRO) and inverse planning by simulated annealing (IPSA) optimisation techniques for interstitial head and neck (HN) and prostate plans considering dosimetry, modelled radiobiology outcome and planning time. Four retrospective brachytherapy patients were chosen for this study, two recurrent HN and two prostatic boosts. Manual GRO and IPSA plans were generated for each patient. Plans were compared using dose–volume histograms (DVH) and dose coverage metrics including; conformity index (CI), homogeneity index (HI) and conformity number (CN). Logit and relative seriality models were used to calculate tumour control probability (TCP) and normal tissue complication probability (NTCP). Approximate planning time was also recorded. There was no significant difference between GRO and IPSA in terms of dose metrics with mean CI of 1.30 and 1.57 (P > 0.05) respectively. IPSA achieved an average HN TCP of 0.32 versus 0.12 for GRO while for prostate there was no significant difference. Mean GRO planning times were greater than 75 min while average IPSA planning times were less than 10 min. Planning times for IPSA were greatly reduced compared to GRO and plans were dosimetrically similar. For this reason, IPSA makes for a useful planning tool in HN and prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian Approach for In-Situ Stress Prediction and Uncertainty Quantification for Subsurface Engineering

Many subsurface engineering applications require accurate knowledge of the in-situ state of stress for their safe design and operation. Existing methods to meet this need primarily include field measurements for estimating one or more of the principal stresses from a borehole, or optimization methods for constructing a 3D geomechanical model in terms of geophysical measurements. These methods, however, often contain considerable uncertainty in estimating the state of stress. Here, in this paper, we build on a Bayesian approach to quantify uncertainty in stress estimations for subsurface engineering applications. This approach can provide an estimate of the 3D distribution of stress throughout the volume of interest and provide an estimate of the uncertainty arising from the stress measurement, the rheology parameters, and a paucity of measurements. The value of this approach is demonstrated using stress measurements from the In Salah carbon storage site, which was one of the world’s first industrial carbon capture and storage projects. This demonstration shows the application of this Bayesian approach for estimating the initial state of stress for In Salah and quantifying the uncertainty in the estimated stress. Also, an assessment of a maximum injection pressure to prevent geomechanical risks from CO 2 injection pressures is provided in terms of the probability distribution of the minimum principal stress quantified by the approach. With the In Salah case study, this paper demonstrates that using the Bayesian approach can provide additional insights for site explorations and/or project operations to make informed-site decisions for subsurface engineering applications.

58 GEOSCIENCES↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Gulf of Mexico miocene CO₂ site characterization mega transect

This project characterized the Miocene-age sub-seafloor stratigraphy in the near-offshore portion of the Gulf of Mexico adjacent to the Texas coast. The large number of industrial sources of carbon dioxide (CO₂) in coastal counties and the high density of onshore urbanization and environmentally sensitive areas make this offshore region extremely attractive for long-term storage of carbon dioxide emissions from industrial sources (CCS). The study leverages dense existing geologic data from decades of hydrocarbon exploration in and around the study area to characterize the regional geology for suitability and storage capacity. Primary products of the study include: regional static storage capacity estimates, sequestration “leads” and prospects with associated dynamic capacity estimates, experimental studies of CO₂-brine-rock interaction, best practices for site characterization, a large-format ‘Atlas’ of sequestration for the study area, and characterization of potential fluid migration pathways for reducing storage risks utilizing novel high-resolution 3D (HR3D) seismic surveys. In addition, three subcontracted studies address source-to-sink matching optimization, offshore well bore management and environmental aspects. The various geologic data and interpretations are integrated and summarized in a series of cross-sections and maps, which represent a primary resource for any near-term commercial deployment of CCS in the area. The regional study characterized and mapped important geologic features (e.g., Clemente-Tomas fault zone, the regionally extensive Marginulina A and Amphistegina B confining systems, etc.) that provided an important context for regional static capacity estimates and specific sequestration prospects of the study. A static capacity estimate of the majority of the Study area (14,467 mi 2 ) was estimated at 86 metric Gigatonnes. While local capacity estimates are likely to be lower due to reservoir-scale characteristics, the offshore Miocene interval is a storage resource of National interest for providing CO₂ storage as an atmospheric emissions abatement strategy. The natural petroleum system was used as an analog to infer seal quality and predict possible migration pathways of fluids in an engineered system of anthropogenic CO₂ injection and storage. The regional structural features (e.g., Clemente-Tomas fault zone) that exert primary control on the trapping and distribution of Miocene hydrocarbons are expected to perform similarly for CCS. Industrial-scale CCS will require storage capacity utilizing well-documented Miocene hydrocarbon (dominantly depleted gas) fields and their larger structural closures, as well as barren (unproductive, brine-filled) closures. No assessment was made of potential for CO₂ utilization for enhanced oil and gas recovery. The use of 3D numerical fluid flow simulations have been used in the study to greatly assist in characterizing the potential storage capacity of a specific reservoir. Due to the complexity of geologic systems (stratigraphic heterogeneity) and inherent limitations on producing a 3D geologic model, these simulations are typically simplified scenarios that explore the influence of model property variability (sensitivity study). A specific site offshore San Luis Pass (southern Galveston Island) was undertaken successfully, indicating stacked storage potential. Downscaling regional capacity estimates to the local scale (and the inverse) has proven challenging, and remains an outstanding gap in capacity assessments. In order to characterize regional seal performance and identify potential brine and CO₂ leakage pathways, results from three high-resolution 3D (HR3D) seismic datasets acquired by the study using novel HR3D (P-Cable) acquisition system showed steady and significant improvements in data quality because of improved acquisition and processing technique. Finely detailed faults and stratigraphy in the shallowest 1000 milliseconds (~800 m) of data allowed for the identification and mapping of unconformable surfaces including what is probably a surface associated with the last Pleistocene glacial lowstand. The identification of a previously unrecognized (in commercial seismic data) gas chimney that was clearly defined in the 2013 HR3D survey, indicates that HR3D surveys may be useful as both a characterization tool for the overburden of a potential carbon sequestration site and as an additional monitoring tool for future engineered injection sites. Geochemical modeling indicated that injection of CO₂ would result in minor dissolution of calcite, K-feldspar and albite. In addition, modeling of typical brines in Miocene age rocks indicate that approximately 5% of injection capacity would result from CO₂ dissolution into the brine. After extensive searches, no rock samples of the Marginulina A and Amphistegina B seals (“caprocks”) were obtained, but analyses of available core samples of other Miocene age mudrocks (seals or caprocks) indicate that they have sealing ability sufficient for potential CO 2 storage in underlying sandstone units.

01 COAL, LIGNITE, AND PEAT↗

Boosting Noise2Inverse via enhanced model selection for denoising computed tomography data

Synchrotron-based x-ray tomographic imaging enables the examination of the internal structure of materials at high spatial and temporal resolution. Experimental constraints can impose dose and time limits on the measurements, introducing a higher level of noise and artifacts in the reconstructed images. Deep learning has emerged as a powerful tool to remove noise from reconstructed images. Recently, the Noise2Inverse method was designed specifically for denoising reconstructed images without requiring paired noisy and clean images. This method creates multiple statistically independent reconstructions used to pair the data in which training involves transforming one reconstruction into the other, and vice versa. Originally designed to be used after a fixed number of epochs, we see in practice that this approach may not produce the optimal model and may unnecessarily waste computational resources. Therefore, we propose an alternative method of identifying the best model during training that aligns with the Noise2Inverse method. During validation, we compare the model output of the multiple reconstructions among each other. We hypothesize that the best model is the one that produces images with the highest similarity, implying a convergence in the predicted material properties and absorption values. To compare model outputs, we consider the absolute error, square error, structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and cosine similarity. We evaluate our method on two simulated tomography datasets and two, real-world, low-contrast, high-energy x-ray tomography datasets. We show our approach is more effective at determining the best model, up to an increase of 12.50% and 12.53% in SSIM and PSNR, respectively, while only requiring a fifth of the training time compared to the original approach.

CT↗

Characterization of XR-RV3 GafChromic{sup ®} films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

Purpose: To investigate the optimal use of XR-RV3 GafChromic{sup ®} films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. Methods: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. Results: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. Conclusions: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

60 APPLIED LIFE SCIENCES↗

Optimum power analysis of a self-reactive wave energy point absorber with mechanically-driven power take-offs

This paper studies a self-reactive ocean wave energy converter (WEC) where energy is absorbed through the relative motion between a floating buoy on the ocean surface and a submerged body. Two types of direct-drive power take off (PTO) systems are examined. One adopts a ball screw system in inverse driving mode with mechanical motion rectifier (MMR) that converts the oscillating bi-directional input heave motion into unidirectional rotation to drive an electromagnetic generator, and another one uses a ball screw system to directly drive the generator (called non-MMR). Dynamic models for both types of PTOs are established and integrated with the overall WEC system model in both the time and frequency domains. Numerical simulation is used to investigate the dynamic performance of both PTOs. The influences of the PTO inerter, which is from the rotational inertia of the flywheel and generator, and the WEC drag damping coefficient are discussed and explored. The analytical closed-form solution for the optimum condition of the non-MMR system is derived based on the criterion of maximum power absorption, and numerical simulation yields the optimum condition for the MMR system. Overall, the results under regular and irregular waves show that the PTO inerter in the MMR system can improve the power absorption for small wave periods and maintain the same performance for large wave periods. The PTO inerter in the non-MMR system shifts the peak frequency. The WEC drag damping negatively influences the power absorption in both PTO systems, especially at large wave periods.

16 TIDAL AND WAVE POWER↗

Crustal and uppermost mantle structure in the Middle East: assessing constraints provided by jointly modelling Ps and Sp receiver functions and Rayleigh wave group velocity dispersion curves

Seismic velocity models are found, along with uncertainty estimates, for 11 sites in the Middle East by jointly modelling Ps and Sp receiver functions and surface (Rayleigh) wave group velocity dispersion. The approach performs a search for models that satisfy goodness-of-fit criteria guided by a variant of simulated annealing and uses statistical tools to assess these products of searches. These tools, a parameter correlation matrix and marginal posterior probability density (PPD) function, allow us to evaluate quantitatively the constraints that each data type imposes on model parameters and to identify portions of each model that are well-constrained relative to other portions. This joint modelling technique, which we call ‘multi-objective optimization for seismology’, does not require a good starting solution, although such a model can be incorporated easily, if available, and can reduce the computation time significantly. Applying the process described above to broadband seismic data reveals that crustal thickness varies from 15 km beneath Djibouti (station ATD) to 45 km beneath Saudi Arabia (station RAYN). A pronounced low velocity zone for both Vp and Vs is present at a depth of ~12 km beneath station KIV located in northern part of greater Caucasus, which may be due to the presence of a relatively young volcano. Similarly, we also noticed a 6-km-thick low velocity zone for Vp beginning at 20 km depth beneath seismic station AGIN, on the Anatolian plateau, while positive velocity gradients prevail elsewhere in eastern Turkey. Beneath station CSS, located in Cyprus, an anomalously slow layer is found in the uppermost mantle, which may indicate the presence of altered lithospheric material. Crustal P- and S-wave velocities beneath station D2, located in the northeastern portion of central Zagros, range between 5.2–6.2 and 3.2–3.8 km s -1 , respectively. Finally, in Oman, we find a Moho depth of 34.0 ± 1.0 km and 25.0 ± 1.0 to 30.0 ± 1.0 km beneath stations S02 and S04, respectively.

58 GEOSCIENCES↗

Effect of beam number on organ-at-risk sparing in dynamic multileaf collimator delivery of intensity modulated radiation therapy

Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation than they would with an ideal MLC that could generate the desired fluence pattern. Previous work by others has found that the discrepancy between desired and actual fluence patterns produced by an MLC increases rapidly with increasing complexity of the desired fluence map. In addition to the complexity of individual fluence maps, other parameters can contribute to the overall complexity of a treatment plan, most notably the number of beams. In this work, we investigate the effect of beam number on critical structure sparing for dynamic MLC delivered intensity modulated radiation therapy. Six cases from each of two challenging clinical sites, previously irradiated head and neck and paraspinal metastasis, were planned with the goal of minimizing the spinal cord dose. Plans were developed for five to 27 beams. All plans were renormalized such that the target volume receiving the prescription dose was the same for all plans of each site. For each case, we calculated the spinal cord D{sub 0.5cm{sup 3}} (the dose such that 0.5 cm{sup 3} of normal tissue receives greater than or equal to D{sub 0.5cm{sup 3}}), normal tissue D{sub 1cm{sup 3}}, the normal tissue mean dose, and the standard deviation of dose in the planning target volume (PTV). For the head and neck cases, the mean increase in spinal cord D{sub 0.5cm{sup 3}} between seven and 27 beam plans was 10% of the prescription dose, whereas for the paraspinal case, the increase was 2.6%. For the head and neck cases, the mean decrease in normal tissue D{sub 1cm{sup 3}} between seven and 11 beam plans was 2.6% and was constant for more than 11 beams. For the paraspinal cases, the mean decrease in normal tissue D{sub 1cm{sup 3}} between seven and 27 beam plans was 3.7%. The mean normal tissue dose was approximately independent of the number of beams for both sites. For the head and neck cases, the PTV standard deviation was independent of the number of beams, while for the paraspinal cases it decreased by an average of 1.8% from seven to 27 beams. Calculations for seven and 27 beams in which the MLC transmission was varied from 0% to 2% demonstrated that the increase in spinal cord D{sub 0.5cm{sup 3}} with increasing number of beams is largely due to MLC transmission, which is not included in the optimization. Increasing the number of beams increased the critical structure dose, although decreasing beam number results in increasing normal tissue D{sub 1cm{sup 3}} and target dose heterogeneity. The optimal tradeoff is dependent on the clinical situation, but seems to be seven to nine beams. Beam geometry optimization may reduce the number of beams required to provide adequate target coverage, thus limiting critical structure dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗