Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Characterization of the ionization chamber for the SPIDER detector

We request 3 days of ATLAS beams for testing the ionization chamber component of the SPIDER detector, a spectrometer for mea suring the mass yields of neutron-induced fission fragments. The ion ization chamber will be a stand alone detector to be coupled to the end of the beam pipe at zero degrees. These tests are a mass and energy specific characterization of the ionization chamber operating conditions specific to SPIDER, including entrance window material options. Once tested, the results will be applied to the energy cal ibration process of SPIDER, a crucial step to achieving high mass resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GoAmazon 2014/15 Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) Field Campaign Report

The Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) deployment to the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility T3 site in Manacapuru, Brazil, was motivated by two main scientific objectives of the Green Ocean Amazon (GoAmazon) 2014/15 field campaign. 1) Study the interactions between anthropogenic and biogenic emissions by determining important molecular species in ambient nanoparticles. To address this, TDCIMS data will be combined with coincident measurements such as gas-phase sulfuric acid to determine the contribution of sulfuric acid condensation to nucleation and growth. We can then compare that result to TDCIMS-derived nanoparticle composition to determine the fraction of growth that can be attributed to the uptake of organic compounds. The molecular composition of sampled particles will also be used to attribute specific chemical species and mechanisms to growth, such as the condensation of low-volatility species or the oligomerization of α-dicarbonyl compounds. 2) Determine the source of new ambient nanoparticles in the Amazon. The hypothesis prior to measurements was that potassium salts formed from the evaporation of primary particles emitted by fungal spores can provide a unique and important pathway for new particle production in the Amazon basin. To explore this hypothesis, the TDCIMS recorded the mass spectra of sampled ambient particles using a protonated water cluster Chemical Ionization Mass Spectrometer (CIMS). Laboratory tests performed using potassium salts show that the TDCIMS can detect potassium with high sensitivity with this technique.

54 ENVIRONMENTAL SCIENCES↗

Observations and Modeling of the Green Ocean Amazon 2014/15: Hydroxyl Radical (OH) Chemical Ionization Mass Spectrometer (CIMS) Field Campaign Report

The University of California, Irvine, science team (Dr. Saewung Kim, Dr. Roger Seco, Dr. Alex Guenther, and Dr. Jim Smith) deployed a chemical ionization mass spectrometer system for hydroxyl radical (OH) and sulfuric acid quantifications. As part of the GoAmazon 2014/15 field campaign. Hydroxyl radical determines tropospheric oxidation capacity and had been expected to be very low in the pristine rain forest region such as the Brazilian Amazon because of the presence of significant levels of highly reactive biogenic volatile organic compounds and very low levels of NO, which is an OH recycling agent. However, several recent in situ OH observations provided by a laser-induced fluorescence system reported unaccountably high OH concentrations. To address this discrepancy, a series of laboratory and theoretical studies has postulated chemical reaction mechanisms of isoprene that may regenerate OH in photo-oxidation processes. Along with these efforts, potential artifacts on the laser induced fluorescence system from isoprene and its oxidation products also have been explored. Therefore, the first chemical ionization mass spectrometer observations at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s T3 site in Manacapuru, Brazil, are expected to provide a critical experimental constraint to address uncertainty in constraining oxidation capacity over pristine rain forest environments. In addition, we deployed a National Center for Atmospheric Research (NCAR) proton transfer reaction time-of-flight mass spectrometer to characterize atmospheric volatile organic compound levels, especially isoprene and its oxidation products, which are critical input parameters for box modeling to simulate OH with different isoprene photo-oxidation schemes. As there has been no report on noticeable new particle formation events, our first in situ sulfuric acid observations in the Amazon rain forest were expected to constrain the reasons behind such observations. The planned field observations during Intensive Observational Periods I and II, post-field campaign calibrations, and preliminary data reports have been completed. We presented preliminary data analysis results at the 2014 American Geophysical Union Fall meeting and the GOAmazon Science Meeting in Boston (May 2015). We are in the process of submitting two more abstracts to the 2015 American Geophysical Union fall meeting while we are preparing two manuscripts to be submitted to (tentatively) the GOAmazon special issue of Atmospheric Chemistry and Physics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Graphene-based filament material for thermal ionization

The use of graphene oxide materials for thermal ionization mass spectrometry analysis of plutonium and uranium has been investigated. Filament made from graphene oxide slurries have been 3-D printed. A method for attaching these filaments to commercial thermal ionization post assemblies has been devised. Resistive heating of the graphene based filaments under high vacuum showed stable operation in excess of 4 hours. Plutonium ion production has been observed in an initial set of filaments spiked with the Pu 128 Certified Reference Material.

36 MATERIALS SCIENCE↗

Partitioning of Ionization and Displacement Kerma in Material Response Functions

Calculations of total dose (relatable to heating) and ionizing dose (relatable to electron - hole pair formation) typically rely upon material kerma response functions and an assumption of charged particle equilibrium. Traditionally, kerma functions designed for use with the Sandia ASC NuGET code were created via the HEATR module of the NJOY code system, in which a simplifying monoatomic assumption in made. The purpose of this study is to relax that approximation through the use of binary collision simulation techniques, which can take into account the co - existence of multiple elements in a material. Specifically, the total, ionization, and displacement components of kerma are evaluated in silicon, gallium arsenide, gallium nitride, and indium phosphide using the TRIM and MARLOWE codes, and are compared against the equivalent NJOY - based functions. Based on the results, a binary collision - based methodology is proposed for extracting the partial kerma components of high - importance materials.

36 MATERIALS SCIENCE↗

Predicting Ionizing Radiation Exposure (LDRD Final Report)

Rapid, low-cost, easy-to-use devices are needed for screening large populations potentially exposed to ionizing radiation following accidental or intentional release of radioactive materials. Measurements of radiation responsive messenger RNA (mRNA) biomarkers using fieldable devices could provide such a tool. mRNA expression level changes may be useful for discriminating between exposed individuals and the worried well and estimating the radiation dose received even days after exposure. Loop mediated isothermal amplification, or LAMP, is an established nucleic acid amplification technique that provides key advantages for use in low cost, portable instruments. We proposed to use LAMP to determine if the expression level of one or a small number of radiation responsive biomarkers can be used to discriminate unexposed cells from ionizing radiation (IR)-exposed cells. If successful, this methodology could potentially be transitioned to portable detection technology for use in population screening after large-scale events. Our approach involved designing quantitative, real-time, reverse transcriptase loop-mediated isothermal amplification (RTLAMP) assays for a panel of published IR-responsive mRNA biomarkers and control genes. This assay panel was then tested on mRNA isolated from white blood cells, lymphocyte cell lines and samples from internally dosed individuals. We used standard curves to quantify mRNA copy number along with the comparative Ct method to measure relative mRNA expression changes. We were able to generate quantitative and comparative gene expression changes for many of the samples evaluated. Although promising in its potential to measure gene expression, the technique suffered when attempting to amplify target genes with very low background RNA expression levels, in particular, FDXR in controls samples. Future work should focus on optimizing the RT-LAMP reaction for low RNA expression level targets allowing for the generation of validated assay panels.

59 BASIC BIOLOGICAL SCIENCES↗

Ionization-Based Optical Structures for the Control of Short-Pulse Lasers (Full LDRD Report)

High-power lasers require enormous beam sizes to avoid optics damage; without plasma control of light, future higher-power systems will have prohibitive costs. The laser-induced formation of ionization patterns in gases provides an opportunity to manipulate the spatial and temporal properties of femtosecond to picosecond beams with precise control at high intensity, providing a path towards compact multi-petawatt lasers. In this project, we proposed new concepts of diffractive optics elements relying on ionization-based structures, including a holographic lens and a compression grating. The theoretical characterization of these optical elements was supported by particle-in-cell simulations. Experiments have been carried out to achieve reflective elements (i.e., plasma-based gratings) that demonstrated high robustness and efficiencies on the order of 50%, which validates the feasibility of our new concepts and paves the way for future plasma-based high-power laser systems.

47 OTHER INSTRUMENTATION↗

Group-V acceptor ionization energies and compensation centers in CdTe revisited

Group-V acceptor ionization energies and compensation centers in CdTe revisited: Spin-orbit coupling is crucial to describe the band structure of CdTe and the properties of group-V acceptors in CdTe; explains the difference between present work and previous calc. P, As, and Sb are shallow acceptors in CdTe, with the ionization energies ~100 meV, in agreement with recent Hall measurements in bulk crystals AX center is not the dominant compensation center in p-type CdTe; unstable in the case of As and P, barely stable in the case of Sb doping Intrinsic defects, such as VTe, are potentially important compensation centers Cdi is unstable with low migration barrier

14 SOLAR ENERGY↗

Mu2e: Modeling Drift of Ionized Particles with ML

The Mu2e experiment searches for charged lepton flavor violation through muon-to-electron conversion in the field of a nucleus. The signal is a monoenergetic electron with an energy of 104.97 MeV. Its momentum is reconstructed using information from drifting ionized particles in a straw tracker detector. This project analyzes the drift of ionized particles with a deep neural network to help improve the momentum reconstruction process. The model yields a 20% improvement in resolution from a reference linear model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FY26 MID-YEAR REPORT 238 Pu Measurement in Bulk Environmental Samples by Thermal Ionization Mass Spectrometry (TIMS)

Funding was received in December 2026 to optimize a nascent measurement capability for mass spectrometry of 238 Pu, as it would apply to relevant environmental collections in safeguards applications, i.e. NWAL swipes or other bulk collections such as soil, sediment, waters, or air filters. The measurement relies on differing ionization temperatures for U and Pu during thermal ionization and therefore leverages TIMS to partially separate and measure these elements. Collected counts of 238 Pu can be mathematically corrected for interfering counts of background 238 U, by addition of a U tracer (e.g. 235 U) to account for the 238 U present. The method has undergone initial characterization at LANL regarding detection limit, precision, and accuracy but requires further applicability-testing for possible use in safeguards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Studying Interfacial Dark Reactions of Glyoxal and Hydrogen Peroxide Using Vacuum Ultraviolet Single Photon Ionization Mass Spectrometry

Aqueous secondary organic aerosol (aqSOA) formation from volatile and semivolatile organic compounds at the air–liquid interface is considered as an important source of fine particles in the atmosphere. However, due to the lack of in situ detecting techniques, the detailed interfacial reaction mechanism and dynamics still remain uncertain. In this study, synchrotron-based vacuum ultraviolet single-photon ionization mass spectrometry (VUV SPI-MS) was coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI) to investigate glyoxal dark oxidation products at the aqueous surface. Mass spectral analysis and determination of appearance energies (AEs) suggest that the main products of glyoxal dark interfacial aging are carboxylic acid related oligomers. Furthermore, the VUV SPI-MS results were compared and validated against those of in situ liquid time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reaction mechanisms of the dark glyoxal interfacial oxidation, obtained using two different approaches, indicate that differences in ionization and instrument operation principles could contribute to their abilities to detect different oligomers. Therefore, the mechanistic differences revealed between the VUV SPI-MS and ToF-SIMS indicate that more in situ and real-time techniques are needed to investigate the contribution of the air–liquid interfacial reactions leading to aqSOA formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme Ultraviolet Spectra of Few-Times Ionized Tungsten for Divertor Plasma Diagnostics

The extreme ultraviolet (EUV) emission from few-times ionized tungsten atoms has been experimentally studied at the Livermore electron beam ion trap facility. The ions were produced and confined during low-energy operations of the EBIT-I electron beam ion trap. By varying the electron-beam energy from around 30–300 eV, tungsten ions in charge states expected to be abundant in tokamak divertor plasmas were excited, and the resulting EUV emission was studied using a survey spectrometer covering 120–320 Å. It is found that the emission strongly depends on the excitation energy; below 150 eV, it is relatively simple, consisting of strong isolated lines from a few charge states, whereas at higher energies, it becomes very complex. For divertor plasmas with tungsten impurity ions, this emission should prove useful for diagnostics of tungsten flux rates and charge balance, as well as for radiative cooling of the divertor volume. Several lines in the 194–223 Å interval belonging to the spectra of five- and seven-times ionized tungsten (Tm-like W VI and Ho-like W VIII) were also measured using a high-resolution spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionizing Radiation Sensing with Functionalized and Copper-Coated SWCNT/PMMA Thin Film Nanocomposites

This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

36 MATERIALS SCIENCE↗

Quantitative Proteomic Profiling of Low Dose Ionizing Radiation Effects in a Human Skin Model

To assess molecular responses to low doses of radiation that may be encountered during medical diagnostic procedures, nuclear accidents, or terrorist acts, a quantitative global proteomic approach was used to identify protein alterations in a reconstituted human skin tissue treated with 10 cGy of ionizing radiation. Subcellular fractionation was employed to remove highly abundant structural proteins and provide insight on radiation induced alterations in protein abundance and localization. In addition, peptides were post-fractionated using high resolution 2-dimensional liquid chromatography to increase the dynamic range of detection of protein abundance and translocation changes. Quantitative data was obtained by labeling peptides with 8-plex isobaric iTRAQ tags. A total of 207 proteins were detected with statistically significant alterations in abundance and/or subcellular localization compared to sham irradiated tissues. Bioinformatics analysis of the data indicated that the top canonical pathways affected by low dose radiation are related to cellular metabolism. Among the proteins showing alterations in abundance, localization and proteolytic processing was the skin barrier protein filaggrin which is consistent with our previous observation that ionizing radiation alters profilaggrin processing with potential effects on skin barrier functions. In addition, a large number of proteases and protease regulators were affected by low dose radiation exposure indicating that altered proteolytic activity may be a hallmark of low dose radiation exposure. While several studies have demonstrated altered transcriptional regulation occurs following low dose radiation exposures, the data presented here indicates post-transcriptional regulation of protein abundance, localization, and proteolytic processing play an important role in regulating radiation responses in complex human tissues.

Environmental Molecular Sciences Laboratory↗

FAST, LOW-IONIZATION EMISSION REGIONS OF THE PLANETARY NEBULA M2-42

Spatially resolved observations of the planetary nebula M2-42 (PN G008.2−04.8) obtained with the Wide Field Spectrograph on the Australian National University 2.3 m telescope have revealed the remarkable features of bipolar collimated jets emerging from its main structure. Velocity-resolved channel maps derived from the [N ii] λ6584 emission line disentangle different morphological components of the nebula. This information is used to develop a three-dimensional morpho-kinematic model, which consists of an equatorial dense torus and a pair of asymmetric bipolar outflows. The expansion velocity of about 20 km s{sup −1} is measured from the spectrum integrated over the main shell. However, the deprojected velocities of the jets are found to be in the range of 80–160 km s{sup −1} with respect to the nebular center. It is found that the mean density of the collimated outflows, 595 ± 125 cm{sup −3}, is five times lower than that of the main shell, 3150 cm{sup −3}, whereas their singly ionized nitrogen and sulfur abundances are about three times higher than those determined from the dense shell. The results indicate that the features of the collimated jets are typical of fast, low-ionization emission regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Hubble imaging of the ionizing radiation from a star-forming galaxy at Z = 3.2 with f{sub esc}>50%

Star-forming galaxies are considered to be the leading candidate sources dominating cosmic reionization at z>7: the search for analogs at moderate redshift showing Lyman continuum (LyC) leakage is currently an active line of research. We have observed a star-forming galaxy at z = 3.2 with Hubble/WFC3 in the F336W filter, corresponding to the 730–890 Å rest-frame, and detected LyC emission. This galaxy is very compact and also has a large Oxygen ratio [O III]λ5007/[O II]λ3727 (≳10). No nuclear activity is revealed from optical/near-infrared spectroscopy and deep multi-band photometry (including the 6 Ms X-ray Chandra observations). The measured escape fraction of ionizing radiation spans the range 50%–100%, depending on the intergalactic medium (IGM) attenuation. The LyC emission is measured at m{sub F336W}=27.57±0.11 (with signal-to-noise ratio (S/N) = 10) and is spatially unresolved, with an effective radius of R{sub e}<200 pc. Predictions from photoionization and radiative transfer models are in line with the properties reported here, indicating that stellar winds and supernova explosions in a nucleated star-forming region can blow cavities generating density-bounded conditions compatible to optically thin media. Irrespective of the nature of the ionizing radiation, spectral signatures of these sources over the entire electromagnetic spectrum are of central importance for their identification during the epoch of reionization when the LyC is unobservable. Intriguingly, the Spitzer/IRAC photometric signature of intense rest-frame optical emissions ([O iii]λλ4959,5007 + Hβ) recently observed at z≃7.5--8.5 is similar to what is observed in this galaxy. Only the James Webb Space Telescope will measure optical line ratios at z>7, allowing a direct comparison with the lower-redshift LyC emitters, such as that reported here.

79 ASTRONOMY AND ASTROPHYSICS↗

THE IONIZED GAS IN NEARBY GALAXIES AS TRACED BY THE [NII] 122 AND 205 μm TRANSITIONS

The [N ii] 122 and 205 μ m transitions are powerful tracers of the ionized gas in the interstellar medium. By combining data from 21 galaxies selected from the Herschel KINGFISH and Beyond the Peak surveys, we have compiled 141 spatially resolved regions with a typical size of ∼1 kpc, with observations of both [N ii] far-infrared lines. We measure [N ii] 122/205 line ratios in the ∼0.6–6 range, which corresponds to electron gas densities of n {sub e} ∼ 1–300 cm{sup −3}, with a median value of n {sub e} = 30 cm{sup −3}. Variations in the electron density within individual galaxies can be as high as a factor of ∼50, frequently with strong radial gradients. We find that n {sub e} increases as a function of infrared color, dust-weighted mean starlight intensity, and star-formation rate (SFR) surface density (Σ{sub SFR}). As the intensity of the [N ii] transitions is related to the ionizing photon flux, we investigate their reliability as tracers of the SFR. We derive relations between the [N ii] emission and SFR in the low-density limit and in the case of a log-normal distribution of densities. The scatter in the correlation between [N ii] surface brightness and Σ{sub SFR} can be understood as a property of the n {sub e} distribution. For regions with n {sub e} close to or higher than the [N ii] line critical densities, the low-density limit [N ii]-based SFR calibration systematically underestimates the SFR because the [N ii] emission is collisionally quenched. Finally, we investigate the relation between [N ii] emission, SFR, and n {sub e} by comparing our observations to predictions from the MAPPINGS-III code.

79 ASTRONOMY AND ASTROPHYSICS↗