Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPURITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart Pensinger↗

Developmental Hardware Testing Results and Forward Plans for the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Developmental Hardware Testing Results and Forward Plans for Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

COMPACT QEPAS SENSOR FOR TRACE METHANE AND AMMONIA DETECTION IN IMPURE HYDROGEN

A compact two-gas sensor based on quartz enhanced photoacoustic spectroscopy (QEPAS) was developed for trace methane and ammonia quantification in impure hydrogen. The sensor is equipped with a micro-resonator to confine the sound wave and enhance QEPAS signal. The normalized noise-equivalent absorption coefficients (1{sigma}) of 2.45 x 10{sup -8} cm{sup -1}W/{radical}Hz and 9.1 x 10{sup -9} cm{sup -1}W/{radical}Hz for CH{sub 4} detection at 200 Torr and NH{sub 3} detection at 50 Torr were demonstrated with the QEPAS sensor configuration, respectively. The influence of water vapor on the CH{sub 4} channel was also investigated.

08 HYDROGEN↗

Impurity-induced disorder in III-nitride materials and devices

A method for impurity-induced disordering in III-nitride materials comprises growing a III-nitride heterostructure at a growth temperature and doping the heterostructure layers with a dopant during or after the growth of the heterostructure and post-growth annealing of the heterostructure. The post-growth annealing temperature can be sufficiently high to induce disorder of the heterostructure layer interfaces.

36 MATERIALS SCIENCE↗

FEASIBILITY OF ACOUSTIC METHODS FOR IMPURITY GAS MONITORING IN DRY STORAGE SYSTEMS

This paper explores the feasibility of monitoring impurities in dry storage containers (DSCs) for spent nuclear fuel using non-invasive acoustic sensing. The conceived implementation considers measurements based on changes in acoustic velocity at successive measurement intervals. Uncertainty contributions from the measurement system and temperature variability are estimated. Sources of temperature variability considered include changes in the decay heat source over time and ambient temperature variation. The results show that performance of a system which does not incorporate temperature compensation will be dependent upon geographic location and the decay heat source strength. The results also indicate that an annual measurement interval is optimal.

eddy current↗

Laser weldability of 21Cr-6Ni-9Mn stainless steel: Part I - Impurity effects and solidifcation mode

For laser welded type 21Cr-6Ni-9Mn (21-6-9) stainless steels, the relationship between solidification cracking susceptibility and chemical composition was examined, and primary solidification mode (PSM) diagrams were developed to predict solidification mode. Sigmajig testing was used with experimental heats of type 21-6-9 to determine the effect of P and S on solidification cracking w hen primary austenite solidification occurred. Phosphorus showed a larger influence on solidification cracking relative to S, and a relationship of (P+0.2S ) was found for total impurity content. PSM diagrams to predict solidification mode were developed by analyzing welds made at three travel speeds for a wide range of 21-6-9 alloys and some other similar alloys. The minimum Cr eq /Ni eq required for primary ferrite solidification increased as travel speed increased, with more alloys showing primary austenite solidification at higher travel rates. Furthermore, as travel speed increased from 21 to 85 mm/s, the average solidification rate increased from 6 to 25 mm/s.

21-6-9, Nitronic 40, laser welding↗

First application of the massively-parallel Monte Carlo code ERO2.0 for plasma-wall interaction and 3D local impurity transport at JET ILW

Here, estimating erosion for plasma-facing components (PFCs) is one of the key issues for ITER. Effective sputter yields can be obtained experimentally e.g. by estimating flux ratios with S/XB ratios. The interpretation of such experiments and extrapolation to ITER conditions is not straightforward, because the effective yields result from a complex interplay of plasma conditions, wall geometry and impurity transport. This makes modelling tools like the Monte Carlo code ERO necessary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduction of impurities in battery electrolyte

A method of a reducing impurities in an electrolyte includes contacting one or more components of an electrolyte with a zeolite. The method also includes activating one or more anode and one or more cathodes with the electrolyte. Contacting the one or more components with the zeolite can include contacting the electrolyte with the zeolite. In some instances, the method includes preparing the electrolyte after contacting the one or more components of the electrolyte with the zeolite.

Nakahara, Hiroshi↗

Processes and catalysts for reforming of impure methane-containing feeds

Processes and catalysts for producing hydrogen by reforming methane are disclosed, which afford considerable flexibility in terms of the quality of the reformer feed. This can be attributed to the robustness of the noble metal-containing catalysts described herein for use in reforming, such that a number of components commonly present in methane-containing process streams can advantageously be maintained without conventional upgrading (pretreating) steps, thereby improving process economics. This also allows for the reforming of impure reformer feeds, even in relatively small quantities, which may be characterized as complex gas mixtures due to significant quantities of non-methane components. A representative reforming catalyst comprises 1 wt-% Pt and 1 wt-% Rh as noble metals, on a cerium oxide support.

Marker, Terry L.↗

Computational Studies of Gas Phase Reactions of Zirconium Tetrachloride (ZrCl{sub 4}) and Metal Chloride Impurities

Zirconium-based cladding materials that surround used nuclear fuel (UNF) rods represent a significant fraction of the total amount of high level waste that must be disposed of in long term geological repositories. The decontamination, recovery and reuse of these materials would significantly reduce the high level waste associated with light water reactors and could provide a new source of hafnium free zirconium for the fabrication of new nuclear components. One part in the strategy to recycle zirconium from used cladding materials involves developing a computational modeling (DFT) protocol to understand the reactions between ZrCl{sub 4} and metal chloride impurities that may occur in the gas phase during sublimation. Several of the metal chloride species present are known to form Lewis acid/base adducts in the gas phase and development of purification protocols require investigation into the properties of these ZrCl{sub 4} contaminates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Minor Alloying Elements and Impurities on Long-Range Ordering in Ni-Cr-Based Alloys

There is growing concern about long-range ordered Ni2Cr phase forming during thermal aging of Ni-Cr-based alloys (e.g., 690, 625), which leads to lattice contraction, hardening, and embrittlement, possibly limiting the service life of light water reactor components. The timespan when this phase transformation occurs can vary in orders of magnitude between model and commercial alloys and is likely related to the presence of major (e.g., Fe, Mo) and minor alloying elements (e.g., Ti, Si, Nb). These minor alloying elements have been hypothesized to bind with vacancies and therefore limit diffusion. Contrarily, impurities (e.g., P, S) are believed to enhance vacancy diffusion and accelerate the Ni2Cr phase transformation because of a vacancy drag mechanism. This study implements experimental isothermal aging of model Ni-Cr binary and Ni-Cr-X ternary alloys, where X is Ti, Si, Nb, and P to help understand how each minor alloying element affects the Ni2Cr phase transformation timeline. Synchrotron-based X-ray diffraction and hardness measurements are used to quantify the evolution of the Ni2Cr phase transformation through a variety of short aging times to identify the onset of long-range order. These experimental results are compared to first principles simulations from literature to understand the mechanism by which each element impacts vacancy diffusion and the formation of the long-range ordered phase, Ni2Cr.

36 - MATERIALS SCIENCE↗

Interaction of coal-derived synthesis gas impurities with solid oxide fuel cell metallic components

Chromium-containing iron-based alloys Crofer22 APU and SS 441 and nickel-based alloy Inconel600, all commonly used in a solid oxide fuel cell (SOFC) stack as interconnect materials, heat exchanger and gas feeding pipes, were exposed at 700-850oC to a synthetic coal gas containing ≤2 ppm phosphine, arsine, sulfur and antimony. Samples were characterized by SEM/EDS and XRD to monitor the secondary phase formation. Exposure of ferritic stainless steels to P led to the formation of surface Cr-Mn-P-O and Fe-P-O compounds and increased temperatures accelerated the rate of interactions. Fewer interactions were observed after exposures to As and Sb. No sulfur containing compounds were found. Nickel-based alloy exhibited much stronger interactions with As and P in comparison with ferritic steels and the arsenic interactions were particularly strong. The difference between the iron- and nickel-based alloys is explained by the different chemistry and morphology of the scales grown on the alloy surfaces in coal gas. While P and As interactions with the metallic parts in the SOFC are likely to mitigate the nickel/zirconia anode poisoning, the other degradation mechanisms should be taken into consideration to avoid potential stack failures. Manganese spinels were found to be effective as phosphorus getters and could be used in coal gas cleanup.

01 COAL, LIGNITE, AND PEAT↗