Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

The 1997 HST Calibration Workshop with a New Generation of Instruments

The Second Servicing mission in early 1997 has brought major changes to the Hubble Space Telescope (HST). Two of the original instruments, Faint Object Spectrograph (FOS) and Goddard High Resolution Spectrograph (GHRS), were taken out, and replaced by completely new instruments, the Space Telescope Imaging Spectrograph (STIS) and the Near Infrared Camera Multi-Object Spectrograph (NICMOS). Two new types of detectors were installed, and for the first time, HST gained infrared capabilities. A new Fine Guidance Sensor (FGS) was installed, with an alignment mechanism that could improve substantially both guiding and astrometric capabilities. With all these changes come new challenges. The characterization of the new instruments has required a major effort, both by their respective Investigation Definition Teams and at the Space Telescope Science Institute. All necessary final calibrations for the retired spectrographs needed to be carried out, and their properties definitively characterized. At the same time, work has continued to improve our understanding of the instruments that have remained on board. The results of these activities were discussed in the 1997 HST (Hubble Space Telescope) Calibration Workshop. The main focus of the Workshop was to provide users with the tools and the understanding they need to use HST's instruments and archival data to the best of their possibilities. This book contains the written record of the Workshop. As such, it should provide a valuable tool to all interested in using existing HST data or in proposing for new observations.

Casertano, S.↗

Density-Based Optical Diagnostic Techniques at Nasa Langley Research Center

Several density-based optical diagnostic techniques under development for both ground test facilities and flight vehicles at NASA Langley Research Center will be presented. I will first discuss recent development work on focused laser differential interferometry (FLDI) for Langley’s hypersonic test facilities, including multi-point FLDI and co-linear FLDI/schlieren imaging. I will then discuss our work on tomographic background-oriented schlieren (Tomo BOS) and the challenges associated with its implementation in Langley’s ground test facilities. Finally, I will present results obtained with a new self-aligned focusing schlieren technique my team has developed and discuss how this technique is a significant improvement over traditional focusing schlieren systems.

Brett Bathel↗

Automatic Segmentation of the Eye in 3D Magnetic Resonance Imaging: A Novel Statistical Shape Model for Treatment Planning of Retinoblastoma

Purpose: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. Methods and Materials: Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. Results: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. Conclusion: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Slender Ca ii H Fibrils Mapping Magnetic Fields in the Low Solar Chromosphere

A dense forest of slender bright fibrils near a small solar active region is seen in high-quality narrowband Ca ii H images from the SuFI instrument onboard the Sunrise balloon-borne solar observatory. The orientation of these slender Ca ii H fibrils (SCF) overlaps with the magnetic field configuration in the low solar chromosphere derived by magnetostatic extrapolation of the photospheric field observed with Sunrise/IMaX and SDO/HMI. In addition, many observed SCFs are qualitatively aligned with small-scale loops computed from a novel inversion approach based on best-fit numerical MHD simulation. Such loops are organized in canopy-like arches over quiet areas that differ in height depending on the field strength near their roots.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud Ozone Dust Imager (CODI): Investigation and Technical Plan - Volume 1

The Cloud Ozone Dust Imager (CODI) is proposed to investigate the current climatic balance of the Mars atmosphere, with particular emphasis on the important but poorly understood roles which dust and water ice aerosols play in this balance. The large atmospheric heating (20-50 K) resulting from global dust storms around Mars perihelion is well recognized. However, groundbased observations of Mars atmospheric temperatures, water vapor, and clouds since the Viking missions have identified a much colder, cloudier atmosphere around Mars aphelion that may prove as important as global dust storms in determining the interannual and long-term behavior of the Mars climate. The key climate issues CODI is designed to investigate are: 1) the degree to which non-linear interactions between atmospheric dust heating, water vapor saturation, and cloud nucleation influence the seasonal and interannual variability of the Mars atmosphere, and 2) whether the strong orbital forcing of atmospheric dust loading, temperatures and water vapor saturation determines the long-term balance of Mars water, as reflected in the north-south hemispheric asymmetries of atmospheric water vapor and polar water ice abundances. The CODI experiment will measure the daily, seasonal and (potentially) interannual variability of atmospheric dust and cloud opacities, and the key physical properties of these aerosols which determine their role in the climate cycles of Mars. CODI is a small (1.2 kg), fixed pointing camera, in which four wide-angle (+/- 70 deg) lenses illuminate fixed filters and CCD arrays. Simultaneous sky/surface imaging of Mars is obtained at an angular resolution of 0.28 deg/pixel for wavelengths of 255, 336, 502, and 673 nm (similar to Hubble Space Telescope filters). These wavelengths serve to measure atmospheric ozone (255 and 336 nm), discriminate ice and dust aerosols (336 and 673 nm), and construct color images (336, 502, and 673 nm). The CODI images are detected on four 512 x 512 pixel arrays, as partitioned on two 1024 x 1024 CCD's operated in frame transfer mode. The center of the CODI field-of-view is canted 40 deg from the zenith direction to obtain sky brightness measurements and a 20 deg surface field-of-view. Daily image observations will be conducted when the Sun is greater than or equal to 5 deg outside the edge of the CODI field-of-view, and twilight and nighttime imaging will obtained on a weekly basis. The 673 nm channel includes a polarizer wheel to obtain sky/surface polarimetry. A dust cover protects the entire lens assemblies of all four CODI channels. This opaque dust cover, which is normally opened for CODI imaging, includes a small fixed mirror and transparent window positioned above the 673 nm lens, to redirect the 673 nm field-of-view to the surface for descent imaging. Fixed pointing, internal data buffering, low operating power (2-4 W for less than or equal to 30 seconds), selective data transmission, and simple operational characteristics of the CODI experiment place minimum resource and operational demands on the Mars Surveyor 1998 lander. The CODI science goals are optimized for, but not restricted to, a low-latitude landing site (20 deg S-30 deg N). The primary CODI measurement objectives are the opacities, wave forms, particle properties (size, shape, and alignment), and heights of clouds; the opacities, particle properties, and vertical distribution of dust; and the opacity and vertical distribution of ozone. The variability of cloud, ozone, and dust opacities will be determined on diurnal, daily, and seasonal timescales. Wind velocities will be determined from cloud motions and wave characteristics; and the temporal variability of atmospheric water vapor, with limited altitude information, will be inferred from the CODI ozone observations. Secondary measurement objectives include limited descent imaging capability, surface uv-visible photometry and polarimetry, photochemistry, and meteorite infall rates.

Clancy, R. Todd↗

A three-point velocity estimation method for two-dimensional coarse-grained imaging data

Time delay and velocity estimation methods have been widely studied subjects in the context of signal processing, with applications in many different fields of physics. The velocity of waves or coherent fluctuation structures is commonly estimated as the distance between two measurement points divided by the time lag that maximizes the cross correlation function between the measured signals, but this is demonstrated to result in erroneous estimates for two spatial dimensions. We present an improved method to accurately estimate both components of the velocity vector, relying on three non-aligned measurement points. We introduce a stochastic process describing the fluctuations as a superposition of uncorrelated pulses moving in two dimensions. Using this model, we show that the three-point velocity estimation method, using time delays calculated through cross correlations, yields the exact velocity components when all pulses have the same velocity. The two- and three-point methods are tested on synthetic data generated from realizations of such processes for which the underlying velocity components are known. The results reveal the superiority of the three-point technique. Finally, we demonstrate the applicability of the velocity estimation on gas puff imaging data of strongly intermittent plasma fluctuations due to the radial motion of coherent, blob-like structures at the boundary of the Alcator C-Mod tokamak.

Materials Science↗

SU-E-J-105: Trusting Dose Deformation and Accumulation for GYN Brachytherapy

Purpose: In brachytherapy, structures surrounding the target have the potential to move between treatments and receive unknown dose. Deformable image registration could overcome challenges through dose accumulation. This study uses two possible deformable dose summation techniques and compares the results to point dose summation currently performed in clinic. Methods: Data for ten patients treated with a Syed template was imported into the MIM software (Cleveland, OH). The deformable registration was applied to structures by masking other image data to a single intensity. The registration flow consisted of the following steps: 1) mask CTs so that each of the structures-of-interest had one unique intensity; 2) perform applicator — based rigid registration; 3) Perform deformable registration; 4) Refine registration by changing local alignments manually; 5) Repeat steps 1 to 3 until desired structure adequately deformed; 5) Transfer each deformed contours to the first CT. The deformed structure accuracy was determined by a dice similarity coefficient (DSC) comparison with the first fraction. Two dose summation techniques were investigated: a deformation and recalculation on the structure; and a dose deformation and accumulation method. Point doses were used as a comparison value. Results: The Syed deformations have DSC ranging from 0.53 to 0.97 and 0.75 and 0.95 for the bladder and rectum, respectively. For the bladder, contour deformation addition ranged from −34.8% to 0.98% and dose deformation accumulation ranged from −35% to 29.3% difference from clinical calculations. For the rectum, contour deformation addition ranged from −5.2% to 16.9% and the dose deformation accumulation ranged from −29.1% to 15.3% change. Conclusion: Deforming dose for summation leads to different volumetric doses than when dose is recalculated on deformed structures, raising concerns about the accuracy of the deformed dose. DSC alone cannot be used to establish the accuracy of a deformation for brachy dose summation purpose.

60 APPLIED LIFE SCIENCES↗

Synergistic Alignment of Low Aspect‐Ratio π‐Conjugated Molecules Enables Exceptional UV–vis–NIR Polarization Detection

Abstract Polarization detection enhances signal contrast and is widely utilized in diverse advanced applications. An ongoing challenge is the development of high‐performance polarization‐sensitive photodetectors based on optically anisotropic organic semiconductors, particularly in the near‐infrared (NIR) region. While uniaxially aligned π‐conjugated polymers with high aspect ratios exhibit strong linear dichroism and have shown promise, their limited NIR performance and heavy reliance on polymer material now represent critical limitations. Here, a breakthrough is reported in achieving giant linear dichroism and exceptional polarization detection with low aspect‐ratios (AR) non‐fullerene small‐molecule (NFSM) acceptors, extending polarization sensitivity from the UV–vis to the NIR range. An impressive dichroic ratio of 27.1 at 605 nm and 12.0 at 780 nm is demonstrated. The maximum polarization photocurrent ratio is 11.2 at 780 nm under parallel versus perpendicular polarized light. This unprecedented performance originates from synergistic molecular alignment, wherein NFSMs significantly enhance the uniaxial orientation of both the polymer matrix and the NFSMs themselves during self‐assembly and thermal annealing. Besides, such a linear‐polarization‐sensitive photodetectors (LPS‐PDs) are showcased in generating degree‐of‐linear‐polarization imaging. The work establishes NFSMs as a viable material system for next‐generation of organic LPS‐PDs and provides fundamental insights into structural origins of polarization sensitivity in low AR organic semiconductors.

Xue, Yingying↗

Derivation of Multiple Covarying Material and Process Parameters Using Physics-Based Modeling of X-ray Data

There is considerable interest in developing multimodal characterization frameworks capable of probing critical properties of complex materials by relying on distinct, complementary methods or tools. Any such framework should maximize the amount of information that is extracted from any given experiment and should be sufficiently powerful and efficient to enable on-the-fly analysis of multiple measurements in a self-consistent manner. Such a framework is demonstrated in this work in the context of self-assembling polymeric materials, where theory and simulations provide the language to seamlessly mesh experimental data from two different scattering measurements. Specifically, the samples considered here consist of diblock copolymers (BCP) that are self-assembled on chemically nanopatterned surfaces. The copolymers microphase separate into ordered lamellae with characteristic dimensions on the scale of tens of nanometers that are perfectly aligned by the substrate over macroscopic areas. These aligned lamellar samples provide ideal standards with which to develop the formalism introduced in this work and, more generally, the concept of high-information-content, multimodal experimentation. In conclusion, the outcomes of the proposed analysis are then compared to images generated by 3D scanning electron microscopy tomography, serving to validate the merit of the framework and ideas proposed here.

36 MATERIALS SCIENCE↗

Unraveling the Unconventional Order of a High-Mobility Indacenodithiophene-Benzothiadiazole Copolymer

We report a new class of donor–acceptor (D-A) copolymers found to produce high charge carrier mobilities competitive with amorphous silicon (>1 cm 2 V –1 s –1 ) exhibit the puzzling microstructure of substantial local order, however lacking long-range order and crystallinity previously deemed necessary for achieving high mobility. Here, we demonstrate the application of low-dose transmission electron microscopy to image and quantify the nanoscale and mesoscale organization of an archetypal D-A copolymer across areas comparable to electronic devices (≈9 μm 2 ). The local structure is spatially resolved by mapping the backbone (001) spacing reflection, revealing nanocrystallites of aligned polymer chains throughout nearly the entire film. Analysis of the nanoscale structure of its ordered domains suggests significant short- and medium-range order and preferential grain boundary orientations. Moreover, we provide insights into the rich, interconnected mesoscale organization of this new family of D-A copolymers by analysis of the local orientational spatial autocorrelations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Communication: Nuclear quadrupole moment-induced Cotton-Mouton effect in noble gas atoms

New, high-sensitivity and high-resolution spectroscopic and imaging methods may be developed by exploiting nuclear magneto-optic effects. A first-principles electronic structure formulation of nuclear electric quadrupole moment-induced Cotton-Mouton effect (NQCME) is presented for closed-shell atoms. In NQCME, aligned quadrupole moments alter the index of refraction of the medium along with and perpendicular to the direction of nuclear alignment. The roles of basis-set convergence, electron correlation, and relativistic effects are investigated for three quadrupolar noble gas isotopes: {sup 21}Ne, {sup 83}Kr, and {sup 131}Xe. The magnitude of the resulting ellipticities is predicted to be 10{sup −4}–10{sup −6} rad/(M cm) for fully spin-polarized nuclei. These should be detectable in the Voigt setup. Particularly interesting is the case of {sup 131}Xe, in which a high degree of spin polarization can be achieved via spin-exchange optical hyperpolarization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile construction of vertically aligned EuS-ZnO hybrid core shell nanorod arrays for visible light driven photocatalytic properties

We demonstrated the development of coupled semiconductor in the form of hybrid heterostructures for significant advancement in catalytic functional materials. In this article, we report the preparation of vertically aligned core shell ZnO-EuS nanorod photocatalyst arrays by a simple chemical solution process followed by sulfudation process. The XRD pattern confirmed formation of the hexagonal wurtzite structure of ZnO and cubic nature of the EuS. Cross sectional FESEM images show vertical rod array structure, and the size of the nanorods ranges from 80 to 120 nm. UV-Vis DRS spectra showed that the optical absorption of ZnO was significantly enhanced to the visible region by modification with EuS surfaces. TEM study confirmed that the surface of ZnO was drastically improved by the modification with EuS nanoparticle. The catalytic activity of EuS−ZnO core shell nanorod arrays were evaluated by the photodegradation of Methylene Blue (MB) dye under visible irradiation. The results revealed that the photocatalytic activity of EuS−ZnO was much higher than that of ZnO under natural sunlight. EuS−ZnO was found to be stable and reusable without appreciable loss of catalytic activity up to four consecutive cycles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-spectroscopic composition measurements of SrTiO 3 -La 0.7 Sr 0.3 MnO 3 multilayers using scanning convergent beam electron diffraction

The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns to a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Numerical simulation of magnetized jet creation using a hollow ring of laser beams

Three dimensional FLASH magneto-hydrodynamic modeling is carried out to interpret the OMEGA laser experiments of strongly magnetized, highly collimated jets driven by a ring of 20 OMEGA beams. The predicted optical Thomson scattering spectra and proton images are in good agreement with a subset of the experimental data. Here, magnetic fields generated via the Biermann battery term are amplified at the boundary between the core and the surrounding of the jet. The simulation predicts multiple axially aligned magnetic flux ropes with an alternating poloidal component. Future applications of the hollow ring configuration in laboratory astrophysics are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Astrometrically registered simultaneous observations of the 22 GHz H{sub 2}O and 43 GHz SiO masers toward R Leonis Minoris using KVN and source/frequency phase referencing

Oxygen-rich asymptotic giant branch (AGB) stars can be intense emitters of SiO (v = 1 and 2, J = 1 → 0) and H{sub 2}O maser lines at 43 and 22 GHz, respectively. Very long baseline interferometry (VLBI) observations of the maser emission provide a unique tool to probe the innermost layers of the circumstellar envelopes in AGB stars. Nevertheless, the difficulties in achieving astrometrically aligned H{sub 2}O and v = 1 and v = 2 SiO maser maps have traditionally limited the physical constraints that can be placed on the SiO maser pumping mechanism. We present phase-referenced simultaneous spectral-line VLBI images for the SiO v = 1 and v = 2, J = 1 → 0, and H{sub 2}O maser emission around the AGB star R LMi, obtained from the Korean VLBI Network (KVN). The simultaneous multi-channel receivers of the KVN offer great possibilities for astrometry in the frequency domain. With this facility, we have produced images with bona fide absolute astrometric registration between high-frequency maser transitions of different species to provide the positions of the H{sub 2}O maser emission and the center of the SiO maser emission, hence reducing the uncertainty in the proper motions for R LMi by an order of magnitude over that from Hipparcos. This is the first successful demonstration of source frequency phase referencing for millimeter VLBI spectral-line observations and also where the ratio between the frequencies is not an integer.

79 ASTRONOMY AND ASTROPHYSICS↗

More relaxed intracluster gas than galaxies in clusters in quasi-equilibrium

ABSTRACT During cluster mergers, the intracluster gas and member galaxies undergo dynamic evolution, but at different time-scales and reach different states. We collect 24 galaxy clusters in quasi-equilibrium state as indicated by the X-ray image, and calculate the cluster orientations and three kinds of dynamical parameters, i.e. the normalized centroid offset, the sphere index, and the ellipticity, for these clusters from the distributions of member galaxies and also the intracluster gas. We find consistent alignments for the orientations estimated from the two components. However, the three kinds of dynamical parameters indicated by member galaxies are systematically larger than those derived from the gas component, suggesting that the gas component is more relaxed than member galaxies. Differences of dynamical features between the intracluster gas and member galaxies are independent of cluster mass and concentration. We conclude that the intracluster gas reaches the dynamic equilibrium state earlier than the almost-collisionless member galaxies.

Astronomy & Astrophysics↗

Residual strain orientation in rolled titanium determined with synchrotron X-ray Laue microdiffraction

Previously, synchrotron X-ray Laue microdiffraction has been used to measure the magnitudes of residual strain in materials. Recently the method was advanced to determine the orientation of the strain ellipsoid and applied to naturally deformed quartzites; however, the deformation history of these quartzites is ambiguous due to their natural origin. Here, in this study, synchrotron X-ray Laue microdiffraction (µXRD) is used to measure the residual strain for the first time in a sample with known stress history, rolled titanium. A deviatoric strain tensor is calculated from each Laue diffraction image collected with two µXRD scans of a rolled titanium sheet in different sample orientations. The principal strain axes are calculated using an eigen decomposition of the deviatoric strain tensors. The results show that the principal axis of compression is aligned with the normal direction of the titanium sheet, and the principal axis of extension is aligned with the rolling direction. Pole figures are used to represent the 3D distribution of residual strain axes.

36 MATERIALS SCIENCE↗

Systematic errors in Hadamard transform optics

Error sources encountered in Hadamard transform optical instruments are discussed. Such errors are caused by factors including moving masks, incorrect mask alignment, defects in mask fabrication, missing data, drifts in background level, and diffraction. Techniques for error reduction and/or elimination are described for each of the cases considered. It is noted that the errors described occur in singly encoded spectrometers and imagers.

Sloane, N. J. A.↗