Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heart Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

TORQUE ENHANCEMENT, SPIN EQUILIBRIUM, AND JET POWER FROM DISK-INDUCED OPENING OF PULSAR MAGNETIC FIELDS

The interaction of a rotating star’s magnetic field with a surrounding plasma disk lies at the heart of many questions posed by neutron stars in X-ray binaries. We consider the opening of stellar magnetic flux due to differential rotation along field lines coupling the star and disk, using a simple model for the disk-opened flux, the torques exerted on the star by the magnetosphere, and the power extracted by the electromagnetic wind. We examine the conditions under which the system enters an equilibrium spin state, in which the accretion torque is instantaneously balanced by the pulsar wind torque alone. For magnetic moments, spin frequencies, and accretion rates relevant to accreting millisecond pulsars, the spin-down torque from this enhanced pulsar wind can be substantially larger than that predicted by existing models of the disk–magnetosphere interaction, and is in principle capable of maintaining spin equilibrium at frequencies less than 1 kHz. We speculate that this mechanism may account for the non-detection of frequency increases during outbursts of SAX J1808.4-3658 and XTE J1814-338, and may be generally responsible for preventing spin-up to sub-millisecond periods. If the pulsar wind is collimated by the surrounding environment, the resulting jet can satisfy the power requirements of the highly relativistic outflows from Cir X-1 and Sco X-1. In this framework, the jet power scales relatively weakly with accretion rate, L{sub j}∝ M-dot {sup 4/7}, and would be suppressed at high accretion rates only if the stellar magnetic moment is sufficiently low.

79 ASTRONOMY AND ASTROPHYSICS↗

A NEW DELIVERY ROUTE TO GALACTIC NUCLEI: WARM HALO CLOUD IMPACTS

We propose a new mechanism for the delivery of gas to the heart of galactic nuclei. We show that warm halo clouds (WHCs) must periodically impact galactic centers and potentially deliver a large ({approx}10{sup 4}-10{sup 6} M{sub sun}) mass of gas to the galactic nucleus in a singular event. The impact of an accreting WHC originating far in the galactic halo can, depending on mixing, produce a nuclear starburst of low-metallicity stars as well as low-luminosity accretion onto the central black hole. Based on multiphase cooling around a {Lambda}CDM distribution of halos, we calculate the nuclear impact rate, the mass captured by the central black hole, and the fraction of active nuclei for impacting cloud masses in the range 10{sup 4}-10{sup 6} M{sub sun}. If there is moderate braking during cloud infall, our model predicts an average fraction of low-luminosity active nuclei consistent with observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Mortality and injury assessment for three species of fish exposed to simulated turbine blade strike

Injury and mortality of fish during downstream passage through hydropower turbines is among the leading direct impacts of hydropower. Understanding the relationships among various strike variables and injury and mortality rates are necessary for improvements in turbine design. We subjected three species of fish to simulated blade strike in laboratory studies with different blade thicknesses, impact velocities, and body orientations to develop relationships between these variables and probability of injury and mortality. Midbody strikes resulted in higher mortality than head strikes, and tail strikes produced the least mortality. Lateral strikes caused more mortality than dorsal and ventral strikes, and higher strike velocities and thinner blades contributed to increased mortality. Several injury types were significantly associated with increased mortality, including injuries to the operculum, gills, viscera, heart, liver, swim bladder, muscle, and bone fractures. Here, the results from this study will be used to define biologically based design criteria that can be used by turbine designers to improve designs (e.g., increased leading-edge thickness and slower turbine speeds) to minimize the probability and impact of blade strike.

60 APPLIED LIFE SCIENCES↗

Direct Signal-to-Noise Quality Comparison between an Electronic and Conventional Stethoscope aboard the International Space Station

Introduction: Evaluation of heart, lung, and bowel sounds is routinely performed with the use of a stethoscope to help detect a broad range of medical conditions. Stethoscope acquired information is even more valuable in a resource limited environments such as the International Space Station (ISS) where additional testing is not available. The high ambient noise level aboard the ISS poses a specific challenge to auscultation by stethoscope. An electronic stethoscope's ambient noise‐reduction, greater sound amplification, recording capabilities, and sound visualization software may be an advantage to a conventional stethoscope in this environment. Methods: A single operator rated signal‐to‐noise quality from a conventional stethoscope (Littman 2218BE) and an electronic stethoscope (Litmann 3200). Borborygmi, pulmonic, and cardiac sound quality was ranked with both stethoscopes. Signal‐to‐noise rankings were preformed on a 1 to 10 subjective scale with 1 being inaudible, 6 the expected quality in an emergency department, 8 the expected quality in a clinic, and 10 the clearest possible quality. Testing took place in the Japanese Pressurized Module (JPM), Unity (Node 2), Destiny (US Lab), Tranquility (Node 3), and the Cupola of the International Space Station. All examinations were conducted at a single point in time. Results: The electronic stethoscope's performance ranked higher than the conventional stethoscope for each body sound in all modules tested. The electronic stethoscope's sound quality was rated between 7 and 10 in all modules tested. In comparison, the traditional stethoscope's sound quality was rated between 4 and 7. The signal to noise ratio of borborygmi showed the biggest difference between stethoscopes. In the modules tested, the auscultation of borborygmi was rated between 5 and 7 by the conventional stethoscope and consistently 10 by the electronic stethoscope. Discussion: This stethoscope comparison was limited to a single operator. However, we believe the results are noteworthy. The electronic stethoscope out preformed the traditional stethoscope in each direct comparison. Consideration should be made to incorporate an electronic stethoscope into current and future space vehicle medical kits.

Marshburn, Thomas↗

T-wave alternans negative coronary patients with low ejection and benefit from defibrillator implantation

In a trial of prophylactic implantation of a defibrillator, a mortality benefit was seen among patients with previous myocardial infarction and a left-ventricular ejection fraction of 0.30 or less. We identified 129 similar patients from two previously published clinical trials in which microvolt T-wave alternans testing was prospectively assessed. At 24 months of follow-up, no sudden cardiac death or cardiac arrest was seen among patients who tested T-wave alternans negative, compared with an event rate of 15.6% among the remaining patients. Testing of T-wave alternans seems to identify patients who are at low risk of ventricular tachyarrhythmic event and who may not benefit from defibrillator therapy.

NASA Discipline Cardiopulmonary↗

Metronome Use for Coordination of Breaths and Cardiac Compressions Delivered by Minimally-Trained Caregivers During Two-Person CPR

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training over 18 months before each mission, including two-person cardiopulmonary resuscitation (2CPR) as recommended by the American Heart Association (AHA). Recent studies have concluded that the use of metronomic tones improves the coordination of 2CPR by trained clinicians. 2CPR performance data for minimally-trained caregivers has been limited. The goal of this study was to determine whether use of a metronome by minimally-trained caregivers (CMO analogues) would improve 2CPR performance. 20 pairs of minimally-trained caregivers certified in 2CPR via AHA guidelines performed 2CPR for 4 minutes on an instrumented manikin using 3 interventions: 1) Standard 2CPR without a metronome [NONE], 2) Standard 2CPR plus a metronome for coordinating compression rate only [MET], 3) Standard 2CPR plus a metronome for coordinating both the compression rate and ventilation rate [BOTH]. Caregivers were evaluated for their ability to meet the AHA guideline of 32 breaths-240 compressions in 4 minutes. All (100%) caregivers using the BOTH intervention provided the required number of ventilation breaths as compared with the NONE caregivers (10%) and MET caregivers (0%). For compressions, 97.5% of the BOTH caregivers were not successful in meeting the AHA compression guideline; however, an average of 238 compressions of the desired 240 were completed. None of the caregivers were successful in meeting the compression guideline using the NONE and MET interventions. This study demonstrates that use of metronomic tones by minimally-trained caregivers for coordinating both compressions and breaths improves 2CPR performance. Meeting the breath guideline is important to minimize air entering the stomach, thus decreasing the likelihood of gastric aspiration. These results suggest that manifesting a metronome for the ISS may augment the performance of 2CPR on orbit and thus may increase the level of care.

Hurst, Victor, IV↗

Trapped-ion quantum simulation of electron transfer models with tunable dissipation

Electron transfer is at the heart of many fundamental physical, chemical, and biochemical processes essential for life. The exact simulation of these reactions is often hindered by the large number of degrees of freedom and by the essential role of quantum effects. Here, we experimentally simulate a paradigmatic model of molecular electron transfer using a multispecies trapped-ion crystal, where the donor-acceptor gap, the electronic and vibronic couplings, and the bath relaxation dynamics can all be controlled independently. By manipulating both the ground-state and optical qubits, we observe the real-time dynamics of the spin excitation, measuring the transfer rate in several regimes of adiabaticity and relaxation dynamics. Our results provide a testing ground for increasingly rich models of molecular excitation transfer processes that are relevant for molecular electronics and light-harvesting systems.

Science & Technology - Other Topics↗

Comparison of Bystander Cardiopulmonary Resuscitation (BCPR) Performance in the Absence and Presence of Timing Devices for Coordinating Delivery of Ventilatory Breaths and Cardiac Compressions in a Model of Adult Cardiopulmonary Arrest

Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training during the 18 months preceding each mission. Part of this training ilncludes twoperson cardiopulmonary resuscitation (CPR) per training guidelines from the American Heart Association (AHA). Recent studies concluded that the use of metronomic tones improves the coordination of CPR by trained clinicians. Similar data for bystander or "trained lay people" (e.g. CMO) performance of CPR (BCPR) have been limited. The purpose of this study was to evailuate whether use of timing devices, such as audible metronomic tones, would improve BCPR perfomance by trained bystanders. Twenty pairs of bystanders trained in two-person BCPR performled BCPR for 4 minutes on a simulated cardiopulmonary arrest patient using three interventions: 1) BCPR with no timing devices, 2) BCPR plus metronomic tones for coordinating compression rate only, 3) BCPR with a timing device and metronome for coordinating ventilation and compression rates, respectively. Bystanders were evaluated on their ability to meet international and AHA CPR guidelines. Bystanders failed to provide the recommended number of breaths and number of compressions in the absence of a timing device and in the presence of audible metronomic tones for only coordinating compression rate. Bystanders using timing devices to coordinate both components of BCPR provided the reco number of breaths and were closer to providing the recommended number of compressions compared with the other interventions. Survey results indicated that bystanders preferred to use a metronome for delivery of compressions during BCPR. BCPR performance is improved by timing devices that coordinate both compressions and breaths.

Hurst, Victor, IV↗

Transplantation of CREG modified embryonic stem cells improves cardiac function after myocardial infarction in mice

Engraftment of embryonic stem cells (ESC) has been proposed as a potential therapeutic approach for post-infarction cardiac dysfunction. However, only mild function improvement has been achieved due to low survival rate and paracrine dysfunction of transplanted stem cells. Cellular repressor of E1A stimulated genes (CREG) has been reported to be a secreted glycoprotein implicated in promoting survival and differentiation of many cell types. Therefore we hypothesized that transplantation of genetically modified ESC with CREG (CREG-ESC) can improve cardiac function after myocardial infarction in mice. A total of 2 × 10{sup 5} CREG-ESC or EGFP-ESC were engrafted into the border zone in a myocardial infarction model in mice. Cardiac function, infarct size and fibrosis at 4 weeks, survival of transplanted ESC, apoptosis and cytokine level of heart tissue, and teratoma formation were assessed in vivo. Apoptosis of ESC under inflammatory stimuli and cardiac differentiation of ESC were investigated in vitro. After 4 weeks, we found transplantation of CREG-ESC could significantly improve cardiac function, ameliorate cardiac remodeling, and reduce infarct size and fibrosis area. Transplantation of CREG-ESC remarkably increased ESC survival in the border zone and inhibited apoptosis of cardiomyocytes. Furthermore, the decrease of inflammatory factors (IL-1β, IL-6 and TNF-α) and increase of anti-inflammatory factors (TGF-β, bFGF and VEGF165) in the border zone were higher in CREG-ESC transplanted hearts. Safety evaluation showed that all transplantation at 2 × 10{sup 5} per heart dose produced no teratoma. Surprisingly, the mice with 3.0 × 10{sup 6} CREG-ESC transplantation was demonstrated teratoma free without cardiac rhythm disturbances in contrast to 100% teratoma formation and rhythm abnormality for the same dose of EGFP-ESC transplantation. In addition, overexpression of CREG inhibits ESC apoptosis and enhanced their differentiation into cardiomyocytes in vitro. Transplantation of CREG-modified ESC exhibits a favorable survival pattern in infarcted hearts, which translates into a substantial preservation of cardiac function after acute myocardial infarction.

60 APPLIED LIFE SCIENCES↗

Common marmoset embryonic stem cell can differentiate into cardiomyocytes

Common marmoset monkeys have recently attracted much attention as a primate research model, and are preferred to rhesus and cynomolgus monkeys due to their small bodies, easy handling and efficient breeding. We recently reported the establishment of common marmoset embryonic stem cell (CMESC) lines that could differentiate into three germ layers. Here, we report that our CMESC can also differentiate into cardiomyocytes and investigated their characteristics. After induction, FOG-2 was expressed, followed by GATA4 and Tbx20, then Nkx2.5 and Tbx5. Spontaneous beating could be detected at days 12-15. Immunofluorescent staining and ultrastructural analyses revealed that they possessed characteristics typical of functional cardiomyocytes. They showed sinus node-like action potentials, and the beating rate was augmented by isoproterenol stimulation. The BrdU incorporation assay revealed that CMESC-derived cardiomyocytes retained a high proliferative potential for up to 24 weeks. We believe that CMESC-derived cardiomyocytes will advance preclinical studies in cardiovascular regenerative medicine.

60 APPLIED LIFE SCIENCES↗

Indirect Estimation of Radioactivity in Containerized Cargo

Detecting illicit nuclear and radiological material in containerized cargo challenges the state of the art in detection systems. Current systems are being evaluated and new systems envisioned to address the need for the high probability of detection and extremely low false alarm rates necessary to thwart potential threats and extremely low nuisance and false alarm rates while maintaining necessary to maintain the flow of commerce impacted by the enormous volume of commodities imported in shipping containers. Maintaining flow of commerce also means that primary inspection must be rapid, requiring relatively indirect measurements of cargo from outside the containers. With increasing information content in such indirect measurements, it is natural to ask how the information might be combined to improved detection. Toward this end, we present an approach to estimating isotopic activity of naturally occurring radioactive material in cargo grouped by commodity type, combining container manifest data with radiography and gamma spectroscopy aligned to location along the container. The heart of this approach is our statistical model of gamma counts within peak regions of interest, which captures the effects of background suppression, counting noise, convolution of neighboring cargo contributions, and down-scattered photons to provide physically constrained estimates of counts due to decay of specific radioisotopes in cargo alone. Coupled to that model, we use a mechanistic model of self-attenuated radiation flux to estimate the isotopic activity within cargo, segmented by location within each container, that produces those counts. We demonstrate our approach by applying it to a set of measurements taken at the Port of Seattle in 2006. This approach to synthesizing disparate available data streams and extraction of cargo characteristics holds the potential to improve primary inspection using current detection capabilities and to enable simulation-based evaluation of new candidate detection systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast Diffusion of Ultrarelativistic Electrons in the Outer Radiation Belt: 17 March 2015 Storm Event

Inward radial diffusion driven by ULF waves has long been known to be capable of accelerating radiation belt electrons to very high energies within the heart of the belts, but more recent work has shown that radial diffusion values can be highly event-specific, and mean values or empirical models may not capture the full significance of radial diffusion to acceleration events. Here we present an event of fast inward radial diffusion, occurring during a period following the geomagnetic storm of 17 March 2015. Ultrarelativistic electrons up to ~8 MeV are accelerated in the absence of intense higher-frequency plasma waves, indicating an acceleration event in the core of the outer belt driven primarily or entirely by ULF wave-driven diffusion. We examine this fast diffusion rate along with derived radial diffusion coefficients using particle and fields instruments on the Van Allen Probes spacecraft mission.

79 ASTRONOMY AND ASTROPHYSICS↗

A universal metabolite repair enzyme removes a strong inhibitor of the TCA cycle

Abstract A prevalent side-reaction of succinate dehydrogenase oxidizes malate to enol-oxaloacetate (OAA), a metabolically inactive form of OAA that is a strong inhibitor of succinate dehydrogenase. We purified from cow heart mitochondria an enzyme (OAT1) with OAA tautomerase (OAT) activity that converts enol-OAA to the physiological keto-OAA form, and determined that it belongs to the highly conserved and previously uncharacterized Fumarylacetoacetate_hydrolase_domain-containing protein family. From all three domains of life, heterologously expressed proteins were shown to have strong OAT activity, and ablating the OAT1 homolog caused significant growth defects. In Escherichia coli , expression of succinate dehydrogenase was necessary for OAT1-associated growth defects to occur, and ablating OAT1 caused a significant increase in acetate and other metabolites associated with anaerobic respiration. OAT1 increased the succinate dehydrogenase reaction rate by 35% in in vitro assays with physiological concentrations of both succinate and malate. Our results suggest that OAT1 is a universal metabolite repair enzyme that is required to maximize aerobic respiration efficiency by preventing succinate dehydrogenase inhibition.

59 BASIC BIOLOGICAL SCIENCES↗

Test Bed for Investigating Anomalous Pump Behavior in a Single Phase Mechanically Pumped Flow Loop and Lessons Learned

NASA’s Europa Clipper mission is tasked with investigating the habitability of this icy moon of Jupiter and determining if it is capable of supporting life. The suite of powerful instruments necessary for this mission, combined with the harsh environment, require an elaborate single phase, mechanically pumped flow loop (MPFL) to redistribute waste heat around the spacecraft, thus minimizing energy requirements and avoiding the need for constant heating of the propulsion tanks. At the heart of this MPFL is a pump which will circulate fluid for the entirety of the 12-year mission; however, during initial qualification testing, anomalous behavior raised serious concerns regarding the pump and system design. Due to the critical nature of the pump, a major investigation was launched to evaluate the pump, system design, and the testing methodology employed to investigate this anomaly. This investigation resulted in a highly detailed analysis of the test loop, revised procedures, and the isolation/removal of variables impacting the quality of the observed pump behavior. The resulting test loop permitted comprehensive monitoring of the pump in the MPFL, including: flow rate, inlet and outlet static pressures, temperature, power consumption, and pump speed. Additionally, the investigation of the anomaly revealed several key lessons learned and helped institute a new set of best practices for future MPFL tests.

Miers, Collier↗

Early-Stage Breast Cancer Treated With 3-Week Accelerated Whole-Breast Radiation Therapy and Concomitant Boost

Purpose: To report early outcomes of accelerated whole-breast radiation therapy with concomitant boost. Methods and Materials: This is a prospective, institutional review board-approved study. Eligibility included stage TisN0, T1N0, and T2N0 breast cancer. Patients receiving adjuvant chemotherapy were ineligible. The whole breast received 40.5 Gy in 2.7-Gy fractions with a concomitant lumpectomy boost of 4.5 Gy in 0.3-Gy fractions. Total dose to the lumpectomy site was 45 Gy in 15 fractions over 19 days. Results: Between October 2004 and December 2010, 160 patients were treated; stage distribution was as follows: TisN0, n=63; T1N0, n=88; and T2N0, n=9. With a median follow-up of 3.5 years (range, 1.5-7.8 years) the 5-year overall survival and disease-free survival rates were 90% (95% confidence interval [CI] 0.84-0.94) and 97% (95% CI 0.93-0.99), respectively. Five-year local relapse-free survival was 99% (95% CI 0.96-0.99). Acute National Cancer Institute/Common Toxicity Criteria grade 1 and 2 skin toxicity was observed in 70% and 5%, respectively. Among the patients with ≥2-year follow-up no toxicity higher than grade 2 on the Late Effects in Normal Tissues–Subjective, Objective, Management, and Analytic scale was observed. Review of the radiation therapy dose–volume histogram noted that ≥95% of the prescribed dose encompassed the lumpectomy target volume in >95% of plans. The median dose received by the heart D{sub 05} was 215 cGy, and median lung V{sub 20} was 7.6%. Conclusions: The prescribed accelerated schedule of whole-breast radiation therapy with concomitant boost can be administered, achieving acceptable dose distribution. With follow-up to date, the results are encouraging and suggest minimal side effects and excellent local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy for Early Mediastinal Hodgkin Lymphoma According to the German Hodgkin Study Group (GHSG): The Roles of Intensity-Modulated Radiotherapy and Involved-Node Radiotherapy

Purpose: Cure rates of early Hodgkin lymphoma (HL) are high, and avoidance of late complications and second malignancies have become increasingly important. This comparative treatment planning study analyzes to what extent target volume reduction to involved-node (IN) and intensity-modulated (IM) radiotherapy (RT), compared with involved-field (IF) and three-dimensional (3D) RT, can reduce doses to organs at risk (OAR). Methods and Materials: Based on 20 computed tomography (CT) datasets of patients with early unfavorable mediastinal HL, we created treatment plans for 3D-RT and IMRT for both the IF and IN according to the guidelines of the German Hodgkin Study Group (GHSG). As OAR, we defined heart, lung, breasts, and spinal cord. Dose-volume histograms (DVHs) were evaluated for planning target volumes (PTVs) and OAR. Results: Average IF-PTV and IN-PTV were 1705 cm{sup 3} and 1015 cm{sup 3}, respectively. Mean doses to the PTVs were almost identical for all plans. For IF-PTV/IN-PTV, conformity was better with IMRT and homogeneity was better with 3D-RT. Mean doses to the heart (17.94/9.19 Gy for 3D-RT and 13.76/7.42 Gy for IMRT) and spinal cord (23.93/13.78 Gy for 3D-RT and 19.16/11.55 Gy for IMRT) were reduced by IMRT, whereas mean doses to lung (10.62/8.57 Gy for 3D-RT and 12.77/9.64 Gy for IMRT) and breasts (left 4.37/3.42 Gy for 3D-RT and 6.04/4.59 Gy for IMRT, and right 2.30/1.63 Gy for 3D-RT and 5.37/3.53 Gy for IMRT) were increased. Volume exposed to high doses was smaller for IMRT, whereas volume exposed to low doses was smaller for 3D-RT. Pronounced benefits of IMRT were observed for patients with lymph nodes anterior to the heart. IN-RT achieved substantially better values than IF-RT for almost all OAR parameters, i.e., dose reduction of 20% to 50%, regardless of radiation technique. Conclusions: Reduction of target volume to IN most effectively improves OAR sparing, but is still considered investigational. For the time being, IMRT should be considered for large PTVs especially when the anterior mediastinum is involved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanisms of a novel regulatory light chain–dependent cardiac myosin inhibitor

Hypertrophic cardiomyopathy (HCM) is a genetic disease of the heart characterized by thickening of the left ventricle (LV), hypercontractility, and impaired relaxation. HCM is caused primarily by heritable mutations in sarcomeric proteins, such as β myosin heavy chain. Until recently, medications in clinical use for HCM did not directly target the underlying contractile changes in the sarcomere. Here, we investigate a novel small molecule, RLC-1, identified in a bovine cardiac myofibril high-throughput screen. RLC-1 is highly dependent on the presence of a regulatory light chain to bind to cardiac myosin and modulate its ATPase activity. In demembranated rat LV trabeculae, RLC-1 decreased maximal Ca2+-activated force and Ca2+ sensitivity of force, while it increased the submaximal rate constant for tension redevelopment. In myofibrils isolated from rat LV, both maximal and submaximal Ca2+-activated force are reduced by nearly 50%. Additionally, the fast and slow phases of relaxation were approximately twice as fast as DMSO controls, and the duration of the slow phase was shorter. Structurally, x-ray diffraction studies showed that RLC-1 moved myosin heads away from the thick filament backbone and decreased the order of myosin heads, which is different from other myosin inhibitors. In intact trabeculae and isolated cardiomyocytes, RLC-1 treatment resulted in decreased peak twitch magnitude and faster activation and relaxation kinetics. In conclusion, RLC-1 accelerated kinetics and decreased force production in the demembranated tissue, intact tissue, and intact whole cells, resulting in a smaller cardiac twitch, which could improve the underlying contractile changes associated with HCM.

Physiology↗