Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hazard Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Semitransparent curtains for control of optical radiation hazards

The purposes and functions of semitransparent eye protective curtains are analyzed. Based upon this analysis, functional requirements are developed, and design requirements are specified for optimum curtains to be used with open arc welding and arc cutting processes. Such curtains also protect against other high intensity broad-spectral-band sources such as compact arc lamps. The requirements for filtering out hazardous UV radiation and blue light must be balanced against the need for transparency in the visible spectrum and the need for reduced glare. Infrared attenuation is shown to be of very little importance.

Sliney, D. H.↗

Guidance on Hazard and Safety Analyses of LPG Spills on Water

In 2004, at the request of the Department of Energy, Sandia National Laboratories (Sandia) prepared a report, "Guidance on the Risk and Safety Analysis of Large Liquefied Natural Gas (LNG) Spills Over Water". That report provided a framework for assessing hazards and identifying approaches to minimize the consequences to people and property from an LNG spill over water. Because of increasing domestic U.S. supplies of natural gas and associated by products, such as liquefied propane gas (LPG), the United states Coast Guard requested that Sandia assess the general scale of possible hazards for a breach and spill of an LPG carrier. Because of the broad range of LPG carriers types -- refrigerated and pressurized, ships and barges, Sandia chose to focus this analysis on the larger LPG refrigerated systems. With cargo capacities ranging up to 100,000 m 3 , these types of ships can be expected to support potential increased LPG exports. Sandia assessed potential accidental and intentional threats, and based on LPG carrier configurations and designs, estimated potential breach sizes, spill rates and volumes, and conducted fire, vapor dispersion, and detonation hazard analyses. This report summarizes the analyses conducted, the expected range of potential hazards from an associated refrigerated LPG carrier spill over water, and risk management approaches to minimize consequences to people and property from such a spill.

03 NATURAL GAS↗

Exploring Uncertainty in Moment Estimation for Small Earthquakes in Southern Nevada Using the Coda Envelope Method

Compiling source parameter estimates for small earthquakes is important both for our understanding of earthquake physics and for accurately assessing earthquake hazard. Reliable source parameter estimates are difficult to achieve for small earthquakes, in part due to our inability to accurately model the relevant physical processes at high frequencies. The coda envelope methodology developed by Mayeda and Walter (1996) and Mayeda et al. (2003) can mitigate this concern and estimate the moment of small earthquakes by determining the parameters that control the shape of the S-wave coda envelope while eliminating path effects by minimizing the scatter between seismic stations. Here, we use an open-source implementation of this technique called the Coda Calibration Tool (CCT; Barno, 2017) to calculate CCT-based moment magnitude estimates of small earthquakes (M L 0–3) in the Rock Valley, Nevada, region within the Nevada National Security Site. The Rock Valley data set is of particular interest because it allows us to explore the changes in uncertainties of the coda calibration method with earthquake size and depth. We found that a consistent linear relationship exists between the local magnitude M L and our coda-derived M w estimates for earthquakes as small as M L 0–3, but that current CCT workflows do not accurately characterize very shallow events. We also demonstrate that the epistemic uncertainty in the apparent stress value assumed by the CCT algorithm can influence magnitude estimates of small earthquakes. In conclusion, these results provide valuable insight into the seismicity of this region, and inform future analysis and modeling efforts for nuclear monitoring and seismic hazard.

58 GEOSCIENCES↗

Monte Carlo based beam model using a photon MLC for modulated electron radiotherapy

Purpose: Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). Methods: This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. Results: For 15 × 34, 5 × 5, and 2 × 2 cm{sup 2} fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. Conclusions : The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-dependent behavioral data from zebrafish reveals novel signatures of chemical toxicity using point of departure analysis

High-content imaging of embryonic zebrafish behavior can be used as a screening approach to rapidly evaluate the relative potential for chemicals to cause toxicity. However, most statistical methods applied to these data so far transform movement values to incidence-based “hits” and calculate lowest effect levels (LELs), which loses individual fish resolution of behavior and defies hazard ranking due to reliance on applied dose levels. Here, we have developed and parallelized a workflow to calculate benchmark dose (BMD) values from dynamic, high-content zebrafish behavior data that scales for high-throughput chemical screening. To appropriately capture the dynamics of zebrafish response from light to dark stimulus, we summarized time-dependent data using both area under the curve and immediate change at the transition point into two novel metrics that characterized abnormal behavior as a function of chemical concentration. The BMD workflow was applied to calculate BMD 10 values of 1,060 ToxCast chemicals for 24 zebrafish endpoints, including behavior, mortality and morphology. The BMD 10 values provided better precision and separation than LELs for clustering chemicals since they were derived from models that best-fit their concentration-response curves. Clustering analysis revealed behavioral signatures as the most sensitive endpoints. High concordance in chemical activity was observed between ToxCast assays and zebrafish behavioral endpoints, however ToxPi analysis indicated that rankings based on in vitro data was not a reliable predictor of in vivo rankings for lower potency chemicals. The methods developed in this work will enable the use of high-content zebrafish behavioral screening data for BMD analysis in toxicological hazard assessment.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Assessment of Detection Frequency for the INL Ambient Air Monitoring Network

A quantitative assessment of the Idaho National Laboratory (INL) air monitoring network was performed using frequency of detection as the performance metric. The INL air monitoring network consists of 37 low-volume air samplers in 31 different locations. Twenty of the samplers are located on INL (onsite) and 17 are located off INL (offsite). Detection frequencies were calculated using both BEA and ESER laboratory minimum detectable activity (MDA) levels. The CALPUFF Lagrangian puff dispersion model, coupled with 1 year of meteorological data, was used to calculate time-integrated concentrations at sampler locations for a 1-hour release of unit activity (1 Ci) for every hour of the year. The unit-activity time-integrated concentration (TICu) values were calculated at all samplers for releases from eight INL facilities. The TICu values were then scaled and integrated for a given release quantity and release duration. All facilities modeled a ground-level release emanating either from the center of the facility or at a point where significant emissions are possible. In addition to ground-level releases, three existing stacks at the Advanced Test Reactor Complex, Idaho Nuclear Technology and Engineering Center, and Material and Fuels Complex were also modeled. Meteorological data from the 35 stations comprising the INL Mesonet network, data from the Idaho Falls Regional airport, upper air data from the Boise airport, and three-dimensional gridded data from the weather research forecasting model were used for modeling. Three representative radionuclides identified as key radionuclides in INL’s annual National Emission Standards for Hazardous Air Pollutants evaluations were considered for the frequency of detection analysis: Cs-137 (beta-gamma emitter), Pu-239 (alpha emitter), and Sr-90 (beta emitter). Source-specific release quantities were calculated for each radionuclide, such that the maximum inhalation dose at any publicly accessible sampler or the National Emission Standards for Hazardous Air Pollutants maximum exposed individual location (i.e., Frenchman’s Cabin) was no more than 0.1 mrem yr–1 (i.e., 1% of the 10 mrem yr–1 standard). Detection frequencies were calculated separately for the onsite and offsite monitoring network. As expected, detection frequencies were generally less for the offsite sampling network compared to the onsite network. Overall, the monitoring network is very effective at detecting the potential releases of Cs-137 or Sr-90 from all sources/facilities using either the ESER or BEA MDAs. The network was less effective at detecting releases of Pu-239. Maximum detection frequencies for Pu-239 using ESER MDAs ranged from 27.4 to 100% for onsite samplers and 3 to 80% for offsite samplers. Using BEA MDAs, the maximum detection frequencies for Pu-239 ranged from 2.1 to 100% for onsite samplers and 0 to 5.9% for offsite samplers. The only release that was not detected by any of the samplers under any conditions was a release of Pu-239 from the Idaho Nuclear Technology and Engineering Center main stack (CPP-708). The methodology described in this report could be used to improve sampler placement and detection frequency, provided clear performance objectives are defined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural Characterization of a Toppling Rock Slab From Array-Based Ambient Vibration Measurements and Numerical Modal Analysis

Accurate assessments of the internal structure and boundary conditions of unstable rock slopes are imperative for evaluating landslide hazard scenarios. However, instability characterization at depth remains challenging and is often limited by costly or invasive subsurface investigations. Here, we develop a new approach coupling array-based ambient vibration modal analysis and numerical modeling to improve structural characterization of rock slope instabilities at depth. We used ambient noise cross-correlation on 4 hr of seismic data recorded by an array of 30 nodal geophones at a 500-m-long toppling rock slab in Utah, USA to identify modal frequencies between 0.8 and 3.5 Hz and derive modal displacements. We show that transverse and longitudinal bending modes span the length of the instability, indicating an interconnected slab. Further, statistical comparison of field results with outputs from >1,000 finite element models with varying boundary conditions showed that the instability depth varies between 40–70 and 10–20 m in the middle and lateral regions, respectively. Our approach yields new information on the structural conditions of rock cliff and column instabilities at depth, which is not easily obtained by other means but is imperative for change detection monitoring and improved hazard assessments.

58 GEOSCIENCES↗

Framework for Real-Time All-Hazards Global Situational Awareness

Information systems play a pivotal role in emergency response by making consequence analysis models based on up-to-date data available to decision makers. While consequence analysis models have been used for years on local scales, their application on national and global scales has been constrained by lack of non-proprietary data. This chapter describes how this has changed using a framework for real-time all-hazards situational awareness called the Energy Awareness and Resiliency Standardized Services (EARSS) as an example. EARSS is a system of systems developed to collect non-proprietary data from diverse open content sources to develop a geodatabase of critical infrastructures all over the world. The EARSS system shows that it is feasible to provide global disaster alerts by producing valuable information such as texting messages about detected hazards, emailing reports about affected areas, estimating an expected number of impacted people and their demographic characteristics, identifying critical infrastructures that may be affected, and analyzing potential downstream effects. This information is provided in real-time to federal agencies and subscribers all over the world for decision making in humanitarian assistance and emergency response. The system also uses live streams of power outages, weather, and satellite surveillance data as events unfold. This, in turn, is combined with other public domain or open content information, such as media reports and postings on social networking websites, for complete coverage of the situation as events unfold. Working with up-to-date information from the EARSS system, emergency responders on the ground could pre-position their staff and resources, such as emergency generators and ice, where they are most needed.

disaster consequence management↗

The Impact of Intensity Modulated Radiation Therapy on Hospitalization Outcomes in the SEER-Medicare Population With Anal Squamous Cell Carcinoma

Purpose: We examined the impact of intensity modulated radiation therapy (IMRT) on hospitalization rates in the Surveillance, Epidemiology, and End Results (SEER)–Medicare population with anal squamous cell carcinoma (SCC). Methods and Materials: We performed a retrospective cohort study using the SEER-Medicare database. We identified patients with nonmetastatic anal SCC diagnosed between 2001 and 2011 and treated with chemoradiation therapy. We assessed the relation between IMRT and first hospitalization by use of a multivariate competing-risk model, as well as instrumental variable analysis, using provider IMRT affinity as our instrument. Results: Of the 1165 patients included in our study, 458 (39%) received IMRT. IMRT use increased over time and was associated more with regional and provider characteristics than with patient characteristics. The 3- and 6-month cumulative incidences of first hospitalization were 41.9% (95% confidence interval [CI], 37.3%-46.4%) and 47.6% (95% CI, 43.0%-52.2%), respectively, for the IMRT cohort and 46.7% (95% CI, 43.0%-50.4%) and 52.1% (95% CI, 48.4%-55.7%), respectively, for the non-IMRT cohort. IMRT was associated with a decreased hazard of first hospitalization compared with 3-dimensional radiation techniques (hazard ratio, 0.70; 95% CI, 0.58-0.84; P=.0002). Instrumental variable analysis suggested an even greater reduction in hospitalizations with IMRT after controlling for unmeasured confounders. There was a trend toward improved overall survival with IMRT, with an adjusted hazard ratio of 0.77 (95% CI, 0.59-1.00; P=.05). Conclusions: The use of IMRT is associated with reduced hospitalizations in elderly patients with anal SCC. Further work is warranted to understand the long-term health and cost impact of IMRT, particularly for patient subgroups most at risk of toxicity and hospitalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a contaminated facility and associated soils in support of D and D and subsequent soil remediation - 15292

Before starting any D and D field work at a United States Department of Energy (DOE) facility such as the Savannah River Site (SRS), it is recommended that a complete review and understanding of the full nature and extent of any contamination located in or previously associated with that facility is known. An integral aspect of this review and research entails a complete characterization of that facility, including, but not limited to, Toxic Substances Control Act (TSCA) limits for Polychlorinated Biphenyl (PCB), radiological, Resource Conservation and Recovery Act of 1976 (RCRA) and other hazardous chemicals, etc. A thorough characterization of a facility and its underlying soils supports: - establishment of safe working conditions to protect human health and environment - Deactivation and Decommissioning (D and D) methodology - cost estimates to support future budget planning for D and D and soil cleanup A prime example of this is documented in the characterization of the 690-N, Process Heat Exchanger Repair Facility that had a history of PCB and radioactive contamination. Characterization of 690-N included the sampling and analysis of concrete and underlying soils for radiological, PCB and hazardous contaminants. In addition, a sump, the walls of the facility, expansion joint material and the metal base of a drill press were characterized. Results of this comprehensive characterization of the 690-N Building are provided in a detailed report. Analytical results indicate minimal radiological, PCB, or RCRA hazardous contamination is present in the concrete floor slab (industrial exposure levels) and on the steel hut walls. Soils below the concrete floor slab show only trace amounts of radiological contamination and are well below TSCA and RCRA limits. Subsequent decommissioning/demolition activities can be performed safely without harming people or the environment, and cost estimates to perform building demolition can be developed for future budget planning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estrogen/Progesterone Receptor Negativity and HER2 Positivity Predict Locoregional Recurrence in Patients With T1a,bN0 Breast Cancer

Purpose: Data have suggested that the molecular features of breast cancer are important determinants of outcome; however, few studies have correlated these features with locoregional recurrence (LRR). In the present study, we evaluated estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) as predictors of LRR in patients with lymph node-negative disease and tumors {<=}1 cm, because these patients often do not receive adjuvant chemotherapy or trastuzumab. Methods and Materials: The data from 911 patients with stage T1a,bN0 breast cancer who had received definitive treatment at our institution between 1997 and 2002 were retrospectively reviewed. We prospectively analyzed ER/PR/HER2 expression from the archival tissue blocks of 756 patients. These 756 patients represented the cohort for the present study. Results: With a median follow-up of 6.0 years, the 5- and 8-year Kaplan-Meier LRR rate was 1.6% and 5.9%, respectively, with no difference noted in those who underwent breast conservation therapy vs. mastectomy (p = .347). The 8-year LRR rates were greater in the patients with ER-negative (10.6% vs. 4.2%, p = .016), PR-negative (9.0% vs. 4.2%, p = .009), or HER2-positive (17.5% vs. 3.9%, p = 0.009) tumors. On multivariate analysis, ER-negative and PR-negative disease (hazard ratio, 2.37; p = .046) and HER2-positive disease (hazard ratio, 3.13, p = .016) independently predicted for LRR. Conclusion: Patients with ER/PR-negative or HER2-positive T1a,bN0 breast cancer had a greater risk of LRR. Therapeutic strategies, such as the use of chemotherapy and/or anti-HER2 therapies, should be considered for future clinical trials for these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Factors in Stereotactic Body Radiotherapy for Non-Small-Cell Lung Cancer

Purpose: To investigate the factors that influence clinical outcomes after stereotactic body radiotherapy (SBRT) for non-small-cell lung cancer (NSCLC). Methods and Materials: A total of 101 consecutive patients who underwent SBRT with 48 Gy in 4 fractions for histologically confirmed Stage I NSCLC were enrolled in this study. Factors including age, maximal tumor diameter, sex, performance status, operability, histology, and overall treatment time were evaluated with regard to local progression (LP), disease progression (DP), and overall survival (OS) using the Cox proportional hazards model. Prognostic models were built with recursive partitioning analysis. Results: Three-year OS was 58.6% with a median follow-up of 31.4 months. Cumulative incidence rates of LP and DP were 13.2% and 40.8% at 3 years, respectively. Multivariate analysis demonstrated that tumor diameter was a significant factor in all endpoints of LP, DP, and OS. Other significant factors were age in DP and sex in OS. Recursive partitioning analysis indicated a condition for good prognosis (Class I) as follows: female or T1a (tumor diameter {<=}20 mm). When the remaining male patients with T1b-2a (>20 mm) were defined as Class II, 3-year LP, DP, and OS were 6.8%, 23.6%, and 69.9% in recursive partitioning analysis Class I, respectively, whereas these values were 19.9%, 58.3%, and 47.1% in Class II. The differences between the classes were statistically significant. Conclusions: Tumor diameter and sex were the most significant factors in SBRT for NSCLC. T1a or female patients had good prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Turbo FRMAC 2021 v.11.0.0

The Turbo FRMAC analysis tool performs complex calculations to quickly evaluate radiological hazards during an emergency response by assessing impacts to the public, workers, and the food supply. Turbo FRMAC can be used to evaluate the hazard from a wide variety of radiological incidents. Turbo FRMAC calculations are based on methods established by the Federal Radiological Monitoring and Assessment (FRMAC). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10713 O

Whitener, Dustin↗

Essential Function Analysis Capability

The Essential Function Analysis Capability (EFAC) is an extension of the All Hazards Knowledge Framework (AHA) and is a dynamic analytical framework that enables critical infrastructure knowledge discovery and decision support across the five mission areas – prevention, protection, mitigation, response and recovery. EFAC provides the ability to store and model infrastructure systems as a linked multigraphs providing an intuitive and natural representation. These infrastructure systems can then be tied to the organizational and essential function breakdown of an entity. This capability provides the foundation to rapidly evaluate and understand the potential consequences of manmade and natural disaster on these infrastructure systems and essential functions.

Hoover, MichaelJ.↗

Safety considerations in the design and operation of large wind turbines

The engineering and safety techniques used to assure the reliable and safe operation of large wind turbine generators utilizing the Mod 2 Wind Turbine System Program as an example is described. The techniques involve a careful definition of the wind turbine's natural and operating environments, use of proven structural design criteria and analysis techniques, an evaluation of potential failure modes and hazards, and use of a fail safe and redundant component engineering philosophy. The role of an effective quality assurance program, tailored to specific hardware criticality, and the checkout and validation program developed to assure system integrity are described.

Reilly, D. H.↗

Achieving safe autonomous landings on Mars using vision-based approaches

Autonomous landing capabilities will be critical to the success of planetary exploration missions, and in particular to the exploration of Mars. Past studies have indicated that the probability of failure associated with open-loop landings is unacceptably high. Two approaches to achieving autonomous landings with higher probabilities of success are currently under analysis. If a landing site has been certified as hazard free, then navigational aids can be used to facilitate a precision landing. When only limited surface knowledge is available and landing areas cannot be certified as hazard free, then a hazard detection and avoidance approach can be used, in which the vehicle selects hazard free landing sites in real-time during its descent. Issues pertinent to both approaches, including sensors and algorithms, are presented. Preliminary results indicate that one promising approach to achieving high accuracy precision landing is to correlate optical images of the terrain acquired during the terminal descent phase with a reference image. For hazard detection scenarios, a sensor suite comprised of a passive intensity sensor and a laser ranging sensor appears promising as a means of achieving robust landings.

Pien, Homer↗

Advanced Environmental Monitoring and Control Program: Strategic Plan

Human missions in space, from short-duration shuttle missions lasting no more than several days to the medium-to-long-duration missions planned for the International Space Station, face a number of hazards that must be understood and mitigated for the mission to be carried out safely. Among these hazards are those posed by the internal environment of the spacecraft itself; through outgassing of toxic vapors from plastics and other items, failures or off-nominal operations of spacecraft environmental control systems, accidental exposure to hazardous compounds used in experiments: all present potential hazards that while small, may accumulate and pose a danger to crew health. The first step toward mitigating the dangers of these hazards is understanding the internal environment of the spacecraft and the compounds contained within it. Future spacecraft will have integrated networks of redundant sensors which will not only inform the crew of hazards, but will pinpoint the problem location and, through analysis by intelligent systems, recommend and even implement a course of action to stop the problem. This strategic plan details strategies to determine NASA's requirements for environmental monitoring and control systems for future spacecraft, and goals and objectives for a program to answer these needs.

Schmidt, Gregory↗

Dynamic wake prediction and visualization with uncertainty analysis

A dynamic wake avoidance system utilizes aircraft and atmospheric parameters readily available in flight to model and predict airborne wake vortices in real time. A novel combination of algorithms allows for a relatively simple yet robust wake model to be constructed based on information extracted from a broadcast. The system predicts the location and movement of the wake based on the nominal wake model and correspondingly performs an uncertainty analysis on the wake model to determine a wake hazard zone (no fly zone), which comprises a plurality of wake planes, each moving independently from another. The system selectively adjusts dimensions of each wake plane to minimize spatial and temporal uncertainty, thereby ensuring that the actual wake is within the wake hazard zone. The predicted wake hazard zone is communicated in real time directly to a user via a realistic visual representation. In an example, the wake hazard zone is visualized on a 3-D flight deck display to enable a pilot to visualize or see a neighboring aircraft as well as its wake. The system substantially enhances the pilot's situational awareness and allows for a further safe decrease in spacing, which could alleviate airport and airspace congestion.

Holforty, Wendy L.↗