Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIGH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Strontium and barium iodide high light yield scintillators

Europium-doped strontium and barium iodide are found to be readily growable by the Bridgman method and to produce high scintillation light yields. SrI{sub 2}(Eu) emits into the Eu{sup 2+} band, centered at 435 nm, with a decay time of 1.2 {mu}s and a light yield of {approx}90 000 photons/MeV. It offers energy resolution better than 4% full width at half maximum at 662 keV, and exhibits excellent light yield proportionality. BaI{sub 2}(Eu) produces >30 000 photons/MeV into the Eu{sup 2+} band at 420 nm (<1 {mu}s decay). An additional broad impurity-mediated recombination band is present at 550 nm (>3 {mu}s decay), unless high-purity feedstock is used.

36 MATERIALS SCIENCE↗

A high-resolution coherent transition radiation diagnostic for laser-produced electron transport studies (invited)

High-resolution images of the rear-surface optical emission from high-intensity (I{approx}10{sup 19} W/cm{sup 2}) laser illuminated metal foils have been recorded using coherent transition radiation (CTR). CTR is generated as relativistic electrons, generated in high-intensity laser-plasma interactions, exit the target's rear surface and move into vacuum. A transition radiation diagnostic (TRD) records time-integrated images in a 24 nm bandwidth window around {lambda}=529 nm. The optical transmission at {lambda}=1053 nm, the laser wavelength, is 15 orders of magnitude lower than the transmission at the wavelength of interest, {lambda}=527 nm. The detector is a scientific grade charge-coupled device (CCD) camera that operates with a signal-to-noise ratio of 10{sup 3} and has a dynamic range of 10{sup 4}. The TRD has demonstrated a spatial resolution of 1.4 {mu}m over a 1 mm field of view, limited only by the CCD pixel size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new large radius imaging plate camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by multiexposure method

A new large radius imaging plate diffraction camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by means of multiple exposures has been developed for an insertion device beamline of SPring-8, Japan. The new imaging plate camera consists of a large radius cylindrical shape imaging plate cassette that is 400 mm in length and 954.9 mm in cylinder radius. The cassette is designed to be mounted on the 2{theta} arm of the diffractometer of BL15XU in SPring-8. One imaging plate covers 24 deg. and several times of exposure changing the 2{theta}-setting angle is necessary to obtain whole powder diffraction data up to a high angle region. One pixel of the imaging plate corresponds to 0.003 deg. in 2{theta} when the readout pixel size is 50 {mu}m squares. Separately collected data are translated to 2{theta}-intensity format and are connected by comparing the peak and background intensity included in the overlapped area. The exposure time is less than 120 s for most samples and the readout time is about 3 min; thus, the total measurement time for one powder diffraction pattern is less than 20 min. The measurement time is the same order as the continuous 2{theta}-scanning method of the third generation synchrotron powder diffractometer. The angular resolution of the new imaging plate camera was evaluated by comparing the full width at half maximum of the 111 reflection of NBS-Si. The observed angular resolution is not so high as a powder diffractometer with a Si or a Ge analyzer monochromator in the third generation synchrotron facility but higher than a powder diffractometer with a Ge analyzer monochromator at a bending magnet beamline of the second generation synchrotron. The Rietveld analysis of NBS-CeO{sub 2} was successfully carried out with the data taken by the new imaging plate camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High rate synthesis of crystalline silicon films from SiH{sub 4}+He using high density microwave plasma

By using a high density microwave-induced plasma source, depositions of crystalline silicon films from SiH{sub 4}+He mixture are investigated systematically. Microwave power and SiH{sub 4} flow rate are used as the variable deposition parameters. Results demonstrate that film deposition rate increases with increasing both the microwave power and the SiH{sub 4} flow rate. While film crystallinity promotes with increasing the microwave power but degrades with increasing the SiH{sub 4} flow rate. After optimizing the film deposition conditions, highly crystallized Si films are deposited at a rate higher than 1000 nm/s. Promotion of the dissociation efficiency of source gases and enhancement in the diffusion length of film precursors on growing surface are suggested to be main factors responsible for the simultaneous achievements of the high deposition rate and the high film crystallinity. Mechanisms under these phenomena are discussed in detail.

36 MATERIALS SCIENCE↗

In situ high energy x-ray synchrotron diffraction study of the synthesis and stoichiometry of LaFeAsO and LaFeAsO[subscript 1-x] F[subscript y]

The reaction path for the synthesis of LaFeAsO and LaFeAsO{sub 1-x}F{sub y} by solid state reaction was studied by in situ high temperature x-ray diffraction technique and differential thermal analysis in the temperature interval 100 C - T - 1150 C. Starting with LaAs, Fe{sub 2}O{sub 3}, Fe, and LaF{sub 3} as precursors, the results show that the synthesis is characterized by three temperature intervals: (1) Below 500 C the sequential reduction of Fe{sub 2}O{sub 3} and Fe{sub 3}O{sub 4} takes place through the oxidization of LaAs. Below 400 C, Fe{sub 2}O{sub 3} is reduced to Fe{sub 3}O{sub 4} by LaAs and then at 400 C < T < 500 C Fe{sub 3}O{sub 4} is further reduced to Fe. (2) In the temperature interval 500 C < T < 800 C, multiple intermediate reactions take place resulting in the formation of FeAs and La{sub 2}O{sub 3}. (3) The formation of LaFeAsO based phase could be unambiguously resolved above 800 C. For both LaFeAsO and LaFeAsO{sub 1-x}F{sub y}, FeAs is a primary impurity at high temperatures that melts at {approx} 1040 C. Possible reaction pathways and the difference between F-free and F-doped samples are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Seeman–Bohlin geometry for high-resolution nanosecond x-ray diffraction measurements from shocked polycrystalline and amorphous materials [Shock compression measurement in a Seeman-Bohlin camera geometry developed for time-resolved x-ray diffraction studies of shocked polycrystalline and amorphous materials]

Here, we report on a focusing x-ray diffraction geometry capable of high-resolution in situ lattice probing from dynamically loaded polycrystalline and amorphous materials. The Seeman–Bohlin-type camera presented here is ideally suited for time-resolved x-ray diffraction measurements performed on high energy multibeam laser platforms. Diffraction from several lattice planes of ablatively shock-loaded 25 μm thick Cu foils was recorded on a focusing circle of diameter D=100 mm with exceptional angular resolution limited only by the spectral broadening of the x-ray source. Excellent agreement was found between the density measured using x-ray diffraction and that inferred from Doppler velocimetry and the known shock Hugoniot of Cu. In addition, x-ray diffraction signal was captured from an amorphous material under static conditions.

36 MATERIALS SCIENCE↗

A portable high-field pulsed-magnet system for single-crystal x-ray scattering studies

We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields ({approx}1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Activities on Realization of High-Power and Steady-State ECRH System and Achievement of High Performance Plasmas in LHD

Electron Cyclotron Resonance Heating (ECRH) has contributed to the achievement of high performance plasma production, high electron temperature plasmas and sustainment of steady-state plasmas in the Large Helical Device (LHD). Our immediate targets of upgrading the ECRH system are 5 MW several seconds and 1 MW longer than one hour power injection into LHD. The improvement will greatly extend the plasma parameter regime. For that purpose, we have been promoting the development and installation of 77 GHz/1-1.5 MW/several seconds and 0.3 MW/CW gyrotrons in collaboration with University of Tsukuba. The transmission lines are re-examined and improved for high and CW power transmission. In the recent experimental campaign, two 77 GHz gyrotrons were operated. One more gyrotron, which was designed for 1.5 MW/2 s output, was constructed and is tested. We have been promoting to improve total ECRH efficiency for efficient gyrotron-power use and efficient plasma heating, e.g. a new waveguide alignment method and mode-content analysis and the feedback control of the injection polarization. In the last experimental campaign, the 77 GHz gyrotrons were used in combination with the existing 84 GHz range and 168 GHz gyrotrons. Multi-frequency ECRH system is more flexible in plasma heating experiments and diagnostics. A lot of experiments have been performed in relation to high electron temperature plasmas by realization of the core electron-root confinement (CERC), electron cyclotron current drive (ECCD), Electron Bernstein Wave heating, and steady-state plasma sustainment. Some of the experimental results are briefly described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

43 PARTICLE ACCELERATORS↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure and initial growth characteristics of nanocrystalline silicon films fabricated by very high frequency plasma enhanced chemical vapor deposition with highly H{sub 2} dilution of SiH{sub 4}

Nanocrystalline silicon (nc-Si:H) film deposited on silicon oxide in a very high frequency plasma enhanced chemical vapor deposition with highly H{sub 2} dilution of SiH{sub 4} has been investigated by Raman spectroscopy and high resolution transmission electron microscopy. It is found that at early growth stage the initial amorphous incubation layer in nc-Si:H growth on silicon oxide can be almost eliminated and crystallites with diameter of about 6 to 10 nm are directly formed on the silicon oxide. Nearly parallel columnar structures with complex microstructure are found from cross-sectional transmission electron microscopy images of the film. It is considered that highly H{sub 2} dilution and higher excitation frequency are the main reason for eliminating the initial amorphous incubation layer in nc-Si:H growth on silicon oxide.

36 MATERIALS SCIENCE↗

Calibration of a high resolution grating soft x-ray spectrometer

The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 A waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High temperature Seebeck coefficient metrology

We present an overview of the challenges and practices of thermoelectric metrology on bulk materials at high temperature (300 to 1300 K). The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at high temperature. This has led to the implementation of nonideal practices that have further complicated the confirmation of reported high ZT materials. To ensure meaningful interlaboratory comparison of data, thermoelectric measurements must be reliable, accurate, and consistent. This article will summarize and compare the relevant measurement techniques and apparatus designs required to effectively manage uncertainty, while also providing a reference resource of previous advances in high temperature thermoelectric metrology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a high resolution and high dispersion Thomson parabola

Here, we report on the development of a novel high resolution and high dispersion Thomson parabola for simultaneously resolving protons and low-Z ions of more than 100 MeV/nucleon necessary to explore novel laser ion acceleration schemes. High electric and magnetic fields enable energy resolutions of {Delta}E/E < 5% at 100 MeV/nucleon and impede premature merging of different ion species at low energies on the detector plane. First results from laser driven ion acceleration experiments performed at the Trident Laser Facility demonstrate high resolution and superior species and charge state separation of this novel Thomson parabola for ion energies of more than 30 MeV/nucleon.

43 PARTICLE ACCELERATORS↗

Collisionless shock generation in high-speed counterstreaming plasma flows by a high-power laser

The experimental demonstration of the formation of a strong electrostatic (ES) collisionless shock has been carried out with high-speed counterstreaming plasmas, produced by a high-power laser irradiation, without external magnetic field. The nearly four times density jump observed in the experiment shows a high Mach-number shock. This large density jump is attributed to the compression of the downstream plasma by momentum transfer by ion reflection of the upstream plasma. Particle-in-cell (PIC) simulation shows the production of a collisionless high Mach-number ES shock with counterstreaming interaction of two plasma slabs with different temperatures and densities, as pointed out by Sorasio et al. [Phys. Rev. Lett. 96, 045005 (2006)]. It is speculated that the shock discontinuity is balanced with the momentum of incoming and reflected ions and the predominant pressure of the electrons in the downstream with PIC simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High efficiency multichannel collimator for structural studies of liquids and low-Z materials at high pressures and temperatures

A high efficiency multichannel collimator (MCC) device has been developed at the high pressure beamline ID27 of the European Synchrotron Radiation Facility to drastically reduce the x-ray background from the sample environment in the Paris-Edinburgh press. The main technical difficulty, which resides in the minimum slits size achievable using the classical mono-bloc design, has been resolved using an original concept based on a set of independent slits. Then, a very small slit size of 50 {mu}m was manufactured resulting in a great improvement of the signal to background ratio. In addition, the transfer function of the MCC has been measured using the x-ray diffusion signal of a metal doped glass and efficiently applied to correct the raw data. The potential of this new device is illustrated in two challenging examples: iron-sulfur liquid structures and C{sub 60} polymerization process at high pressure and high temperature.

43 PARTICLE ACCELERATORS↗

Combined ultrasonic elastic wave velocity and microtomography measurements at high pressures

Combined ultrasonic and microtomographic measurements were conducted for simultaneous determination of elastic property and density of noncrystalline materials at high pressures. A Paris-Edinburgh anvil cell was placed in a rotation apparatus, which enabled us to take a series of x-ray radiography images under pressure over a 180{sup o} angle range and construct accurately the three-dimensional sample volume using microtomography. In addition, ultrasonic elastic wave velocity measurements were carried out simultaneously using the pulse reflection method with a 10{sup o} Y-cut LiNbO{sub 3} transducer attached to the end of the lower anvil. Combined ultrasonic and microtomographic measurements were carried out for SiO{sub 2} glass up to 2.6 GPa and room temperature. A decrease in elastic wave velocities of the SiO{sub 2} glass was observed with increasing pressure, in agreement with previous studies. The simultaneous measurements on elastic wave velocities and density allowed us to derive bulk (K{sub s}) and shear (G) moduli as a function of pressure. K{sub s} and G of the SiO{sub 2} glass also decreased with increasing pressure. The negative pressure dependence of K{sub s} is stronger than that of G, and as a result the value of K{sub s} became similar to G at 2.0-2.6 GPa. There is no reason why we cannot apply this new technique to high temperatures as well. Hence the results demonstrate that the combined ultrasonic and microtomography technique is a powerful tool to derive advanced (accurate) P-V-Ks-G-(T) equations of state for noncrystalline materials.

47 OTHER INSTRUMENTATION↗

A highly modular beamline electrostatic levitation facility, optimized for in situ high-energy x-ray scattering studies of equilibrium and supercooled liquids

High-energy x-ray diffraction studies of metallic liquids provide valuable information about structural evolution on the atomic length scale, leading to insights into the origin of the nucleation barrier and the processes of supercooling and glass formation. The containerless processing of the beamline electrostatic levitation (BESL) facility allows coordinated thermophysical and structural studies of equilibrium and supercooled liquids to be made in a contamination-free, high-vacuum ({approx}10{sup -8} Torr) environment. To date, the incorporation of electrostatic levitation facilities into synchrotron beamlines has been difficult due to the large footprint of the apparatus and the difficulties associated with its transportation and implementation. Here, we describe a modular levitation facility that is optimized for diffraction studies of high-temperature liquids at high-energy synchrotron beamlines. The modular approach used in the apparatus design allows it to be easily transported and quickly setup. Unlike most previous electrostatic levitation facilities, BESL can be operated by a single user instead of a user team.

47 OTHER INSTRUMENTATION↗