Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

An electronic circuit that detects left ventricular ejection events by processing the arterial pressure waveform

An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.

Gebben, V. D.↗

Metabolic, respiratory, and cardiological measurements during exercise and rest

Low concentration effects of CO2 on metabolic respiration and circulation were measured during work and at rest. The relationship between heart rate and metabolic rate is examined, as well as calibration procedures, and rate measurement during submaximal and standard exercise tests. Alterations in acid base and electrolytes were found during exhaustive exercise, including changes in ECG and metabolic alkalosis effects.

Source record↗

Southwest Research Institute assistance to NASA in biomedical areas of the technology

Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

Culclasure, D. F.↗

Design of a specialized computer for on-line monitoring of cardiac stroke volume

The design of a specialized analog computer for on-line determination of cardiac stroke volume by means of a modified version of the pressure pulse contour method is presented. The design consists of an analog circuit for computation and a timing circuit for detecting necessary events on the pressure waveform. Readouts of arterial pressures, systolic duration, heart rate, percent change in stroke volume, and percent change in cardiac output are provided for monitoring cardiac patients. Laboratory results showed that computational accuracy was within 3 percent, while animal experiments verified the operational capability of the computer. Patient safety considerations are also discussed.

Webb, J. A., Jr.↗

Thermal testing techniques for space shuttle thermal protection system panels

An experimental system was developed for evaluation of the effects of aerodynamic heating and cooling, vacuum, and pressure loading on candidate insulation packages proposed for use on the space shuttle. The system includes a number of design features which facilitate rapid recycle times. This is necessary to efficiently conduct extensive thermal cycling tests on these insulation packages to determine their reuse capabilities. The heart of the system is a 26-inch graphite element radiant heater. A susceptor plate functions as a uniform-temperature intermediate radiating surface. The susceptor also forms the lid of an inert atmosphere enclosure which separates the heater from the oxidizing test atmosphere. In some tests the plate properly simulates the heating from an actual flight heat-shield panel. Although other materials were used at lower required test temperatures, 2500 F was routinely achieved using a coated columbium susceptor plate.

Cox, B. G.↗

Operational testing of system for automatic sleep analysis

Tables on the performance, under operational conditions, of an automatic sleep monitoring system are presented. Data are recorded from patients who were undergoing heart and great vessel surgery. This study resulted in cap, electrode, and preamplifier improvements. Children were used to test the sleep analyzer and medical console write out units. From these data, an automatic voltage control circuit for the analyzer was developed. A special circuitry for obviating the possibility of incorrect sleep staging due to the presence of a movement artifact was also developed as a result of the study.

Kellaway, P.↗

Precomputed state dependent digital control of a nuclear rocket engine

A control method applicable to multiple-input multiple-output nonlinear time-invariant systems in which desired behavior can be expressed explicitly as a trajectory in system state space is developed. The precomputed state dependent control method is basically a synthesis technique in which a suboptimal control law is developed off-line, prior to system operation. This law is obtained by conducting searches at a finite number of points in state space, in the vicinity of some desired trajectory, to obtain a set of constant control vectors which tend to return the system to the desired trajectory. These vectors are used to evaluate the unknown coefficients in a control law having an assumed hyperellipsoidal form. The resulting coefficients constitute the heart of the controller and are used in the on-line computation of control vectors. Two examples of PSDC are given prior to the more detailed description of the NERVA control system development.

Johnson, M. R.↗

Calculation of neutron-decay-proton trapping in the Jovian magnetosphere

Investigations on the possible proton fluxes resulting from cosmic ray albedo neutron decay (CRAND) are summarized. It is recalled that experimental data on the earth's belts are reasonably consistent with a CRAND source for most of the protons with energies 50 MeV in the heart of the inner belt. It is assumed that the CRAND and cosmic ray flux and spectrum for Jupiter are the same as for the Earth, with the significant difference that considerably higher energy particles are needed to reach the Jupiter atmosphere at the same magnetic latitude. The ratio of the CRAND source averaged over an L shell on Jupiter to that on Earth at L = 1.3 is derived from a geometrical calculation. The ratio of average loss rate on Jupiter to that for the Earth is also discussed. The flux around Jupiter is obtained by scaling according to the ratio of source to loss from the flux observed in the Earth's inner belt.

Thomas, J. R.↗

The study of human venous system dynamics using hybrid computer modeling

A computer-based model of the cardiovascular system was created emphasizing effects on the systemic venous system. Certain physiological aspects were emphasized: effects of heart rate, tilting, changes in respiration, and leg muscular contractions. The results from the model showed close correlation with findings previously reported in the literature.

Snyder, M. F.↗

S-cubed-a spacecraft and experiment description

The launch of the Explorer 45 satellite and the instruments installed in the satellite are discussed. The scientific objectives of the first mission, the orbital parameters, and the capabilities of the data system are examined. The satellite is designed to carry out investigations of specific magnetospheric phenomena in the heart of the magnetosphere. The data handling system is programmable from the ground for greater flexibility.

Longanecker, G. W.↗

Rare-gas effects on metabolism and inert gas narcosis

The detailed examination is reported of the theory that narcosis results from expansion of the cell membrane under high partial pressures. The research is partially based on the hypothesis that, like oxygen toxicity, the mechanism of metabolic effects of rare gases may be similar at both low and high pressures and are simply more observable at high pressures. Using adult female goats, the parameters measured include oxygen consumption, CO2 production, respiration rate, heart rate, rectal and skin temperatures and the analysis of electroencephalograms and evoked response. Additionally, the specific activity is measured of plasma glucose subsequent to injection of glucose-UL-C-14, intravenous infusion, specific activity of expired CO2, unesterified fatty acid levels and whole blood lactate-to-pyruvate ratios. Also studied were the effects of acetylsalicylic acid, vitamin E and cationic detergents (which alleviate narcosis) upon metabolic changes induced by high pressure narcosis.

Source record↗

Peripheral venous scintillation angiocardiography in determination of left ventricular volume in man.

Left ventricular end-diastolic volume was determined by cardiac visualization after peripheral venous injection of a gamma-emitting isotope in 10 patients with organic heart disease. The left ventricular end-diastolic volume measured by the isotope method consistently averaged 9% less than that determined by the X-ray method. The mean difference in left ventricular end-diastolic volume was 21 ml. Excellent correlation between the two methods was observed. It is pointed out that peripheral venous scintillation angiocardiography compares well with left ventriculography in the determination of left ventricular end-diastolic volume in man.

Sullivan, R. W.↗

Techniques for gamma rays.

The detecting systems used in high energy astrophysics are generally more similar to particle detectors than to optical devices. The basic design of the gamma ray instrument depends on whether the energy range is below about 10 MeV and therefore in the region where the Compton effect predominates in the absorption of the gamma-rays, or above that energy where electron-positron pair production is most important. The most usual approach to the detector system in the lower of the two energy intervals is to use a scintillation counter in the center of the detector system to absorb the photons and permit a measure of their energy, and to surround it by another detector which is employed as an active anticoincidence shield to discriminate against charged particles. In the gamma-ray interval above about 10 MeV, the very low flux of gamma rays and the high particle background has directed the development of high energy gamma-ray telescopes towards complicated techniques and large detector arrays. As a result, several investigators have now turned to the spark chamber as the heart of a detector system. Generally, it is surrounded by an anticoincidence system and is triggered by a counter telescope.

Fichtel, C. E.↗

Nuclear radiation interference and damage effects in charged particle experiments for extended space missions.

Demonstration that meaningful galactic and solar cosmic radiation measurements can be carried out on deep space missions. The radioisotopic thermoelectric generators (RTGs) which must be used as a source of power and perhaps of heat are a problem, but with proper separation from the experiments, with orientation, and with some shielding the damage effects can be reduced to an acceptable level. The Pioneer spacecraft are crucial in that they are targeted at the heart of Jupiter's radiation belts, and should supply the details of those belts. The subsequent Grand Tour opportunities can be selected for those periods which result in larger distances of closest approach to Jupiter if necessary.

Trainor, J. H.↗

Myocardial correlates of helium-cold induction and maintenance of hypothermia.

Hypothermia was induced in the golden hamster Mesocricetus auratus, using the helium-cold method. The first group of hamsters was sacrificed immediately after induction to rectal temperature 7 C, a second group was sacrificed after being maintained at a body temperature of 7 C for 18-24 hr, and a third group consisted of unexposed controls. The hearts were excised and the ventricles analyzed for hypoxic damage, glycogen, and catecholamines. In the short-term hypothermic animals, resting tension was increased while peak isometric tension, generated tension after 10 min of anoxic exposure, glycogen, and catecholamines were all reduced. All of the functional parameters recovered in the long-term hypothermic group, while glycogen and catecholamines showed a trend toward recovery. It is concluded that myocardial hypoxia develops during induction into hypothermia when using the helium-cold method. This effect is reversible and hypoxic damage does not increase as the hypothermic exposure is prolonged.

Anderson, G. L.↗

The use of computer graphic techniques for the determination of ventricular function.

Description of computer techniques employed to increase the speed, accuracy, reliability, and scope of angiocardiographic analyses determining human heart dimensions. Chamber margins are traced with a Calma 303 digitizer from projections of the angiographic films. The digitized margins of the ventricular images are filed in a computer for subsequent analysis. The margins can be displayed on the television screen of a graphics unit for individual study or they can be viewed in real time (or at any selected speed) to study dynamic changes in the chamber outline. The construction of three dimensional images of the ventricle is described.

Sandler, H.↗

Importance of the splanchnic vascular bed in human blood pressure regulation.

Three-part experiment in which five subjects were exposed to lower body negative pressure (LBNP) at -50 mm Hg below the iliac crests. Duration of LBNP to earliest vagal symptoms was 7 to 21 min; all data are expressed as changes from control period to the last measurements before these symptoms. In part I, forearm blood flow (by Whitney gauge) fell 45% during LBNP. In part II, splanchnic blood flow (from arterial clearance hepatic extraction of indocyanine green) fell 32% and splanchnic vascular resistance rose 30%. In part III, cardiac output fell 28%, stroke volume 51%, and central blood volume 21%. Total peripheral resistance and heart rate rose 19% and 52%. Of the reduction in total vascular conductance, decreased splanchnic conductance accounted for approximately 33%; skin plus muscle conductance decreased similarly.

Rowell, L. B.↗

Action of acetylstrophanthidin on experimental myocardial infarction.

An experimental animal model with acute myocardial infarction of a size insufficient to produce profound heart failure or shock was used to study the effects of acute infarction on digitalis tolerance and the hemodynamic changes produced by moderate and large doses of acetylstrophanthidin. With acute myocardial infarction, digitalis toxic arrhythmias could be precipitated with significantly lower doses of digitalis than in animals without myocardial infarction. There was no precise correlation between the size of infarction and the toxic dose of glycoside. Coronary artery ligation produced a stable but relatively depressed circulatory state, as evidenced by lowered cardiac output and stroke volume and elevated systemic vascular resistance and left atrial mean pressure. When digitalis was infused, the following significant changes were observed at nontoxic doses: (1) elevation of aortic and left ventricular pressures; (2) further decline in cardiac output; and (3) decreased left atrial mean pressure.

Nola, G. T.↗