Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GOLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

A Luminosity Model of RHIC Gold Runs

In this note, we present a luminosity model for RHIC gold runs. The model is applied to the physics fills in 2007 run without cooling, and with the longitudinal cooling applied to one beam only. Having good comparison, the model is used to project a fill with the longitudinal cooling applied to both beams. Further development and possible applications of the model are discussed.

43 PARTICLE ACCELERATORS↗

Reaction Between Thin Gold Wires and Pb-Sn-In Solder (37.5%, 37.5%, 25%), Part C: A comprehensive Model of the Reaction Inside the Solder Mounds in Both the "Interface Controlled Regime" and the "Diffusion-Controlled" Regime During Long-Term Exposure

In part A, all available literature data are displayed in tables, and plotted in figure 1. The slopes of the lines through the data in figure 1 suggest that there is a change in the rate controlling mechanism from interface control (linear with time, slope equals one in figure 1) to diffusion control (proportional to square root of time, slope one half in figure 1) as the gold consumption increases. Here we develop a model for the diffusion controlled reaction using data from planar and circular geometry. We determine the regimes in time and temperature where the reaction is diffusion controlled and where it is interface controlled, and then derive the set of equations for a comprehensive time and temperature dependent model that describes the reaction for all temperatures and time.

36 MATERIALS SCIENCE↗

1 Mil Gold Bond Wire Study

In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

Huff, Johnathon D.↗

Run 16 Tandem gold performance in the injectors and possible improvement with AGS type 6:3:1 bunch merge in the Booster

During Run 16 the Tandem was used as the Gold pre-injector for a brief time so that RHIC could continue running while EBIS was down for repairs. Given the time constraints, the setup was largely derived from the EBIS Au setup. The EBIS Au setup used a 4:2:1 bunch merge in the Booster and a 12:6:2 bunch merge in the AGS.1 This note will describe the Tandem Au setup and compare it to that used for EBIS Au. The bunch merge in the Booster for Tandem Au did not work well, and it seems likely that the performance would’ve been significantly better if it did. An AGS type 6:3:1 merge in the Booster is described which might improve matters.2 Somewhat speculative estimates for the AGS bunch intensity and emittance, if that merge were successful in reducing the Booster extraction emittance to EBIS Au levels, are also given for several potential setups. Using 6 Booster loads from the Tandem, the AGS bunch intensity at extraction reached about 2.5e9 ions with a longitudinal emittance (ε) of about 0.59 eV·s/n.3 Using 12 Booster loads from EBIS, the peak bunch intensity and ε was about 3.1e9 ions and 0.75 eV·s/n, respectively. A 6.4 sec supercycle was used for both at the time, but the Tandem Au supercycle (barring any potential issues with Tandem) could probably have been reduced to about 4.6 sec.

43 PARTICLE ACCELERATORS↗

Sulfur-induced structural motifs on copper and gold surfaces

The interaction of sulfur with copper and gold surfaces plays a fundamental role in important phenomena that include coarsening of surface nanostructures, and self-assembly of alkanethiols. Here, we identify and analyze unique sulfur-induced structural motifs observed on the low-index surfaces of these two metals. We seek out these structures in an effort to better understand the fundamental interactions between these metals and sulfur that lends to the stability and favorability of metal-sulfur complexes vs. chemisorbed atomic sulfur. The experimental observations presented here—made under identical conditions—together with extensive DFT analyses, allow comparisons and insights into factors that favor the existence of metal-sulfur complexes, vs. chemisorbed atomic sulfur, on metal terraces. We believe this data will be instrumental in better understanding the complex phenomena occurring between the surfaces of coinage metals and sulfur.

36 MATERIALS SCIENCE↗

Gold-manganese nanoparticles for targeted diagnostic and imaging

Imagine the possibility of non-invasive, non-radiation based Magnetic resonance imaging (MRI) in combating cardiac disease. Researchers at the Savannah River National Laboratory (SRNL) are developing a process that would use nanotechnology in a novel, targeted approach that would allow MRIs to be more descriptive and brighter, and to target specific organs. Researchers at SRNL have discovered a way to use multifunctional metallic gold-manganese nanoparticles to create a unique, targeted positive contrast agent. SRNL Senior Scientist Dr. Simona Hunyadi Murph says she first thought of using the nanoparticles for cardiac disease applications after learning that people who survive an infarct exhibit up to 15 times higher rate of developing chronic heart failure, arrhythmias and/or sudden death compared to the general population. Without question, nanotechnology will revolutionize the future of technology. The development of functional nanomaterials with multi-detection modalities opens up new avenues for creating multi-purpose technologies for biomedical applications.

36 MATERIALS SCIENCE↗

Comparing the effect on the AGS longitudinal emittance of gold ions from the BtA stripping foil with and without a Booster Bunch Merge

The aim of this note to better understand the effect of merging the Gold bunches in the Booster into one on the resulting AGS longitudinal emittance as compared to not merging them. The reason it matters whether they are merged or not is because they pass through a stripping foil in the BtA line. Data was taken last run (Run 17) for the case where the bunches are not merged, and it will be compared with data from cases where the bunches are merged. Previous data from Tandem operation will also be considered. There are two main pieces to this puzzle. The first is the ε growth associated with the energy spread due to ‘energy straggling’ in the BtA stripping foil and the second is the effective ε growth associated with the energy loss that occurs while passing through the foil. Both of these effects depend on whether or not the Booster bunches have been merged into one.

43 PARTICLE ACCELERATORS↗

The 2020 Low Energy Gold Run in the Injectors

During Run 20 the injectors provided Gold to RHIC at four different energies (3.85, 4.59, 5.75, and 7.3 GeV). The majority of the run was spent providing 4.59 and 5.75 GeV beams. The RHIC physics program using 5.75 GeV beam took place from Dec. 10, 2019 to Feb. 24, 2020, although there was a period of about 2 weeks (Jan. 27 th to Feb. 10 th ) where 7.3 and 4.59 GeV were used. The 4.59 GeV program took place from Feb. 24. 2020 to Sept.1 2020. Data taking for the 4.59 GeV program was interrupted by the COVID-19 shutdown which lasted about 3 months, from Mar. 20 to June 21. So, the 5.75 GeV program was about 2 months long and the 4.59 GeV program was about 3 months long. There were also other short periods where 7.3 GeV beam was provided to RHIC for CeC development and fixed target data taking. 3.85 GeV beam was also provided near the end of the run in preparation for next year (Sept. 2-11).

43 PARTICLE ACCELERATORS↗

FY2020-21 parameters for Gold ions in Booster, AGS, and RHIC

Sections 1 through 6 of this report give parameters for low-energy gold ions circulating in RHIC at injection and in AGS at extraction. Section 7 gives parameters for Au79+ ions circulating in RHIC at the standard injection magnetic rigidity of 81.11378003 Tm. Sections 8 through 10 give parameters for medium-energy Au79+ ions circulating in RHIC at 31.2, 26.5, 19.5, 13.5 GeV per nucleon. To reach these energies, acceleration in RHIC is required. The magnetic rigidity at RHIC injection for these setups is 60.3050632557 Tm. The corresponding ion energy is 7.30950517185 GeV per nucleon.

43 PARTICLE ACCELERATORS↗

Beam Degrader Wheel for Gold Beams at NSRL (V.1.0)

The NSRL Binary Filter is used to measure the beam energy of heavily ionizing ions by degrading the beam in polyethylene (PE) of thickness up to 26 cm. The finest graduation is 0.25 mm. When we are running Gold ions at energies of 100 to 200 MeV/nucleon, the range is quite short; 2 to 7 mm in PE. In order to obtain good energy resolution, we require gradations in PE that are 0.1mm or finer.

43 PARTICLE ACCELERATORS↗

An additional gold ion energy in RHIC for the FY2021 run

Parameters for an additional gold ion energy in RHIC between 7.3 and 9.8 GeV per nucleon are considered here. The critical factor driving the choice of an energy in this range is the need to be sufficiently far from transition at AGS extraction. The ion energy favored by STAR, 8.65 GeV per nucleon, is found to be a suitable choice. The parameters for this energy are given in Section 7 of the following

43 PARTICLE ACCELERATORS↗

The 2023 Gold Run in the Injectors

RHIC Run 23 used Gold beam from Tandem with an AGS extraction energy of 9.8 GeV. The same basic setup, 8 single bunch transfers from the Booster and a 12-6 merge in the AGS to provide 4 bunches at extraction, had been used before to deliver Tandem Au to RHIC. But in those cases, it was used for low energy runs (3.85 GeV in 2021 and 5.75 GeV in 2020) where extraction was below transition energy (7.9 GeV). Tandem beam was used for this run because the intensity and stability of EBIS Au did not meet the requirements for RHIC. Physics was first declared in RHIC on May 22 nd and on August 1 st the run was cut short by about 2 months due to a major failure in RHIC. Prior to the advent of EBIS as the preinjector in 2012, 9.8 GeV Tandem Au was regularly delivered to RHIC but the setup in the Booster and AGS was quite different: Four Booster transfers of 6 bunches each were merged into 4 bunches using a 24-12-4 merge scheme. The supercycle length was 6.0 sec before June 29 th when it was extended to 6.6 sec to accommodate EBIS commissioning. The Tandem, Booster, and AGS were on user 1 for the 9.8 GeV setup. Some work with EBIS Au 32+ took place on EBIS, Booster, and AGS user 5 using the standard 9.8 GeV injector setup with a 4 to 1 merge in Booster and a 6-3-1 type merge in AGS. The Siemens motor generator was used for the entire run. An intensity limit of 8.0e9 Au 77+ ions in the AGS was in effect during the run to protect the J7 plunging stripping foil and the Copper absorber of the AGS beam dump. This corresponds to a merged bunch intensity limit of 2.0e9 Au 77+ ions for 4 equal intensity bunches. The per bunch intensity limit can be increased to 2.67e9 by reducing the number of BtA transfers from 8 to 6. There was also a Booster Late intensity limit of 16e9 Au ions in effect to protect the BtA stripping foil from damage due to overheating. Lowering the number of transfers also makes this limit less of a constraint. BtA foil 5, which was installed in 2020 and had not been used regularly prior to this run was used all run and showed no obvious signs of deterioration. In May, a Tandem Au 3.85 GeV setup from 2021 was also re-established on AGS user 2. It was used for APEX on May 24 and July 26. Initial work with 3.85 GeV beam was on May 19. Proton beam was also set up during the run and extracted to W dump on July 10. It was used for APEX on July 12. Although the OPPIS source was used the AGS setup was without snakes.

43 PARTICLE ACCELERATORS↗

Gold Catalyzed Polymerization Reactions of Unsaturated Substrates: Towards New Functional, Recyclable, and Upcycled Aromatic Polymers (Final Report)

The overarching goal of this project lied in the translation of gold (Au) catalyzed small molecule synthetic transformations to the field of polymer science, the generation of new macromolecular structures, and the application of the materials and methodologies produced toward sustainable polymer development and chemical upcycling. Specifically, this project aimed to polymerize monomers based on unsaturated precursors and access novel polymeric materials through the extension of Au catalyzed intermolecular processes. The specific objectives of this project comprised: (1) the extension of Au-catalyzed intermolecular reactions to bifunctional monomers and the polycondensation of diverse nucleophiles; (2) to gain fundamental mechanistic insight into Au-catalyzed polymerizations; (3) the application of these reactions to the synthesis of new classes of aromatic polymers that can be readily and/or selectively deconstructed; and (4) to apply these chemistries to post-polymerization modification (PPM) of commercially relevant polyaromatic substrates, including post-industrial plastics and post-consumer waste.

36 MATERIALS SCIENCE↗

Low-dose gold nanoparticles exert subtle endocrine-modulating effects on the ovarian steroidogenic pathway ex vivo independent of oxidative stress

Gold nanoparticles (GNPs) have gained considerable attention for application in science and industry. However, the untoward effects of such particles on female fertility remain unclear. The objectives of this study were to (1) examine the effects of 10-nm GNPs on progesterone and estradiol-17b accumulation by rat ovaries ex vivo and (2) to identify the locus/loci whereby GNPs modulate steroidogenesis via multiple-reference gene quantitative real-time RT-PCR. Regression analyses indicated a positive relationship between both Star (p < 0.05, r2 = 0.278) and Cyp11a1 (p < 0.001, r2 = 0.366) expression and P4 accumulation. upon exposure to 1.43 * 106 GNPs/mL. Additional analyses showed that E2 accumulation was positively associated with Hsd3b1 (p < 0.05, r2 = 0.181) and Cyp17a1 (p < 0.01, r2 = 0.301) expression upon exposure to 1.43 * 13 and 1.43 * 109 GNPs/mL, respectively. These results suggest a subtle treatmentdependent impact of low-dose GNPs on the relationship between progesterone or estradiol-17b and specific steroidogenic target genes, independent of oxidative stress or inhibin.

Larson, Jeremy K.↗

Development of a colloidal gold immunochromatographic assay strip using monoclonal antibody for rapid detection of porcine deltacoronavirus

Porcine deltacoronavirus (PDCoV) cause diarrhea and dehydration in newborn piglets and has the potential for cross-species transmission. Rapid and early diagnosis is important for preventing and controlling infectious disease. In this study, two monoclonal antibodies (mAbs) were generated, which could specifically recognize recombinant PDCoV nucleocapsid (rPDCoV-N) protein. A colloidal gold immunochromatographic assay (GICA) strip using these mAbs was developed to detect PDCoV antigens within 15 min. Results showed that the detection limit of the GICA strip developed in this study was 10 3 TCID 50 /ml for the suspension of virus-infected cell culture and 0.125 μg/ml for rPDCoV-N protein, respectively. Besides, the GICA strip showed high specificity with no cross-reactivity with other porcine pathogenic viruses. Three hundred and twenty-five fecal samples were detected for PDCoV using the GICA strip and reverse transcription-quantitative real-time PCR (RT-qPCR). The coincidence rate of the GICA strip and RT-qPCR was 96.9%. The GICA strip had a diagnostic sensitivity of 88.9% and diagnostic specificity of 98.5%. The specific and efficient detection by the strip provides a convenient, rapid, easy to use and valuable diagnostic tool for PDCoV under laboratory and field conditions.

Wang, Wei↗