Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Data Driven Temperature Control of Heat Exchangers

The following poster presents a couple of approaches for temperature control at heat exchanger’s exit. One of the approaches is based on using n-step ahead neural network while the other approach utilizes a combination of control + learning module for temperature control. Designing robust controllers for typical heat exchangers is very challenging primarily because of complexities associated with the synthesis of dynamics of industrial heat exchangers. Even if a dynamics model is synthesized, the accuracy of it would be called into question as there can be lot of unmodeled system dynamics and random noise in input parameters. In many situations, the degree of uncertainty in the model of system being controlled limits the utility of optimal control design. Controller can be manually tuned on the field but it is very difficult to determine manual adjustments that result in overall improvement. These practical challenges call for learning based approaches for temperature control that would result in optimal heat exchanger performance. We utilize the existing mathematical model for air-water system synthesized by Underwood and Crawford for testing our algorithms. Underwood and Crawford developed a model of heating coil by fitting a second-order non-linear equations to measurements of air and water temperature and flow rates obtained from the actual coil. The uncertainties in the model include air and water inlet temperatures and air-flow rate. These uncertainties are modeled as random variables that are sampled from a uniform distribution. The control variable is the water flow rate which is controlled for regulating the air-outlet temperature. Neural networks are frequently used in various literatures for learning time-series. We propose a modified version of neural networks known as n-step ahead neural network that take the state variables and output at time t as input to successfully predict output at time t+n. The variable n is a hyper-parameter which can be optimized based on performance constraints. The n-step ahead neural network was then trained on training data generated from experimental model to high training accuracies. This trained model performed appreciably in its objective to regulate outlet temperature of a heat exchanger. The second approach uses a combination of control and learning module for temperature regulation. The control module used is a proportional controller while the learning module used is steady state neural network. The steady state neural network is used to learn the controller output as a function of random variables and temperature set-point. The proportional controller is then used to compensate for transient behavior of linearized system around various operating points. The algorithm works effectively for temperature regulation as neural network captures the non-linear input-output behavior of closed loop system leaving proportional controller to compensate for steady state errors of a linearized plant. The proposed algorithm’s performances were evaluated against the performance of a PI controller. Further, the robustness of the algorithms were also studied in great detail under small perturbations around tuned parameters of the proposed algorithms.

Sundar, Sreenath↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fluoride Salt-Cooled High-Temperature Demonstration Reactor Point Design

The fluoride salt-cooled high-temperature reactor (FHR) demonstration reactor (DR) is a concept for a salt-cooled reactor with 100 megawatts of thermal output (MWt). It would use tristructural-isotropic (TRISO) particle fuel within prismatic graphite blocks. FLiBe (2 LiF-BeF 2 ) is the reference primary coolant. The FHR DR is designed to be small, simple, and affordable. Development of the FHR DR is a necessary intermediate step to enable near-term commercial FHRs. Lower risk technologies are purposely included in the initial FHR DR design to ensure that the reactor can be built, licensed, and operated within an acceptable budget and schedule. These technologies include TRISO particle fuel, replaceable core structural material, the use of that same material for the primary and intermediate loops, and tube-and-shell primary-to-intermediate heat exchangers. Several preconceptual and conceptual design efforts that have been conducted on FHR concepts bear a significant influence on the FHR DR design. Specific designs include the Oak Ridge National Laboratory (ORNL) advanced high-temperature reactor (AHTR) with 3400/1500 MWt/megawatts of electric output (MWe), as well as a 125 MWt small modular AHTR (SmAHTR) from ORNL. Other important examples are the Mk1 pebble bed FHR (PB-FHR) concept from the University of California, Berkeley (UCB), and an FHR test reactor design developed at the Massachusetts Institute of Technology (MIT). The MIT FHR test reactor is based on a prismatic fuel platform and is directly relevant to the present FHR DR design effort. These FHR concepts are based on reasonable assumptions for credible commercial prototypes. The FHR DR concept also directly benefits from the operating experience of the Molten Salt Reactor Experiment (MSRE), as well as the detailed design efforts for a large molten salt reactor concept and its breeder variant, the Molten Salt Breeder Reactor. The FHR DR technology is most representative of the 3400 MWt AHTR concept, and it will demonstrate key operational features of that design. The FHR DR will be closely scaled to the SmAHTR concept in power and flows, so any technologies demonstrated will be directly applicable to a reactor concept of that size. The FHR DR is not a commercial prototype design, but rather a DR that serves a cost and risk mitigation function for a later commercial prototype. It is expected to have a limited operational lifetime compared to a commercial plant. It is designed to be a low-cost reactor compared to more mature advanced prototype DRs. A primary reason to build the FHR DR is to learn about salt reactor technologies and demonstrate solutions to remaining technical gaps.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Repetitive formation and decay of current sheets in magnetic loops: An origin of diverse magnetic structures

In this work, evolution of an incompressible, thermally homogeneous, infinitely conducting, viscous magnetofluid is numerically explored as the fluid undergoes repeated events of magnetic reconnection. The initial magnetic field is constructed by a superposition of two linear force-free fields and has similar morphology as the magnetic loops observed in the solar corona. The results are presented for computations with three distinct sets of footpoint geometries. To onset reconnection, we rely on numerical model magnetic diffusivity, in the spirit of implicit large eddy simulation. It is generally expected that in a high Lundquist number fluid, repeated magnetic reconnections are ubiquitous and hence can lead to a host of magnetic structures with considerable observational importance. In particular, the simulations presented here illustrate formations of magnetic islands, rotating magnetic helices and rising flux ropes—depending on the initial footpoint geometry but through the common process of repeated magnetic reconnections. Further, we observe the development of extended current sheets in two case studies, where the footpoint reconnections generate favorable dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Testing for a New Thermosyphon Irradiation Vehicle

The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL) requires most materials and all fuel experiments to be placed in a pressure containment vessel to ensure that internal contaminants such as fission products cannot be released into the primary coolant. It also requires that all experiments be capable of withstanding various accident conditions (e.g., loss of coolant) without generating vapor bubbles on the surface of the experiment in the primary coolant. These requirements are intended to artificially increase experiment temperatures by introducing a barrier between the experimental materials and the HFIR coolant, and by reducing heat loads to the HFIR primary coolant, thus ensuring that no boiling can occur. A proposed design for materials irradiation would remove these limitations by providing the required primary containment with an internal cooling flow. This would allow for experiments to be irradiated without concern for coolant contamination (e.g., from cladding failure of advanced fuel pins) or for specimen heat load. This report describes a new materials irradiation experiment design that uses a thermosyphon cooling system to allow experimental materials direct access to a liquid coolant. The new design also increases the range of conditions that can be tested in HFIR. This design will provide a unique capability to validate the performance of current and advanced fuels and materials. Because of limited supporting data for this kind of irradiation vehicle, a test program was initiated to obtain operating data that can be used to (1) qualify the vehicle for operation in HFIR and (2) validate computer models used to perform design- and safety-basis calculations. This report also describes the test facility and experimental data, and it provides a comparison of the experimental data to computer simulations. A total of 51 tests have been completed: four tests with pure steam, 12 tests with argon, and 35 tests with helium. A total of 10 tests were performed at subatmospheric pressure, and four of these were performed with pure steam. One test was conducted at a high power of 92.7 kW, six tests were HFIR startups, and two tests were HFIR loss of offsite power (LOOP). Pressures up to 10 MPa, vapor temperatures up to 583 K (310°C), and heater temperatures above 600 K (327°C) have been reached in these tests. Two computer programs, RELAP5-3D and TRACE, have been used to simulate the tests. The TRACE code has shown good agreement with the test data and has been used to model a variety of tests. This experimental facility has been very useful in demonstrating the viability of this new type of irradiation facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In vivo evaluation of an adaptive resuscitation controller using whole blood and crystalloid infusates for hemorrhagic shock

Introduction Hemorrhage remains the leading cause of preventable death on the battlefield. The most effective means to increase survivability is early hemorrhage control and fluid resuscitation. Unfortunately, fluid resuscitation requires constant adjustments to ensure casualty is properly managed, which is often not feasible in the pre-hospital setting. In this study, we showed how an adaptive closed-loop controller for hemorrhage resuscitation can be used to automate hemodynamic management using a swine hemorrhagic shock injury model. Methods The adaptive resuscitation controller (ARC) was previously developed to track pressure–volume responsiveness in real time and adjust its infusion rate to reach the target mean arterial pressure (MAP). Swine while maintained under a surgical plane of anesthesia and analgesia underwent a splenectomy, followed by two hemorrhage and resuscitation events. For the first resuscitation event, hemorrhage was induced to reduce the MAP to 35 mmHg until arterial lactate reached 4 mmol/L. The ARC system then infused whole blood (WB) to reach the target MAP and maintained the subject using crystalloids for 120 min. For the second resuscitation event, the subjects were hemorrhaged again but resuscitated using only crystalloid infusion to reach the target MAP and 120-min maintenance. Results The ARC was effective at WB resuscitation, reaching the target MAP in 2.0 ± 1.0 min. The median performance error was 1.1% ± 4.6%, and target overshoot was 14.4% ± 7.0% of the target MAP. The ARC maintained all animals throughout the 120 min maintenance period. For the second crystalloid-based resuscitation, ARC required a longer time to reach the target MAP, at an average rise time of 4.3 ± 4.0 min. However, target overshoot was reduced to 8.4% ± 7.3% of the target MAP. Much higher flow rates were required to maintain the target MAP during the second resuscitation event than during the first resuscitation event. Discussion The ARC was able to rapidly reach and maintain the target MAP effectively. However, this sometimes required large volumes of fluid as the ARC’s only goal was to reach the target MAP. Further clinical insight is needed regarding the preferred aggression level to achieve the target MAP. In conclusion, the ARC was successful in its programmed objective of reaching and maintaining the target MAP for extended periods of time in vivo , a critical next step toward improving hemorrhage treatment in the pre-hospital environment.

Snider, Eric J.↗

Final Technical Report for NSF/DOE partnership grant 1004284/ER54905/SC0004660: 2011- 2013

Research has been performed on two topics: (1) Nonlinear time-dependent phenomena in the regime of electron magnetohydrodynamics (EMHD). (2) Plasma structures forming ”bubbles”. The latter are regions of localized density depletions or enhancements separated from the ambient plasma by sheaths or double layers. Three-dimensional magnetic null points can also be considered as ”magnetic bubbles”. Nonlinear EMHD fields are generated by pulsed magnetic loops. The magnetic field varies in time faster than an ion cyclotron period, hence interacts only with electrons. Space charge electric fields are created when magnetic forces try to separate electrons from ions. Electric and magnetic forces nearly balance to keep the plasma quasi neutral. This leads to rotational electron motions, i.e. Hall currents and associated magnetic perturbations. When the time scale falls between the ion and electron cyclotron period the magnetic perturbation is convected in the whistler mode. When the time-varying magnetic field exceeds the background magnetic field the whistler mode becomes highly nonlinear since its properties depend on the total magnetic field. When the time-varying magnetic field creates magnetic null points or null lines EMHD breaks down. Electrons can be accelerated in null lines which dissipated magnetic energy like in magnetic reconnection. Energized electrons with anisotropic distributions create secondary whistler instabilities. These effects have been observed in field topologies resembling spheromaks and field-reversed configurations (FRCs). The whistler mode propagation near magnetic nulls is not trivial when the field gradients and wavelength are comparable. Ray tracing is inappropriate when the WKB approximation breaks down. Experiments have been started to map wave propagation on curved field lines with null points. Initial results show that whistlers in highly nonuniform fields have highly oblique phase velocities but the energy flow remains dominantly along the field. Density bubbles are created by anode discharges, typically forming spherical ”fireballs” bounded by a double layer. In a magnetized plasma the shape becomes cylindrical, in nonuniform magnetic fields many asymmetric fireball shapes are possible. Due to electron energization the fireball plasma has higher density and temperature than the ambient plasma. The double layer can also be produced by a high transparency positively biased grid. Instabilities arise from the electron transit through the plasma bubble and the double layer. When a permanent magnet is biased positively the electrons perform ExB drifts in the equatorial plane between the poles. Electron drift modes are excited with a high spectral contents. Similarly, a negatively biased magnet produces a disk-shaped plasma bubble. The cold magnet emits secondary electrons due to the impact of energetic ions. Such magnetron discharges exhibit a variety of instabilities which affect the cross-field transport and sputtering applications. This report will summarize the main effects observed and provide references to more detailed publications.

, nonlinear time-dependent phenomena↗

Self-consistent feedback mechanism for the sudden viscous dissipation of finite-Mach-number compressing turbulence

Previous work [Davidovits and Fisch, Phys. Rev. Lett. 116, 105004 (2016)] demonstrated that the compression of a turbulent field can lead to a sudden viscous dissipation of turbulent kinetic energy (TKE), and that paper suggested this mechanism could potentially be used to design new fast-ignition schemes for inertial confinement fusion (ICF). We expand on previous work here by accounting for finite Mach numbers, rather than relying on a zero-Mach-limit assumption as previously done. The finite-Mach-number formulation is necessary to capture a self-consistent feedback mechanism in which dissipated TKE increases the temperature of the system, which in turn modifies the viscosity and thus the TKE dissipation itself. Direct numerical simulations with a tenth-order accurate Padé scheme were carried out to analyze this self-consistent feedback loop for compressing turbulence. Results show that, for finite Mach numbers, the sudden viscous dissipation of TKE still occurs, for both the solenoidal and dilatational turbulent fields. As the domain is compressed, oscillations in dilatational TKE are encountered due to the highly oscillatory nature of the pressure dilatation. An analysis of the source terms for the internal energy shows that the mechanical-work term dominates the viscous turbulent dissipation. As a result, the effect of the suddenly dissipated TKE on temperature is minimal for the Mach numbers tested. Moreover, an analytical expression is derived that confirms the dissipated TKE does not significantly alter the temperature evolution for low Mach numbers, regardless of compression speed. The self-consistent feedback mechanism is thus quite weak for subsonic turbulence, which could limit its applicability for ICF.

42 ENGINEERING↗

Mathematical Analysis of High-Temperature Co-electrolysis of CO2 and O2 Production in a Closed-Loop Atmosphere Revitalization System

NASA has been evaluating two closed-loop atmosphere revitalization architectures based on Sabatier and Bosch carbon dioxide, CO2, reduction technologies. The CO2 and steam, H2O, co-electrolysis process is another option that NASA has investigated. Utilizing recent advances in the fuel cell technology sector, the Idaho National Laboratory, INL, has developed a CO2 and H2O co-electrolysis process to produce oxygen and syngas (carbon monoxide, CO and hydrogen, H2 mixture) for terrestrial (energy production) application. The technology is a combined process that involves steam electrolysis, CO2 electrolysis, and the reverse water gas shift (RWGS) reaction. A number of process models have been developed and analyzed to determine the theoretical power required to recover oxygen, O2, in each case. These models include the current Sabatier and Bosch technologies and combinations of those processes with high-temperature co-electrolysis. The cases of constant CO2 supply and constant O2 production were evaluated. In addition, a process model of the hydrogenation process with co-electrolysis was developed and compared. Sabatier processes require the least amount of energy input per kg of oxygen produced. If co-electrolysis replaces solid polymer electrolyte (SPE) electrolysis within the Sabatier architecture, the power requirement is reduced by over 10%, but only if heat recuperation is used. Sabatier processes, however, require external water to achieve the lower power results. Under conditions of constant incoming carbon dioxide flow, the Sabatier architectures require more power than the other architectures. The Bosch, Boudouard with co-electrolysis, and the hydrogenation with co-electrolysis processes require little or no external water. The Bosch and hydrogenation processes produce water within their reactors, which aids in reducing the power requirement for electrolysis. The Boudouard with co-electrolysis process has a higher electrolysis power requirement because carbon dioxide is split instead of water, which has a lower heat of formation. Hydrogenation with co-electrolysis offers the best overall power performance for two reasons: it requires no external water, and it produces its own water, which reduces the power requirement for co-electrolysis.

08 HYDROGEN↗

Stationary Liquid Fuel Fast Reactor

For effective burning of hazardous transuranic (TRU) elements of used nuclear fuel, a transformational advanced reactor concept named SLFFR (Stationary Liquid Fuel Fast Reactor) was proposed based on stationary molten metallic fuel. The fuel enters the reactor vessel in a solid form, and then it is heated to molten temperature in a small melting heater. The fuel is contained within a closed, thick container with penetrating coolant channels, and thus it is not mixed with coolant nor flow through the primary heat transfer circuit. The makeup fuel is semi- continuously added to the system, and thus a very small excess reactivity is required. Gaseous fission products are also removed continuously, and a fraction of the fuel is periodically drawn off from the fuel container to a processing facility where non-gaseous mixed fission products and other impurities are removed and then the cleaned fuel is recycled into the fuel container. A reference core design and a preliminary plant system design of a 1000 MWt TRU- burning SLFFR concept were developed using TRU-Ce-Co fuel, Ta-10W fuel container, and sodium coolant. Conservative design approaches were adopted to stay within the current material performance database. Detailed neutronics and thermal-fluidic analyses were performed to develop a reference core design. Region-dependent 33-group cross sections were generated based on the ENDF/B-VII.0 data using the MC2-3 code. Core and fuel cycle analyses were performed in theta-r-z geometries using the DIF3D and REBUS-3 codes. Reactivity coefficients and kinetics parameters were calculated using the VARI3D perturbation theory code. Thermo-fluidic analyses were performed using the ANSYS FLUENT computational fluid dynamics (CFD) code. Figure 0.1 shows a schematic radial layout of the reference 1000 MWt SLFFR core, and Table 0.1 summarizes the main design parameters of SLFFR-1000 loop plant. The fuel container is a 2.5 cm thick cylinder with an inner radius of 87.5 cm. The fuel container is penetrated by twelve hexagonal control assembly (CA) guide tubes, each of which has 3.0 mm thickness and 69.4 mm flat-to-flat outer distance. The distance between two neighboring CA guide tube is selected to be 26 cm to provide an adequate space for CA driving systems. The fuel container has 18181 penetrating coolant tubes of 6.0 mm inner diameter and 2.0 mm thickness. The coolant tubes are arranged in a triangular lattice with a lattice pitch of 1.21 cm. The fuel, structure, and coolant volume fractions inside the fuel container are 0.386, 0.383, and 0.231, respectively. Separate steel reflectors and B4C shields are used outside of the fuel container. Six gas expansion modules (GEMs) of 5.0 cm thickness are introduced in the radial reflector region. Between the radial reflector and the fuel container is a 2.5 cm sodium gap. The TRU inventory at the beginning of equilibrium cycle (BOEC) is 5081 kg, whereas the TRU inventory at the beginning of life (BOL) was 3541 kg. This is because the equilibrium cycle fuel contains a significantly smaller fissile fraction than the LWR TRU feed. The fuel inventory at BOEC is composed of 34.0 a/o TRU, 41.4 a/o Ce, 23.6 a/o Co, and 1.03 a/o solid fission products. Since uranium-free fuel is used, a theoretical maximum TRU consumption rate of 1.011 kg/day is achieved. The semi-continuous fuel cycle based on the 300-batch, 1- day cycle approximation yields a burnup reactivity loss of 26 pcm/day, and requires a daily reprocessing of 32.5 kg of SLFFR fuel. This yields a daily TRU charge rate of 17.45 kg, including a makeup TRU feed of 1.011 kg recovered from the LWR used fuel. The charged TRU-Ce-Co fuel is composed of 34.4 a/o TRU, 40.6 a/o Ce, and 25.0 a/o Co.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An effective thermal-hydraulics methodology for prismatic core HTGR and VHTR

Optimizing the performance and design of a prismatic core HTGR or VHTR requires a full core thermal-hydraulics analysis. Owing to the complexity and massive core structure, such analysis requires extensive and massively parallelized computation capabilities and a relatively long time (weeks to months) to complete. These demanding requirements are not due to the 3-D simulation of heat conduction in the annular core of the reactor, but rather the 3-D computational fluid dynamics (CFD) simulation of the helium gas flow in the 10-m long cooling channels in the 102 hexagonal fuel elements and the axial graphite reflector blocks in the core. This paper applies and examines the effectiveness of using a 1-D simulation of the helium flow in the core coolant channels, coupled to a 3-D simulation of the heat conduction in the graphite and fuel compacts, to perform thermal-hydraulics analysis of a hexagonal fuel element and of a 1/6 full core. This methodology employs typical cosine and constant axial power profiles and an applicable convective heat transfer correlation for the helium flow in the coolant channels. The correlation has recently been validated for a 10 m tall, single channel fuel module and shown to significantly reduce the computation time and memory requirements without compromising the accuracy of the calculations. The fidelity and accuracy of the present results for a hexagonal fuel element are verified by comparing them to those of a full 3-D numerical analysis. In addition to the temperature fields, results compare the computation time and number of numerical grid elements for implementing the two numerical simulation methods. The results of the thermal-hydraulics analysis of a 1/6 full core with the simplified methodology are also presented. All performed analysis accounts for the temperature dependent properties of helium, graphite in the reactor core and reflector blocks and the TRISO particle fuel compacts. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MULTIWAVELENGTH IMAGING AND SPECTROSCOPY OF CHROMOSPHERIC EVAPORATION IN AN M-CLASS SOLAR FLARE

We study spectroscopic observations of chromospheric evaporation mass flows in comparison with the energy input by electron beams derived from hard X-ray (HXR) data for the white-light M2.5 flare of 2006 July 6. The event was captured in high-cadence spectroscopic observing mode by SOHO/CDS combined with high-cadence imaging at various wavelengths in the visible, extreme ultraviolet, and X-ray domain during the joint observing campaign JOP171. During the flare peak, we observe downflows in the He I and O V lines formed in the chromosphere and transition region, respectively, and simultaneous upflows in the hot coronal Si XII line. The energy deposition rate by electron beams derived from RHESSI HXR observations is suggestive of explosive chromospheric evaporation, consistent with the observed plasma motions. However, for a later distinct X-ray burst, where the site of the strongest energy deposition is exactly located on the Coronal Diagnostics Spectrometer (CDS) slit, the situation is intriguing. The O V transition region line spectra show the evolution of double components, indicative of the superposition of a stationary plasma volume and upflowing plasma elements with high velocities (up to 280 km s{sup -1}) in single CDS pixels on the flare ribbon. However, the energy input by electrons during this period is too small to drive explosive chromospheric evaporation. These unexpected findings indicate that the flaring transition region is much more dynamic, complex, and fine structured than is captured in single-loop hydrodynamic simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

In-Process Melt Separation of Depolymerized PET in PET/PE Blends for Upcycling via Twin-Screw Extrusion

Our previous work focused on depolymerizing polyethylene terephthalate (PET) in twin-screw extrusion, as part of a broader project to continuously separate PET from polyolefins in the melt. This study focused on linear low-density polyethylene (LLDPE) and PET films and the use of ethylene glycol (EG), diethylene glycol (DEG), triethylene glycol (TEG), and bis(2-hydroxyethyl) terephthalate (BHET) to depolymerize the PET in the extruder to levels above 90% Mw. In this work, the focus will shift to achieving separation of the two polymers in the twin-screw extruder, which is made possible due to a 90% reduction in the Mw of the PET, which caused a decrease of its viscosity by several orders of magnitude. Owing to the viscosity difference and pressure buildup in the die, the low-viscosity PET preferentially exited a degassing vent instead of going through the die. This is because the flow of the PET would travel through a non-pressure vent rather than through a high-pressure die. However, owing to the higher viscosity of the LLDPE, the pressure was too high to pass through such a small diameter vent hole. Supercritical CO 2 (SCCO 2 ) was used to assist in this extraction, but SCCO 2 negatively impacted the overall degree of separation. Through analysis of the separated materials, it was concluded that a high separation of the two materials was achieved. TGA and FTIR confirmed that the material separated from the vent was 100% PET. The material removed from the die was composed of 95% LLDPE and 5% PET.

36 MATERIALS SCIENCE↗

Thermal-Mechanical Analysis of an Additive Manufacturing Ceramic Heat Exchanger for High-Temperature Recuperator in a sCO2 Power System

Supercritical CO2 (sCO2) Brayton power cycle can be configured in a closed-loop power system and has a potentially high cycle efficiency. Compactness and high efficiency of a sCO2 power block make the sCO2 Brayton cycle a versatile power cycle in broad applications. While many heat sources are of sufficient intensity to produce high temperature working fluids to achieve high cycle efficiency, the thermal-mechanical stability of traditional materials (e.g., steels and nickel-based superalloys) used in construction of heat exchangers and turbine components limits the operating conditions and thus thermodynamic efficiency of the system. This effort seeks to establish the viability of ceramic heat exchanger technologies for the most extreme operating conditions envisioned for power generation and other high temperature processes. Heat exchangers constructed from ultra-high temperature ceramics, a class of extreme environment materials featuring melting points (Tmp.) above 3000 degrees C, is particularly appealing for sCO2 Brayton cycles given their ultra-low creep rates and very high retained strength at low homologous temperatures (i.e., T < 0.5 Tmp., or at least 1500 degrees C). To translate these materials properties to ultra-high temperature heat exchangers, innovations are required in ceramic manufacturing techniques to realize the complex architectures featured in compact heat exchangers with high power density. With appropriate processing, ZrB2-SiC based compositions can be sintered to near full density and shaped into complex topologies via ceramic additive manufacturing methods. This paper analyzes heat exchanger designs and explores thermal-mechanical implications of the operating environment. Thermal flow, heat transfer, and conjugate mechanical analyses provide insights into benefits and risks associated with the design approach.

additive manufacturing↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines: Preprint

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be timeconsuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the towerbase damage equivalent loading and better tracking of the rated generator speed and power.

closed-loop control↗

In‐Process Melt Separation of PE/PET Blends for Upcycling via Twin‐Screw Extrusion. Impact of Catalyst Reagents on PET Depolymerization

Part 1 of this work focused on depolymerizing polyethylene terephthalate (PET) in twin-screw extrusion, as part of a broader project to continuously separate PET from polyolefins in the melt. This study focused on linear low-density polyethylene (LLDPE) and PET films and the use of ethylene glycol (EG), diethylene glycol (DEG), triethylene glycol (TEG), and bis(2-hydroxyethyl) terephthalate (BHET) to depolymerize the PET in the extruder to levels above 90% Mw. In part 2, the focus will shift to achieving separation of the two polymers in the twin-screw extruder, which is made possible due to a 90% reduction in the Mw of the PET, which caused a decrease of its viscosity by several orders of magnitude. Owing to the viscosity difference and pressure buildup in the die, the low-viscosity PET preferentially exited a degassing vent instead of going through the die. This is because the flow of the PET would travel through a non-pressure vent rather than through a high-pressure die. However, owing to the higher viscosity of the LLDPE, the pressure was too high to pass through such a small diameter vent hole. Supercritical CO₂ (SCCO₂) was used to assist in this extraction, but SCCO₂ negatively impacted the overall degree of separation. Through analysis of the separated materials, it was concluded that a very high separation of the two materials was achieved. TGA and FTIR confirmed that the material separated from the vent was 100% PET. The material removed from the die was composed of 90% LLDPE and 10% PET.

36 MATERIALS SCIENCE↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗