Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FUEL ASSEMBLIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Nuclear thermal rockets - Key to moon-Mars exploration

The Space Exploration Initiative (SEI) calls for lunar and Martian exploration missions for which solid-core nuclear thermal rockets (NTRs), in virtue of their single-stage, fully-reusable nature, are ideally suited. NTRs promise double the specific impulse of chemical propulsion. A lunar mission employing a reusable NTR is currently being conducted by NASA. The NTR would be assembled in LEO in such a way that it remained 'radioactively cold' during earth-to-orbit deployment by a heavy-lift chemical booster, and therefore presented no radioactive hazard. Also under consideration is a particle-bed reactor in which the hydrogen propulsive fluid directly cools coated-particle fuel spheres.

Borowski, Stanley K.↗

Multi-atom Pt and PtRu catalysts for high performance AEMFCs with ultra-low PGM content

To reduce the platinum group metal (PGM) loading in anion exchange membrane fuel cells (AEMFCs), it is important to transition to catalysts with very low PGM content, and eventually to catalysts that are completely PGM-free. Here, in this work, four supported low-PGM Pt and PtRu catalysts were prepared using a new, simple, scalable technique: Controlled Surface Tension (CST) method. CST allows for a high density of very small multi-atom clusters. Catalysts were physically characterized using a wide array of techniques and tested for their ORR and HOR activity both ex-situ and integrated into operating AEMFCs. The PGM loading was reduced by a factor of 14 while achieving comparable performance to commercial catalysts. AEMFCs were also assembled with ultralow PGM loading (0.05 mgPGM cm -2 ), where PtRu anodes were paired with Fe–N–C cathodes to achieve a specific power of 25 W/mg PGM (40 W/mg Pt ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal and Deactivation of Bond Sodium from Fast Reactor Blanket Materials

The disposition of sodium-bonded spent nuclear fuel and blanket materials in a repository is complicated by the presence of sodium metal that is used as a thermal bond between the uranium metal fuel and blanket slugs and their cladding. The concern is that the metallic sodium could react with water, producing explosive hydrogen gas, or could exhibit a pyrophoric character. Thus, experimental studies were performed to investigate and demonstrate the removal and deactivation of bond sodium from blanket material in a dry environment. Specifically, bond sodium was removed from unirradiated Fermi-1 blanket elements and an assembly via a melt-drain-evaporate process using elevated temperature and reduced pressure. The effectiveness of sodium metal removal from the blanket materials and their associated cladding was =99.9998%, based on post-test quantitative analyses. The separated sodium metal was collected and subsequently deactivated by reacting it in a molten state with a controlled addition of ammonium chloride particles atop a molten salt medium. In this process sodium chloride is formed and assimilates into the salt pool. The subsequent deactivation of the bond sodium produced a solid ingot of sodium chloride, potassium chloride, lithium chloride, and cesium chloride that was devoid of sodium metal based on post-test analyses of the salt product. Both the sodium removal and deactivation operations were conducted within a dry inert atmosphere enclosure. The results of this study substantiate a path forward for the disposition of sodium-bonded blanket materials, including 34 metric tons heavy metal in irradiated Fermi-1 blanket material currently stored at Idaho National Laboratory.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ formed catalysts for active, durable, and thermally stable ammonia protonic ceramic fuel cells at 550 °C

Ammonia protonic ceramic fuel cells (NH 3 -PCFCs) are promising and attractive energy-conversion devices owing to their high energy density, zero-carbon emission, and safety. The development of NH 3 -PCFCs, however, depends largely on the insufficient activity and poor durability of typical Ni-based anodes for ammonia decomposition, especially at low temperatures such as 550 °C. Herein, we report a self-assembled heterostructured Ru 0.95 Cu 0.05 Ni x (RCN) catalyst obtained through an in situ reaction between the surface-decorated Ru 0.95 Cu 0.05 nanoparticles and the Ni grain in the anode under typical processing conditions. At 550 °C, Ni–BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3 anode-supported PCFCs with RCN catalysts exhibit a high peak power density of 0.732 W cm -2 and a significantly enhanced durability of 100 h in NH 3 . Moreover, the cells demonstrate improved thermal stability compared with the bare cell during a 31-cycle thermal cycling test in NH 3 between 550 and 700 °C. In conclusion, the enhanced performance is likely attributed to the synergistic effects of Ru and Cu in RCN for NH 3 decomposition, resulting in a more vital interaction of NH 3 than that of the bare anode surfaces, as confirmed by NH 3 thermal conversion, electrochemical performance, and theoretical simulations.

30 DIRECT ENERGY CONVERSION↗

Along-the-channel modeling and analysis of PEFCs at low stoichiometry: Development of a 1+2D model

Water management remains a key challenge in polymer-electrolyte fuel cells. In this paper, a pseudo 3-D (1+2D) model is developed to account better for changes of water management along the channel, as well as verify the possibilities of using differential cells for data capture and translation to integral cell performance. An accurate 2-D membrane-electrode-assembly model is developed for differential cell modeling, which is combined with an along-the-channel stepping algorithm to account for down the channel changes in pressure, temperature, reactant concentration, and relative humidity. Variations in cell performance along the channel due to changes in operating conditions are characterized quantitatively and optimized, where drier feed conditions demonstratively require such an approach. In conclusion, the study identifies gaps between differential and integral cells including those related to flow velocity and highlights the need for better models to understand and link integral cell performance and water management.

30 DIRECT ENERGY CONVERSION↗

2019 Anion Exchange Membrane Workshop Summary Report

The National Renewable Energy Laboratory, in coordination with the U.S. Department of Energy Fuel Cell Technologies Office, Advanced Research Projects Agency–Energy, and Los Alamos National Laboratory, hosted the 2019 Anion Exchange Membrane Workshop at the Sheraton Dallas Hotel in Dallas, Texas, on May 30, 2019. More than 50 industrial, academic, national laboratory, and government experts representing the needs of anion exchange membranes, membrane electrode assemblies, and system and stack components attended the workshop.

30 DIRECT ENERGY CONVERSION↗

Climate Influences on Capacity Expansion Planning with Application to the Western U.S

Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.

13 HYDRO ENERGY↗

High Pressure Hydrogen Nozzle Assembly and Dispenser for Heavy Duty Vehicles (Final Technical Report)

Electricore, Inc. along with partners Bennett Pump Company (Bennett), WEH Technologies, Inc. (WEH), National Renewable Energy Laboratory (NREL), and Quong & Associates, Inc. (QAI) have developed a high-pressure hydrogen nozzle assembly and dispenser for heavy-duty (HD) vehicles. The system was installed, tested and demonstrated at NREL’s Hydrogen Infrastructure Testing and Research Facility (HITRF). The system was designed to have a maximum operating pressure of 87.5 MPa and an approximate average flow rate of 10 kg/min over 10 minutes at fuel temperatures of -40°C. To further develop the specifications and design of the system, the team performed an industry survey to ensure the system met the needs of potential users.

08 HYDROGEN↗

A Development of Critical Components for the Modular Staged Pressurized Oxy-Combustion Power Plant

DOE's Coal FIRST (Flexible, Innovative, Resilient, Small, Transformative) Initiative was implemented to encourage the development of the coal plant of the future, which will be capable of flexible operation to meet the needs of the grid; using innovative and cutting-edge components that improve efficiency and reduce emissions; providing resilient power to Americans; being small compared to today's conventional utility-scale coal power plants; and transforming how coal power plant technologies are designed and manufactured. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gases removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from TRL 4 to TRL-5, which would allow them to be subsequently incorporated into a pilot plant. These units are the only two components that are not commercially available for a SPOC plant, and hence, their development is a key step toward the commercialization of SPOC. This work presents the objectives, task descriptions, and current progress of the project. So far, the fabrication of a new combustor design and the convective heat transfer boiler has been completed, and the integration of the combustor, boiler, and DCC is underway. Recent results obtained with the newly designed combustor show a stable coal/methane flame while dry-feeding PRB coal under oxy-combustion conditions.

Magalhaes, Duarte↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Critical to the future of power generation is the development of a power plant that will be capable of flexible operation to meet the needs of the modern grid, providing resilient, low-emissions power to a grid that is increasingly seeing a large penetration of intermittent wind and solar. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gas removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from Technology Readiness Level (TRL) 4 to TRL-5, which would allow these technologies to be subsequently incorporated into a pilot plant. This talk will present an overview of the SPOC technology, CFD modeling and validation for burner and boiler development, and recent results to evaluate critical components for system integration needed to advance its TRL.

Magalhaes, Duarte↗

Development of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass

Critical to the future of power generation is the development of a power plant that will be capable of flexible operation to meet the needs of the modern grid, providing resilient, low-emissions power to a grid that is increasingly seeing a large penetration of intermittent wind and solar. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gases removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from Technology Readiness Level (TRL) 4 to TRL-5, which would allow these technologies to be subsequently incorporated into a pilot plant. This talk will present an overview of the SPOC technology, CFD modeling and validation for burner and boiler development, and recent results to evaluate critical components needed to advance its TRL.

Magalhaes, Duarte↗

Phase segregation of a composite air electrode unlocks the high performance of reversible protonic ceramic electrochemical cells

One breakthrough in developing highly efficient air electrodes for reversible protonic ceramic electrochemical cells (R-PCECs) is optimizing the sluggish oxygen reduction and water oxidation reactions. Here, we present a novel composite material with a nominal formula of high-entropy Ce 0.2 Ba 0.2 Sr 0.2 La 0.2 Ca 0.2 CoO 3–δ (CBSLCC) that spontaneously self-assembles to three-phase electrocatalysts composed of deficient Ce 0.2–y Ba 0.2 Sr 0.2–x La 0.2–x Ca 0.2 CoO 3–δ (CD-CBSLCC), CeO 2 , and La 0.5 Sr 0.5 CoO 3–δ (LSC). Mechanistic studies corroborate that oxygen reduction may occur on entire air electrode surfaces, followed by water formation preferentially at or near CD-CBSLCC. The CeO 2 phase could provide or consume protons to facilitate the oxygen evolution/reduction kinetics in R-PCECs. The developed electrodes demonstrate a record-high electrochemical performance in dual modes of fuel cells and electrolysis cells, delivering a peak power density of 1.66 W cm –2 at 600 °C and a current density of –1.76 A cm –2 at 1.3 V and 600 °C. Finally, excellent operational stabilities of the fuel cell (200 h at 600 °C), electrolysis cell (200 h at 600 °C), and reversible cycling (548 h at 550 °C) provide a promising and reliable step towards realizing the commercialization of R-PCECs.

30 DIRECT ENERGY CONVERSION↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report - FY2019

This report documents the operations and testing that was performed at the Mechanisms Engineering Test Loop (METL) during FY2019. The METL facility had a very successful initial year of operations having logged over 365 days of operations with molten sodium either flowing or static. FY2019 saw the commissioning, insertion, and extraction of the first test assembly in METL. In addition, METL is being prepared to support a second experiment, a thermal hydraulic experiment, called Thermal Hydraulic Experimental Test Article (THETA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of High Fidelity, Fuel-Like Thermal Simulators for Non-Nuclear Testing

This viewgraph presentation reviews the development of a simulator for non-nuclear tests for the development of a space nuclear power system. The development of the Instrumented Thermal Simulator is to assist in developing an understanding of individual components and integrated system operation without the cost, time, safety concerns associated with nuclear testing. The presentation shows the design, the electrical integration, the hardware, and the assembly of the simulators. There are slides that show the test plan, the analysis, and the initial results.

Bragg-Sitton, Shannon↗

A Full-Cell Model for Direct Toluene Electro-Hydrogenation Electrolysis

Liquid organic hydrogen carriers (LOHCs) are organic molecules that undergo a hydrogenation/dehydrogenation cycle to enable storage and transportation of hydrogen fuel under ambient conditions. One promising LOHC candidate is toluene, which can be converted to methylcyclohexane (MCH) electrochemically, enabling a decarbonized process when green electricity is used. In this study, we developed a full-cell model for the direct electro-hydrogenation of toluene to MCH, utilizing a zero-gap membrane electrode assembly architecture. The model incorporates electrochemical kinetics, ionic transport, water transport across the membrane, and mass transport effects. Electrochemical kinetics are characterized using Tafel analysis on Pt/Ru catalyst. The model is validated against experimental data, including polarization curves, Faradaic efficiencies, and water crossover. A voltage breakdown analysis shows that the performance is dominated by kinetic losses, and the model is used to carry out a comparison of different toluene electro-hydrogenation reaction catalysts. Finally, a sensitivity analysis is conducted on key design parameters illustrating which can be modified to maximize electrolyzer performance. The cathode specific surface area and cathode porous transport layer thickness (PTL) have the largest impact on the current density, while the PTL thickness and Pt loading in the PTL have the largest impact on Faradaic efficiency.

Ehlinger, Victoria M. [Lawrence Livermore National↗

Nuclear Weapons Production – Materials Cycle [Slides]

Presentation Overview: This presentation will familiarize participants with the production of plutonium, its separation, conversion to metal, casting, machining, and assembly of special nuclear materials common to nuclear weapons, and the disposal of nuclear waste. Focus in this talk is plutonium (in future briefings we will broaden to include other materials).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flattop Free-Run [Slides]

Objectives: Awareness of the Flattop critical assembly design and intent; Obtain a working knowledge of how changes in reflector geometry can affect the criticality of a system; and, Observe the effects of temperature-dependent reactivity feedback.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test experience, 490 N high performance (321 sec Isp) engine

Engines with area ratios of 44:1 and 286:1 are tested by means of hot fire tests using the NTO/MMH bipropellant to maximize the performance of the combined technologies. The low-thrust engine systems are designed with oxidation resistant materials that can operate at temperatures of more than 2204 C for tens of hours. The chamber is attached to the injector in a configuration that prevents overheating of the injector, valve, and the spacecraft interface. Three injectors with 44:1 area ratios are capable of nominal specific impulse values of 309 sec, and a performance of 321 lbf-sec/lbm is noted for an all-welded engine assembly with area ratio of 286:1. The all-welded engine is shown to have an acceptable design margin for thermal characteristics. High-performance liquid apogee engines are shown to perform optimally when based on iridium/rhenium chamber technology, use of a special platelet injector, and the minimization of losses due to fuel-film cooling.

Schoenman, L.↗