Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

WE-E-9A-01: Ultrasound Elasticity

Principles and techniques of ultrasound-based elasticity imaging will be presented, including quasistatic strain imaging, shear wave elasticity imaging, and their implementations in available systems. Deeper exploration of quasistatic methods, including elastic relaxation, and their applications, advantages, artifacts and limitations will be discussed. Transient elastography based on progressive and standing shear waves will be explained in more depth, along with applications, advantages, artifacts and limitations, as will measurement of complex elastic moduli. Comparisons will be made between ultrasound radiation force techniques, MR elastography, and the simple A mode plus mechanical plunger technique. Progress in efforts, such as that by the Quantitative Imaging Biomarkers Alliance, to reduce the differences in the elastic modulus reported by different commercial systems will be explained. Dr. Hall is on an Advisory Board for Siemens Ultrasound and has a research collaboration with them, including joint funding by R01CA140271 for nonlinear elasticity imaging. Learning Objectives: Be reminded of the long history of palpation of tissue elasticity for critical medical diagnosis and the relatively recent advances to be able to image tissue strain in response to an applied force. Understand the differences between shear wave speed elasticity measurement and imaging and understand the factors affecting measurement and image frame repletion rates. Understand shear wave propagation effects that can affect measurements, such as essentially lack of propagation in fluids and boundary effects, so important in thin layers. Know characteristics of available elasticity imaging phantoms, their uses and limitations. Understand thermal and cavitational limitations affecting radiation force-based shear wave imaging. Have learning and references adequate to for you to use in teaching elasticity imaging to residents and technologists. Be able to explain how elasticity measurement and imaging can contribute to diagnosis of breast and prostate cancer, staging of liver fibrosis, age estimation of deep veinous fhrombosis, confirmation of thermal lesions in the liver after RF ablation.

60 APPLIED LIFE SCIENCES↗

Seismic velocity changes associated with aseismic deformations of a fault stimulated by fluid injection

Fluid pressure plays an important role in the stability of tectonic faults. However, the in situ mechanical response of faults to fluid pressure variations is still poorly known. To address this question, we performed here a fluid injection experiment in a fault zone in shales while monitoring fault movements at the injection source and seismic velocity variations from a near-distance (<10 m) monitoring network. We measured and located the P and S wave velocity perturbations in and around the fault using repetitive active sources. We observed that seismic velocity perturbations dramatically increase above 1.5 MPa of injection pressure. This is consistent with an increase of fluid flow associated with an aseismic dilatant shearing of the fault as shown by numerical modeling. We find that seismic velocity changes are sensitive to both fault opening by fluid invasion and effective stress variations and can be an efficient measurement for monitoring fluid-driven aseismic deformations of faults.

58 GEOSCIENCES↗

An investigation of a wave-amplitude vacillation using a light-speckle velocity measuring technique

A novel form of streak photography based on a light-speckle technique has been used to investigate wave-amplitude vacillation in a thermally driven rotating cylindrical annulus of fluid. The technique is evaluated and found to be an excellent way to measure a 2-dimensional field of velocity without introducing probes into the fluid. The results are compared with previous work with the exception that the kinetic energy is significantly higher. The relation between eddy and mean motion, momentum transport, and period of the vacillation cycle appear similar in the two studies.

Fitzjarrald, D. E.↗

High-resolution measurements of the DT neutron spectrum using new CD foils in the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ∼200 keV FWHM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical properties of homogeneous and isotropic turbulence in He II measured via particle tracking velocimetry

Despite being a quantum two-fluid system, superfluid helium-4 (He II) is observed to behave similarly to classical fluids when a flow is generated by mechanical forcing. This similarity has brought up the feasibility of utilizing He II for high Reynolds number classical turbulence research, considering the small kinematic viscosity of He II. However, it has been suggested that the nonclassical dissipation mechanism in He II at small scales may alter its turbulent statistics and intermittency. In this work, we report our study of a nearly homogeneous and isotropic turbulence (HIT) generated by a towed grid in He II. We measure the velocity field using particle tracking velocimetry with solidified deuterium particles as the tracers. By correlating the velocities measured simultaneously on different particle trajectories or at different times along the same particle trajectory, we are able to conduct both Eulerian and Lagrangian flow analyses. Spatial velocity structure functions obtained through the Eulerian analysis show scaling behaviors in the inertial subrange similar to that for classical HIT but with enhanced intermittency. The Lagrangian analysis allows us to examine the flow statistics down to below the dissipation length scale. Interestingly, abnormal deviations from the classical scaling behaviors are observed in this regime. Lastly, we discuss how these deviations may relate to the motion of quantized vortices in the superfluid component in He II.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling of injected current stream-induced 3D perturbations in local helicity injection plasmas

Solenoid-free tokamak startup techniques are essential for spherical tokamaks and offer a pathway to cost reduction and design simplification in fusion energy systems. Local helicity injection (LHI) is one such approach, employing compact edge current sources to drive open field line current that initiates and sustains tokamak plasmas. The recently commissioned Pegasus-III Experiment provides a platform for advancing this and other solenoid-free startup methods. This study investigates the effect of LHI on magnetic topology in Pegasus-III plasmas. A helical filament model represents the injected current, and the linear plasma response to its three-dimensional field is calculated with M3D-C1. Poincaré mapping reveals substantial flux surface degradation in all modeled cases. The onset of overlapping magnetic structures and large-scale surface deformation begins near Ψ N ≈ 0.37, indicating a broad region of perturbed topology extending toward the edge. In rotating plasmas, both single-fluid and two-fluid models exhibit partial screening of the n = 1 perturbation, with two-fluid calculations showing stronger suppression near the edge. In contrast, the absence of rotation leads to strong resonant field amplification in the single-fluid case, while the two-fluid case with zero electron rotation mitigates this amplification and preserves edge screening. Magnetic probe measurements indicate that modeling the stream with spatial spreading—representing distributed current and/or oscillatory motion—better reproduces measured magnetic power profiles than a rigid filament model. The results underscore the role of rotation and two-fluid physics in screening stream perturbations and point to plasma flow measurements and refined stream models as key steps toward improving predictive fidelity.

Schaefer, Carolyn E. [Univ. of Wisconsin, Madison,↗

Electric Motor Thermal Management R&D (Presentation)

Thermal constraints place significant limitations on how electric motors ultimately perform. Without the ability to remove heat, the motor cannot operate without sacrificing performance, efficiency, and reliability. Finite element analysis and computational fluid dynamics modeling approaches are being increasingly utilized in the design and analysis of electric motors. As the models become more sophisticated, it is important to have detailed and accurate knowledge of both the passive thermal performance and the active cooling performance. In this work, we provide an overview of research characterizing both passive and active thermal elements related to electric motor thermal management. To better characterize the passive thermal performance, the effective thermal properties and inter-lamination thermal contact resistances were measured for different stator lamination materials. The active cooling performance of automatic transmission fluid (ATF) jets was also measured to better understand the heat transfer coefficients of ATF impinging on motor copper windings. Ford's Mercon LV was the ATF evaluated in this study. The presentation provides an overview of prior work with a focus on describing future plans for research to be performed during FY15.

33 ADVANCED PROPULSION SYSTEMS↗

Inferring thermal ion temperature and residual kinetic energy from nuclear measurements in inertial confinement fusion implosions

In inertial con finement fusion implosion experiments, the presence of residual anisotropic fluid motion within the stagnating hot spot leads to signifi cant variations in ion-temperature measurements using neutron time- of-flight detectors along different lines of sight. The minimum ion-temperature measurement is typically used as representative of the thermal temperature. In the presence of isotropic flows, however, even the minimum DT neutron-inferred ion temperature can be well above the plasma thermal temperature. Using both DD and DT neutron-inferred ion-temperature measurements, we show that it is possible to determine the contribution of isotropic flows and infer the DT burn-averaged thermal ion temperature. The contribution of large isotropic flows on driving the ratio of DD to DT neutron-inferred ion temperatures well below unity and approaching the lower bound of 0.8 is demonstrated in multimode simulations. The minimum DD neutron- inferred ion temperature is determined from the velocity variance analysis, accounting for the presence of isotropic flows. Being close to the DT burn-averaged thermal ion temperature, the inferred DD minimum ion temperatures demonstrate a strong correlation with the experimental yields in the OMEGA implosion database. An analytical expression is also derived to explain the effect of mode ℓ = 1 ion-temperature measurement asymmetry on yield degradations caused by the anisotropic flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of unsteady flow dynamics in therminol-66 using edge tone-induced oscillations

Recent research has demonstrated that flow oscillations induced by a wedge positioned opposite the jet outlet in edge tones can be effectively utilized for flow measurement purposes. This highlights the necessity for developing advanced instrumentation capable of precise flow measurements in experimental setups exposed to radiation and in challenging fluids such as molten salts. Here, this study contributes to the existing body of knowledge by conducting experiments using Therminol-66, an effective surrogate for FLiBe under appropriate temperature conditions for nuclear applications, across a broad range of Reynolds numbers from 17,700 to 555,000. Experiments were conducted with Therminol-66 at approximately 368.8 K under atmospheric pressure, with varying flow rates. A reliable correlation was established between the generated frequencies, corresponding flow rates, and device geometry parameters. The data were subjected to non-dimensional analysis to reveal the interrelationships among flow rate, fluid properties, device geometry, and their impact on the acoustic tones produced by the edge tone device. These findings contribute to the development of precise flow measurement instrumentation for use in challenging environments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Probing flow-induced nanostructure of complex fluids in arbitrary 2D flows using a fluidic four-roll mill (FFoRM)

Abstract Engineering flow processes to direct the microscopic structure of soft materials represents a growing area of materials research. In situ small-angle neutron scattering under flow (flow-SANS) is an attractive probe of fluid microstructure under simulated processing conditions, but current capabilities require many different sample environments to fully interrogate the deformations a fluid experiences in a realistic processing flow. Inspired by recent advances in microfluidics, we present a fluidic four-roll mill (FFoRM) capable of producing tunable 2D flow fields for in situ SANS measurements, that is intended to allow characterization of complex fluid nanostructure under arbitrary complex flows within a single sample environment. Computational fluid dynamics simulations are used to design a FFoRM that produces spatially homogeneous and sufficiently strong deformation fields. Particle tracking velocimetry experiments are then used to characterize the flows produced in the FFoRM for several classes of non-Newtonian fluids. Finally, a putative FFoRM-SANS workflow is demonstrated and validated through the characterization of flow-induced orientation in a semi-dilute cellulose nanocrystal dispersion under a range of 2D deformations. These novel experiments confirm that, for steady state straining flows at moderate strain rates, the nanocrystals orient along the principal strain-rate axis, in agreement with theories for rigid, rod-like Brownian particles in a homogeneous flow.

36 MATERIALS SCIENCE↗

X-ray fluorescence measurements of dissolved gas and cavitation

The dynamics of dissolved gas and cavitation are strongly coupled, yet these phenomena are difficult to measure in-situ. Both create voids in the fluid that can be difficult to distinguish. In this paper, we present an application of X-ray fluorescence in which liquid density and total noncondensible gas concentration (both dissolved and nucleated) are simultaneously measured. The liquid phase is doped with 400 ppm of a bromine tracer, and dissolved air is removed and substituted with krypton. Fluorescent emission at X-ray wavelengths is simultaneously excited from the Br and Kr with a focused monochromatic X-ray beam from a synchrotron source. We measure the flow in a cavitating nozzle 0.5 mm in diameter. From Br fluorescence, total displacement of the liquid is measured. From Kr fluorescence, the mass fraction of both dissolved and nucleated gas is measured. Volumetric displacement of liquid due to both cavitation and gas precipitation can be separated through estimation of the local equilibrium dissolved mass fraction. The uncertainty in the line of sight projected densities of the liquid and gas phases is 4–6 %. The high fluorescence yields and energies of Br and Kr allow small mass fractions of gas to be measured, down to 10 -5 , with an uncertainty of 8 %. Finally, these quantitative measurements complement existing optical diagnostic techniques and provide new insight into the diffusion of gas into cavitation bubbles, which can increase their internal density, pressure and lifetimes by orders of magnitude.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dispersion Validation for Flow Involving a Large Structure

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) is a relatively new technique that leverages diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. The comparison exercise shows good comparison between model and experimental results, with the wake region downstream of the tall building presenting the most significant challenge to the quantitative accuracy of the model. Model uncertainties are assessed through parametric variations. Some observations are made in relation to the future utility of MDV and CFD, and some productive follow-on activities are suggested that can help mature the science of flow modeling and experimental testing.

54 ENVIRONMENTAL SCIENCES↗

Transcapillary fluid shifts in tissues of the head and neck during and after simulated microgravity

To understand the mechanism, magnitude, and time course of facial puffiness that occurs in microgravity, seven male subjects were tilted 6 degrees head down for 8 hr, and all four Starling transcapillary pressures were directly measured before, during , and after tilt. Head-down tilt (HDT) caused facial edema and a significant elevation of microvascular pressures measured in the lower lip. Subcutaneous and intramuscular interstitial fluid pressures in the neck also increased as a result of HDT, while interstitial fluid colloid osmotic pressures remained unchanged. Plasma colloid osmotic pressures dropped significantly after 4 hr of HDT, suggesting a transition from fluid filtration to absorption in capillary beds between the heart and feet during HDT. After 4 hr of seated recovery from HDT, microvascular pressures remained significantly elevated by 5 to 8 mm Hg above baseline values despite a significant HDT diuresis and the orthostatic challenge of an upright, seated posture. During the control (baseline) period, urine output was 46.7 ml/hr; during HDT, it was 126.5 ml/hr.

Hargens, A. R.↗

Radio Frequency Mass Gauging of Propellants

A combined experimental and computer simulation effort was conducted to measure radio frequency (RF) tank resonance modes in a dewar partially filled with liquid oxygen, and compare the measurements with numerical simulations. The goal of the effort was to demonstrate that computer simulations of a tank's electromagnetic eigenmodes can be used to accurately predict ground-based measurements, thereby providing a computational tool for predicting tank modes in a low-gravity environment. Matching the measured resonant frequencies of several tank modes with computer simulations can be used to gauge the amount of liquid in a tank, thus providing a possible method to gauge cryogenic propellant tanks in low-gravity. Using a handheld RF spectrum analyzer and a small antenna in a 46 liter capacity dewar for experimental measurements, we have verified that the four lowest transverse magnetic eigenmodes can be accurately predicted as a function of liquid oxygen fill level using computer simulations. The input to the computer simulations consisted of tank dimensions, and the dielectric constant of the fluid. Without using any adjustable parameters, the calculated and measured frequencies agree such that the liquid oxygen fill level was gauged to within 2 percent full scale uncertainty. These results demonstrate the utility of using electromagnetic simulations to form the basis of an RF mass gauging technology with the power to simulate tank resonance frequencies from arbitrary fluid configurations.

Zimmerli, Gregory A.↗

Probing early-time longitudinal dynamics with the Λ hyperon's spin polarization in relativistic heavy-ion collisions

Here, we systematically study the hyperon global polarization's sensitivity to the collision systems' initial longitudinal flow velocity in hydrodynamic simulations. By explicitly imposing local energy-momentum conservation when mapping the initial collision geometry to macroscopic hydrodynamic fields, we study the evolution of systems' orbital angular momentum (OAM) and fluid vorticity. We find that a simultaneous description of the $\Lambda$ hyperons' global polarization and the slope of pion's directed flow can strongly constrain the size of longitudinal flow at the beginning of hydrodynamic evolution. We extract the size of the initial longitudinal flow and the fraction of orbital angular momentum in the produced QGP fluid as a function of collision energy with the STAR measurements in the RHIC Beam Energy Scan program. We find that there is about 100-200 $\hbar$ OAM that remains in the mid-rapidity fluid at the beginning of hydrodynamic evolution. We further exam the effects of different hydrodynamic gradients on the spin polarization of $\Lambda$ and $\bar{\Lambda}$. The gradients of $\mu_B/T$ can change the ordering between $\Lambda$'s and $\bar{\Lambda}$'s polarization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methodology of Experiment Design for Improving Transient Critical Heat Flux Model Development

One phenomenon that contributes to nuclear fuel and clad failure mechanisms is the departure from nucleate boiling (DNB). Accident scenarios such as reactivity-initiated accidents (RIAs) provide conditions where the frequency of boiling crisis is much more likely to occur and on much shorter time scales than loss of coolant (LOCA) or loss of flow (LOFA) accidents. Here, boiling crisis in the form of DNB is attributed to transient-induced heat flux values that exceed the critical heat flux (CHF). The resulting effects, such as bubble crowding and eventual dryout, can affect flow boiling heat transfer and compromise the structural integrity of nuclear reactor materials. The focus of the work proposed here lies in developing a rigorous process using out-of-pile testing, under simulated RIA conditions, to determine the transient critical heat flux of cladding materials, without contributions from aforementioned radiation-induced effects that have been observed during in-pile experiments. This study provides a road-map for developing and performing experiments that simulate the power profile and energy deposition aspects of transient events, specific to RIAs, on the laboratory scale. The goal of our project is to observe and measure DNB in an annular flow channel around a single heater rod that is operating and nominal thermal hydraulic conditions of a PWR. It is also an aim of these experiments to determine how to quantify the gap between SS and transient CHF cases, based on state-dependent properties of the cladding material type that is being interrogated. Traditionally, CHF is determined as a combination of four factors: hydraulic diameter, system pressure, mass flow, fluid quality. The authors propose that an additional measureable quantity, which is dependent on the structural properties of the cladding material itself, is partly reasonable for the difference between measured and model-developed CHF values. Using a carefully metered approach will allow for several key concepts to be realized: compensation for transient-based effects to current models for CHF; adaptation of current models for different cladding material types, including Gen-IV concept materials; and implementation of a correction factor to account for both power transient-based and radiation-induced effects on the CHF that have not yet been accounted for.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fluid acquisition system for superfluid helium

To enable the resupply of liquid helium users on orbit, the technology for helium transfer in space is being developed. A key element of the resupply process is the fluid acquisition in the supply dewar; feeding the liquid to the pump. For the Superfluid Helium On-Orbit Transfer (SHOOT) flight experiment a number of fluid acquisition techniques have been examined. Subscale tests performed in one gravity on two of the candidates are described. The hope is that these results may be scaled to much larger systems in low gravity. These two types are a screened channel device and a capillary device. Flow rates versus negative head height are presented. Difficulties with each device and the test environment are explained. Some of the measurements to be made on orbit on the fluid acquisition for SHOOT are described.

Dipirro, M. J.↗

Nanoscopic dynamics of phospholipid in unilamellar vesicles: Effect of gel to fluid phase transition

Dynamics of phospholipids in unilamellar vesicles (ULV) is of interest in biology, medical, and food sciences since these molecules are widely used as biocompatible agents and a mimic of cell membrane systems. We have investigated the nanoscopic dynamics of 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) phospholipid in ULV as a function of temperature using elastic and quasielastic neutron scattering (QENS). The dependence of the signal on the scattering momentum transfer, which is a critical advantage of neutron scattering techniques, allows the detailed analysis of the lipid motions that cannot be carried out by other means. In agreement with a differential scanning calorimetry measurement, a sharp rise in the elastic scattering intensity below ca. 296 K indicates a phase transition from the high-temperature fluid phase to the low-temperature solid gel phase. The microscopic lipid dynamics exhibits qualitative differences between the solid gel phase (in a measurement at 280 K) and the fluid phase (in a measurement at a physiological temperature of 310 K). The data analysis invariably shows the presence of two distinct motions: the whole lipid molecule motion within a monolayer, or lateral diffusion, and the relatively faster internal motion of the DMPC molecule. The lateral diffusion of the whole lipid molecule is found to be Fickian in character, whereas the internal lipid motions are of localized character, consistent with the structure of the vesicles. The lateral motion slows down by an order of magnitude in the solid gel phase, whereas for the internal motion not only the time scale, but also the character of the motion changes upon the phase transition. In the solid gel phase, the lipids are more ordered and undergo uniaxial rotational motion. However, in the fluid phase, the hydrogen atoms of the lipid tails undergo confined translation diffusion rather than uniaxial rotational diffusion. The localized translational diffusion of the hydrogen atoms of the lipid tails is a manifestation of the flexibility of the chains acquired in the fluid phase. Because of this flexibility, both the local diffusivity and the confinement volume for the hydrogen atoms increase linearly from near the lipid s polar head group to the end of its hydrophobic tail. Our results present a quantitative and detailed picture of the effect of the gel-fluid phase transition on the nanoscopic lipid dynamics in ULV. Lastly, the data analysis approach developed here has a potential for probing the dynamic response of lipids to the presence of additional cell membrane components.

59 BASIC BIOLOGICAL SCIENCES↗