Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Modeling noise in global Mølmer-Sørensen interactions applied to quantum approximate optimization

Many-qubit Mølmer-Sørensen (MS) interactions applied to trapped ions offer unique capabilities for quantum information processing, with applications including quantum simulation and the quantum approximate optimization algorithm (QAOA). Here, we develop a physical model to describe many-qubit MS interactions under four sources of experimental noise: vibrational mode frequency fluctuations, laser power fluctuations, thermal initial vibrational states, and state preparation and measurement errors. The model parametrizes these errors from simple experimental measurements, without free parameters. Herein, we validate the model in comparison with experiments that implement sequences of MS interactions on two 171 Yb + ions. The model shows reasonable agreement after several MS interactions as quantified by the reduced chi-squared statistic $χ^{2}_{red}$≈2. As an application we examine MaxCut QAOA experiments on three and six ions. The experimental performance is quantified by approximation ratios that are 91% and 83% of the optimal theoretical values. Our model predicts $0.93^{+0.03}_{-0.02}$ and $0.95^{+0.04}_{-0.03}$, respectively, with disagreement in the latter value attributable to secondary noise sources beyond those considered in our analysis. With realistic experimental improvements to reduce measurement error and radial trap frequency variations, the model achieves approximation ratios that are 99% of the optimal. Incorporating these improvements into future experiments is expected to reveal new aspects of noise for future modeling and experimental improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mass Variance from Archival X-ray Properties of Dark Energy Survey Year-1 Galaxy Clusters

Using archival X-ray observations and a log-normal population model, we estimate constraints on the intrinsic scatter in halo mass at fixed optical richness for a galaxy cluster sample identified in Dark Energy Survey Year-One (DES-Y1) data with the redMaPPer algorithm. We examine the scaling behavior of X-ray temperatures, $T_X$, with optical richness, $\lambda_{RM}$, for clusters in the redshift range $0.2 50\%$ complete for clusters with $\lambda_{RM} > 130$. Regression analysis on the two samples produces consistent posterior scaling parameters, from which we derive a combined constraint on the residual scatter, $\sigma_{\ln Tx | \lambda} = 0.275 \pm 0.019$. Joined with constraints for $T_X$ scaling with halo mass from the Weighing the Giants program and richness--temperature covariance estimates from the LoCuSS sample, we derive the richness-conditioned scatter in mass, $\sigma_{\ln M | \lambda} = 0.30 \pm 0.04\, _{({\rm stat})} \pm 0.09\, _{({\rm sys})}$, at an optical richness of approximately 70. Uncertainties in external parameters, particularly the slope and variance of the $T_X$--mass relation and the covariance of $T_X$ and $\lambda_{RM}$ at fixed mass, dominate the systematic error. The $95\%$ confidence region from joint sample analysis is relatively broad, $\sigma_{\ln M | \lambda} \in [0.14, \, 0.55]$, or a factor ten in variance.

79 ASTRONOMY AND ASTROPHYSICS↗

Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction and resulted in statistically not significantly different segmentation error indices (ANOVA test, significance level of 0.05). Conclusions: All three experts were able to produce liver segmentations with low error rates. User interaction time savings of up to 71% compared to a 2D refinement approach demonstrate the utility and potential of our approach. The system offers a range of different tools to manipulate segmentation results, and some users might benefit from a longer learning phase to develop efficient segmentation refinement strategies. The presented approach represents a generally applicable segmentation approach that can be applied to many medical image segmentation problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Criteria for stochastic pinning control of networks of chaotic maps

This paper investigates the controllability of discrete-time networks of coupled chaotic maps through stochastic pinning. In this control scheme, the network dynamics are steered towards a desired trajectory through a feedback control input that is applied stochastically to the network nodes. The network controllability is studied by analyzing the local mean square stability of the error dynamics with respect to the desired trajectory. Through the analysis of the spectral properties of salient matrices, a toolbox of conditions for controllability are obtained, in terms of the dynamics of the individual maps, algebraic properties of the network, and the probability distribution of the pinning control. We demonstrate the use of these conditions in the design of a stochastic pinning control strategy for networks of Chirikov standard maps. To elucidate the applicability of the approach, we consider different network topologies and compare five different stochastic pinning strategies through extensive numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using Gaia DR2 to constrain local dark matter density and thin dark disk

We use stellar kinematics from the latest Gaia data release (DR2) to measure the local dark matter (DM) density ρ DM in a heliocentric cylinder of radius R= 150 pc and half-height z= 200 pc. We also explore the prospect of using our analysis to estimate the DM density in local substructure by setting constraints on the surface density and scale height of a thin dark disk aligned with the baryonic disk and formed due to dissipative dark matter self-interactions. Performing the statistical analysis within a Bayesian framework for three types of tracers, we obtain ρDM = 0.016 ± 0.010 M ⊙ /pc 3 for A stars; early G stars give a similar result, while F stars yield a significantly higher value. For a thin dark disk, A stars set the strongest constraint: excluding surface densities (5–12) M ⊙ /pc 2 for scale heights below 100 pc with 95% confidence. The upper bound of this constraint implies ≲ 1% of the Milky Way DM mass is present in a dissipative dark sector. Comparing our results with those derived using Tycho-Gaia Astrometric Solution (TGAS) data, we find that the uncertainty in our measurements of the local DM content is dominated by systematic errors that arise from assumptions of our dynamical analysis in the low z region. Furthermore, there will only be a marginal reduction in these uncertainties with more data in the Gaia era. We comment on the robustness of our method and discuss potential improvements for future work.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck constraints on holographic dark energy

We perform a detailed investigation on the cosmological constraints on the holographic dark energy (HDE) model by using the Plank data. We find that HDE can provide a good fit to the Plank high-l (l ∼> 40) temperature power spectrum, while the discrepancy at l ≅ 20-40 found in the ΛCDM model remains unsolved in the HDE model. The Plank data alone can lead to strong and reliable constraint on the HDE parameter c. At the 68% confidence level (CL), we obtain c = 0.508 ± 0.207 with Plank+WP+lensing, favoring the present phantom behavior of HDE at the more than 2σ CL. By combining Plank+WP with the external astrophysical data sets, i.e. the BAO measurements from 6dFGS+SDSS DR7(R)+BOSS DR9, the direct Hubble constant measurement result (H{sub 0} = 73.8 ± 2.4 kms{sup −1}Mpc{sup −1}) from the HST, the SNLS3 supernovae data set, and Union2.1 supernovae data set, we get the 68% CL constraint results c = 0.484 ± 0.070, 0.474 ± 0.049, 0.594 ± 0.051, and 0.642 ± 0.066, respectively. The constraints can be improved by 2%-15% if we further add the Plank lensing data into the analysis. Compared with the WMAP-9 results, the Plank results reduce the error by 30%-60%, and prefer a phantom-like HDE at higher significant level. We also investigate the tension between different data sets. We find no evident tension when we combine Plank data with BAO and HST. Especially, we find that the strong correlation between Ω{sub m}h{sup 3} and dark energy parameters is helpful in relieving the tension between the Plank and HST measurements. The residual value of χ{sup 2}{sub Plank+WP+HST}−χ{sup 2}{sub Plank+WP} is 7.8 in the ΛCDM model, and is reduced to 1.0 or 0.3 if we switch the dark energy to w model or the holographic model. When we introduce supernovae data sets into the analysis, some tension appears. We find that the SNLS3 data set is in tension with all other data sets; for example, for the Plank+WP, WMAP-9 and BAO+HST, the corresponding Δχ{sup 2} is equal to 6.4, 3.5 and 4.1, respectively. As a comparison, the Union2.1 data set is consistent with these three data sets, but the combination Union2.1+BAO+HST is in tension with Plank+WP+lensing, corresponding to a large Δχ{sup 2} that is equal to 8.6 (1.4% probability). Thus, combining internal inconsistent data sets (SNIa+BAO+HST with Plank+WP+lensing) can lead to ambiguous results, and it is necessary to perform the HDE data analysis for each independent data sets. Our tightest self-consistent constraint is c = 0.495 ± 0.039 obtained from Plank+WP+BAO+HST+lensing.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal calibration accuracy for gravitational-wave detectors

Calibration errors in the response function of a gravitational-wave detector degrade its ability to detect and then to measure the properties of any detected signals. This paper derives the needed levels of calibration accuracy for each of these data-analysis tasks. The levels derived here are optimal in the sense that lower accuracy would result in missed detections and/or a loss of measurement precision, while higher accuracy would be made irrelevant by the intrinsic noise level of the detector. Calibration errors affect the data-analysis process in much the same way as errors in theoretical waveform templates. The optimal level of calibration accuracy is expressed therefore as a joint limit on modeling and calibration errors: increased accuracy in one reduces the accuracy requirement in the other.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Two-Step Approach to Uncertainty Quantification of Core Simulators

For the multiple sources of error introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily to quantify the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the “two-step” method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the two-step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution was examined in the framework of phase I-3 of the OECD Uncertainty Analysis in Modeling benchmark. With the Three Mile Island Unit 1 core as a base model for analysis, the XSUSA and two-step methods were applied with certain limitations, and the results were compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions were drawn as to the method that is currently more viable for computing uncertainties in burnup and transient calculations.

Yankov, Artem↗

Theoretical study of the accuracy of the pulse method, frontal analysis, and frontal analysis by characteristic points for the determination of single component adsorption isotherms

The adsorption isotherms of selected compounds are our main source of information on the mechanisms of adsorption processes. Thus, the selection of the methods used to determine adsorption isotherm data and to evaluate the errors made is critical. Three chromatographic methods were evaluated, frontal analysis (FA), frontal analysis by characteristic point (FACP), and the pulse or perturbation method (PM), and their accuracies were compared. Using the equilibrium-dispersive (ED) model of chromatography, breakthrough curves of single components were generated corresponding to three different adsorption isotherm models: the Langmuir, the bi-Langmuir, and the Moreau isotherms. For each breakthrough curve, the best conventional procedures of each method (FA, FACP, PM) were used to calculate the corresponding data point, using typical values of the parameters of each isotherm model, for four different values of the column efficiency (N = 500, 1000, 2000, and 10,000). Then, the data points were fitted to each isotherm model and the corresponding isotherm parameters were compared to those of the initial isotherm model. When isotherm data are derived with a chromatographic method, they may suffer from two types of errors: (1) the errors made in deriving the experimental data points from the chromatographic records; (2) the errors made in selecting an incorrect isotherm model and fitting to it the experimental data. Both errors decrease significantly with increasing column efficiency with FA and FACP, but not with PM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optoelectronic and excitonic properties of oligoacenes and one-dimensional nanostructures.

The optoelectronic and excitonic properties in a series of linear acenes are investigated using range-separated methods within time-dependent density functional theory (TDDFT). In these highly-conjugated systems, we find that the range-separated formalism provides a substantially improved description of excitation energies compared to conventional hybrid functionals, which surprisingly fail for the various low-lying valence transitions. Moreover, we find that even if the percentage of Hartree-Fock exchange in conventional hybrids is re-optimized to match wavefunction-based CC2 benchmark calculations, they still yield serious errors in excitation energy trends. Based on an analysis of electron-hole transition density matrices, we also show that conventional hybrid functionals overdelocalize excitons and underestimate quasiparticle energy gaps in the acene systems. The results of the present study emphasize the importance of a range-separated and asymptotically-correct contribution of exchange in TDDFT for investigating optoelectronic and excitonic properties, even for these simple valence excitations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scripted Building Energy Modeling and Analysis: Preprint

Building energy modeling and analysis is currently a time-intensive, error-prone, and nonreproducible process. This paper describes the scripting platform of the OpenStudio tool suite (http://openstudio.nrel.gov) and demonstrates its use in several contexts. Two classes of scripts are described and demonstrated: measures and free-form scripts. Measures are small, single-purpose scripts thatconform to a predefined interface. Because measures are fairly simple, they can be written or modified by inexperienced programmers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was related to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique

Purpose: To develop a technique that assesses the accuracy of the breathing phase-specific volume image generation process by patient-specific breathing motion model using the original free-breathing computed tomographic (CT) scans as ground truths. Methods: Sixteen lung cancer patients underwent a previously published protocol in which 25 free-breathing fast helical CT scans were acquired with a simultaneous breathing surrogate. A patient-specific motion model was constructed based on the tissue displacements determined by a state-of-the-art deformable image registration. The first image was arbitrarily selected as the reference image. The motion model was used, along with the free-breathing phase information of the original 25 image datasets, to generate a set of deformation vector fields that mapped the reference image to the 24 nonreference images. The high-pitch helically acquired original scans served as ground truths because they captured the instantaneous tissue positions during free breathing. Image similarity between the simulated and the original scans was assessed using deformable registration that evaluated the pointwise discordance throughout the lungs. Results: Qualitative comparisons using image overlays showed excellent agreement between the simulated images and the original images. Even large 2-cm diaphragm displacements were very well modeled, as was sliding motion across the lung–chest wall boundary. The mean error across the patient cohort was 1.15 ± 0.37 mm, and the mean 95th percentile error was 2.47 ± 0.78 mm. Conclusion: The proposed ground truth–based technique provided voxel-by-voxel accuracy analysis that could identify organ-specific or tumor-specific motion modeling errors for treatment planning. Despite a large variety of breathing patterns and lung deformations during the free-breathing scanning session, the 5-dimensionl CT technique was able to accurately reproduce the original helical CT scans, suggesting its applicability to a wide range of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A systematic decision-making methodology to formalize the selection of degree of realism in screening analysis of probabilistic risk assessment

In the nuclear power domain, Probabilistic Risk Assessment (PRA) is used to inform decision-making for Nuclear Power Plants (NPPs). Recently, there has been an increase in the utilization of modeling and simulation (M&S) to support the estimation of PRA inputs. Risk analysts should carefully select the PRA items that require M&S and their degree of realism (DoR) with consideration of the required resources. To support this selection, this article formulates a systematic decision-making approach for the DoR selection. The DoR selection is made based on two predictive decision-making attributes: the predicted differences in safety risk estimate (ΔSaRi) and the cost of analysis (ΔCAN). This research also develops and quantifies causal models to estimate ΔSaRi and ΔCAN. The causal model-based prediction of ΔSaRi and ΔCAN helps reduce the trial-and-error nature of the DoR selection in the PRA screening analysis and provides insights for DoR selection and the gradual refinements of PRA realism. This approach is demonstrated for a case study on fire PRA of NPPs, where an adequate DoR is selected from two fire models: an engineering correlation and a zone model.

Alkhatib, Sari [Department of Nuclear, Plasma, and↗

THE IDENTIFICATION OF THE X-RAY COUNTERPART TO PSR J2021+4026

We report the probable identification of the X-ray counterpart to the {gamma}-ray pulsar PSR J2021+4026 using imaging with the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer and timing analysis with the Fermi satellite. Given the statistical and systematic errors, the positions determined by both satellites are coincident. The X-ray source position is R.A. 20{sup h}21{sup m}30.{sup s}733, decl. +40 Degree-Sign 26'46.''04 (J2000) with an estimated uncertainty of 1.''3 combined statistical and systematic error. Moreover, both the X-ray to {gamma}-ray and the X-ray to optical flux ratios are sensible assuming a neutron star origin for the X-ray flux. The X-ray source has no cataloged infrared-to-visible counterpart and, through new observations, we set upper limits to its optical emission of i' > 23.0 mag and r' > 25.2 mag. The source exhibits an X-ray spectrum with most likely both a power law and a thermal component. We also report on the X-ray and visible light properties of the 43 other sources detected in our Chandra observation.

79 ASTRONOMY AND ASTROPHYSICS↗

HOD-dependent systematics in Emission Line Galaxies for the DESI 2024 BAO analysis

The Dark Energy Spectroscopic Instrument (DESI) will provide precise measurements of Baryon Acoustic Oscillations (BAO) to constrain the expansion history of the Universe and set stringent constraints on dark energy. Therefore, precise control of the global error budget due to various systematic effects is required for the DESI 2024 BAO analysis. In this work, we estimate the level of systematics induced in the DESI BAO analysis due the assumed Halo Occupation Distribution (HOD) model for the Emission Line Galaxy (ELG) tracer. We make use of mock galaxy catalogs constructed by fitting various HOD models to early DESI data, namely the One-Percent survey data. Our analysis includes typical HOD models for the ELG tracer used in the literature as well as extensions to the baseline models. Among the extensions, we consider various recipes for galactic conformity and assembly bias. We use 25 AbacusSummit simulations under the ΛCDM cosmology for each HOD model and perform independent analyses in Fourier space and in configuration space. To recover the BAO signal from our mocks we perform BAO reconstruction and apply the control variates technique to reduce sample variance noise. Our BAO analyses can recover the isotropic BAO parameter α iso within 0.1% and the Alcock Paczynski parameter α AP within 0.3%. Overall, we find that the systematic error due to the HOD dependence is below 0.17%, with the Fourier space analysis being more robust against the HOD systematics. We conclude that our analysis pipeline is robust enough against the HOD systematics for the ELG tracer in the DESI 2024 BAO analysis, for the assumptions made.

79 ASTRONOMY AND ASTROPHYSICS↗