Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electric Generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation of 15% and 50% Thermal Power Dispatch to an Industrial Facility Using a Flexible Generic Full-Scope Pressurized Water Reactor Plant Simulator

Nuclear power plants in the United States are increasingly challenged to compete in wholesale electricity markets due to the low electricity costs and increasingly dynamic grid conditions from competing generation sources. An alternative market for nuclear power is industrial facilities that can use the thermal and/or electrical power generated by a nuclear power plant to offset the economic losses incurred by electricity market challenges. A generic pressurized water reactor (PWR) simulator was used to show the results of a basic design for a generic thermal power extraction system and tests were run using a set of procedures to show what happens when a nuclear power plant transitions from full electrical power dispatch to 15% and 50% thermal power dispatch. This type of operation leads to losses in turbine performance efficiency due to the deviation from the design operating point, but because the thermal power is also used by the industry load without conversion losses, the combined thermal efficiency of the PWR increases. For the 15% case, the thermal efficiency increased from 32% to 41.9%, while for the 50% case, the efficiency increased up to 60.1%. In addition, for 50% thermal power dispatch, the power dissipated by the condenser decreased from approximately 2000 to approximately 1300 MW (thermal), indicating a substantially diminished impact on the environment in terms of releasing heat into the cooling water reservoir.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A next-generation toolset for the life-cycle analysis of electricity use

This works presents an overview--including background, data flow, and case study--of a tool for analyzing impacts utilizing the electricity baseline provided by ElectricityLCI and the impact-modeling techniques of Grid Mix Explorer (along with air and water quality) as a part of a next-generation LCA analytical framework.

Davis, Tyler↗

Geological Thermal Energy Storage Using Solar Thermal and Carnot Batteries: Techno-Economic Analysis: Preprint

Energy storage is increasingly necessary as Variable Renewable Energy (VRE) technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal energy storage (GeoTES) is proposed as a solution for long-term energy storage. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. In this article, we describe a techno-economic model that has been developed to evaluate GeoTES systems. The models are developed by combining the output of specialist models which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models are developed so that the performance can be evaluated at each hour of the year. GeoTES can be charged with two different energy sources: (1) concentrating solar thermal and (2) renewable electricity using heat pumps (henceforth known as a "Carnot Battery"). The stored thermal energy can be used to generate electricity and - uniquely - also directly produce heat that can be used by industrial processes. Furthermore, Carnot-Battery-GeoTES can also be used to form a cold storage reservoir. Preliminary results that quantify the technical and economic performance of these two GeoTES systems are presented.

carnot battery↗

Geological Thermal Energy Storage Using Solar Thermal and Carnot Batteries: Techno-Economic Analysis

Energy storage is increasingly necessary as variable renewable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological thermal energy storage (GeoTES) is proposed as a solution for long-term energy storage. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. In this article, we describe a techno-economic model that has been developed to evaluate GeoTES systems. The models are developed by combining the output of specialist models, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models are developed so that the performance can be evaluated at each hour of the year. GeoTES can be charged with two different energy sources: (1) concentrating solar thermal and (2) renewable electricity using heat pumps (henceforth known as a "Carnot Battery"). The stored thermal energy can be used to generate electricity and, uniquely, also directly produce heat that can be used by industrial processes. Furthermore, Carnot Battery GeoTES can also be used to form a cold storage reservoir. Preliminary results that quantify the technical and economic performance of these two GeoTES systems are presented.

carnot battery↗

A Penalty Scheme for Mitigating Uninstructed Deviation of Generation Outputs From Variable Renewables in a Distribution Market

With rapid growth of distributed renewable generation, the establishment of electricity distribution markets has attracted widespread concerns. Different from existing transmission grid-scale electricity markets, an electricity distribution market is featured by numerous small-scale prosumers, and zero marginal cost and intermittency of renewable generation units. Against this background, this paper first extends an average pricing market (APM) mechanism for pricing renewable generation outputs with zero marginal cost in the distribution network concerned. Then, to mitigate the uninstructed volatility of renewable generation outputs and power demand, a penalty scheme is proposed for deviations between the real-time demand/output and market cleared bid/offer, with frequency regulation service (FRS) from energy storage systems (ESSs) considered. It is proved that the market volatility can be well controlled within an expected limit through properly setting the penalty prices for load demand and generation output fluctuations. Also, with this mechanism a non-negative market surplus could always be attained. Case studies are carried out to demonstrate the feasibility and efficiency of the proposed distribution market mechanism and penalty scheme.

electricity distribution market↗

Role of On-Site Generation in Carbon Emissions and Utility Bill Savings under Different Electric Grid Scenarios

Energy-efficient and sustainable technologies are necessary to lower energy and carbon footprints. Many technologies are being pursued to meet the increasing energy demand in buildings. An attractive option is efficient utilization of available energy resources, including renewables, to support current and future building energy needs while targeting grid resiliency, energy, and environmental security at an affordable cost via on-site cogeneration-based approaches. This must include energy-efficient technologies with lower greenhouse gas emissions and optimized cost, performance, and reliability. This paper presents the economic and environmental benefits associated with power technologies such as thermionics and solid oxide fuel cells. Hybrid configurations consisting of heat pumps, power systems, and renewable photovoltaics in cogeneration and trigeneration modes of operation are presented. The role of such technologies in lowering CO2 emissions while improving energy resiliency and serving the needs of underprivileged communities is discussed. The key barriers of affordability and potential solutions for large-scale implementation of these promising technologies are reviewed. Case studies demonstrating the influence of power rating, electrical efficiency, design configuration, carbon dioxide intensity of the grid, and fuel on annual greenhouse gas emissions are presented for residential and commercial buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to the Special Section on Control and Management of Electric Power Systems With High Shares of Inverter-Based Resources

The growing interest in the integration of variable renewable energy (VRE) and distributed energy resources (DER) on both policy and economic grounds is driving the transformation of electric power systems. The significant deployment of VRE and DER can effectively displace the conventional synchronous generator-based power plants that for decades have been the foundation for power system generation and stability in electric power systems. Inverter-based resources (IBRs) introduce a high-level of uncertainty, variability, and complexity into the operation of electric power networks, and the transformation to IBRs raises a wide range of technical questions and operational challenges. The optimal coordination and control of these resources requires greater interoperability and necessitates significant upgrades of grid automation, including real-time monitoring.

distributed power generation↗

Electric charge build-up and dissipation at pulsed streamer corona by EFISH and probe measurements

The aim of this work is to study the dynamics of volumetric electric charge deposited by a single pin electrode streamer corona in atmospheric air at ambient conditions. Recent studies show that, at pulse-periodic operation, electric charge remains in surrounding air after the first discharge. This residual charge significantly impacts the electric field distribution and morphology of discharges at subsequent pulses. In this study, the residual electrical potential/field was measured during and after dissipation of a pulsed 80kV streamer corona of alternating polarity. This was accomplished using electrostatic probes and the EFISH method (Electric Field Induced Second Harmonic generation). The residual volumetric charge of a positive pulse polarity streamer corona occupies a zone up to 80mm from the electrode. The subsequent application of a negative polarity pulse leads to partial neutralization of the previous charge and the generation of a region with a high-amplitude electric field. Here, the propagation of following positive polarity pulses is limited by the residual positive volumetric charge. The EFISH method reveals the magnitude of the electric field at discharge propagation and electrostatic probes inform the polarity. Intensified imaging acquisition was used to evaluate the spatial distribution and dynamics of corona discharge during the alternating polarity waveform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of CH 4 addition on the electron properties and electric field dynamics in a Ar nanosecond-pulsed dielectric barrier discharge

Non-equilibrium plasmas derive their low temperature reactivity from producing and driving energetic electrons and active species under large electric fields. Therefore, the impact of reactants on the plasma properties including electron number density, electric field, and electron temperature is critical for applications such as plasma CH 4 reforming. Due to experimental complexity, electron properties and the electric field are rarely measured together in the same discharge. Here, we combine time-resolved Thomson scattering and electric field induced second harmonic generation (EFISH) to probe electron temperature, electron density, and electric field strength in a 60 Torr CH 4 /Ar nanosecond-pulsed dielectric barrier discharge (ns-DBD) while varying the CH 4 mole fraction from 0 to 8%. These measurements are compared to a 1-D numerical model to benchmark its predictions and identify areas of uncertainty. Nonlinear coupling between CH 4 addition, electron temperature, electron density, and the electric field was directly observed. Contrary to previous measurements in He, the electron temperature increased with CH 4 mole fraction. This rise in electron temperature is identified as electron heating by residual electric fields that increased with larger CH 4 mole fraction. Moreover, the electron number density has been found to decrease rapidly with the increase of methane mole fraction. Comparison of these measurements with the model yielded better agreement at higher CH 4 mole fractions and with the usage of ab initio calculated Ar electron-impact cross-sections from the B-spline R-matrix (BSR) database. Furthermore, the calculated plasma properties are shown to be sensitive to the residual surface charge implanted on the quartz dielectric surfaces. Without considering surface charge in the simulations, the calculated electric field profiles agreed well with the measurements, but the electron properties were underpredicted by more than a factor of three. Therefore, measurements of either the electric field or electron properties measurements alone are insufficient to fully validate modelling predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sequential versus Simultaneous Aging of XLPE Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables constitute a critical component of nuclear power generation. The aging behavior of electrical cable insulation under combined exposure to thermal and radiation stress is not additive, complicating lifetime prediction of cable performance based on sequential accelerated aging. In this work we explore the relative effects of simultaneous and sequential thermal and gamma radiation aging on cross-linked polyethylene (XLPE), which is commonly found in commercial nuclear power plants in the United States. Samples of XLPE were subjected to up to 320 kGy of gamma irradiation at a dose rate of 300 Gy/hr in two heating scenarios. In the first, simultaneously-aged samples were heated at 150°C during irradiation. In the second, sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation without heating. The mass, total color difference, and density were characterized to quantify aging of the insulation polymer. Sequential aging is hypothesized to be more damaging to XLPE insulation due to an increased trend in mass gain, total color difference, and density.

Cross-linked polyethylene, XLPE, nuclear cable, ac↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Systems and methods for in-situ calibration of scintillation spectrometer

A radiation spectrometer includes a scintillator, a photomultiplier, and one or more light-emitting diodes (LEDs). The scintillator receives radiation from the environment and emits light that is indicative of an energy of the radiation. The photomultiplier receives the light and outputs an electrical signal that is in turn indicative of the energy of the radiation. Spectral data can be generated based upon the electrical signal, wherein the spectral data indicates a number of radiation events in each of several energy bins. The one or more LEDs can emit LED light through the scintillator and toward the photomultiplier, wherein the LED light causes an LED peak in the spectral data that can be used to identify an absolute energy of radiation events in the spectral data.

Pfeifer, Kent B.↗

The Modeling of Synfuel Production Process: ASPEN Model of FT production with electricity demand provided at LWR scale

Synfuels, or electro-fuels (e-fuels) have the unique potential to significantly reduce greenhouse gas (GHG) emissions across the transportation sector. This is especially true for applications with substantial payloads and daily miles traveled, such as long-haul heavy-duty vehicles, rail locomotives, marine vessels and aviation aircrafts that are challenging to directly electrify via battery or fuel cell powertrain technologies. Synfuels, or electro-diesel/electro-jet fuels, have similar properties with the incumbent petroleum fuels, compatible with current infrastructure but have much lower GHG emissions relative to the petroleum counterpart, because they utilize waste carbon dioxide (CO2) streams and green hydrogen (H2) sourced from electrolysis. To achieve substantial reductions in GHG emissions, electricity sources must be zero carbon or near-zero carbon, which is the case with solar, wind, hydro and nuclear power. Compared to the intermittency of solar, wind and hydro, nuclear energy provides a steady energy source. In addition, it’s advantageous for nuclear power to produce synfuels because it provides not only near-zero carbon electricity to displace grid electricity, but also near-zero carbon steam to displace carbon-intensive natural gas combustion for steam generation. The availability of electricity and steam also enables more efficient green hydrogen production by using high-temperature electrolysis. In this work, Argonne National Laboratory (ANL) models a synfuel production process via the Fischer- Tropsch (FT) reaction by using nuclear power to provide electricity and steam. In 2021, using ASPEN Plus software, ANL established a detailed process model of a stand-alone FT production facility, assuming feedstocks of pure CO2 and H2. This stand-alone model can be expanded to integrate H2 production from nuclear power via low-temperature and high-temperature electrolysis at light-water reactor (LWR) scale. This report summarizes the stand-alone ASPEN Plus model results with a detailed mass and energy analysis. Our modeled facility produces 351 MT/day (130,000 gal/day) of FT fuel (a mixture of naphtha, jet fuel, and diesel) by converting 223 MT/day of H2 and 2,387 MT/day of CO2. The FT fuel production energy efficiency is 58% and the carbon conversion efficiency (from CO2 to FT fuel) is 46%. The production of green hydrogen requires 390–470 MWe of electricity, which is compared with the capacity of an LWR plant. For the stand-alone FT process, the detailed energy demand (electricity and heat) is summarized in the table below. Based on the energy supply source and the required temperature, potential insertion points of nuclear energy are identified. Based on the potential nuclear energy utilization, this report discusses potential modification options for expanding the system boundary to integrate nuclear power use, for example on-site hydrogen production via water electrolysis. Modeling of the integrated system is conducted by closely working with ANL and Idaho National Laboratory (INL) collaborators to harmonize design parameters of nuclear plants and the FT production process.

Zang, Guiyan↗

Predicting Electrical Conductivity in Bi-Metal Composites

Generating high magnetic fields requires materials with not only high electric conductivity but also good strength properties in order to withstand the necessarily strong Lorentz forces. A number of bi-metal composites, most notably Cu/Nb, are considered to be good candidates for this purpose. Here, we generalize our previous work on Cu/Nb in order to predict, from theory, the dependence of electric conductivity on the microstructure and volume fraction of the less conductive component for a number of other bi-metal composites. Together with information on strength properties (taken from previous literature), the conductivity information we provide in this work can help to identify new promising candidate materials (such as Cu/Nb, Cu/Ag, Cu/W, …) for magnet applications with the highest achievable field strengths.

36 MATERIALS SCIENCE↗