Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Exploration Systems Exterior Lighting Design Guidance

Humans are returning to the Moon — this time, to stay. NASA has selected a location that maximizes line-of-sight communication with Earth, solar visibility, and access to water ice: the Lunar South Pole (LSP). While the Sun is more consistently in the lunar sky at the poles, it never rises more than 7° above the horizon in the target landing regions. This harsh lighting environment--never experienced during the Apollo missions or in human spaceflight--presents an engineering challenge: Support and protect functional vision. The human vision system, which despite having a high-dynamic range, cannot see well into bright light and cannot adapt quickly from bright to dark or vice versa. The design of helmets, windows, and lighting solutions must work in a complementary fashion to achieve a system of lighting and functional vision support that enables crews to see into darkness while their eyes are light-adapted and see in bright light while still dark-adapted that protects their eyes from injury. This report brings together information and identifies gaps related to LSP Natural environment (topology, regolith, temperature, lighting, and so forth), NASA historical experience exploring the Moon, human vision capabilities and needs, exploration operations, simulation capabilities and needs (for design verification, training, mission planning, and so forth) and existing engineering, safety, medical and performance requirements related to support human exploration.

Simulation↗

Lens-array PDV Probe Using a Pyramid Prism

A bug eye probe is shown using a pyramid prism, and its advantages and disadvantages are enumerated. Also shown is abug eye imaging probe, with its advantages and disadvantages enumerated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extender for securing a closure

An apparatus for securing a closure such as door or a window that opens and closes by movement relative to a fixed structure such as a wall or a floor. Many embodiments provide a device for relocating a padlock from its normal location where it secures a fastener (such as a hasp) to a location for the padlock that is more accessible for locking and unlocking the padlock. Typically an extender is provided, where the extender has a hook at a first end that is disposed through the eye of the staple of the hasp, and at an opposing second end the extender has an annulus, such as a hole in the extender or a loop or ring affixed to the extender. The shackle of the padlock may be disposed through the annulus and may be disposed through the eye of a second staple to secure the door or window in a closed or open position. Some embodiments employ a rigid sheath to enclose at least a portion of the extender. Typically the rigid sheath has an open state where the hook is exposed outside the sheath and a closed state where the hook is disposed within the sheath.

42 ENGINEERING↗

Concealed identification symbols and nondestructive determination of the identification symbols

The concealing of one or more identification symbols into a target object and the subsequent determination or reading of such symbols through non-destructive testing is described. The symbols can be concealed in a manner so that they are not visible to the human eye and/or cannot be readily revealed to the human eye without damage or destruction of the target object. The identification symbols can be determined after concealment by e.g., the compilation of multiple X-ray images. As such, the present invention can also provide e.g., a deterrent to theft and the recovery of lost or stolen objects.

99 GENERAL AND MISCELLANEOUS↗

Frontal view reconstruction for iris recognition

Iris recognition can be accomplished for a wide variety of eye images by correcting input images with an off-angle gaze. A variety of techniques, from limbus modeling, corneal refraction modeling, optical flows, and genetic algorithms can be used. A variety of techniques, including aspherical eye modeling, corneal refraction modeling, ray tracing, and the like can be employed. Precomputed transforms can enhance performance for use in commercial applications. With application of the technologies, images with significantly unfavorable gaze angles can be successfully recognized.

97 MATHEMATICS AND COMPUTING↗

Off-Angle Iris Correction Methods

In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

iris recognition↗

Three-dimensional radiograph security system

A method and apparatus for displaying a three-dimensional radiograph in a security scanner. A first X-ray image of an object is generated by the security scanner from a first viewpoint. A second X-ray image of the object is generated by the security scanner from a second viewpoint. The first X-ray image and the second X-ray image form a stereogram. The stereogram is displayed by the security scanner on a display system for the security scanner such that a first eye of a viewer sees the first X-ray image in the stereogram and a second eye of the viewer sees the second X-ray image in the stereogram. A parallax between the first viewpoint and the second viewpoint in the stereogram results in a three-dimensional visualization of the object on the display system for the security scanner.

Jimenez, Jr., Edward Steven↗

Technical Performance and Cost Optimization of Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) for Wide-area Surveillance and Identification of Marine Life at Marine Energy Installations

Florida Atlantic University developed an underwater optical monitoring system prototype - Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) - suitable for marine energy full project lifecycle observation (baseline, commissioning, and decommissioning), with an automated real-time classification of marine animals. With precursor 2014 DOE funding (award DE-EE0006787), a prototype UMSLI was demonstrated in a controlled laboratory environment and achieved a TRL 6. This EERE DE-EE0007828 award aimed to both increase the TRL of the UMSLI by improving the technology performance (e.g., increase distance of marine animal target detection capability, add additional species classification capabilities, improve the system performance during the day, etc.) and reduce the cost. The UMSLI presents a novel application of underwater distributed Light Detection And Ranging (LiDAR), an advanced remote sensing method that uses light in the form of laser pulses for an application, this paired with an algorithm provides 360 degrees underwater detection, imaging, and classification of marine life. This solution for underwater monitoring of biota preserves the advantages of traditional optical and acoustic solutions while overcoming many associated disadvantages for marine energy site environmental monitoring, such as difficulties in species detection and classification in low light or night and turbid environments. This new approach is a purposefully designed, reconfigurable adaptation of an existing class 3B laser technology into one UMSLI instrument that can be easily mounted on or around different classes of marine energy equipment, such as devices to capture ocean current energy or wave energy. The system uses relatively low average power, utilizes far-red (> 635nm) laser illumination to be invisible and eye-safe to marine animals, is compact, and cost-effective. The equipment is designed for long-term, maintenance-free operations (i.e., current design is targeting more than 7 days continuous operation), to inherently generate a sparse primary dataset that only includes detected anomalies, and to allow robust real-time automated animal classification and identification with a low data bandwidth requirement. The technology’s overarching goal for application, is a system that can be deployed to collect pre-installation baseline species observations at a proposed marine energy deployment site with minimal post-processing overhead. The envisioned system will also produce high-resolution imagery of marine animals through a wide range of conditions and support automated tracking and notification of the presence of managed animals within established perimeters of marine energy equipment to satisfy deployed marine energy projects’ endangered and threatened species monitoring requirements. Through the current project, we demonstrated the UMSLI prototype in an operational environment and increased the UMSLI’s Technology Readiness Level from 6 to 7. The project resulted in many novel technologies, including: 1) an eye-safe red laser based, low-cost LiDAR system that can detect targets up to 10 meters distance; 2) the GAN-based machine learning underwater LiDAR image enhancement technique (this is the first known application of GAN technique in underwater LiDAR); 3) LiDAR-based real-time automated detection capabilities; and 4) a template matching based automated classification tool. These technologies build a solid foundation for future efforts to develop an extended range electro-optical monitoring system suitable for marine energy deployments. In addition to technology development, a key lesson learned is that addressing regulatory and safety requirements must be front and center in any marine energy monitoring applications.

16 TIDAL AND WAVE POWER↗

Meta-optics-based systems and methods for ocular applications

Meta-lens based ocular imaging, near-eye display, and eye-tracking systems are described. The systems can include a single focusing optic and an integrated circuit that provides illumination light and includes an imaging array. The focusing optic includes meta-atoms formed on a substrate. The systems may have no moving parts and achieve imaging or image-projection fields-of-view approaching or exceeding 180 degrees. Because of their low part count, the systems can be robust and have a very small form factor.

Hu, Juejun↗

The Use of Long-wave Infrared Cameras for Hazardous Waste Remediation - 20457

For over fifty years, infrared cameras have been used in military applications, nondestructive testing, condition monitoring, and predictive maintenance. As infrared cameras continue to become more sophisticated and less expensive, they are providing value in an ever-increasing variety of unique applications, including hazardous waste remediation. This paper describes several instances of how infrared cameras have been used within the US Department of Defense and the US Department of Energy in support of waste remediation projects, including the author's recent use of an infrared camera in support of the Calcine Retrieval Project at the Idaho National Laboratory. Infrared cameras provide images of infrared radiation, or heat energy, which is otherwise invisible to the unaided eye. Infrared radiation is part of the electromagnetic spectrum, which includes visible light. But unlike visible light, infrared has wavelengths longer than the human eye can detect. Infrared is emitted by everything with a temperature above absolute zero (-273 deg. C, or -459 deg. F); the higher the temperature, the greater the infrared thermal radiation, or heat, that is emitted. Even objects that feel cold to us, like ice, emit thermal radiation and can be imaged by infrared cameras. These cameras are typically used to look for abnormally hot or cold spots on a component or target area under normal operating conditions. The method provides a rapid, wide-area, noncontact technique for identifying problems associated with a temperature differential. All infrared cameras can provide qualitative thermal information by displaying relative differences in temperatures within a two-dimensional image. More expensive infrared cameras can also provide quantitative information where an absolute temperature value is assigned to each pixel associated with the displayed two-dimensional image. Proper camera calibration and a solid understanding of heat transfer and thermography techniques are required when using an infrared camera to obtain quantitative information. Case studies outlined in this paper include the rapid, non-intrusive detection of hazardous decontamination solution within one-ton shipping containers at Pine Bluff Arsenal, the non-intrusive identification of residual elemental sodium within the cooling loops of the Experimental Breeder Reactor II (EBR-II) reactor at the Idaho National Laboratory, process monitoring of heat exchanger melt-and-drain efforts during EBR-II decommissioning, and the remote detection of internal steel supports within calcine storage bins prior to bin penetration. For each use of thermography, the author describes a summary of the waste remediation effort, the infrared camera used, the thermal imaging technique employed, and the results obtained. The paper concludes with a discussion on common mistakes to avoid for similar applications of thermography. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust pupil center detection using a curvature algorithm

Determining the pupil center is fundamental for calculating eye orientation in video-based systems. Existing techniques are error prone and not robust because eyelids, eyelashes, corneal reflections or shadows in many instances occlude the pupil. We have developed a new algorithm which utilizes curvature characteristics of the pupil boundary to eliminate these artifacts. Pupil center is computed based solely on points related to the pupil boundary. For each boundary point, a curvature value is computed. Occlusion of the boundary induces characteristic peaks in the curvature function. Curvature values for normal pupil sizes were determined and a threshold was found which together with heuristics discriminated normal from abnormal curvature. Remaining boundary points were fit with an ellipse using a least squares error criterion. The center of the ellipse is an estimate of the pupil center. This technique is robust and accurately estimates pupil center with less than 40% of the pupil boundary points visible.

Non-NASA Center↗

Automated Segmentation and Quantification of Drusen in Fundus and Optical Coherence Tomography Images for Detection of ARMD

Age-related macular degeneration (ARMD) is one of the most common retinal syndromes that occurs in elderly people. Different eye testing techniques such as fundus photography and optical coherence tomography (OCT) are used to clinically examine the ARMD-affected patients. Many researchers have worked on detecting ARMD from fundus images, few of them also worked on detecting ARMD from OCT images. However, there are only few systems that establish the correspondence between fundus and OCT images to give an accurate prediction of ARMD pathology. In this paper, we present fully automated decision support system that can automatically detect ARMD by establishing correspondence between OCT and fundus imagery. The proposed system also distinguishes between early, suspect and confirmed ARMD by correlating OCT B-scans with respective region of the fundus image. In first phase, proposed system uses different B-scan based features along with support vector machine (SVM) to detect the presence of drusens and classify it as ARMD or normal case. In case input OCT scan is classified as ARMD, region of interest from corresponding fundus image is considered for further evaluation. The analysis of fundus image is performed using contrast enhancement and adaptive thresholding to detect possible drusens from fundus image and proposed system finally classified it as early stage ARMD or advance stage ARMD. The proposed system is tested on local data set of 100 patients with100 fundus images and 6800 OCT B-scans. Proposed system detects ARMD with the accuracy, sensitivity, and specificity ratings of 98.0, 100, and 97.14%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

Structural and functional characterization of a missense mutant of human γS-crystallin associated with dominant infantile cataracts

Highlights: • We present structural analysis of γS-Y67N, a cataract-active mutant of human γS-crystallin. • Mutation alters the energetics and kinetics of γS-Y67N underlying structural changes. • Aggregation is enhanced and Ca{sup 2+} binding is compromised as a result of mutation. • We explore the structure-function relationship in human γS-crystallin in health and disease. Infantile cataracts constitute one of the most important causes of childhood blindness worldwide. Human γS-crystallin is the most abundant protein in the eye lens cortex. A missense mutant of human γS-crystallin, Y67N (abbreviated hereafter as γS-Y67N) is recently reported to be associated with dominant infantile cataracts. To understand the structural basis for γS-Y67N to cause lens opacification, we constructed, expressed and purified γS-Y67N and its wild-type (abbreviated hereafter as γS-WT) and studied the structural and functional differences between them in solution using circular dichroism (CD), differential scanning calorimetry (DSC), fluorescence spectroscopy and extrinsic spectral probes. Extensive equilibrium characterization indicate that replacement of the highly conserved Tyr at 67th position by Asn distorts the conserved Tyr corner at the second Greek key motif in the N-terminal domain (NTD) and leads to substantial loss of structural stability. Our intrinsic fluorescence quenching results reveal differential in-vitro refolding kinetics identifying partially folded kinetic intermediates for both proteins. Extrinsic fluorescence studies further reveal loosening up of the compact structure of γS-crystallin upon mutation associated with enhanced aggregation. As Ca{sup 2+} homeostasis is a crucial regulator of lens transparency, we further investigated the Ca{sup 2+}-binding properties of γS-WT and γS-Y67N by isothermal titration calorimetry (ITC) to identify lens Ca{sup 2+} distribution in health and in disease. Overall, our results highlight the vital role of conserved Tyr corners in stabilizing Greek key motifs and provide useful structural and functional insights into the mechanism of cataract formation in humans.

60 APPLIED LIFE SCIENCES↗

Linear Accelerator-Based Intensity-Modulated Total Marrow Irradiation Technique for Treatment of Hematologic Malignancies: A Dosimetric Feasibility Study

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Response Effect of Charged Carbon Beam on Normal Rat Retina Assessed by Electroretinography

Purpose: To compare the effects of carbon beam irradiation with those of proton beam irradiation on the physiology of the retina of rats. Methods and Materials: Eight-week-old Wister rats were used. The right eyes were irradiated with carbon beam (1, 2, 4, 8, and 16 Gy) or proton beam (4, 8, 16, and 24 Gy) with the rats under general anesthesia. Electroretinograms were recorded 1, 3, 6, and 12 months after the irradiation, and the amplitudes of the a and b waves were compared with those of control rats. Results: The amplitude of b waves was reduced more than that of a waves at lower irradiation doses with both types of irradiation. With carbon ion irradiation, the amplitudes of the b wave were significantly reduced after radiation doses of 8 and 16 Gy at 6 months and by radiation doses of 4, 8, and 16 Gy at 12 months. With proton beam irradiation, the b-wave amplitudes were significantly reduced after 16 and 24 Gy at 6 months and with doses of 8 Gy or greater at 12 months. For the maximum b-wave amplitude, a significant difference was observed in rats irradiated with carbon beams of 4 Gy or more and with proton beams of 8 Gy or more at 12 months after irradiation. Conclusions: These results indicate that carbon beam irradiation is about two times more damaging than proton beam irradiation on the rat retina at the same dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Efficacy of Radiation Therapy in the Treatment of Graves' Orbitopathy

Purpose: To review our institutional outcomes of patients treated with radiation therapy (RT) for Graves' orbitopathy (GO), assess the role of orbital reirradiation, and identify prognostic factors of complete response (CR). Methods and Materials: This is a retrospective review of 211 patients who presented with a diagnosis of GO and received RT between January 2000-2010. RT dose was 20 Gy in 10 fractions. Patient median age was 51 years (range, 15-84 years), median follow-up was 11 months (range, 1-88 months). Patient symptoms included any combination of proptosis (90.9%), extraocular muscle dysfunction (78.9%), soft tissue signs (68.4%), and diplopia (58.4%). Corticosteroids were used as first-line therapy in 20.6% of patients. Among those who achieved either CR or partial response (PR), prognostic factors were evaluated. Results: Stabilization of disease without recurrence was clinically achieved overall in 202 patients (96.7%). At the completion of RT, 176 patients (84.2%) reported a symptomatic improvement of pretreatment symptoms. CR of GO symptoms was achieved using multiple treatment modalities, including RT by 93 patients (44.5%), of which 32 patients received RT only. Corticosteroids were discontinued in 97.8% of patients who received them as initial therapy. Surgical intervention following radiotherapy was required for 144 (68.9%) of all patients. Fourteen patients received orbital reirradiation for persistent or recurrent symptoms. Five of these achieved a CR, and the other nine achieved disease stabilization but retained persistent ocular symptoms. Long-term side effects of RT included dry eyes (12%). Of the prognostic factors we investigated, only gender predicted CR, which was less common in men (33.9%) than in women (49.7%) p = 0.0471. Conclusions: Orbital radiation for GO is an established treatment modality for patients. Orbital reirradiation is beneficial for patients who do not respond to initial RT or experience symptom recurrence without an apparent risk of increased morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low or High Fractionation Dose {beta}-Radiotherapy for Pterygium? A Randomized Clinical Trial

Purpose: Postoperative adjuvant treatment using {beta}-radiotherapy (RT) is a proven technique for reducing the recurrence of pterygium. A randomized trial was conducted to determine whether a low fractionation dose of 2 Gy within 10 fractions would provide local control similar to that after a high fractionation dose of 5 Gy within 7 fractions for surgically resected pterygium. Methods: A randomized trial was conducted in 200 patients (216 pterygia) between February 2006 and July 2007. Only patients with fresh pterygium resected using a bare sclera method and given RT within 3 days were included. Postoperative RT was delivered using a strontium-90 eye applicator. The pterygia were randomly treated using either 5 Gy within 7 fractions (Group 1) or 2 Gy within 10 fractions (Group 2). The local control rate was calculated from the date of surgery. Results: Of the 216 pterygia included, 112 were allocated to Group 1 and 104 to Group 2. The 3-year local control rate for Groups 1 and 2 was 93.8% and 92.3%, respectively (p = .616). A statistically significant difference for cosmetic effect (p = .034), photophobia (p = .02), irritation (p = .001), and scleromalacia (p = .017) was noted in favor of Group 2. Conclusions: No better local control rate for postoperative pterygium was obtained using high-dose fractionation vs. low-dose fractionation. However, a low-dose fractionation schedule produced better cosmetic effects and resulted in fewer symptoms than high-dose fractionation. Moreover, pterygia can be safely treated in terms of local recurrence using RT schedules with a biologic effective dose of 24-52.5 Gy{sub 10.}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗