Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Depth-resolved Laue microdiffraction with coded apertures

A rapid data acquisition and reconstruction method is introduced to image the crystalline structure of materials and the associated strain and orientations at micrometre resolution using Laue diffraction. The method relies on scanning a coded aperture across the diffracted X-ray beam from broadband illumination and a reconstruction algorithm to resolve Laue microdiffraction patterns as a function of depth along the incident illumination path. It provides rapid access to full diffraction information for sub-micrometre volume elements in bulk materials. Both the theory and the experimental validation of this imaging approach are presented in this report.

36 MATERIALS SCIENCE↗

Revisiting the structures and phase transitions of Ba 2 NaNb 5 O 15

The room-temperature and low-temperature structure(s) of Ba 2 NaNb 5 O 15 (BNN) have been debated since the structure was proposed in the 1960s. This work revisits the structures and phase transitions of BNN, combining high-resolution X-ray and neutron powder diffraction with density functional theory calculations. Temperature-dependent high-resolution X-ray powder diffraction patterns are collected from 4 to 918 K, and sequential batch Rietveld refinement using a symmetry mode approach to describe the structure is used to extract the main structural changes as a function of temperature. The data show that the average structure of BNN is best described by the Ama2 space group, and no other structural phase transitions were observed below the ferroelastic transition. The symmetry mode analysis, combining results from diffraction and density functional theory, shows significant octahedral tilting and corrugations of both the A1 and A2 sites along the c direction. A strong correlation between the spontaneous strain and the octahedral tilting was observed, and a potential connection with emerging microstructure at low temperatures is proposed, all enabled by the symmetry mode approach used in this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Texture measurements on quartz single crystals to validate coordinate systems for neutron time-of-flight texture analysis

In crystallographic texture analysis, ensuring that sample directions are preserved from experiment to the resulting orientation distribution is crucial to obtain physical meaning from diffraction data. This work details a procedure to ensure instrument and sample coordinates are consistent when analyzing diffraction data with a Rietveld refinement using the texture analysis software MAUD . A quartz crystal is measured on the HIPPO diffractometer at Los Alamos National Laboratory for this purpose. The methods described here can be applied to any diffraction instrument measuring orientation distributions in polycrystalline materials.

36 MATERIALS SCIENCE↗

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Flexible positioning of a large area detector using an industrial robot

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.

36 MATERIALS SCIENCE↗

Investigation of fast and efficient lossless compression algorithms for macromolecular crystallography experiments

Structural biology experiments benefit significantly from state-of-the-art synchrotron data collection. One can acquire macromolecular crystallography (MX) diffraction data on large-area photon-counting pixel-array detectors at framing rates exceeding 1000 frames per second, using 200 Gbps network connectivity, or higher when available. In extreme cases this represents a raw data throughput of about 25 GB s −1 , which is nearly impossible to deliver at reasonable cost without compression. Our field has used lossless compression for decades to make such data collection manageable. Many MX beamlines are now fitted with DECTRIS Eiger detectors, all of which are delivered with optimized compression algorithms by default, and they perform well with current framing rates and typical diffraction data. However, better lossless compression algorithms have been developed and are now available to the research community. Here one of the latest and most promising lossless compression algorithms is investigated on a variety of diffraction data like those routinely acquired at state-of-the-art MX beamlines.

36 MATERIALS SCIENCE↗

Laser, vacuum and gas reaction chamber for operando measurements at NSLS-II's 28-ID-2

We present a laser reaction chamber that we have developed for in situ/operando X-ray diffraction measurements at the NSLS-II 28-ID-2 X-ray powder diffraction beamline. This chamber allows for rapid and dynamic sample heating under specialized gas environments, spanning ambient conditions down to vacuum pressures. We demonstrate the capabilities of this setup through two applications: laser-driven heating in polycrystalline iron oxide and in single-crystal WTe 2 . Our measurements reveal the ability to resolve chemical reaction kinetics over minutes with 1 s time resolution. This setup advances opportunities for in situ/operando X-ray diffraction studies of both bulk and single-crystal materials.

36 MATERIALS SCIENCE↗

BraggNN : fast X-ray Bragg peak analysis using deep learning

X-ray diffraction based microscopy techniques such as high-energy diffraction microscopy (HEDM) rely on knowledge of the position of diffraction peaks with high precision. These positions are typically computed by fitting the observed intensities in detector data to a theoretical peak shape such as pseudo-Voigt. As experiments become more complex and detector technologies evolve, the computational cost of such peak-shape fitting becomes the biggest hurdle to the rapid analysis required for real-time feedback in experiments. To this end, we propose BraggNN, a deep-learning based method that can determine peak positions much more rapidly than conventional pseudo-Voigt peak fitting. When applied to a test dataset, peak center-of-mass positions obtained from BraggNN deviate less than 0.29 and 0.57 pixels for 75 and 95% of the peaks, respectively, from positions obtained using conventional pseudo-Voigt fitting (Euclidean distance). When applied to a real experimental dataset and using grain positions from near-field HEDM reconstruction as ground-truth, grain positions using BraggNN result in 15% smaller errors compared with those calculated using pseudo-Voigt. Recent advances in deep-learning method implementations and special-purpose model inference accelerators allow BraggNN to deliver enormous performance improvements relative to the conventional method, running, for example, more than 200 times faster on a consumer-class GPU card with out-of-the-box software.

36 MATERIALS SCIENCE↗

Multi-crystal native-SAD phasing at 5 keV with a helium environment

De novo structure determination from single-wavelength anomalous diffraction using native sulfur or phospho­rus in biomolecules (native-SAD) is an appealing method to mitigate the labor-intensive production of heavy-atom derivatives and seleno­methio­nyl substitutions. The native-SAD method is particularly attractive for membrane proteins, which are difficult to produce and often recalcitrant to grow into decent-sized crystals. Native-SAD uses lower-energy X-rays to enhance anomalous signals from sulfur or phospho­rus. However, at lower energies, the scattering and absorption of air contribute to the background noise, reduce the signals and are thus adverse to native-SAD phasing. We have previously demonstrated native-SAD phasing at an energy of 5 keV in air at the NSLS-II FMX beamline. Here, the use of a helium path developed to reduce both the noise from background scattering and the air absorption of the diffracted X-ray beam are described. The helium path was used for collection of anomalous diffraction data at 5 keV for two proteins: thaumatin and the membrane protein TehA. Although anomalous signals from each individual crystal are very weak, robust anomalous signals are obtained from data assembled from micrometre-sized crystals. The thaumatin structure was determined from 15 microcrystals and the TehA structure from 18 microcrystals. These results demonstrate the usefulness of a helium environment in support of native-SAD phasing at 5 keV.

59 BASIC BIOLOGICAL SCIENCES↗

Thick filament activation is different in fast- and slow-twitch skeletal muscle

The contractile properties of fast-twitch and slow-twitch skeletal muscles are primarily determined by the myosin isoform content and modulated by a variety of sarcomere proteins. X-ray diffraction studies of regulatory mechanisms in muscle contraction have focused predominately on fast- or mixed-fibre muscle with slow muscle being much less studied. Here, we used time-resolved X-ray diffraction to investigate the dynamic behaviour of the myofilament proteins in relatively pure slow-twitch-fibre rat soleus (SOL) and pure fast-twitch-fibre rat extensor digitorum longus (EDL) muscle during twitch and tetanic contractions at optimal length. During twitch contractions the diffraction signatures indicating a transition in the myosin heads from ordered OFF states, where heads are held close to the thick filament backbone, to disordered ON states, where heads are free to bind to thin filaments, were found in EDL and not in SOL muscle. During tetanic contraction, changes in the disposition of myosin heads as active tension develops is a quasi-stepwise process in EDL muscle whereas in SOL muscle this relationship appears to be linear. The observed reduced extensibility of the thick filaments in SOL muscle as compared to EDL muscles indicates a molecular basis for this behaviour. These data indicate that for the EDL, thick filament activation is a cooperative strain-induced mechano-sensing mechanism, whereas for the SOL, thick filament activation has a more graded response. Further, these different approaches to thick filament regulation in fast- and slow-twitch muscles may be adaptations for short-duration, strong contractions versus sustained, finely controlled contractions, respectively.

59 BASIC BIOLOGICAL SCIENCES↗

Dispersion Leverage Coronagraph: a nulling coronagraph for use on primary objective grating telescopes

Here, we present the Dispersion Leverage Coronagraph (DLC), a variation of the Achromatic Interfero Coronagraph (AIC) that is designed for optical systems featuring large, dispersive primary objective gratings. DLC was originally designed for the Diffractive Interfero Coronagraph Exoplanet Resolver (DICER), a notional 20 m class infrared space telescope utilizing the enhanced one-dimensional angular resolution of large diffraction gratings to discover and characterize near-Earth exoplanets. Here we develop the theoretical foundation for DLC, and apply it to DICER as an example use case. We derive important properties of the DLC system, including focal plane transmission maps, stellar leakage, residual optical path difference tolerance, and pointing error/jitter considerations. Ultimately, we found that DLC effectively nulls an on-axis target across the entire spectrum in the focal plane, allowing for 2D/λ diffraction-limited imaging. It requires asymmetrical fine-guidance tolerances on pointing error/jitter. We work through a benchmark DICER design, explaining the need for a second disperser to reduce background from Zodiacal light, and showing that it could plausibly find and characterize ∼4 nearby, habitable exoplanets around Sun-like stars in a 7-year mission; about 30% of the habitable exoplanets within 8 pc were found in our simulation. The DLC may be useful for any application requiring extremely high-resolution, close companion spectroscopy.

AIC↗

Examples of X-Ray Characterization Techniques in Energy Storage Research

Lithium-ion batteries have revolutionized the portable electronics and transportation sectors. Their performance is often critically dependent on the crystal structures of the anode and cathode electrode materials, which must enable the transport and reversible storage of lithium ions into and out of the lattice. Because lithium is a low-Z element, characterization of materials for lithium-ion batteries can be particularly challenging. Regardless, X-ray techniques enable analysis of material structures to better understand how battery materials perform and degrade, particularly when combined with other materials characterization and electrochemical characterization techniques. While X-ray techniques are most often used in battery research for phase identification of crystal structures, X-ray characterization techniques are also used for a wide variety of other purposes. I will discuss several examples from my research with various collaborators on several projects that highlight the impact that X-ray characterization techniques can have on battery research. The first example will focus on low-temperature microwave-assisted solvothermal synthesis of vanadium-doped LiFePO4 cathode materials for lithium-ion batteries. (1,2) Through a combination of electrochemical and materials characterization, we determined that low temperature synthesis resulted in metastable phases that enabled incorporation of higher dopant levels than resulting from high-temperature synthesis of thermodynamically stable phases. Rietveld refinement of X-ray diffraction data enabled understanding of how lattice parameters changed with doping levels and synthesis temperature. X-ray absorption near edge spectroscopy enabled understanding of the vanadium and iron oxidation states to confirm how vacancies in the structure caused by doping were charge compensated. This was important to understand because the literature suggests doping can improve LiFePO4 electrical conductivity, which improves battery charge and discharge rates. The second example will focus on understanding residual strain in lithium metal anodes. Lithium-ion batteries typically use graphite anodes, but the charge-storage capacity can be theoretically improved ~10x by using lithium metal as the anode material instead. However, lithium anodes suffer from growth of high-aspect-ratio features, such as dendrites, that can pierce nanoporous polymer separators and lead to short circuits and fires. External pressure is commonly applied to cells to enable better morphological control. We hypothesized that applied pressure may promote strain and possibly work hardening during electrochemical cycling, which motivated us to look for evidence of residual strain in lithium metal cycled under applied pressure using X-ray diffraction and sin2(..psi..) analysis. We found that lithium electrodeposited under high pressure exhibited in-plane compressive strain and that that lithium electrodeposited under low pressure did not. (3) The residual strain that accompanies electrodeposition under high pressure may lead to work hardening, which may explain how a soft metal like lithium can puncture separators and why higher pressure does not always decrease short circuits. (4-6) References: 1) Harrison, K. L.; Manthiram, A. Microwave-Assisted Solvothermal Synthesis and Characterization of Metastable LiFe1- x (VO) x PO4 Cathodes. Inorganic chemistry 2011, 50(8), 3613-3620. 2) Harrison, K. L.; Bridges, C. A.; Paranthaman, M. P.; Segre, C. U.; Katsoudas, J.; Maroni, V. A.; Idrobo, J. C.; Goodenough, J. B.; Manthiram, A. Temperature Dependence of Aliovalent-Vanadium Doping in LiFePO4 Cathodes. Chemistry of Materials 2013, 25(5), 768-781. 3) Rodriguez, M. A.; Harrison, K. L.; Goriparti, S.; Griego, J. J.; Boyce, B. L.; Perdue, B. R. Use of a Be-Dome Holder for Texture and Strain Characterization of Li Metal Thin Films via Sin2 (..psi..) Methodology. Powder Diffraction 2020, 35(2), 89-97. 4) Jungjohann, K. L.; Gannon, R. N.; Goriparti, S.; Randolph, S. J.; Merrill, L. C.; Johnson, D. C.; Zavadil, K. R.; Harris, S. J.; Harrison, K. L. Cryogenic Laser Ablation Reveals Short-Circuit Mechanism in Lithium Metal Batteries. ACS Energy Letters 2021, 6(6), 2138-2144. 5) Harrison, K. L.; Merrill, L. C.; Long, D. M.; Randolph, S. J.; Goriparti, S.; Christian, J.; Warren, B.; Roberts, S. A.; Harris, S. J.; Perry, D. L. Cryogenic Electron Microscopy Reveals That Applied Pressure Promotes Short Circuits in Li Batteries. Iscience 2021, 24(12). 6) Harrison, K. L.; Goriparti, S.; Merrill, L. C.; Long, D. M.; Warren, B.; Roberts, S. A.; Perdue, B. R.; Casias, Z.; Cuillier, P.; Boyce, B. L. Effects of Applied Interfacial Pressure on Li-Metal Cycling Performance and Morphology in 4 M LiFSI in DME. ACS Applied Materials & Interfaces 2021, 13(27), 31668-31679.

batteries↗

Comparison of Orientation Mapping in SEM and TEM

In this work, multiple experimental configurations for performing nanoscale orientation mapping are compared to determine their fidelity to the true 3D microstructure of a sample. Transmission Kikuchi Diffraction (TKD) experiments in an SEM and nanobeam diffraction (NBD) experiments in a TEM were performed on thin electrodeposited hard Au films with two different microstructures. The Au samples either have a grain size that is >50 nm or <20 nm. The same regions of the samples were measured with TKD apparatuses at 30 kV in an SEM with detectors in the horizontal and vertical configurations and in the TEM at 300 kV. Under the proper conditions, we demonstrate all three configurations can produce data of equivalent quality.Each method has strengths and challenges associated with its application and representation of the true microstructure. The conditions needed to obtain high-quality data for each acquisition method and the challenges associated with each will be discussed.

36 MATERIALS SCIENCE↗

Supramolecular Metal‐Organic Framework Electrocatalysts With Hydration‐Adaptive Gallery Expansion and Linker‐Mediated Distal Ni‐Co Cooperation Enable Framework‐Retentive Oxygen Evolution

Atomic‑level tailoring of electronic communication between spatially separated metal sites offers a route to accelerate multielectron electrocatalysis. We report Ni-TPTC, Co-TPTC, and heterobimetallic Ni-Co-TPTC supramolecular metal-organic frameworks (SMOFs) for the oxygen evolution reaction (OER) built from a terphenyl‑tetracarboxylate (TPTC) linker. Single-crystal X-ray diffraction of heterobimetallic Ni–Co–TPTC reveals trans-bis-aqua octahedral chains assembled into a π-stacked, hydrogen-bonded lattice and confirms retention of the parent architecture, while powder X-ray diffraction supports an isostructural Co analog. In 1.0 M KOH, Ni-Co-TPTC reaches 20 mA cm −2 at 350 mV and maintains operation at ∼60 mA cm −2 for 45 h with modest decay of the initial current. Time‑dependent ex situ diffraction shows dominant framework reflections with low‑angle shifts consistent with gallery dilation (d‑spacing ∼7.7 → ∼9.2 Å) during early operation, while Co K‑edge X‑ray absorption and microscopy reveal Co‑rich oxide/oxyhydroxide‑like domains at longer times that correlate with decay. X‑ray photoelectron spectroscopy, quantified by the Remote Binding‑Energy Differential, tracks composition‑dependent Ni-Co polarization, and DFT free‑energy analysis suggests that a model Ni-Co environment lowers the Co‑centered potential‑limiting step by ∼0.24 eV relative to the Co‑only framework. Furthermore, these results suggest that framework‑retentive expansion and distal Ni-Co coupling can drive OER activity before gradual deligation and oxide formation mark longer‑time degradation.

Supramolecular metal-organic frameworks (SMOFs)↗

Double Paddle‐Wheel Enhanced Sodium Ion Conduction in an Antiperovskite Solid Electrolyte

Abstract Antiperovskite structure compounds (X 3 AB, where X is an alkali cation and A and B are anions) have the potential for highly correlated motion between the cation and a cluster anion on the A or B site. This so‐called “paddle‐wheel” mechanism may be the basis for enhanced cation mobility in solid electrolytes. Through combined experiments and modeling, the first instance of a double paddle‐wheel mechanism, leading to fast sodium ion conduction in the antiperovskite Na 3− x O 1− x (NH 2 ) x (BH 4 ), is shown. As the concentration of amide (NH 2 − ) cluster anions is increased, large positive deviations in ionic conductivity above that predicted from a vacancy diffusion model are observed. Using electrochemical impedance spectroscopy, powder X‐ray diffraction, synchrotron X‐ray diffraction, neutron diffraction, ab initio molecular dynamics simulations, and NMR, the cluster anion rotational dynamics are characterized and it is found that cation mobility is influenced by the rotation of both NH 2 − and BH 4 − species, resulting in sodium ion conductivity a factor of 10 2 higher at x = 1 than expected for the vacancy mechanism alone. Generalization of this phenomenon to other compounds could accelerate fast ion conductor exploration and design.

25 ENERGY STORAGE↗

Heterotrimetallic Mixed‐Valent Molecular Precursors Containing Periodic Table Neighbors: Assignment of Metal Positions and Oxidation States

Abstract A known trinuclear structure was used to design the heterobimetallic mixed‐valent, mixed‐ligand molecule [Co II (hfac) 3 −Na−Co III (acac) 3 ] ( 1 ). This was used as a template structure to develop heterotrimetallic molecules [Co II (hfac) 3 −Na−Fe III (acac) 3 ] ( 2 ) and [Ni II (hfac) 3 −Na−Co III (acac) 3 ] ( 3 ) via isovalent site‐specific substitution at either of the cobalt positions. Diffraction methods, synchrotron resonant diffraction, and multiple‐wavelength anomalous diffraction were applied beyond simple structural investigation to provide an unambiguous assignment of the positions and oxidation states for the periodic table neighbors in the heterometallic assemblies. Molecules of 2 and 3 are true heterotrimetallic rather than a statistical mixture of two heterobimetallic counterparts. Trinuclear platform 1 exhibits flexibility in accommodating a variety of di‐ and trivalent metals, which can be further utilized in the design of molecular precursors for the NaMM′O 4 functional oxide materials.

Han, Haixiang↗

Clathrate XI K 58 Zn 122 Sb 207 : A New Branch on the Clathrate Family Tree

Abstract The compositional screening of K‐Zn‐Sb ternary system aided by machine learning, rapid exploratory synthesis using KH salt‐like precursor and in situ powder X‐ray diffraction yielded a novel clathrate type XI K 58 Zn 122 Sb 207 . This clathrate consists of a 3D Zn‐Sb framework hosting K + ions inside polyhedral cages, some of which are reminiscent of known clathrate types while others are unique to this structure type. The complex non‐centrosymmetric structure in the tetragonal space group was solved by means of single crystal X‐ray diffraction as a 6‐component twin due to pseudocubic symmetry and further confirmed by high‐resolution synchrotron powder X‐ray diffraction and state‐of‐the‐art scanning transmission electron microscopy. The electron‐precise composition of this clathrate yields narrow‐gap p ‐type semiconductor with extraordinarily low thermal conductivity due to displacement or “rattling” of K cations inside oversized cages and as well as to twinning, stacking faults and antiphase boundary defects.

Cox, Tori↗