Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

DOUBLE COMPACT OBJECTS. III. GRAVITATIONAL-WAVE DETECTION RATES

The unprecedented range of second-generation gravitational-wave (GW) observatories calls for refining the predictions of potential sources and detection rates. The coalescence of double compact objects (DCOs)—i.e., neutron star–neutron star (NS–NS), black hole–neutron star (BH–NS), and black hole–black hole (BH–BH) binary systems—is the most promising source of GWs for these detectors. We compute detection rates of coalescing DCOs in second-generation GW detectors using the latest models for their cosmological evolution, and implementing inspiral-merger-ringdown gravitational waveform models in our signal-to-noise ratio calculations. We find that (1) the inclusion of the merger/ringdown portion of the signal does not significantly affect rates for NS–NS and BH–NS systems, but it boosts rates by a factor of ∼1.5 for BH–BH systems; (2) in almost all of our models BH–BH systems yield by far the largest rates, followed by NS–NS and BH–NS systems, respectively; and (3) a majority of the detectable BH–BH systems were formed in the early universe in low-metallicity environments. We make predictions for the distributions of detected binaries and discuss what the first GW detections will teach us about the astrophysics underlying binary formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

High-field quench behavior and dependence of hot spot temperature on quench detection voltage threshold in a Bi 2 Sr 2 CaCu 2 O x coil

Here, small insert coils have been built using a multifilamentary Bi 2 Sr 2 CaCu 2 O x round wire, and characterized in background fields to explore the quench behaviors and limits of Bi 2 Sr 2 CaCu 2 O x superconducting magnets, with an emphasis on assessing the impact of slow normal zone propagation on quench detection. Using heaters of various lengths to initiate a small normal zone, a coil was quenched safely more than 70 times without degradation, with the maximum coil temperature reaching 280 K. Coils withstood a resistive voltage of tens of mV for seconds without quenching, showing the high stability of these coils and suggesting that the quench detection voltage shall be greater than 50 mV to not to falsely trigger protection. The hot spot temperature for the resistive voltage of the normal zone to reach 100 mV increases from ~40 K to ~80 K with increasing the operating wire current density J o from 89 A/mm -2 to 354 A/mm -2 whereas for the voltage to reach 1 V, it increases from ~60 K to ~140 K, showing the increasing negative impact of slow normal zone propagation on quench detection with increasing J o and the need to limit the quench detection voltage to < 1 V. These measurements, coupled with an analytical quench model, were used to access the impact of the maximum allowable voltage and temperature upon quench detection on the quench protection, assuming to limit the hot spot temperature to <300 K.

43 PARTICLE ACCELERATORS↗

AE AURIGAE: FIRST DETECTION OF NON-THERMAL X-RAY EMISSION FROM A BOW SHOCK PRODUCED BY A RUNAWAY STAR

Runaway stars produce shocks when passing through interstellar medium at supersonic velocities. Bow shocks have been detected in the mid-infrared for several high-mass runaway stars and in radio waves for one star. Theoretical models predict the production of high-energy photons by non-thermal radiative processes in a number sufficiently large to be detected in X-rays. To date, no stellar bow shock has been detected at such energies. We present the first detection of X-ray emission from a bow shock produced by a runaway star. The star is AE Aur, which was likely expelled from its birthplace due to the encounter of two massive binary systems and now is passing through the dense nebula IC 405. The X-ray emission from the bow shock is detected at 30'' northeast of the star, coinciding with an enhancement in the density of the nebula. From the analysis of the observed X-ray spectrum of the source and our theoretical emission model, we confirm that the X-ray emission is produced mainly by inverse Compton upscattering of infrared photons from dust in the shock front.

79 ASTRONOMY AND ASTROPHYSICS↗

DETECTABILITY OF GLYCINE IN SOLAR-TYPE SYSTEM PRECURSORS

Glycine (NH{sub 2}CH{sub 2}COOH) is the simplest amino acid relevant to life. Its detection in the interstellar medium is key to understanding the formation mechanisms of pre-biotic molecules and their subsequent delivery onto planetary systems. Glycine has been extensively searched for toward hot molecular cores, although these studies did not yield any firm detection. In contrast to hot cores, low-mass star forming regions, in particular their earliest stages represented by cold pre-stellar cores, may be better suited for the detection of glycine as well as more relevant to the study of pre-biotic chemistry in young solar system analogs. We present one-dimensional spherically symmetric radiative transfer calculations of the glycine emission expected to arise from the low-mass pre-stellar core L1544. Water vapor has recently been reported toward this core, indicating that a small fraction of the grain mantles in L1544 (∼0.5%) has been injected into the gas phase. Assuming that glycine is photo-desorbed together with water in L1544, and considering a solid abundance of glycine on ices of ∼10{sup –4} with respect to water, our calculations reveal that several glycine lines between 67 GHz and 80 GHz have peak intensities larger than 10 mK. These results show for the first time that glycine could reach detectable levels in cold objects such as L1544. This opens up the possibility of detecting glycine, and other pre-biotic species, at the coldest and earliest stages in the formation of solar-type systems with near-future instrumentation such as the Band 2 receivers of ALMA.

79 ASTRONOMY AND ASTROPHYSICS↗

Source-agnostic gravitational-wave detection with recurrent autoencoders

Abstract We present an application of anomaly detection techniques based on deep recurrent autoencoders (AEs) to the problem of detecting gravitational wave (GW) signals in laser interferometers. Trained on noise data, this class of algorithms could detect signals using an unsupervised strategy, i.e. without targeting a specific kind of source. We develop a custom architecture to analyze the data from two interferometers. We compare the obtained performance to that obtained with other AE architectures and with a convolutional classifier. The unsupervised nature of the proposed strategy comes with a cost in terms of accuracy, when compared to more traditional supervised techniques. On the other hand, there is a qualitative gain in generalizing the experimental sensitivity beyond the ensemble of pre-computed signal templates. The recurrent AE outperforms other AEs based on different architectures. The class of recurrent AEs presented in this paper could complement the search strategy employed for GW detection and extend the discovery reach of the ongoing detection campaigns.

47 OTHER INSTRUMENTATION↗

When different entanglement witnesses detect the same entangled states

The question of under what conditions different witnesses (e.g., W{sub 1},W{sub 2}) may detect some common entangled states [i.e., there exists some state {rho} so that Tr(W{sub 1{rho}})<0 and Tr(W{sub 2{rho}})<0] is answered for both finite-dimensional and infinite-dimensional bipartite systems. Finitely many different witnesses W{sub 1},W{sub 2},...,W{sub n} can detect some common entangled states if and only if {Sigma}{sub i=1}{sup n}d{sub i}W{sub i} is still a witness for any nonnegative numbers d{sub 1},d{sub 2},...,d{sub n} with {Sigma}{sub i=1}{sup n}d{sub i}=1; they cannot detect any common entangled state if and only if {Sigma}{sub i=1}{sup n}c{sub i}W{sub i} is a positive operator for some nonnegative numbers c{sub 1},c{sub 2},...,c{sub n} with {Sigma}{sub i=1}{sup n}c{sub i}=1. For two witnesses W{sub 1} and W{sub 2} more can be said. First, W{sub 1} and W{sub 2} can detect the same set of entangled states if and only if W{sub 1}=aW{sub 2} for some number a>0. Second, W{sub 2} can detect more entangled states than W{sub 1} can if and only if W{sub 1}=aW{sub 2}+D for some number a>0 and a positive operator D. As an application, some characterizations of the optimal witnesses are given and some structural properties of the decomposable optimal witnesses are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light dark matter detection prospects at neutrino experiments

We consider the prospects for the detection of relatively light dark matter through direct annihilation to neutrinos. We specifically focus on the detection possibilities of water Cherenkov and liquid scintillator neutrino detection devices. We find, in particular, that liquid scintillator detectors may potentially provide excellent detection prospects for dark matter in the 4-10 GeV mass range. These experiments can provide excellent corroborative checks of the DAMA/LIBRA annual modulation signal, but may yield results for low mass dark matter in any case. We identify important tests of the ratio of electron to muon neutrino events (and neutrino versus antineutrino events), which discriminate against background atmospheric neutrinos. In addition, the fraction of events which arise from muon neutrinos or antineutrinos (R{sub {mu}} and R{sub {mu}}) can potentially yield information about the branching fractions of hypothetical dark matter annihilations into different neutrino flavors. These results apply to neutrinos from secondary and tertiary decays as well, but will suffer from decreased detectability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep Learning-Based Data Forgery Detection in Automatic Generation Control

Automatic Generation Control (AGC) is a key control system in the power grid. It is used to calculate the Area Control Error (ACE) based on frequency and tie-line power flow between balancing areas, and then adjust power generation to maintain the power system frequency in an acceptable range. However, attackers might inject malicious frequency or tie-line power flow measurements to mislead AGC to do false generation correction which will harm the power grid operation. Such attacks are hard to be detected since they do not violate physical power system models. In this work, we propose algorithms based on Neural Network and Fourier Transform to detect data forgery attacks in AGC. Different from the few previous work that rely on accurate load prediction to detect data forgery, our solution only uses the ACE data already available in existing AGC systems. In particular, our solution learns the normal patterns of ACE time series and detects abnormal patterns caused by artificial attacks. Evaluations on the real ACE dataset show that our methods have high detection accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concept Study of Robotic Camera-Based Foreign Object Detection for EV Wireless Charging

Wireless charging of an electric vehicle (EV) is an emerging charging technology promising convenient, autonomous, and highly efficient EV charging without requiring heavy gauge cables. However, due to the strong electromagnetic field created by this process that surrounds the wireless charger, the presence of foreign objects can detrimentally interact with it, thus affecting wireless power transfer (WPT) performance or leading to harmful and unwanted safety risks. This paper presents the results for a concept study on a robotic camera-based foreign object detection (FOD) system, as a supplement to the industry-existing overlapped FOD coil array method, for EV wireless charging. A Raspberry PI 4 control board and compatible Raspberry PI Camera Module 2 are used to implement camera-based object detection. The FOD program was developed using a state-of-the-art deep learning object detection model with the OpenCV and Pytorch library and is compatible with camera module hardware. A dry-run test with Raspberry PI and a camera module was conducted and the preliminary FOD function was verified. The feasibility assessment is also validated by comparing the performance of five existing state-of-the-art deep learning object detection models for vehicles, animals, persons, and metals subsets, respectively. Satisfactory performance on the benchmark datasets is observed by the tests, but further improvements are needed in future work when detecting small-sized metallic objects. A programable robotic car is also under development as ongoing work for carrying the Raspberry PI and camera module while moving for the maintenance process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unobtrusive Sensor-Based Occupancy Facing Direction Detection and Tracking Using Advanced Machine Learning Algorithms

Facing direction detection plays a critical role in human-computer interaction and has a wide application in surveillance systems, driving awareness recognition, smart home appliances, computer games, and so on. Current detection methods are mainly focused on extracting specific patterns from user's optical images, which raises concerns on privacy invasion and these detection techniques do not usually work in a dark environment. To address these concerns, here this paper proposes an activity recognition system guided by an unobtrusive sensor (ARGUS). By using a low pixel infrared thermopile array sensor, ARGUS is capable of identifying five facing directions (left 45°/90°, right 45°/90°, and front) through the support vector machine classifier. Also two feature extraction methods are compared. One is manually-defined and the other is based on a pre-trained convolutional neural network (CNN) model. The facing direction detection accuracy resulting from manually-defined features reaches 85.3%, 90.6%, and 85.2% at detection distance of 0.6, 1.2, and 1.8 m, respectively. The level of accuracy resulted from using pre-trained CNN features demonstrates a much more reliable performance (89.1%, 95.3%, and 95.1% at distance of 0.6, 1.2, and 1.8 m, respectively). In addition, ARGUS has been successfully applied for occupancy tracking with a root mean square error of 0.19 m.

42 ENGINEERING↗

Autonomous Sensor System for Wind Turbine Blade Collision Detection

This paper presents an automated blade collision detection system for use on wind turbines, toward the goal of supporting monitoring and quantitative assessment of wind energy impacts on wildlife. A wireless, multisensor module mounted at the blade root measures surface vibrations, and a blade-mounted camera provides image capture of colliding objects. Using sensor data recorded during field testing of the system on an operational wind turbine, we present the development, training, and testing of automated detection algorithms for collision detection using machine-learning approaches. In particular, we compare the use of a new two-step, anomaly-based classification algorithm with conventional adaptive boosting and amplitude-based detection techniques, where the two-step approach improves average precision for the experimental data set. This integrated sensor and classification systems demonstrates a new approach for automated, on-blade collision detection for wind turbines, with broad utility across structural health monitoring applications.

17 WIND ENERGY↗

Security Evaluation of Two Intrusion Detection Systems in Smart Grid SCADA Environment

The increased complexity and interconnectivity of SCADA infrastructure in the power system have exposed it to the multitude of vulnerabilities. There is a growing emphasis towards developing an efficient intrusion detection system (IDS) to strengthen the security of the SCADA control system. This is a research-in-progress paper which presents the application of two anomaly-based intrusion detection systems (AIDS) in detecting the stealthy cyber-attack on the SCADA control system. We have applied the IDS tools Snort and Bro, in designing the IDS and later, compared their performances in terms of detection rate and latency in the alert packets with a motive of selecting better IDS for the SCADA security. Specifically, the timing-based rule is applied to identify the malicious packets based on the high temporal frequency in the network traffic. For the case study, we have implemented the SCADA based protection scheme which performs an autonomous protection to mitigate the system disturbances. We first implemented the stealthy cyber-attack which compromised the SCADA controller followed by data integrity attack on the system generator. Next, we perform the impact analysis during the attack followed by performance evaluation of IDS tools. Our experimental results show that the IDS tools are efficient in detecting cyber-attacks within an acceptable time frame for different sizes of network packets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Shift Detection in Sensor-Based PV Power and Irradiance Time Series: Preprint

PV power and irradiance sensor-based measurements are prone to error, resulting in issues such as abrupt time series data shifts. These shifts, which are usually unintentional, may be caused by software or hardware configuration changes on a PV system, and do not reflect an actual change in overall system performance. Locating these shifts and segmenting the associated time series aids in more accurate future PV analysis. In this research, an offline changepoint detection (CPD) algorithm that automatically detects these abrupt data shifts in sensor-based time series is introduced. Data shift periods in 101 daily PV power and irradiance time series were labeled manually by two solar experts. These data streams represent sensor-based measurements, and display a variety of data shift behaviors. A changepoint detection algorithm was tuned using the 101 labeled data streams, with each model configuration's ability to detect labeled changepoints benchmarked using metrics such as F1-score, recall, and Rand Index. Best performing models on seasonality-corrected data streams include the Pruned Exact Linear (PELT) method, the Binary Segmentation method, and the Bottom-Up method, all scoring an average F1-score of 0.76 or greater at detecting labeled changepoints within a 30-day window for the labeled data sets. To promote further research in this space, we are releasing the labeled data shift sets on U.S. Department of Energy's (DOE) DuraMAT Data Hub, and the associated algorithm in the Python PVAnalytics package.

changepoint detection↗

A Sparse and Low Rank Penalized Signal Decomposition Model with Constraints: Anomaly Detection in PV Systems

Recently, robust PCA has seen its wide application in various industries for its ability to perform the task of anomaly detection. The essence of robust PCA approach is to break down the signal into a low rank component and sparse component. In many applications, a simple breakdown of the signal without accounting for the signs of low rank components and sparse components would violate the physical constraints of the decomposed signal. In addition, often times, the signals in the real world collected for a long duration has smooth changes within a day and between days. As an example, the power signals collected in a photovoltaic (PV) system are cyclostationary, exhibiting these characteristics. Neglecting the smoothness of signals would result in miss detection of anomalous signals which are smooth within a day but non-smooth between days and vice versa. In this paper, we developed a signal decomposition approach for the purpose of anomaly detection based on the idea of low rank and sparse decomposition taking into consideration the signs of the decomposed low rank and sparse components and the within-day and between-day smooth changes in the original signals. The proposed unsupervised approach for fault detection eliminates the need for faulty samples required by other machine learning methods. It does not require the full I-V characteristics to work. Furthermore, there is no need for complex modelling of PV systems as in the case of power loss analysis. Using Monte Carlo simulations, we demonstrate the ability of our proposed approach for detecting anomalies of different duration and severity in PV systems.

14 SOLAR ENERGY↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Detection on Seismic Structural Images Using a Nested Residual U-Net

Automatic identification of faults on seismic structural images is a challenging yet crucial task in quantitative seismic interpretation. Human picking or attribute-based fault detection methods may misidentify faults on noisy, complex seismic images. In this work, we develop a new automatic fault detection method using a nested residual U-shaped convolutional neural network. Each of the encoders and decoders in this neural network is a residual U-Net, leading to a nested architecture. The final fault map results from the fusion of three fault maps with low, medium, and high fault resolutions. We demonstrate the excellent fault-detection capability of our nested neural network using a series of synthetic and field seismic images. We find that our approach produces clearer and more interpretable fault maps than the current state-of-the-art U-Net fault detection method, particularly on noisy seismic images. Our new automatic fault detection method can facilitate reliable quantitative seismic interpretation on field seismic images.

58 GEOSCIENCES↗

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗