Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Slippery Omniphobic Covalently Attached Liquids for Extreme Anti-Scaling

Fouling is amajor unresolved problem in a varietyof industries including power generation, water desalination,and hydrometallurgy. In a heat exchanger, the accumulated salt scale could lead to a decrease in heat transfer, corrosion, blockage of flow and increasedpressure drop, resulting in higher operation costsand shortened equipment lifetime. The added operational costs due to active scale removal techniques such as mechanical abrasion and chemical inhibitors are responsible for 0.25% of the GDP in industrialized nations.Herewe utilize slippery omniphobic covalently attached liquids (SOCAL) dip coating on aluminum substrates to minimize surface energyand surface roughness, hence maximizingthe energy barrier for scale formation. To enable SOCAL surfacebinding on aluminum, we started by depositinga nanoscale(500 nm thick)adhesion layer of SiO2using scalable and cost-effective electrophoretic deposition (EPD), followed by SOCAL grafting to the SiO2.The EPD SiO2coating chemistry was tailored to achieve a smoothsurface finish which, combined with the low surface energyof the SOCAL coating, translated to extreme anti-scaling performance. Thermal degradation testing in an ambient environment revealed the covalently bonded SOCAL coatingswithstand temperatures of 100°C. To characterize scaling, we utilized CaSO4and CaCO3scale tests, showing up to 20X less scaling than uncoated aluminum. Descaling tests revealed that our SOCAL coatings dramatically decrease scale adhesion, resulting in rapid removal of scale buildup in highly supersaturated conditions. To investigate manufacturability, two alternate methods of SiO2deposition were tested, including physical vapor deposition and spin-on glass, with great success in coating smooth metallic substrates, but limited success due to the inability to coat arbitrarily shaped surfaces. Our work not only demonstrates a facile method of tailoring interfacial energy and roughness to control fouling, it develops cost-effective, scalable,and high performing anti-fouling coating applicable to aluminum surfacesfor a variety of applications.

Zhao, Hanyang↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodologies for Evaluation of Corrosion Protection for Ductile Iron Pipe

Repairing the nation’s infrastructure and ensuring its future durability are key issues facing the United States. It is important that these critical issues are addressed with appropriate and economical solutions based on the best modern scientific information. For example, in 2013 the American Society of Civil Engineers (ASCE), in its Report Card for America’s Infrastructure, gave the state of the critical water/wastewater infrastructure an overall grade of “D.” According to the ASCE, 6 billion gallons of drinking water disappear every day, mostly due to leaks in old pipes. Corrosion of water pipes plays a role in their durability and, for external pipe corrosion, the corrosivity of soils varies by location and is based on several factors, including soil resistivity. There is universal agreement that water pipes require some type of corrosion mitigation strategy (i.e., bare pipe is not installed). However, in specifying which strategy to employ for ductile iron pipe (DIP) in different soil types, the recommendations of the US Bureau of Reclamation (USBR) Technical Memorandum 8140-CC-2004-1 were subject to considerable debate. So much so that in 2009, this report was the subject of a study by the National Academy, which did not resolve the debate about the most effective and affordable solutions. Zinc-coatings have been explored in other parts of the world. Despite being widely used in Europe for almost 60 years, zinc coating was barely mentioned in either the 2004 or 2009 studies, which appeared to focus on North American data.

36 MATERIALS SCIENCE↗

Comparative Analysis of Transport and Storage Options from a CO 2 Source Perspective

This analysis evaluated integrated CCS costs (i.e., capture, transport, and storage) from the perspective of a CO 2 source. Capture costs for sources with annual CO 2 capture rates from 0.65 to 3.90 Mt were based on two NETL reports. Transportation costs from source to storage reservoir were modeled for two pipelines systems (dedicated and trunkline) using the FE/NETL CO 2 Transport Cost Model. Storage costs were modeled in dome and regional dip structural settings for two reservoirs in the Rose Run Formation, three within the Mt. Simon, one in the Lower Tuscaloosa, and one in the Frio using the FE/NETL CO 2 Saline Storage Cost Model. A paper with the same name and information as well as additional details on this analysis was published in The International Journal of Greenhouse Gas Control along with a supplementary document that provides additional material (i.e., key parameters used in the models for obtaining transport and storage costs and CCS cost and pipeline results).

03 NATURAL GAS↗

Solvent Hold Tank Sample Results for MCU-18-425- 427 (October 2018), MCU-18-459-460-461 (November 2018), and MCU-18-487-488-489 (December 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples MCU-18-425-426-427, MCU-18- 459-460-461 and MCU-18-487-488-489 are reported. Most of the conclusions are based on the December SHT sample (MCU-18-487-488-489). Analyses of the December SHT sample (MCU-18-487-488-489 indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 2% and 9% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the October 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing (from May through November 2018) to 528 mg/L, but it is above the minimum recommended concentration (479 mg/L). These new levels are consistent with the concentrations observed when MCU was fully operational in 2016. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the October sample and consistently detected in the November and December samples (but always a few ppm or less). Another impurity observed in the samples was mercury. Based on the December SHT sample, up to 24 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~3.6E5 dpm/mL) measured in the December SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) but it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to an Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CarbonSAFE Rocky Mountain Phase I: Ensuring Safe Subsurface Storage of Carbon Dioxide in the Intermountain West

An integrated CCS pre-feasibility study, CarbonSAF E Rocky Mountain Phase I, was conducted by the U niversity of Utah and its partners as part of the US D epartment of Energy’s Carbon Storage Assurance a nd Facility Enterprise (CarbonSAFE) program. The a ssembled project team consisted of academic, indus try and governmental agencies covering the technic al and non- technical challenges of a commercial-sc ale CO 2 storage facility capable of storing 50 million tonnes of anthropogenically-sourced CO 2 . The Rock y Mountain CarbonSAFE team identified the Hunter Power Plant in central Utah as the primary source of CO 2 on which this study would be focused. The nea rby Huntington power plant, also operated by Rocky Mountain Power, was evaluated as a secondary sou rce of CO 2 . The Hunter plant was chosen because o f an interest in CO 2 capture technology by the plant operator, Rocky Mountain Power, and also because i t is a representative example of a typical coal-fired g enerating station in the Rocky Mountain west. Amine -based and cryogenic-based capture assessments w ere performed for approximately 3 million tonnes per year for one of the boiler units at the Hunter plant, yi elding cost of capture estimates of $\$56$/tonne and $\$4 1.50$/tonne. Transportation and intermediate compre ssion would increase the per tonne costs, but will be highly dependent on specific injection locations and available rights-of-way. A high-level technical sub-ba sinal evaluation was performed on the area surround ing the Hunter and Huntington power plants to verify CO 2 storage capacity and integrity. Initial geologic c haracterization efforts focused on sites immediately adjacent to the Hunter plant, including the deep eolia n Permian White Rim Sandstone, which in outcrop a nd core from other locations indicates high permeabi lity and high porosity. However, petrophysical logs fr om wells near Hunter indicate porosity of only 2-4%. As a result, potential injection sites were moved stru cturally down-dip (to the west), into the high permea bility (~200 mD) and high porosity (20%) Navajo san dstone. A comprehensive analysis of the reservoir a nd seals was conducted, providing data to the model , simulation and risk assessment groups on the proje ct. CO 2 capacity estimates for the Navajo Sandston e approximately 18 kilometers from the Hunter plant are well in excess of the 50 million tonnes goal of the project. Area of Review Delineation and Risk Asse ssment on the Navajo, associated seals and shallow groundwater aquifers identified the most significant risks and mitigation options. A non-technical assessment to a commercial-scale CO 2 storage facility in central Utah was conducted. EPA Underground Injection Control Class VI and National Environmental Policy Act permitting present particularly challenging issues related to the development of any saline aquifer for CO 2 storage, including the area around the Hunter plant. While surface and subsurface ownership and ri ghts are not straightforward, especially on any privat e land, many of the stakeholders in central Utah are accustomed and open to oil/gas/mineral-related activities similar to what would be required for CO 2 storage sites.

01 COAL, LIGNITE, AND PEAT↗

Carbon Composite Microelectromechanical Systems (CMEMS)

Pyrolyzed carbon as a mechanical material is promising for applications in harsh environments. In this work, we characterized the material and developed novel processes for fabricating carbon composite micro-electromechanical systems (CMEMS) structures. A novel method of increasing Young's modulus and the conductivity of pyrolyzed AZ 4330 was demonstrated by loading the films with graphene oxide prior to pyrolysis. By incorporating 2 wt.% graphene stiffeners into the film, a 65% increase in Young's modulus and 11% increase in conductivity were achieved. By reactive ion etching pyrolyzed blanket AZ 50XT thick film photoresist, a high aspect ratio process was demonstrated with films >7.5um thick. Two novel multi-level, volume-scalable CMEMS processes were developed on 6" diameter wafers. Young's modulus of 23 GPa was extracted from nanoindentation measurements of pyrolyzed AZ 50XT films. The temperature-dependent resistance was characterized from room temperature to 500C and found to be nearly linear over this range. By fitting the results of self-heated bridges in an inert ambient, we calculated that the bridges survived to 1000C without failure. Transmission electron microscopy (TEM) results showed the film to be largely amorphous, containing some sub-micrometer sized graphite crystallites. This was consistent with our Raman analysis, which also showed the film to be largely sp 2 bonded. The calculated average density of pyrolyzed AZ 4330 films was 1.32 g/cm 2 . Thin level of disorder and the conductivity of thin film resistors were found to unchanged by 2Mrad gamma irradiation from a Co 60 source. Thin film pyrolyzed carbon resistors were hermetically sealed in a nitrogen ambient in 24-pin dual in-line packages (DIP's). The resistance was measured periodically and remained constant over 6 months' time.

36 MATERIALS SCIENCE↗

Summary of Expedited Results from Samples Supporting Tank Closure Cesium Removal (TCCR) Batch 3

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal (TCCR) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 3 for processing through the TCCR unit. SRNL received and characterized a set of dip samples collected from Tank 10H (one surface and one variable depth sample). No solids were observed in either sample and therefore the samples were combined, and a suite of analyses were performed on the composite sample. The density of the combined sample was 1.174 g/mL (0.18 %RSD), which was consistent with the measured sodium concentration of 3.54 M (0.08 %RSD). The 137Cs activity in the sample was 4.75E+07 dpm/mL (4.28 %RSD) and the total Cs concentration was calculated to be 1.54 mg/L (1.16E-05 M). The in-tank batch contact samples consist of 0.1 g of crystalline silicotitanate (CST) contained within a teabag device. Duplicate samples were submerged in Tank 10H supernate for a period of about 13 days, after which time they were retrieved and transferred to SRNL for analysis. At SRNL the CST was rinsed to remove excess salt solution and the CST was then air dried before being digested for analysis. Results of the analysis indicated a 137 Cs loading of 3.66E+10 ± 1.40E+09 dpm/g or 16.5 ± 0.63 Ci/kg CST . This value represents a bounding upper limit as it includes the addition of two sigma uncertainty from replicate analysis of the individual teabag samples as well as the addition of the small amount of 137 Cs activity measured in the rinse solutions. The above values are based on the air-dried mass of CST. Correcting to the true dry mass using a F-factor of 0.8191 results in a maximum loading of 20.2 ± 0.77 Ci/kg CST .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sedimentary Geothermal Resources in Nevada, Utah, Colorado, and Texas

The objectives of this project were to (1) perform a literature review of sedimentary geothermal resources, (2) identify data sources and develop data-collection methodologies that characterize selected resources, (3) screen sedimentary basins and formations for sedimentary geothermal potential, and (4) evaluate the technical feasibility of one or more selected locations. Numerous publications have characterized geothermal resources within sedimentary basins. A literature search reviewed publications describing resources located in Colorado, Louisiana, Nevada, Texas, Utah, and Wyoming. The most attractive resources have high temperature gradients, low drilling costs, and reservoir permeabilities greater than 10 millidarcies (mD). Prospects in Colorado, Nevada, Texas, and Utah exhibit attractive characteristics and were chosen for further analysis. Sedimentary resources in Nevada and Utah are most attractive, followed by tested resources in Texas and untested resources in Colorado. The identified resources in Wyoming and Louisiana had lower geothermal gradients and were not evaluated. Reservoir modeling and techno-economic analysis were performed at Marys River Basin–North in Nevada. Geothermal energy production at this location is expected to have a levelized cost of energy (LCOE) ranging between 10 and 20 cents/kWh. Additional work may result in lower LCOE estimates at this location and at other attractive prospects in these three regions. The Great Basin carbonate and alluvial aquifer system of eastern Nevada and western Utah includes a lower carbonate aquifer unit, which has the potential for hosting both conduction- and convection-dominated geothermal systems. Mapping has identified lateral thickness variability expressed as a roughly 120–150-km-wide central corridor, which hosts the thickest and most continuous formations and extends from near Las Vegas north to the Idaho border. Purchase and analysis of privately held legacy seismic data could potentially compensate for the lack of sufficient data documenting measured depth to the lower carbonate aquifer unit. Multiple orogenies, extension episodes, and intrusive events have deformed and displaced the target formations of the lower carbonate aquifer unit. This structural complexity and potential for dipping reservoirs emphasizes the need for detailed geological, geophysical, and reservoir modeling. Heat flow within three Colorado sedimentary basins reviewed as part of this study was calculated in targeted studies by the Colorado Geologic Survey and Colorado School of Mines. These calculations are based on bottom-hole temperature data sets with significant limitations and some variability but produce values consistently higher than the global continental average of 65 mW/m2 for all three basins. Heat flow in the Raton Basin is the highest; however, permeability measurements from specific sedimentary formations with high heat flow have not been obtained. Promising formations for sedimentary geothermal systems were found in all three regions studied—Nevada-Utah, Colorado, and Texas. The next steps for developing sedimentary geothermal resources vary due to differences in available data and resource uncertainties. Additional scopes of work are recommended for identified basins in these three regions.

15 GEOTHERMAL ENERGY↗

Seismic Wave Coherence as a Function of Propagation Azimuth at the Large-N Array, Source Physics Experiment

The Large-N array of the Source Physics Experiment (SPE) consisted, in part, of 496 vertical component geophones that recorded the seismic wave field produced by the SPE-5 buried chemical explosion. Preliminary observations of the data showed a large degree of azimuthally dependent seismic scattering, particularly for post-P wave arrivals, hindering surface wave analysis. We document and quantify the azimuthal dependence of the wave field scattering in order to guide future coherent wave field processing methods. Specifically, we form three linear arrays, with different nominal source-receiver azimuths, by extracting a subset of the Large-N stations. For each linear array, we evaluate wave field coherence as a function of frequency and inter-station distance. For P waves, we observe that there is a strong azimuthal dependence of wave coherence, with the highest degree of scattering occurring in a northwest/southeast propagation direction. This suggests that there are structural elements beneath the Large-N array that affect the direct source to receiver body wave ray path. We also observe that the scattering of the post-P energy displays a coherence that is dependent on both frequency and azimuthal direction. This energy is preferentially coherent in the southwest-to-northeast propagation direction, consistent with the strike of the steeply dipping fault (Boundary fault) adjacent to the northeast side of the Large-N array, but only at low frequencies (<10 Hz). At higher frequencies, the azimuthally dependent wave coherence diminishes, suggesting that the scattering of high frequency portion of the post-P wave field is independent of the large-scale geologic structure at this site.

58 GEOSCIENCES↗

Self-Disinfecting Polymeric Coatings

A novel derivative of a previously-published polymeric material has been synthesized and developed into an easily-sprayable coating. Surface characterization of coatings confirm correct elemental presence, and viral assays reveal quantitative elimination of MS2 bacteriophage and Phi6 bacteriophage, surrogates used for SARS-CoV-2, in as little as 5 minutes upon contact. Furthermore, an N95 mask was dip-coated in the polymer solution and analyzed through microscopy and filtration efficacy testing. Though coating was successful, electrostatic interactions between mask layers and polymer reduced filtration efficacy significantly. As such, we expect the current results of this work to be applicable on non-respiratory PPE and on solid substrates of commonly-touched surfaces for rapid self-decontamination.

59 BASIC BIOLOGICAL SCIENCES↗

Reduction of CO 2 Emissions Through Lightweight Body Panels (Project Final Report)

Lightweight construction is an integral part of Volkswagen’s overall strategy of reducing CO 2 emissions. Due to its low cost, steel is the most commonly used material for automotive exterior body panels today. Unfortunately, steel has a high density, resulting in a relatively low specific strength. Glass fiber based sheet molding compounds (SMC) provide high properties in combination with lower density. The high specific strength of SMC offers an enormous lightweight potential. To unlock the full potential of SMC materials in combination with cutting edge manufacturing processes, Volkswagen Group of America worked together with IACMI (Institute for Advanced Composites Manufacturing Innovation) and the academic partners: University of Tennessee Knoxville, Purdue University and Michigan State University; as well as the industry partners: Ashland, IDI, Owens Corning and Continental Structural Plastics. Leveraging the expertise of all project partners, reaching over the entire supply chain the project demonstrated the potential of these materials. This report will highlight the major steps in the development process on the way to technology readiness for SMC using the example of the Volkswagen Atlas Liftgate. Over the 36-month period of the project, the work focused on three R&D areas: material development, design and simulation, and development of the manufacturing process. Material selection included alternative fibers and resin systems, and accounted for material availability, properties, and cost-efficiency. The work undertaken in the field of design and simulation has pushed the envelope of short fiber reinforced thermoset molding compound process simulation. Design iterations were virtually tested, while the final design was used to validate the simulation software against physical parts. Manufacturing development used cutting-edge technology, while experts along the supply chain were working together to ensure the best possible results. In the final stage of the project, liftgates were molded, trimmed, bonded, painted and assembled before exhaustive testing. The result is an e-coat (electrophoretic dip coating) capable Class-A SMC liftgate, which is ready for high-volume production, and can be used as a technology demonstrator. The prototypes manufactured in the scope of this work have exhibited a mass reduction for the Volkswagen Atlas liftgate of up to 35% compared to the series production steel version, without a degradation of the functionalities.

36 MATERIALS SCIENCE↗

Entangled-photon interferometry for plasmas

Sub-picosecond coincidence timing from nonlocal intensity interference of entangled photons allows quantum interferometry for plasmas. Using a warm plasma dispersion relation, we correlate phase measurement sensitivity with different plasma properties or physics mechanisms over 6 orders of magnitude. Due to N α (α ≤ - 1/2) scaling with the photon number N, quantum interferometry using entangled light can probe small signals in plasmas not previously accessible. As an example, it is predicted that plasmas will induce shifts to a Gaussian dip, a well-known quantum optics phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CO 2 Storage Capacity In Tertiary-Age Gulf Coast Coals

The Gulf Coast region contains a large, under-explored, Tertiary-age coal belt. These coals, deposited within the greater Wilcox Group cover an area stretching from southern Texas along the Gulf’s Margin, as far north as Arkansas and Tennessee, and as far east as the Florida panhandle. The Gulf Coast Tertiary Coals are deposited over an aerially extensive margin along the Northern Gulf Coast and achieve significant vertical thicknesses. Lower Wilcox coals may be present in as many as 5 to 10 seams, providing a net thickness of 15 to 25 feet when the individual seams are grouped together over a gross interval of hundreds of feet. These coals dip towards the Gulf of Mexico coastline and are found at depths of 1,000 feet to depths greater than 7,000 feet. The CO 2 storage capacity of these coals is determined using adsorption isotherms from samples throughout the region. The Tertiary coal belt is divided into three sub-plays based on geologic and political boundaries. Each sub-play has unique coal properties used in the storage calculations. These properties include area, depth, thickness, and porosity and are used with the adsorption isotherms to estimate the overall CO 2 storage capacity. The total CO 2 storage capacity estimate of these coals ranges from 20 to 28 billion metric tons (380 to 540 trillion cubic feet).

01 COAL, LIGNITE, AND PEAT↗

Permit Injectors and New Observation Wells at Early Test Site (SECARB Phase III (Early) Project at Cranfield)

At Cranfield field well permitting was part of a routine operation that Denbury conducted on behalf of the University of Texas and the SECARB Project. Denbury permits injection and production wills through the Mississippi Oil and Gas Board (MO&GB). The MO&GB permitted the two observation wells as production wells, although they are not in the oil-productive part of the field (being deliberately located down-dip of the oil-water contact). The well permits issues April 15, 2009 for the observation wells are attached in appendix A. Denbury also permitted 8 injection wells to support the High Volume Injection Test (HiVIT); four of these are drilled unusually far downdip to support the sequestration experiment. These permits are held by Denbury as part of their normal operations.

54 ENVIRONMENTAL SCIENCES↗

Alabama Department of Environmental Management Temporary Abandonment Report [Well Names/ID: D4-13]

Two temporarily abandoned Citronelle Oil Field wells (D 4-13 and D 4-14) located up-dip from the D 9- 7#2 injection well (approximately 3,500 feet away) and outside of the area of review (Figure 1) were designated to be used for the monitoring activities associated with the SECARB Anthropogenic Test. Both wells were recompleted prior to the project, which included perforating the D 4-14 within the injection zone and the D 4-13 above the proposed confining unit. The D-4-13 well provides above-zone pressure monitoring in a perforated interval from 9,186 feet to 9,188 feet, with the gauge landing nipple at 9,111 feet. In-zone pressure monitoring occurs in the D-4- 14, perforated from 9,420 feet to 9,422 feet. The gauge landing nipple was set at 9,375 ft. Following the completion of the project These wells were converted back to their original condition for oilfield operations.

01 COAL, LIGNITE, AND PEAT↗

SECARB Post Injection Assessment Report

The Southern States Energy Board (SSEB) managed the overall Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III project and The Bureau of Economic Geology (BEG), at the University of Texas at Austin, managed all activities associated with the Early Test field site near Cranfield, Mississippi (the Early Test or Cranfield Project). The SECARB project at Cranfield was focused downdip of the oil rim and on demonstrating the stacked nature of the storage potential at this location: enhanced oil recovery (EOR) up-dip and saline downdip. Because the injection for EOR continued after the SECARB project ended, no actual post-injection period occurred. However, information collected during the SECARB-monitored injection period, including pressure and CO2 plume position, was utilized in an EOR carbon lifecycle assessment. The carbon lifecycle assessment provided insight on tracking injection fronts and production efficiencies across the field. To complete the post injection assessment, taking into account the continuing EOR period after closeout of SECARB field activities, this report provides data and analysis done under another DOE-funded project. The follow up project focused on the carbon lifecycle of EOR and included an assessment of EOR at as-operated and under possible future scenarios. This work was published by Hossieni et al. (2018) and Hosseininoosheri (2019).

01 COAL, LIGNITE, AND PEAT↗

Parametric Study to Assess Technical Prospect Feasibility for Offshore CO 2 Storage

This report is a white paper on the parametric study to assess technical prospect feasibility for CO 2 storage with and without CO 2 -EOR. The SECARB Offshore GOM team reviewed key parameters that previous modeling experience suggests have the largest impact on CO 2 plume size and CO 2 -EOR performance (SSEB, 2019) These parameters include tectonic impacts (reservoir dip and fault block size), reservoir properties (permeability) and development strategies (well field payout, waterflood, and CO 2 flooding strategies). These parameters are further evaluated in this study in order to identify upper and lower boundary conditions for the parametric values. The boundary conditions are needed to set constraints for key parameters when performing modeling assessments. Understanding the key parametric values for the GOM will facilitate locating successful offshore carbon capture utilization and storage (CCUS) projects in terms of plume size, CO 2 stored and, in the case of EOR, oil recovery. Importantly, this white paper focuses on both technical factors (geologic and engineering), but does not address economic, commercial, or stakeholder considerations. The report is organized into four sections and includes a review of the datasets used to define the parameter ranges, the results of a full-physics reservoir simulation, a summary of a reduced order modeling approach to evaluate the impact of the study parameters, and, finally, a discussion of the work that will occur during the next phase of the project.

02 PETROLEUM↗