Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA CORRELATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Correlation of windage-loss data for a Lundell alternator

Viscous torque (windage) of a Lundell-shaped rotor having a major diameter of 20.3 cm (8 in.) rotating within a concentric housing was measured at speeds up to 36,000 rpm. The center cylindrical section of the housing was tested with both a smooth surface and axial slots to simulate alternator winding slots. For concentric cylinders, the range of Reynolds numbers was extended to 70,000. Three radial clearances, 1, 2, and 4 mm (0.04, 0.08, and 0.16in.), corresponding to 1, 2, and 4 percent of the rotor radius, were tested.

Kempke, E. E., Jr.↗

Engine investigation of an air-cooled turbine rotor blade incorporating impingement-cooled leading edge, chordwise passages, and a slotted trailing edge

Experimental temperatures are presented for an air-cooled turbine rotor blade tested in an engine. The data were obtained for turbine stator inlet temperatures from 2000 to 2500 F and for turbine-inlet gas pressures from 32 to 46 psia. Average and local blade heat-transfer data are correlated. Potential allowable increases in gas temperature are also discussed.

Dengler, R. P.↗

Systematic two-dimensional cascade tests. Volume 3: Slotted double circular-arc hydrofoils

Performance parameters are presented for cascades of slotted double circular-arc hydrofoils tested over a range of systematically introduced variables in a rectilinear cascade tunnel which uses water as the test medium. Cascade configurations included various combinations of an inlet flow angle of 50, 60 and 70 deg; a cascade solidity of 0.75, 1.00 and 1.50; a hydrofoil camber angle of 20, 30, 40 and 45 deg; and angles of incidence between positive and negative stall. The slot was positioned at the 45 percent chord station and the slot exit width was 0.047-in. Tests were also performed with the slot positioned at the 35 percent chord station and with slot widths of 0.63 and 0.094-in. These data were correlated to indicate the effects of slot location and slot width on minimum loss incidence and deviation angles. In addition, a comparison is presented of the performance parameters for cascades of slotted and unslotted hydrofoils.

Columbo, R. M.↗

Task 1: Correlation of satellite and ground data in air pollution studies. Task 2: Investigation to relate the chlorophyll and suspended sediment content in the waters of the lower Chesapeake Bay to ERTS-1 imagery. Task 3: The use of ERTS-1 to more fully utilize and apply marine station data to the study of productivity along the Eastern Shelf expanded waters of the United States

The author has identified the following significant results. Analysis of U-2 imagery of CARETS site indicates smoke plumes can be easily detected. First look at selected ERTS-1 color composites demonstrates plumes from forest fires can be detected.

Copeland, G. E.↗

Application of ERTS-A data to the protection and management of New Jersey's coastal environment

The author has identified the following significant results. Apparent sewage sludge disposal by barge has been detected approximately 12 miles offshore in an area with an approximate radius of 2.5 nautical miles. Verification is underway to determine whether this dumping is within one of the approved dump sites in the Bight. Analysis of all available historical and routine meteorological data in correlation with the observed phenomenon is necessary before final conclusions can be reached with respect to the effects of currents on the disposal of dumped wastes. Four effluent plumes emanating from the shoreline just south of Sandy Hook were observed and are moving in a southerly direction. Another plume is evident north of Barnegat Inlet and is moving almost directly offshore. This suggests that the more northerly plumes are under the influence of the tidal regime around New York Harbor much more than are the plumes further south along the New Jersey coast. Of further interest are what appear to be an internal wave phenomena approximately 75 miles east of the New Jersey coast. This same sort of phenomena has been observed repetitively off the coast of Oregon.

Yunghans, R. S.↗

Analyses of flight model spacecraft performance during thermal-vacuum tests

Malfunction data from the thermal-vacuum tests of 39 flight-model spacecraft were analyzed. The results are interpreted in terms of the test variables, and in terms of the spacecraft performance. The malfunction data are correlated with the test time as a single variable, and also with the composite variable of time plus temperature. The improvement in spacecraft performance is examined by means of malfunction rates, malfunctions per spacecraft, and the probability of no failure related to test time. The minimum thermal-vacuum test profile required for Goddard Space Flight Center spacecraft is verified, and the probability of a defect remaining undetected is estimated.

Timmins, A. R.↗

Effect of pressure on tangential-injection film cooling in a combustor exhaust stream

A tangential-injection film cooled test section was placed in the exhaust stream of a high pressure combustor. Film cooling data were taken at pressure of 1, 10, and 20 atmospheres. The film cooling effectiveness was found to be independent of pressure. The data were correlated adequately by a turbulent-mixing film cooling correlation with a turbulent-mixing coefficient of 0.05 + or - 0.02.

Marek, C. J.↗

Fan and pump noise control

The development is described of improved, low noise level fan and pump concepts for the space shuttle. In addition, a set of noise design criteria for small fans and pumps was derived. The concepts and criteria were created by obtaining Apollo hardware test data to correlate and modify existing noise estimating procedures. A set of space shuttle selection criteria was used to determine preliminary fan and pump concepts. These concepts were tested and modified to obtain noise sources and characteristics which yield the design criteria and quiet, efficient space shuttle fan and pump concepts.

Misoda, J.↗

Correlation of new hypervelocity impact data by threshold penetration relations

Threshold penetration data are established by impacting spherical projectiles onto 2024 aluminum single-wall targets. Nylon and cadmium projectiles were used at impacting velocities from 3.0 to 6.8 km/s and 7.9 to 8.5 km/s respectively. These data are combined with existing data and compared with three threshold relations to assess their respective validities over a wide range of projectile densities. Two of these relations were validated over the extended range of projectile densities.

Hayduk, R. J.↗

Study of Thermodynamic Vent and Screen Baffle Integration for Orbital Storage and Transfer of Liquid Hydrogen

A comprehensive analytical and experimental program was performed to determine the feasibility of integrating an internal thermodynamic vent system and a full wall-screen liner for the orbital storage and transfer of liquid hydrogen (LH2). Ten screens were selected from a comprehensive screen survey. The experimental study determined the screen bubble point, flow-through pressure loss, and pressure loss along rectangular channels lined with screen on one side, for the 10 screens using LH2 saturated at 34.5 N/cm2 (50 psia). The correlated experimental data were used in an analysis to determine the optimum system characteristics in terms of minimum weight for 6 tanks ranging from 141.6 m3 (5,000 ft3) to 1.416 m3 (50 ft3) for orbital storage times of 30 and 300 days.

Cady, E. C.↗

Analyses of flight model spacecraft performance during thermal-vacuum tests

Malfunction data from the thermal-vacuum tests of 39 flight-model spacecraft have been analyzed. The results are interpreted in terms of the test variables and the spacecraft performance. The malfunction data are correlated with the test time as a single variable, and also with the composite variable of time plus temperature. The improvement in spacecraft performance is examined by means of malfunction rates, malfunctions per spacecraft, and the probability of no failure related to test time. The minimum thermal-vacuum test profile required for Goddard Space Flight Center spacecraft is verified, and the probability of a defect remaining undetected is estimated.

Timmins, A. R.↗

Vibration behavior of fuel-element vibration suppressors for the advanced power reactor

Preliminary shock and vibration tests were performed on vibration suppressors for the advanced power reactor for space application. These suppressors position the fuel pellets in a pin type fuel element. The test determined the effect of varying axial clearance on the behavior of the suppressors when subjected to shock and vibratory loading. The full-size suppressor was tested in a mockup model of fuel and clad which required scaling of test conditions. The test data were correlated with theoretical predictions for suppressor failure. Good agreement was obtained. The maximum difference with damping neglected was about 30 percent. Neglecting damping would result in a conservative design.

Adams, D. W.↗

Forced-convection peak heat flux on cylindrical heaters in water and refrigerant 113

An investigation was conducted of the peak heat flux on cylindrical heaters in a fluid flowing perpendicular to the major axis of the heater. The test fluids were water and Refrigerant 113. Heaters of 0.049 to 0.181 cm diameter were tested over a fluid velocity range of 10.1 to 81.1 cm/sec. The experimental results were observed to fall within two regions based on the vapor removal geometry: jets or sheets. Mathematical models for each region successfully correlated the data for both fluids.

Cochran, T. H.↗

Crack-growth behavior in thick welded plates of Inconel 718 at room and cryogenic temperatures

Results of mechanical-properties and axial-load fatigue and fracture tests performed on thick welded plates of Inconel 718 superalloy are presented. The test objectives were to determine the tensile strength properties and the crack-growth behavior in electron-beam, plasma-arc, and gas tungsten are welds for plates 1.90 cm (0.75 in) thick. Base-metal specimens were also tested to determine the flaw-growth behavior. The tests were performed in room-temperature-air and liquid nitrogen environments. The experimental crack-growth-rate data are correlated with theoretical crack-growth-rate predictions for semielliptical surface flaws.

Forman, R. G.↗