A measurement of B0 meson properties using partially reconstructed B0 to D*- pi+ and B0 tp D*- lepton+ nu-leptonm decays with the BABAR detector
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
The Thermal and Catalytic Process Development Unit at NREL has state-of-the-art equipment for thermochemical process development and testing, ranging from catalyst and feedstock characterizations to bench-scale reactors to pilot plants. Within this facility is the 2 Inch Fluidized Bed Reactor, a versatile lab-scale thermal processing and catalytic upgrading system to evaluate the conversion of renewable and waste feedstocks into fuels and chemicals. In addition, the NREL Research Gasifier is a lab-scale gasification system, perfectly suited to study the conversion of biomass and waste streams to purified syngas. This fact sheet summarizes the capabilities of both systems.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
There are a lot of metallic large components for the transport of radioactive waste in Germany. Some of these large components like for example the Castor S1 with 82 Mg are so old, that the transport via streets is not possible because the permission is not valid anymore. The application for a new permission is economically not reasonable. Out of this reason the large components need to be decontaminated and recycled to use them again in the economic cycle. Decontamination of large components by cleaning/removing the surface for example with beam technology is a very time-consuming release procedure. Manufacturing a specialized machine for decontamination and creation of a new surface was the intention of this project. The objective was to save interim storage and final repository volume and costs as well as developing a process that is nationally and internationally usable. 90% of the volume/mass of waste could be released and therefore possibly re-used. (authors)
As part of the Plateau Remediation Project at US Department of Energy's Hanford, Washington site, CH2M Hill Plateau Remediation Company (CHPRC) contracted with IMPACT Services, LLC to receive and deactivate approximately 28 cubic meters of sodium metal contaminated debris from two sodium-cooled research reactors (Enrico Fermi Unit 1 and the Fast Flux Test Facility) which had been stored at Hanford for over 25 years. CHPRC found an off-site team composed of IMPACT Services and Commodore Advanced Sciences, Inc., with the facilities and technological capabilities to safely and effectively perform deactivation of this sodium metal contaminated debris. IMPACT Services provided the licensed fixed facility and the logistical support required to receive, store, and manage the waste materials before treatment, and the characterization, manifesting, and return shipping of the cleaned material after treatment. They also provided a recycle outlet for the liquid sodium hydroxide byproduct resulting from removal of the sodium from reactor parts. Commodore Advanced Sciences, Inc. mobilized their patented AMANDA unit to the IMPACT Services site and operated the unit to perform the sodium removal process. Approximately 816 Kg of metallic sodium were removed and converted to sodium hydroxide, and the project was accomplished in 107 days, from receipt of the first shipment at the IMPACT Services facility to the last outgoing shipment of deactivated scrap metal. There were no safety incidents of any kind during the performance of this project. The AMANDA process has been demonstrated in this project to be both safe and effective for deactivation of sodium and NaK. It has also been used in other venues to treat other highly reactive alkali metals, such as lithium (Li), potassium (K), NaK and Cesium (Cs). (authors)
The Nuclear and Applied Robotics Group (NRG) has developed two mobile systems with simple, intuitive Human-Machine Interfaces (HMIs). Thus, the systems can be operated by operators who are not robotics experts to perform inventory, inspection and routine contamination surveys in areas where Special Nuclear Material (SNM) is stored and handled. This effort presents feedback collected from EM operators using the two systems at the Portsmouth Gaseous Diffusion Plant in Piketon, OH who used the robotic solutions to perform tasks on site and with minimal training. This approach has the potential to address issues related to ALARA, ergonomics, and reliably completing dull, repetitive tasks while maintaining domain-specific experts in the control loop. The two systems were shipped to - and demonstrated in - a DOE designated area and demonstrated completing contamination testing using a combination of real and surrogate sensors. This paper reviews the initial hardware development, demonstration requirements, and the modifications/improvements made to deploy the systems for this effort. It then summarizes the feedback garnered from EM operators who used the systems at the DOE facility. (authors)
Decommissioning, Demolition and Disposal of 'hot' facilities (D3) is a relatively new science to the extent it has been part our public consciousness for ∼50-years. Due to the high hazard of uncontrolled exposure and the possibility of environmental release, the technologies applied to D3 have not embraced many of the recently developed engineering tools, especially those that leverage the digital and optical advances of the past 10-years. This summary paper provides an overview of how we are layering readily available technologies with sophisticated techniques to D3, ranging from agile program management to advanced modular construction to augmented reality. Using this approach, we are significantly improving safety and ALARA aspects while saving costs, optimizing schedules, maintaining quality and engaging the customer and the regulator in the D3 environment. (authors)
This paper describes the development of an algorithm-based utility tool using Visual Basic that examines un-georeferenced or GPS-deprived spatial datasets (3D datasets lacking one or more of the key x, y and z components). Taking into account any known geometrical parameters which are input via a user-friendly front-end, the new code automatically evaluates attributes, including any spatial coordinate components, detects invalid survey data points and fills in bad or missing data points utilising data-specific interpolation (e.g. cubic or linear spline) of valid data points, such that local extrema are not created. Previously troublesome 2D data can be easily converted to realistic 3D contour display, integrated with other time-series data to create 4D movies, and incorporated into other existing 3D datasets. More importantly those processed and 'more complete' data can be easily stored in 3D or 4D spatial database management systems for future interrogation by using clear, realistic and intuitive 3D visualisation. Test cases are presented to demonstrate the value and versatility of the newly developed utility tool which include the 3D visualisation of: surveyed wall thicknesses of a helical coil, radiation mapping of a plant and aerial survey mapping of radiation in a region near Fukushima. (authors)
The Canberra ISOCS system has been a highly successful and technologically innovative product since its introduction about 22 years ago. The combination of field-portable HPGe detectors, flexible shield/collimator set, and accurate mathematical efficiency calibration software made in-situ gamma spectroscopy measurements very practical. Good quality in-situ measurements are economically beneficial for items that are either large or complex, in comparison to the cost, time and impracticality of extracting a sample for laboratory measurements or producing representative calibration standards. And where the item is not homogeneous [most of the time for in-situ measurement situations] an assay of a large part of the item has been shown to be more accurate than a few widely dispersed extracted samples [the normal case]. However the size, weight, cost and complexity of the full-size ISOCS system limit its usefulness in some situations. A companion device was recently introduced, and is the subject of this document. The gamma sensor is a 1 cm{sup 3} CZT detector. It is surrounded by an optional tungsten shield/collimator set with a tripod for support. The detector is powered solely by a USB connection from a laptop PC. The full power of the ISOCS efficiency calibration software can be used with this detector. This entire package is less than 15 kg, needs no cooling, and is quite rugged, in comparison to the 120 kg for ISOCS with sensitive HPGe detectors which need Liquid Nitrogen or electro-mechanical cooling. Furthermore this CZT package is about 1/3 the cost. This is a very complementary device for the many current ISOCS users, especially for quick initial evaluations or simple situations where the full energy resolution and sensitivity of the HPGe ISOCS are not needed. Operating nuclear power plants or those in the initial phases of decommissioning are prime examples. Their complex layout often precludes the deployment of the full-sized ISOCS system, whereas the CZT system can be hand-carried there and very quickly setup for a measurement. The small detector size, and therefore low efficiency, is not a disadvantage, and in many cases is an advantage due to the elevated radioactivity of the items. This can be used to assay items in tanks, spills on floors, activity on filters, waste or items in small containers, and waste in drums. In the event of an emergency, it can be quickly deployed to measure gas or liquid effluent streams, air particulate and iodine filters in the field, or even in-vivo thyroid activity. Examples of measurements at nuclear facilities are shown and discussed in further detail, along with estimated detection limits. (authors)