Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “County”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Characterizing natural fractures and sub-seismic faults for well completion of Marcellus shale in the MSEEL Consortium project, West Virginia, USA

The Middle Devonian Marcellus shale play has emerged as a major world-class hydrocarbon accumulation and represents one of the largest and most prolific shale plays in the world. According to many outcrop studies in the region, natural fractures are well developed in the Marcellus Shale. However, evaluating fractures in the subsurface is often a significant challenge due to a lack of sufficient data. Therefore, in the Marcellus Shale Energy and Environment Laboratory (MSEEL) consortium project, significant efforts have been made to acquire high-quality image logs in the Marcellus laterals. The project provided tremendous opportunities to characterize the natural fractures and sub-seismic faults and to evaluate their impact on well stimulation. In this study, about 70,000 ft of acquired high-resolution logging while drilling (LWD) acoustic images from five long laterals located in Monongalia County, West Virginia, were processed and interpreted. In addition, the study used high-quality micro-resistivity images from a pilot well, allowing the evaluation of natural fractures in the entire Marcellus vertical sequence. Based on the available acoustic images, the natural fractures were classified into three basic categories: high-amplitude fractures, low-amplitude fractures, and faults. Further, larger open fractures can also be determined when a low-amplitude fracture is evident on caliper images. The fractures in the Marcellus usually have a medium to high angle dip; however, multiple fracture sets in terms of strike orientation were clearly observed in all the laterals. The fracture set with a strike at NE-SW (or 60-240 deg) seems to be the predominant one in all the wells. A few other sets, including those with N-S, NWW-SEE, and E-W strikes, were also observed. Several sub-seismic faults, with mostly a low dip angle and a NE-SW strike, have also been seen in two of the laterals. The fracture density is variable across all the laterals, ranging from very low (or none) to very high (up to 5 fractures per ft). The average fracture density for all the laterals is about 1 fracture per 10 ft. In the vertical sequence, the natural fracture development showed a clear preference for shale or shaly facies over carbonate-rich or thin limestone layers. The interpreted fracture and fault data were used as input data for the stimulation design with the purpose of better understanding the fractures’ impact on well stimulation. Production data from the laterals were also used to evaluate the natural fractures’ influence on well performance. The quality image database and the consistent interpretation results for the entire project enabled a systematic approach to characterizing fractures and, more importantly, to evaluating the impact of fractures on well stimulation and production.

03 NATURAL GAS↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Kentucky: Using LEAD Tool Data to Fund Energy Efficiency Programs

The Kentucky Office of Energy Policy (OEP) applied the U.S. Department of Energy’s (DOE’s) web-based Low-Income Energy Affordability Data (LEAD) Tool to identify areas of their state with energy affordability needs. Kentucky OEP staff used the LEAD Tool to identify counties in Kentucky with the highest energy burden, which is the percentage of household income spent on energy. With this knowledge, Kentucky OEP staff allocated funds to relevant nonprofit organizations that provide home repairs, weatherization upgrades, and other solutions in areas where these services have the highest potential energy saving benefits and can reduce energy burden.

Low-Income Energy Affordability Data Tool, LEAD To↗

Opportunities for Solar Industrial Process Heat in the United States

This presentation summarizes the first national analysis of opportunities for solar technologies to provide industrial process heat (IPH) in the United States. The industrial sector is a major end-user of energy and IPH constitutes a majority of industrial fuel energy. New disaggregations of IPH demands are made at the temporal, geographic, and operational levels. Solar heat generation by seven solar thermal technologies and PV-connected electrotechnologies are modeled using county solar resources and land availability and matched to relevant IPH demands. Parabolic trough collectors (PTC), when combined with thermal energy storage (TES), not only have the largest opportunity in terms of distribution over geography and time, but also in terms of applicable IPH demands. PTC with TES represents the displacement of nearly 2,500 trillion Btus of combustion fuels, which corresponds to 137 million metric tons of CO2, or about 15% of all industrial combustion CO2 emissions. TES, along with site-level analysis, are identified as areas of further analysis.

41 EE - Solar Energy Technologies Office (EE-4S)↗

NEVADA NATIONAL SECURITY SITE 2020 DATA REPORT- GROUNDWATER MONITORING PROGRAM AREA 5 RADIOACTIVE WASTE MANAGEMENT SITE

This report presents groundwater and leachate sample results from the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site in Nye County, Nevada. Since 1993, groundwater samples have been collected and static groundwater depths have been measured from the aquifer immediately below the Area 5 RWMS. The data are evaluated for evidence of effects on the aquifer related to the Area 5 RWMS. Leachate from the Cell 18 lined mixed waste cell has been sampled since 2011, and leachate from the Cell 25 lined mixed waste cell was first sampled in 2019 after it began receiving waste in August 2018. Leachate data are analyzed for hazardous contaminants to determine appropriate leachate handling and disposal. This report includes five years of data from 2016 through 2020.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗