Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Angular-resolution and material-characterization measurements for a dual-particle imaging system with mixed-oxide fuel

A dual-particle imaging (DPI) system, capable of simultaneously imaging fast neutrons and gamma rays, has been operated in the presence of mixed-oxide (MOX) fuel to assess the system's angular resolution and material-characterization capabilities. The detection principle is based on the scattering physics of neutrons (elastic scattering) and gamma rays (Compton scattering) in organic and inorganic scintillators. The detection system is designed as a combination of a two-plane Compton camera and a neutron-scatter camera. The front plane consists of EJ-309 liquid scintillators and the back plane consists of interleaved EJ-309 and NaI(Tl) scintillators. MCNPX-PoliMi was used to optimize the geometry of the system and the resulting prototype was built and tested using a Cf-252 source as an SNM surrogate. A software package was developed to acquire and process data in real time. The software was used for a measurement campaign to assess the angular resolution of the imaging system with MOX samples. Measurements of two MOX canisters of similar isotopics and intensity were performed for 6 different canister separations (from 5° to 30°, corresponding to distances of 21 cm and 131 cm, respectively). The measurements yielded a minimum separation of 20° at 2.5 m (86-cm separation) required to see 2 separate hot spots. Additionally, the results displayed good agreement with MCNPX-PoliMi simulations. These results indicate an angular resolution between 15° and 20°, given the 5° step. Coupled with its large field of view, and its capability to differentiate between spontaneous fission and (α,n) sources, the DPI system shows its potential for nuclear-nonproliferation applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Ge-microstrip imaging detector and polarimeter

Using 98% linearly polarized radiation at the European Synchrotron Radiation Facility in Grenoble, the performance of a prototype two-dimensional microstrip Ge(i) detector for x-ray imaging and as a Compton polarimeter has been evaluated. Using the energy and position sensitivity of the detector, the ability to obtain a complete reconstruction of the Compton event has been demonstrated. The modulation coefficient of the polarimeter is in good agreement with the theoretical limit of a perfect detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization Measurements of Radiative Electron Capture Transitions in Highly Charged Ions

A dedicated Si(Li) Compton polarimeter combining energy and time resolution with a large detection area of 64x64 mm{sup 2} and a two dimensional position resolution of 2 mm has been used for the first time to study the polarization of x-rays emitted via radiative electron capture (REC) into the K and L-shell of heavy highly charged ions. First data for the collision system 96.6 MeV/u U{sup 92+}{yields}H{sub 2} are presented. The angular distribution of the Compton scattered photons inside the detector indicates that both K- and L-REC processes lead to the emission of strongly linearly polarized light.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multiwavelength Coverage of a Bright Flare from Sgr A

The dynamical center of our galaxy hosts a supermassive black hole, Sgr A*, which has been the target of an extensive multiwavelength campaign for a week in April 2007. We report here the detection of a bright flare from the vicinity of the horizon, observed simultaneously in X-rays (XMM-Newton) and NIR (VLT/NACO) on April 4{sup th}. For the first time, such an event also benefitted from a soft {gamma}-rays (INTEGRAL/ISGRI) and MIR (VLT/VISIR) coverage, which enabled us to derive upper limits at both ends of Sgr A* spectral energy distribution (SED). We discuss the physical implications of the contemporaneous light curves as well as the SED, in terms of synchrotron, synchrotron self-Compton and external Compton emission processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Heavily Obscured AGN with SIMBOL-X

By comparing an optically selected sample of narrow lines AGN with an X-ray selected sample of AGN we have recently derived an estimate of the intrinsic (i.e. before absorption) 2-10 keV luminosity function (XLF) of Compton Thick AGNs. We will use this XLF to derive the number of Compton Thick AGN that will be found in the SIMBOL-X survey(s)

79 ASTRONOMY AND ASTROPHYSICS↗

Generalized Parton Distributions: Status and Perspectives

We summarize recent developments in understanding the concept of generalized parton distributions (GPDs), its relation to nucleon structure, and its application to high-Q{sup 2} electroproduction processes. Following a brief review of QCD factorization and transverse nucleon structure, we discuss (a) new theoretical methods for the analysis of deeply-virtual Compton scattering (t-channel-based GPD parametrizations, dispersion relations); (b) the phenomenology of hard exclusive meson production (experimental tests of dominance of small-size configurations, model-independent comparative studies); (c) the role of GPDs in small-x physics and pp scattering (QCD dipole model, central exclusive diffraction). We emphasize the usefulness of the transverse spatial (or impact parameter) representation for both understanding the reaction mechanism in hard exclusive processes and visualizing the physical content of the GPDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NEW DEVELOPMENTS IN DIGITAL X-RAY TECHNIQUES: A SIMULATION TOOL FOR SCATTERING IMAGING

This paper focus mainly on a simulation tool used to compute X-ray imaging technique and the last developments with the calculation of the scattering. It allows evaluating the scattered contribution on a transmission detector but also simulating scattering technique as Compton or Rayleigh tomography. A major interest of the Compton scattering technique is that the experimental device is located on one side of the object, and thus, an image can be acquired even if we can not access to the other side of the object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Plasma Accelerators for Medical and Nuclear Uses

Starting from the cases of the current clinical facilities as a source of reference to compare with, final performance of lasers and accelerators and even cost target were discussed. We assume maximum flexibility to enable treatment of small as well as large in-depth tumor volumes requiring the maximum energy of 250 MeV for protons and 400 MeV/u for carbon. We adopt their reference numbers for the required total number of protons / carbon ions per fraction (5 min) as well as peak numbers (per second). Other parameters (like energy spread and total number of voxels) are adjusted to the particularities of laser acceleration, which include a much higher production energy spread than in the synchrotron case and a laser pulse rate currently suggested by technology. As far as cost, it is assumed that a single laser driver unit is foreseen for one treatment room. It is suggested that the target for 10-20 years of development could be a cost of the laser driver unit not exceeding 1/4 of the conventional synchrotron facility cost, which is 40 MEuro. Further, design study, proposal and preliminary experimental results for all optical Compton scattering X-ray source for nuclear material detection at University of Tokyo is introduced. By using the Ti:Sapphire laser at about 7 TW and our original gas-jet and magnetic plasma channel, we succeeded in generating more than 100 MeV electrons with a reasonable emittance. Compton scattering with beam-spread Ti:Sapphire laser pulse can yield quasi-monochromatic X-rays around 110 keV near the K-edges of U, Np, Pu. Subtraction imaging across the K-edge realizes clear recognition and distingushment of those compounds in liquid.

43 PARTICLE ACCELERATORS↗

Prospects for DVCS measurements using the COMPASS spectrometer at CERN

The study of exclusive reactions like Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP) is one major part of the future COMPASS program to investigate nucleon structure through Generalized Parton Distributions (GPD). The high energy of the muon beam allows to measure the x{sub Bj}-dependence of the t-slope of the DVCS cross section and to study nucleon tomography. The use of positive and negative polarized muon beams allows to determine the Beam Charge and Spin Difference of the DVCS cross sections to access the real part of the Compton form factor related to the dominant GPD H. As a second phase a transversely polarized proton target will be used to collect data to constrain the GPD E. In preparation of the future measurements two DVCS test runs were performed in 2008 and 2009.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proposal for GPD studies at COMPASS

The study of nucleon structure through Generalised Parton Distributions (GPD) is one major part of the future COMPASS-II physics program and can be performed using exclusive reactions like Deeply Virtual Compton Scattering (DVCS) and Meson Production. The high energy of the muon beam allows to measure the x{sub B}-dependence of the t-slope of the DVCS cross section. The use of positive and negative polarised muon beams allows to determine the Beam Charge and Spin Difference of the DVCS cross sections to access the real part of the Compton form factor related to the dominant GPD H. The sensitivity of both measurements is examined and confronted to existing models or global fits of the data. Preliminary beam test data were analyzed and demonstrated the feasibility of the identification of the DVCS reaction using the COMPASS experimental set-up.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A collimator for hot plasma x-ray diagnostics in ion sources

We present a collimator configuration for measuring energy resolved x-ray plasma volume bremsstrahlung emitted, e.g., by an ECRIS. Special attention we paid to shielding the detector against interfering Compton scattered radiation and wall bremsstrahlung stemming from the collimator entrance aperture. We estimate the efficiency for shielding of Compton scattered radiation at least attainable by this arrangement.

43 PARTICLE ACCELERATORS↗

Gamma-to-electron magnetic spectrometer (GEMS): An energy-resolved {gamma}-ray diagnostic for the National Ignition Facility

The gamma-to-electron magnetic spectrometer, having better than 5% energy resolution, is proposed to resolve {gamma}-rays in the range of E{sub o}{+-} 20% in single shot, where E{sub o} is the central energy and is tunable from 2 to 25 MeV. Gamma-rays from inertial confinement fusion implosions interact with a thin Compton converter (e.g., beryllium) located at approximately 300 cm from the target chamber center (TCC). Scattered electrons out of the Compton converter enter an electromagnet placed outside the NIF chamber (approximately 600 cm from TCC) where energy selection takes place. The electromagnet provides tunable E{sub o} over a broad range in a compact manner. Energy resolved electrons are measured by an array of quartz Cherenkov converters coupled to photomultipliers. Given 100 detectable electrons in the energy bins of interest, 3 Multiplication-Sign 10{sup 14} minimum deuterium/tritium (DT) neutrons will be required to measure the 4.44 MeV {sup 12}C {gamma}-rays assuming 200 mg/cm{sup 2} plastic ablator areal density and 3 Multiplication-Sign 10{sup 15} minimum DT neutrons to measure the 16.75 MeV DT {gamma}-ray line.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Covariance analysis of gamma ray spectra

The covariance method exploits fluctuations in signals to recover information encoded in correlations which are usually lost when signal averaging occurs. In nuclear spectroscopy it can be regarded as a generalization of the coincidence technique. The method can be used to extract signal from uncorrelated noise, to separate overlapping spectral peaks, to identify escape peaks, to reconstruct spectra from Compton continua, and to generate secondary spectral fingerprints. We discuss a few statistical considerations of the covariance method and present experimental examples of its use in gamma spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GPD physics with polarized muon beams at COMPASS-II

A major part of the future COMPASS program is dedicated to the investigation of the nucleon structure through Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP). COMPASS will measure DVCS and DVMP reactions with a high intensity muon beam of 160 GeV and a 2.5 m-long liquid hydrogen target surrounded by a new TOF system. The availability of muon beams with high energy and opposite charge and polarization will allow to access the Compton form factor related to the dominant GPD H and to study the x{sub B}-dependence of the t-slope of the pure DVCS cross section and to study nucleon tomography. Projections on the achievable accuracies and preliminary results of pilot measurements will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the scalar and vector polarizabilities of the nucleon using polarized photons and electrons

The next generation of Compton scattering experiments is underway at Mainz and other laboratories, where the goal is precision measurements of the scalar and vector polarizabilities of the nucleon using polarized photons and polarized targets. Results are presented for the first double polarized Compton scattering experiment utilizing a polarized proton target. Preliminary results are presented for the γ{sub E1E1} spin polarizability. Prospects are discussed for future nucleon polarizability measurements using a high intensity 300 MeV electron machine.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron polarimetry at low energies in Hall C at JLab

Although the majority of Jefferson Lab experiments require multi-GeV electron beams, there have been a few opportunities to make electron beam polarization measurements at rather low energies. This proceedings will discuss some of the practical difficulties encountered in performing electron polarimetry via Mo/ller scattering at energies on the order of a few hundred MeV. Prospects for Compton polarimetry at very low energies will also be discussed. While Mo/ller scattering is likely the preferred method for electron polarimetry at energies below 500 MeV, there are certain aspects of the polarimeter and experiment design that must be carefully considered.

43 PARTICLE ACCELERATORS↗

Magnetic switching behaviors of orbital states with different magnetic quantum numbers in Au/Fe/MgO multilayer system

A spin specific magnetic hysteresis (SSMH) curve and an orbital specific magnetic hysteresis (OSMH) curve are obtained for Fe/Au/Fe/MgO multilayers by magnetic Compton scattering and SQUID magnetometer measurements. The SSMH curve with each contribution of magnetic quantum number |m| = 0, 1, and 2 states is obtained by decomposition analyses of magnetic Compton profiles. Residual magnetization is observed for the SSMH curve with magnetic quantum number |m| = 0, 2 and the OSMH curve. Although the SQUID magnetometer measurements do not show perpendicular magnetic anisotropy (PMA) in the present Fe/Au/Fe/MgO multilayer film, the SSMH curve with magnetic quantum number |m| = 0, 2 and OSMH curve show switching behaviors of PMA.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗