Split stator vane row for fans and compressors
Operating noise of fans is reduced by adding part span vanes to vane row of stator, reducing the number of full span vanes and maintaining a vane-to-blade ratio of about 2 to 1.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Operating noise of fans is reduced by adding part span vanes to vane row of stator, reducing the number of full span vanes and maintaining a vane-to-blade ratio of about 2 to 1.
Noise reduction of Boeing 707 during landing approach by modifying turbofan nacelle with polyimide fiber glass acoustic sandwich materials
Static tests to determine effects of throat inlet concepts on forward-radiated fan noise of 707-320B/C airplanes
Subjective evaluation tests of ground observers on relative noise from acoustically treated engine nacelles of Boeing 707 aircraft
Description of system for recording and reading out data related to distribution of occurrence of plurality of events
Design and characteristics of 28-inch diameter seals for air breathing propulsion systems - Part 1
The performance data were taken at 50,000 rpm, using argon gas. As the Reynolds number was reduced from near design value to 30 percent of design, the maximum efficiency decreased about 1.5 percentage points. Reducing the Reynolds number from 30 percent to approximately 10 percent of design caused the maximum efficiency to decrease another 2.5 percentage points. The variation in loss with Reynolds number is compared with inverse power relation of loss with Reynolds number.
The program will determine the velocities in the meridional plane of a backward-swept impeller, a radial impeller, and a vaned diffuser. The velocity gradient equation with the assumption of a hub-to-shroud mean stream surface is solved along arbitrary quasi-orthogonals in the meridional plane. These quasi-orthogonals are fixed straight lines.
A conventional rotor and stator, two dual-airfoil tandem rotors, and one dual-airfoil tandem stator were designed. The two tandem rotors were each designed with different percentages of the overall lift produced by the front airfoil. Velocity diagrams and blade leading and trailing edge metal angles selected for the conventional rotor and stator blading were used in the design of the tandem blading. Rotor inlet hub/tip ratio was 0.8. Design values of rotor tip velocity and stage pressure ratio were 757 ft/sec and 1.30, respectively.
Stage A, comprised of a conventional rotor and stator, was designed and tested to establish a performance baseline for comparison with the results of subsequent tests planned for two tandem-blade stages. The rotor had an inlet hub/tip ratio of 0.8 and a design tip velocity of 757 ft/sec. At design equivalent rotor speed, rotor A achieved a maximum adiabatic efficiency of 85.1 percent at a pressure ratio of 1.29. The stage maximum adiabatic efficiency was 78.6 percent at a pressure ratio of 1.27.
Stage C, comprised of tandem-airfoil rotor C and tandem-airfoil stator B, was designed and tested to establish performance data for comparison with the performance of conventional single-airfoil blading. Velocity diagrams and blade leading and trailing edge metal angles selected for the conventional rotor and stator blading were used in the design of the tandem blading. The rotor had an inlet hub/tip ratio of 0.8 and a design tip velocity of 757 ft/sec. At design equivalent rotor speed, rotor C achieved a maximum adiabatic efficiency of 91.8% at a pressure ratio of 1.31. The stage maximum adiabatic efficiency was 86.5% at a pressure ratio of 1.31.
The application of the nonsteady Lax-Wendroff technique to problems with asymptotically periodic solution which offers a potentially powerful method for the investigation of the interaction of rotating and stationary blade rows in turbomachinery is reported. A technique for specifying boundary conditions with phase lag was developed to accomplish this. A complete nonlinear analysis is carried out numerically to determine the entire flow field without recourse to the assumption of small disturbances of linear equations which underlie the previous acoustic theories. The result, obtained for the case of equal number of rotor and stator blades shows that transonic flow can be handled without difficulty. In addition, the program is not limited with regard to blade thickness, camber or loading. Extension of this method to incorporate viscous wakes and to analysis of fully three dimensional configuration is feasible, and would greatly expand its utility in practical applications.
A single stage fan with a tip speed of 1800 ft/sec (548.6m/sec) and hub/tip ratio of 0.5 was designed to produce a pressure ratio of 2.285:1 with an adiabatic efficiency of 84.0%. The design flow per inlet annulus area is 38.7 lbm/sq ft-sec (188.9KG/sqm-sec). Rotor blades have modified multiple-circular-arc and precompression airfoil sections. The stator vanes have multiple-circular-arc airfoil sections.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Slope-threshold compression scheme for telemetered video data is efficient, and its principle of operation is as follows: when slope of raw data exceeds threshold decision reference, previous sample is transmitted. All-digital design is more economical than analog system. It exhibits well-defined accuracy, provides unlimited storage time, and is convenient and reliable.
The transient performance of two concepts for control of vertical takeoff aircraft remote lift fans is analyzed and discussed. Both concepts employ flow transfer between pairs of lift fans located in separate parts of the aircraft in order to obtain attitude control moments for hover and low-speed flight. The results presented are from a digital computer, dynamic analysis of the YJ97/LF460 remote drive turbofan. The transient responses of the two systems are presented for step demands in lift and moment.
Two new concepts of control for VTOL aircraft remote lift fans are analyzed and discussed. Both concepts employ flow transfer among lift fans located in separate parts of the aircraft in order to obtain attitude control moments in hover and low-speed flight. The results presented are from a digital computer analysis of the YJ97/LF460 remote drive turbofan, although qualitative conclusions should apply to any remote fan system. The basic operating principles of the two systems are described, and their steady-state moment generating capabilities are discussed. Lift-recovery strategies for component failures are also analyzed.