Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cleaning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Evaluation of the Effect of Silicone Contamination on Various Bond Systems and the Feasibility of Removing the Contamination

Silicone is a contaminant that can cause catastrophic failure of a bond system depending on the materials and processes used to fabricate the bond system, Unfortunately, more and more materials are fabricated using silicone. The purpose of this testing was to evaluate which bond systems are sensitive to silicone contamination and whether or not a cleaning process could be utilized to remove the silicone to bring the bond system performance back to baseline. Due to the extensive nature of the testing attempts will be made to generalize the understanding within classes of substrates, bond systems, and surface preparation and cleaning methods. This study was done by contaminating various meta! (steel, inconel, and aluminum), phenolic (carbon cloth phenolic and glass cloth phenolic), and rubber (natural rubber, asbestos-silicone dioxide filled natural butyldiene rubber, silica-filled ethylene propylenediene monomer, and carbon-filled ethylene propylenediene monomer) substrates which were then bonded using various adhesives and coatings (epoxy-based adhesives, paints, ablative compounds, and Chemlok adhesives) to determine the effect silicone contamination has on a given bond system's performance. The test configurations depended on the bond system being evaluated. The study also evaluated the feasibility of removing the silicone contamination by cleaning the contaminated substrate prior to bonding. The cleaning processes also varied depending on bond system.

Stanley, Stephanie D.↗

Microfluidic Mixing Technology for a Universal Health Sensor

A highly efficient means of microfluidic mixing has been created for use with the rHEALTH sensor an elliptical mixer and passive curvilinear mixing patterns. The rHEALTH sensor provides rapid, handheld, complete blood count, cell differential counts, electrolyte measurements, and other lab tests based on a reusable, flow-based microfluidic platform. These geometries allow for cleaning in a reusable manner, and also allow for complete mixing of fluid streams. The microfluidic mixing is performed by flowing two streams of fluid into an elliptical or curvilinear design that allows the combination of the flows into one channel. The mixing is accomplished by either chaotic advection around micro - fluidic loops. All components of the microfluidic chip are flow-through, meaning that cleaning solution can be introduced into the chip to flush out cells, plasma proteins, and dye. Tests were performed on multiple chip geometries to show that cleaning is efficient in any flowthrough design. The conclusion from these experiments is that the chip can indeed be flushed out with microliter volumes of solution and biological samples are cleaned readily from the chip with minimal effort. The technology can be applied in real-time health monitoring at patient s bedside or in a doctor s office, and real-time clinical intervention in acute situations. It also can be used for daily measurement of hematocrit for patients on anticoagulant drugs, or to detect acute myocardial damage outside a hospital.

Chan, Eugene Y.↗

Rarefying Spectra of Whispering-Gallery-Mode Resonators

A method of cleaning the mode spectra of whispering-gallery-mode (WGM) optical resonators has been devised to make such resonators more suitable for use as narrow-band optical filters. The method applies, more specifically, to millimeter- sized whispering-gallery-mode optical resonators that are made of crystalline electro-optical materials and have ultrahigh values of the resonance quality factor (Q). The mode spectrum of such a resonator is typically dense, consisting of closely spaced families of modes; as such, the spectrum is not well suited for narrow-band filtering, in which there is a need for strong rejection of side modes. Cleaning as used here signifies rarefying the spectrum so that what remains consists mostly of a single desired family of modes or, at worst, a few mode families that are more widely spaced in frequency than are the mode families in the original, non-rarefied spectrum. The spectrum-cleaning method exploits the fact that various WGM mode families occupy various positions near the equator at the rim of a resonator disk. In this method, a damper in the form of a prism or other polished piece of material having an index of refraction greater than that of the resonator material is placed in contact with the rim of the resonator at such a position that the Qs of most or all of the undesired mode families are greatly reduced while the Q of the desired mode family is reduced by only a tolerably small amount. In an alternative method that has been considered, the mode spectrum would be cleaned through special design of the shape of the rim, but fabrication of the rim in a special shape is a complicated task. The advantage of the present method, relative to the alternative method, is that special shaping of the rim is not necessary and the damping prism can be emplaced after the resonator has been fabricated.

Savchenkov, Anatoliy↗

Microbiological Tests Performed During the Design of the International Space Station Environmental Control and Life Support Systems. Part 1, Bulk Phase: Bulk Phase - Part 1

The design and manufacturing of the main Environmental Control and Life Support Systems (ECLSS) for the United States segments of the International Space Station (ISS) was an involved process that started in the mid 1980s, with the assessment and testing of competing technologies that could be used to clean the air and recycle water. It culminated in 2009 with the delivery and successful activation of the Water Recovery System (WRS) water processor (WP). The ECLSS required the work of a team of engineers and scientist working together to develop systems that could clean and/or recycle human metabolic loads to maintain a clean atmosphere and provide the crew clean water. One of the main goals of the ECLSS is to minimize the time spent by the crew worrying about vital resources not available in the vacuum of space, which allows them to spend most of their time learning to live in a microgravity environment many miles from the comforts of Earth and working on science experiments. Microorganisms are a significant part of the human body as well as part of the environment that we live in. Therefore, the ISS ECLSS design had to take into account the effect microorganisms have on the quality of stored water and wastewater, as well as that of the air systems. Hardware performance issues impacted by the accumulation of biofilm and/or microbiologically influenced corrosion were also studied during the ECLSS development stages. Many of the tests that were performed had to take into account the unique aspects of a microgravity environment as well as the challenge of understanding how to design systems that could not be sterilized or maintained in a sterile state. This paper will summarize the work of several studies that were performed to assess the impacts and/or to minimize the effects of microorganisms in open, semi-closed and closed loop life support system. The biofilm and biodeterioration studies that were performed during the design and test periods will be presented in a future publication.

Roman, Monsi C.↗

Overview of Microbiological Tests Performed During the Design of the International Space Station Environmental Control and Life Support Systems

The design and manufacturing of the main Environmental Control and Life Support Systems (ECLSS) for the United States segments of the International Space Station (ISS) was an involved process that started in the late 1980's, with the assessment and testing of competing technologies that could be used to clean the air and recycle water. It culminated in 2009 with the delivery and successful activation of the Water Recovery System (WRS) water processor (WP). The ECLSS required the work of a team of engineers and scientist working together to develop systems that could clean and/or recycle human metabolic loads to maintain a clean atmosphere and provide the crew clean water. One of the main goals of the ECLSS is to minimize the time spent by the crew worrying about vital resources not available in the vacuum of space, which allows them to spend most of their time learning to live in a microgravity environment many miles from the comforts of Earth and working on science experiments. Microorganisms are a significant part of the human body as well as part of the environment that we live in. Therefore, the ISS ECLSS design had to take into account the effect microorganisms have on the quality of stored water and wastewater, as well as that of the air systems. Hardware performance issues impacted by the accumulation of biofilm and/or microbiologically influenced corrosion were also studied during the ECLSS development stages. Many of the tests that were performed had to take into account the unique aspects of a microgravity environment as well as the challenge of understanding how to design systems that could not be sterilized or maintained in a sterile state. This paper will summarize the work of several studies that were performed to assess the impacts and/or to minimize the effects of microorganisms in the design of a closed loop life support system.

Roman, Monsi C.↗

Recovery, Transportation and Acceptance to the Curation Facility of the Hayabusa Re-Entry Capsule

The "Hayabusa" re-entry capsule was safely carried into the clean room of Sagamihara Planetary Sample Curation Facility in JAXA on June 18, 2010. After executing computed tomographic (CT) scanning, removal of heat shield, and surface cleaning of sample container, the sample container was enclosed into the clean chamber. After opening the sample container and residual gas sampling in the clean chamber, optical observation, sample recovery, sample separation for initial analysis will be performed. This curation work is continuing for several manths with some selected member of Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). We report here on the 'Hayabusa' capsule recovery operation, and transportation and acceptance at the curation facility of the Hayabusa re-entry capsule.

Abe, M.↗

Technical Tension Between Achieving Particulate and Molecular Organic Environmental Cleanliness: Data from Astromaterial Curation Laboratories

NASA Johnson Space Center operates clean curation facilities for Apollo lunar, Antarctic meteorite, stratospheric cosmic dust, Stardust comet and Genesis solar wind samples. Each of these collections is curated separately due unique requirements. The purpose of this abstract is to highlight the technical tensions between providing particulate cleanliness and molecular cleanliness, illustrated using data from curation laboratories. Strict control of three components are required for curating samples cleanly: a clean environment; clean containers and tools that touch samples; and use of non-shedding materials of cleanable chemistry and smooth surface finish. This abstract focuses on environmental cleanliness and the technical tension between achieving particulate and molecular cleanliness. An environment in which a sample is manipulated or stored can be a room, an enclosed glovebox (or robotic isolation chamber) or an individual sample container.

Allton, J. H.↗

Aerodynamic Effects of Simulated Ice Accretion on a Generic Transport Model

An experimental research effort was begun to develop a database of airplane aerodynamic characteristics with simulated ice accretion over a large range of incidence and sideslip angles. Wind-tunnel testing was performed at the NASA Langley 12-ft Low-Speed Wind Tunnel using a 3.5 percent scale model of the NASA Langley Generic Transport Model. Aerodynamic data were acquired from a six-component force and moment balance in static-model sweeps from alpha = -5deg to 85deg and beta = -45 deg to 45 deg at a Reynolds number of 0.24 x10(exp 6) and Mach number of 0.06. The 3.5 percent scale GTM was tested in both the clean configuration and with full-span artificial ice shapes attached to the leading edges of the wing, horizontal and vertical tail. Aerodynamic results for the clean airplane configuration compared favorably with similar experiments carried out on a 5.5 percent scale GTM. The addition of the large, glaze-horn type ice shapes did result in an increase in airplane drag coefficient but had little effect on the lift and pitching moment. The lateral-directional characteristics showed mixed results with a small effect of the ice shapes observed in some cases. The flow visualization images revealed the presence and evolution of a spanwise-running vortex on the wing that was the dominant feature of the flowfield for both clean and iced configurations. The lack of ice-induced performance and flowfield effects observed in this effort was likely due to Reynolds number effects for the clean configuration. Estimates of full-scale baseline performance were included in this analysis to illustrate the potential icing effects.

Broeren, Andy P.↗

Qualifications of Bonding Process of Temperature Sensors to Deep-Space Missions

A process has been examined for bonding a platinum resistance thermometer (PRT) onto potential aerospace materials such as flat aluminum surfaces and a flexible copper tube to simulate coaxial cables for flight applications. Primarily, PRTs were inserted into a silver-plated copper braid to avoid stresses on the sensor while the sensor was attached with the braid to the base material for long-duration, deep-space missions. A1-1145/graphite composite (planar substrate) and copper tube have been used in this study to assess the reliability of PRT bonding materials. A flexible copper tube was chosen to simulate the coaxial cable to attach PRTs. The substrate materials were cleaned with acetone wipes to remove oils and contaminants. Later, the surface was also cleaned with ethyl alcohol and was air-dried. The materials were gently abraded and then were cleaned again the same way as previously mentioned. Initially, shielded (silver plated copper braid) PRT (type X) test articles were fabricated and cleaned. The base antenna material was pretreated and shielded, and CV-2566 NuSil silicone was used to attach the shielded PRT to the base material. The test articles were cured at room temperature and humidity for seven days. The resistance of the PRTs was continuously monitored during the thermal cycling, and the test articles were inspected prior to, at various intermediate steps during, and at the end of the thermal cycling as well. All of the PRTs survived three times the expected mission life for the JUNO project. No adhesion problems were observed in the PRT sensor area, or under the shielded PRT. Furthermore, the PRT resistance accurately tracked the thermal cycling of the chamber.

Ramesham, Rajeshuni↗

Genesis Ultrapure Water Megasonic Wafer Spin Cleaner

A device removes, with high precision, the majority of surface particle contamination greater than 1-micron-diameter in size from ultrapure semiconductor wafer materials containing implanted solar wind samples returned by NASA's Genesis mission. This cleaning device uses a 1.5-liter/minute flowing stream of heated ultrapure water (UPW) with 1- MHz oscillating megasonic pulse energy focused at 3 to 5 mm away from the wafer surface spinning at 1,000 to 10,000 RPM, depending on sample size. The surface particle contamination is removed by three processes: flowing UPW, megasonic cavitations, and centripetal force from the spinning wafer. The device can also dry the wafer fragment after UPW/megasonic cleaning by continuing to spin the wafer in the cleaning chamber, which is purged with flowing ultrapure nitrogen gas at 65 psi (.448 kPa). The cleaner also uses three types of vacuum chucks that can accommodate all Genesis-flown array fragments in any dimensional shape between 3 and 100 mm in diameter. A sample vacuum chuck, and the manufactured UPW/megasonic nozzle holder, replace the human deficiencies by maintaining a consistent distance between the nozzle and wafer surface as well as allowing for longer cleaning time. The 3- to 5-mm critical distance is important for the ability to remove particles by megasonic cavitations. The increased UPW sonication time and exposure to heated UPW improve the removal of 1- to 5-micron-sized particles.

Allton, Judith H.↗

Reducing Organic Contamination in NASA JSC Astromaterial Curation Facility

Future robotic and human spaceflight missions to the Moon, Mars, asteroids and comets will require handling and storing astromaterial samples with minimal inorganic and organic contamination to preserve the scientific integrity of each sample. Much was learned from the rigorous attempts to minimize and monitor organic contamination during Apollo, but it was not adequate for current analytical requirements; thus [1]. OSIRIS-REx, Hayabusa-2, and future Mars sample return will require better protocols for reducing organic contamination. Future isolation con-tainment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study established the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs [2, 3]. After standard ultra-pure water (UPW) cleaning, the majority of organic contaminates found were hydrocarbons, plasticizers, silicones, and solvents. Hydro-carbons loads (> C7) ranged from 1.9 to 11.8 ng/cm2 for TD-GC-MS wafer exposure analyses and 5.0 to 19.5 ng/L for TD-GC-MS adsorbent tube exposure. Plasticizers included < 0.6 ng/cm2 of DBP, DEP, TXIB, and DIBP. Silicones included < 0.5 ng/cm2 of cyclo(Me2SiO)x (x = 6, 8, 9, 10) and siloxane. Solvents included < 1.0 ng/cm2 of 2-cyclohexen-1-one, 3,5,5-trimethyl- (Isopho-rone), N-formylpiperidine, and 2-(2-butoxyethoxy) ethanol. In addition, DBF, rubber/polymer additive was found at < 0.2 ng/cm2 and caprolactam, nylon-6 at < 0.6 ng/cm2. Reducing Organics: The Apollo program was the last sam-ple return mission to place high-level organic requirements and biological containment protocols on a curation facility. The high vacuum complex F-201 glovebox in the Lunar Receiving Labora-tory used ethyl alcohol (190 proof), 3:1 benzene/methanol (nano grade solution), and heat sterilization at 130degC for 48 hours to reduce organic contamination. In addition, both heat sterilization and peracetic acid sterilization were used in the atmospheric de-contamination (R) cabinets. Later, Lunar curation gloveboxes were degreased with a pressurized Freon 113 wash. Today, UPW has replaced Freon as the standard cleaning procedure, but does not have the degreasing solvency power of Freon. Future Cleaning Studies: Cleaning experiments are cur-rently being orchestrated to study how to degrease and reduce organics in a JSC curation glovebox lower than the established baseline. Several new chemicals in the industry have replaced traditional degreasing solvents such as Freon and others that are now federally restricted. However, these new suites of chemicals remain untested for lowering organics in curation gloveboxes. 3M's HFE-7100DL and DuPont's Vertrel XF are currently being tested as a replacement for Freon 113 as a degreaser at JSC cura-tion facilities. In addition, the use of UPW as a final rinse is be-ing tested, which presumably can maintain a lower total organic carbon load than the filtered purity of chemical solutions. References: [1] Allton J.H. et al. (2012) LPS XLIII, 2439; [2] Calaway M.

Calaway, M. J.↗

The Hayabusa Curation Facility at Johnson Space Center

The Japan Aerospace Exploration Agency (JAXA) Hayabusa spacecraft made contact with the asteroid 25143 Itokawa and collected regolith dust from Muses Sea region of smooth terrain [1]. The spacecraft returned to Earth with more than 10,000 grains ranging in size from just over 300 μm to less than 10 μm [2, 3]. These grains represent the only collection of material returned from an asteroid by a spacecraft. As part of the joint agreement between JAXA and NASA for the mission, 10% of the Hayabusa grains are being transferred to NASA for parallel curation and allocation. In order to properly receive process and curate these samples, a new curation facility was established at Johnson Space Center (JSC). Since the Hayabusa samples within the JAXA curation facility have been stored free from exposure to terrestrial atmosphere and contamination [4], one of the goals of the new NASA curation facility was to continue this treatment. An existing lab space at JSC was transformed into a 120 sq.ft. ISO class 4 (equivalent to the original class 10 standard) clean room. Hayabusa samples are stored, observed, processed, and packaged for allocation inside a stainless steel glove box under dry N2. Construction of the clean laboratory was completed in 2012. Currently, 25 Itokawa particles are lodged in NASA's Hayabusa Lab. Special care has been taken during lab construction to remove or contain materials that may contribute contaminant particles in the same size range as the Hayabusa grains. Several witness plates of various materials are installed around the clean lab and within the glove box to permit characterization of local contaminants at regular intervals by SEM and mass spectrometry, and particle counts of the lab environment are frequently acquired. Of particular interest is anodized aluminum, which contains copious sub-mm grains of a multitude of different materials embedded in its upper surface. Unfortunately the use of anodized aluminum was necessary in the construction of the clean room frame to strengthen it and eliminate corrosion and wear over time. All anodized aluminum interior to the lab was thus covered or replaced by minimally contaminating materials.

Zolensky, M.↗

Neutron Imaging for Selective Laser Melting Inconel Hardware with Internal Passages

Additive Manufacturing is showing great promise for the development of new innovative designs and large potential life cycle cost reduction for the Aerospace Industry. However, more development work is required to move this technology into space flight hardware production. With selective laser melting (SLM), hardware that once consisted of multiple, carefully machined and inspected pieces, joined together can be made in one part. However standard inspection techniques cannot be used to verify that the internal passages are within dimensional tolerances or surface finish requirements. NASA/MSFC traveled to Oak Ridge National Lab's (ORNL) Spallation Neutron Source to perform some non-destructive, proof of concept imaging measurements to assess the capabilities to understand internal dimensional tolerances and internal passages surface roughness. This presentation will describe 1) the goals of this proof of concept testing, 2) the lessons learned when designing and building these Inconel 718 test specimens to minimize beam time, 3) the neutron imaging test setup and test procedure to get the images, 4) the initial results in images, volume and a video, 4) the assessment of using this imaging technique to gather real data for designing internal flow passages in SLM manufacturing aerospace hardware, and lastly 5) how proper cleaning of the internal passages is critically important. In summary, the initial results are very promising and continued development of a technique to assist in SLM development for aerospace components is desired by both NASA and ORNL. A plan forward that benefits both ORNL and NASA will also be presented, based on the promising initial results. The initial images and volume reconstruction showed that clean, clear images of the internal passages geometry are obtainable. These clear images of the internal passages of simple geometries will be compared to the build model to determine any differences. One surprising result was that a new cleaning process was used on these simply geometric specimens that resulted in what appears to be very smooth internal surfaces, when compared to other aerospace hardware cleaning methods.

Tramel, Terri L.↗

Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Seamless Flaps

Computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a Gulfstream G-III airplane (Gulfstream Aerospace Corporation, Savannah, Georgia) swept wing modified with an experimental seamless, compliant flap called the Adaptive Compliant Trailing Edge (ACTE) flap. The stall characteristics of the modified ACTE wing were analyzed and compared with the unmodified, clean wing at the flight speed of 120 knots and altitude of 2300 feet above mean sea level, in free air as well as in ground effect. A polyhedral finite-volume unstructured full Navier-Stokes CFD code, STAR-CCM (registered trademark) plus (CD-adapco [Computational Dynamics Limited, United Kingdom, and Analysis & Design Application Co., United States]), was used. Steady Reynolds-averaged Navier-Stokes CFD simulations were conducted for a clean wing and the ACTE wings at various ACTE deflection angles in free air (-2 degrees, 15 degrees, and 30 degrees) as well as in ground effect (15 degrees and 30 degrees). Solution sensitivities to grid densities were examined. In free air, the ACTE wings are predicted to stall at lower angles of attack than the clean wing. In ground effect, all wings are predicted to stall at lower angles of attack than the corresponding wings in free air. Even though the lift curves are higher in ground effect than in free air, the maximum lift coefficients for all wings are lower in ground effect. Finally, the lift increase due to ground effect for the ACTE wing is predicted to be less than the clean wing.

CFD↗

Brushing Your Spacecrafts Teeth: A Review of Biological Reduction Processes for Planetary Protection Missions

Much like keeping your teeth clean, where you brush away biofilms that your dentist calls "plaque," there are various methods to clean spaceflight hardware of biological contamination, known as biological reduction processes. Different approaches clean your hardware's "teeth" in different ways and with different levels of effectiveness. We know that brushing at home with a simple toothbrush is convenient and has a different level of impact vs. getting your teeth cleaned at the dentist. In the same way, there are some approaches to biological reduction that may require simple tools or more complex implementation approaches (think about sonicating or just soaking your dentures, vs. brushing them). There are also some that are more effective for different degrees of cleanliness and still some that have materials compatibility concerns. In this article, we review known and NASA-certified approaches for biological reduction, pointing out materials compatibility concerns and areas where additional research is needed.

Pugel, D. E. (Betsy)↗

Brushing Your Spacecrafts Teeth: A Review of Biological Reduction Processes for Planetary Protection Missions

Much like keeping your teeth clean, where you brush away biofilms that your dentist calls plaque, there are various methods to clean spaceflight hardware of biological contamination, known as biological reduction processes. Different approaches clean your hardwares teeth in different ways and with different levels of effectiveness. We know that brushing at home with a simple toothbrush is convenient and has a different level of impact vs. getting your teeth cleaned at the dentist. In the same way, there are some approaches to biological reduction that may require simple tools or more complex implementation approaches (think about sonicating or just soaking your dentures, vs. brushing them). There are also some that are more effective for different degrees of cleanliness and still some that have materials compatibility concerns. In this article, we review known and NASA-certified approaches for biological reduction, pointing out materials compatibility concerns and areas where additional research is needed.

Pugel, D.E. (Betsy)↗

X-Ray Photoelectron Spectroscopy

The interaction of photon and the electron goes back to the early part of 19th century emanating from the photo-electric effect depicted by none other than Albert Einstein (Ref 1) described in 1905, and the redistribution of kinetic energy resulting from the interaction of x-ray and solids reported during early part of the century (Ref.2). The spectrum resolutions obtained at that time was not sufficient to observe distinct peaks in spectra for materials. Thus, these phenomena hardly attracted any attention for many years following these discoveries. The modern X-ray Photoelectron Spectroscopy (XPS) has been possible by the extensive and significant contribution from Kai Siegbahn and others (Ref.3, 4) of Uppsala University. Siegbahn developed and employed a high-resolution electron spectrometer that revealed electron peaks in a spectrum emerging from the interaction of x-rays and solids. Eventually, Kai Siegbahn received Nobel Prize in 1981 for his contributions to XPS. Around 1958, shifts in elemental peaks were realized in compounds when the same elements are bound to other but different elements. This discovery resulted in the chemical state identification in various chemicals as well as the oxidation states of atoms in compounds. Because of these useful physical effects, the Uppsala group named XPS with a synonymous name of ESCA (Electron Spectroscopy for Chemical Analysis) used widely today and will be used here alternatively. Therefore, XPS or ESCA not only identifies the element, but also the compound these elements form, from their chemical shifts. Compared to other micro-analytical techniques such as Energy Dispersive (EDS) or Wavelength Dispersive (WDS) techniques, XPS analyzes only few atomic layers present on the surface. This was discovered early in 1966 (Ref. 5). While this has awarded a merit to the analytical technique to analyze very thin layers such as films and coatings, it often analyzes the adsorbed superficial gases and contaminations on a sample introduced to its analytical chamber. This necessitates the surface is cleaned and the underlying material, material of interest, is exposed in a clean environment such that the material of interest is analyzed. The cleaning is accomplished by a scanning ion gun within the analytical chamber of the instrument. Ion gun uses an argon gas and is commonly attached in most modern machines. Reliable and efficient vacuum systems employed in modern machines does not allow adsorbed layers to rebuild after the surface is cleaned. Development of efficient and reliable vacuum pumps over these developmental years is yet another important step in the commercialization of XPS machines. Vacuum levels of better than 10-7 torr are essential to increase the mean free path of electrons released from the sample surface. Thus, modern machines are equipped with high capacity ion, turbo or cryogenic pumps in their analytical chambers. Today, XPS has advanced from an applied physics laboratory to industry for use in quality control as well as analysis of contaminants and has taken a dominant role in microanalysis. Its uniqueness arises from the fact that it is considered non-destructive compared to other common micro-analytical techniques using the electron and ion excitation sources. Polymers and plastics could be analyzed since the binding energies of saturated and unsaturated bonds in atoms could be separated. Extremely thin layers could be analyzed including materials with layered structures. The technique, though did not advance for many years, has now opened a new window for research as well as applications in industry due to its ability to separate and measure the chemical shifts in bound elements. Principles

Panda, Binayak↗

Reduced Organic Outgassing in the NASA Osiris-Rex and Hayabusa2 Curation Facility by Careful Selection and Implementation of Cleanroom Construction Materials

In October 2021, NASA Johnson Space Center (JSC) Astromaterials Acquisition and Cu-ration Office in JSC bldg. 31 completed construction and commissioning of the OSIRIS-REx and Hayabusa2cleanroom laboratory suites along with new precision cleaning and advanced curation laboratories: •OSIRIS-REx Curation Cleanroom: ISO Class 5•Hayabusa2 Curation Cleanroom: ISO Class 5•Final Precision Cleaning Cleanroom: ISO Class 5•Advanced Precision Cleaning Cleanroom: ISO Class 6•PreClean Precision Cleaning Cleanroom: ISO Class 6•Advanced Curation Cleanroom: ISO Class 7The new curation facilities are designed for initial receiving, basic characterization, curation processing, and preliminary examination of carbonaceous asteroidal material. The facilities are also designed to enable long-term pristine sample storage to preserve the scientific integrity of each sample to enable decades of future re-search by the international science community. The scientific study of organics in general is critical for both missions. The OSIRIS-REx mission executed a stringent contamination control plan [1] where all sample hardware at time of sample acquisition would be at Level 100 A/2 per IEST-STD-CC1246D (non-volatile residue (NVR) < 500 ng/cm2). In addition, the mission imposed a requirement of <180 ng/cm2 for amino acids (and hydrazine) [1]. Given these mission requirements, long-term storage preservation requirements, and information from the Organic Contamination Baseline Study at JSC [2], the JSC Curation team decided to carefully select cleanroom construction materials that would not hinder the scientific search for amino acids and the study of organics in the samples [3].

astromaterials curation↗