SEARCH · Engineering Papers
Results for “CANDIDATES”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Impact of Insurance Status on Radiation Treatment Modality Selection Among Potential Candidates for Prostate, Breast, or Gynecologic Brachytherapy
Purpose: The Patient Protection and Affordable Care Act looks to expand both private and Medicaid insurance. To evaluate how these changes may affect the field of radiation oncology, we evaluated the association of insurance status with the use of brachytherapy in cancers for which this treatment technique is used. Methods and Materials: A total of 190,467 patients met the inclusion criteria, of whom 95,292 (50.0%) had breast cancer, 61,096 (32.1%) had prostate cancer, 28,194 (14.8%) had endometrial cancer, and 5885 (3.1%) had cervical cancer. A multivariate logistic regression model was used to determine the association between insurance status and receipt of brachytherapy among patients treated definitively for prostate and cervical cancer or postoperatively for breast and endometrial cancer. Results: The rates of non-Medicaid insurance were 49.9% (cervical), 85.3% (endometrial), 87.4% (breast), and 90.9% (prostate) (P<.001). In a logistic regression, patients who received radiation therapy were less likely to receive brachytherapy if they had Medicaid coverage (odds ratio [OR] 0.57, 95% confidence interval [CI] 0.53-0.61, P<.001) or did not have insurance coverage (OR 0.50, 95% CI 0.45-0.56, P<.001) compared with those with non-Medicaid insurance. On subset analysis, patients with Medicaid coverage or without insurance coverage were significantly less likely to receive brachytherapy than were those with non-Medicaid insurance for all 4 sites, except for patients with endometrial cancer. Conclusions: Despite being a cost-effective treatment modality, brachytherapy is less often used in the definitive or postoperative management of cancer in patients with Medicaid coverage or without insurance. Upcoming health policy changes resulting in the expansion of private insurance and Medicaid will likely increase access to and demand for brachytherapy.
Radiation-Induced Esophagitis In Vivo and In Vitro Reveals That Epidermal Growth Factor Is a Potential Candidate for Therapeutic Intervention Strategy
Purpose: To establish and characterize radiation-induced esophagitis (RIE) in vivo and in vitro. Methods and Materials: Fractionated thoracic irradiation at 0, 8, 12, or 15 Gy was given daily for 5 days to Balb/c or C57Bl/6 mice. Changes in body weight gain and daily food intake were assessed. At the end of the study, we removed the esophagus and examined histology by hematoxylin and eosin staining, immune cell infiltration and apoptosis by fluorescence-activated cell sorting, and gene expression changes by quantitative real-time polymerase chain reaction. Het-1A human esophageal epithelial cells were irradiated at 6 Gy, treated with recombinant human growth factors, and examined for gene expression changes, apoptosis, proliferation, and signal transduction pathways. Results: We observed that irradiation at 12 Gy or 15 Gy per fraction produced significant reduction in body weight and decreased food intake in Balb/c mice but not as much in C57Bl/6 mice. Further analyses of Balb/c mice irradiated at 12 Gy/fraction revealed attenuated epithelium, inflamed mucosa, and increased numbers of infiltrating CD4+ helper T cells and apoptotic cells. Moreover, we found that expression of tissue inhibitor for metalloproteinase-1, plasminogen activator inhibitor-1, granulocyte macrophage-colony stimulating factor, vascular endothelial growth factor, and stromal-derived factor-1 were increased, whereas epidermal growth factor (EGF) was decreased. Irradiated Het-1A cells similarly showed a significant decrease in expression of EGF and connective tissue growth factor (CTGF). Treatment of EGF but not CTGF partially protected Het-1A cells from radiation-induced apoptosis and revealed phosphorylation of EGFR, AKT, and ERK signaling pathways. Conclusions: We established a mouse model of RIE in Balb/c mice with 12 Gy × 5 fractions, which showed reduced body weight gain, food intake, and histopathologic features similar to those of human esophagitis. Decreased EGF expression in the irradiated esophagus suggests that EGF may be a potential therapeutic intervention strategy to treat RIE.
Progress in development of characterization capabilities to evaluate candidate materials for direct air capture applications
As part of U.S. national efforts to combat the detrimental effect of global climate change, the National Institute of Standards and Technology (NIST) was recently tasked to support efforts in direct air capture (DAC) of carbon dioxide research and deployment. In order to develop test procedures, materials, and documentary standards, key characterization methods relevant to DAC materials have been investigated and used to identify desirable properties for a potential Standard Reference Material (SRM). Select amine-supported materials that previously showed potential for DAC applications have been characterized using commonly available laboratory methods. Further insights into the adsorption characteristics have been gained from developing and applying more specialized characterization tools ideal for probing low concentrations of carbon dioxide. A broad suite of capabilities that examine relevant properties under appropriate conditions gives the most profound insights into a material's specific performance. We advocate for even more specialized capabilities to be developed and standardized to quantitatively monitor the interactions of CO 2 with molecular species in complex and often disordered systems to advance DAC and support carbon dioxide reduction (CDR) in general.
Proton Irradiation Study of GFR Candidate Ceramics
This work investigated the microstructural response of ZrC, ZrN, TiN, and SiC irradiated with 2.6 MeV protons at 800ºC to a single dose in the range of 1.5 to 3.0 displacement per atom (dpa), depending on the material. The change of lattice constant evaluated using HOLZ patterns is not observed and is small when measured using XRD for the irradiated samples up to 1.5 dpa for 6H-SiC, and up to 3.0 dpa for ZrC and ZrN. In comparison to Kr ion irradiation at 800ºC to 10 dpa from the previous studies, the proton-irradiated ceramics at 3.0 dpa show less irradiation damage to the lattice structure. The irradiated ZrC exhibits faulted loops which are not observed in the Kr ion irradiated sample. The irradiated ZrN shows the least microstructural change from proton irradiation. The microstructure of 6H-SiC irradiated to 3.0 dpa consists of a black dot defect type at high density.
Oxidation of Fuel Cladding Candidate Materials in Steam Environments at High Temperature and Pressure
Under certain severe accident conditions, the fuel rods of nuclear power plants are exposed to high temperature/pressure steam environments in which the Zr alloy cladding is rapidly oxidized. As alternative claddings, the oxidation resistances of SiC-based materials and stainless steels with high Cr and/or Al additions have been examined from 800-1200 C in high-pressure steam environments. Very low reaction kinetics were observed with alumina-forming FeCrAl alloys at 1200 C while Fe-Cr alloys with only 15-20% Cr were rapidly attacked.
High Temperature Oxidation of Fuel Cladding Candidate Materials in Steam-Hydrogen Environments
Explore the source record for details and available documents.
Solution of hydrogen in accident tolerant fuel candidate material: U3Si2
Not Available
Defect evolution in burnable absorber candidate material: Uranium diboride, UB2
Not Available
Coefficient of friction evolution with temperature under fretting wear for FeCrAl fuel cladding candidate
Not Available
Synergies between H, He and radiation damage in dual and triple ion irradiation of candidate fusion blanket materials
Three ferritic/martensitic alloys were studied to understand the synergistic effect between single ion beam (Fe 2+ ), dual ion beam (Fe 2+ +He 2+ and Fe 2+ +H + ), and triple ion beam (Fe 2+ +He 2+ +H + ) irradiations on cavity evolution. A commercial alloy, F82H, a castable nanostructured alloy, CNA3, and a high purity model alloy, Fe8Cr2W, were irradiated at 400°C to 600°C to a damage level of 50 dpa at a damage rate of 1 × 10 –3 dpa/s with He and H injection rates of 10 and 40 appm/dpa, respectively. Post-irradiation characterization via bright field transmission electron microscopy and high-angle annular dark-field scanning transmission electron microscopy was performed on all irradiated conditions to characterize the cavity size distribution and determine the effects of H/He injection on cavity microstructure. In all three alloys, hydrogen co-injection with helium resulted in an increased cavity number density and maximum cavity size, producing an increase in swelling over that from helium injection alone. Swelling in F82H appears to peak between 450°C and 500°C. At 600°C, swelling was minimal and cavities of high density and small size were confined to grain boundaries and dislocations while at 400°C, swelling is also low with a nearly homogeneous, high density, distribution of very small cavities throughout. Swelling was least in the commercial alloy F82H due to the high sink strength. The CNA3 alloy underwent dissolution of precipitates that lowered the sink strength and resulted in higher swelling than F82H, but less than the model alloy. Electron energy loss spectroscopy (EELS) elemental mapping revealed hydrogen forming a halo-like structure about the periphery of the cavities and helium residing within the cavities themselves. Finally, this observation suggests that hydrogen reduces the surface energy of helium-filled cavities which results in both increased cavity number density and cavity size in triple beam irradiation over dual beam irradiation.
Design Principles and Top Non-Fullerene Acceptor Candidates for Organic Photovoltaics
Not Available
A candidate accident tolerant fuel system based on a highly concentrated alloy thin film
The feasibility of depositing a thin film of highly concentrated alloy on zircaloy-4 substrates at low temperatures was investigated. Electron microscopy characterisation at micro and nanoscales showed that the deposited thin film is near-equiatomic, single-phase and with all alloying elements uniformly distributed throughout the microstructure. Heavy-ion irradiations carried out in situ within a transmission electron microscope displayed the generation of both defect clusters and inert gas bubbles at around 1.5 × 10 16 ions·cm –2 (15.4 dpa). Post-irradiation characterisation demonstrated that the thin film preserved its solid solution and that, under the studied conditions, no elemental segregation or phase transformations were observed, indicating a high radiation tolerance.
Bayesian automated weighting of aggregated DFT, MD, and experimental data for candidate thermodynamic models of aluminum with uncertainty quantification
Atomic-scale modeling methods such as density functional theory (DFT) and molecular dynamics (MD) can predict the thermodynamic properties of materials at a lower cost than experimental measurements. However, their regular usage in thermodynamic model construction is hampered by the lack of quantitative agreement with experimental measurements and the lack of uncertainty estimates on the data. To make regular usage of this atomistic simulation data, it is important to assess whether the atomistic simulation datasets, by themselves or in combination with experimental measurements, result in the same physics-informed models best supported by experimental measurements alone. Here, models of aluminum thermodynamic properties are discussed using three data sources: atomistic calculations (DFT and MD), experiments, and a combination of atomistic calculations and experiments. The study shows that, after ensuring self-consistency in predicting key invariant points, both experimental measurements and atomistic calculations can significantly contribute to an optimal model.
Test of candidate light distributors for the muon (g−2) laser calibration system
The new muon ( g −2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.
A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope
The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.