Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Measurement of Acute Changes in Choroid Thickness in Healthy Eyes During Posture Change Using Optical Coherence Tomography

The Visual Impairment and Intracranial Pressure (VIIP) syndrome affects 60% of astronauts returning from long-duration missions and is characterized by structural and functional changes of the eye (3). Upon entry into weightlessness, approximately two liters of fluid translocates from the lower body to the thorax and cephalad regions, potentially contributing to elevated intracranial and intraocular pressures. The choroid is the vasculature that supplies blood flow to the posterior part of the retina and has limited autoregulation. As a consequence these vessels may engorge during a cephalad fluid shift, contributing to structural changes in the retina. The purpose of this experiment was to quantify changes in choroid thickness during a fluid shift. In order to fulfill this objective, it was also necessary to improve the measurement technique for assessing choroid thickness.

Ferguson, Connor R.↗

Assessing blood brain barrier dynamics or identifying or measuring selected substances, including ethanol or toxins, in a subject by analyzing Raman spectrum signals

A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier.Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam at a selected wavelength (e.g., at a wavelength of about 400 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

Lambert, James L.↗

Regulation of skeletal muscle perfusion during exercise

For exercise to be sustained, it is essential that adequate blood flow be provided to skeletal muscle. The local vascular control mechanisms involved in regulating muscle perfusion during exercise include metabolic control, endothelium-mediated control, propagated responses, myogenic control, and the muscle pump. The primary determinant of muscle perfusion during sustained exercise is the metabolic rate of the muscle. Metabolites from contracting muscle diffuse to resistance arterioles and act directly to induce vasodilation, or indirectly to inhibit noradrenaline release from sympathetic nerve endings and oppose alpha-adrenoreceptor-mediated vasoconstriction. The vascular endothelium also releases vasodilator substances (e.g., prostacyclin and nitric oxide) that are prominent in establishing basal vascular tone, but these substances do not appear to contribute to the exercise hyperemia in muscle. Endothelial and smooth muscle cells may also be involved in propagating vasodilator signals along arterioles to parent and daughter vessels. Myogenic autoregulation does not appear to be involved in the exercise hyperemia in muscle, but the rhythmic propulsion of blood from skeletal muscle veins facilitates venous return to the heart and muscle perfusion. It appears that the primary determinants of sustained exercise hyperemia in skeletal muscle are metabolic vasodilation and increased vascular conductance via the muscle pump. Additionally, sympathetic neural control is important in regulating muscle blood flow during exercise.

Non-NASA Center↗

Balloon Angioplasty Optimization: Should We Measure Balloon Volume As Well As Pressure?

Purpose. To investigate the influence that measurement of balloon volume as a controlled variable in addition to balloon pressure has on the outcome of balloon angioplasty in an experimental model. Methods. One hundred and three segments of explanted normal porcine carotid arteries were obtained. Five were used as controls, and the remaining 98 were subjected to balloon angioplasty with simultaneous measurement of balloon volume and pressure. These arteries were randomized into two groups. In one group the endpoint of the angioplasty was determined by balloon pressure (pressure-limited group, PLG) and in the other group by balloon volume (volume-limited group, VLG). Pressure/volume curves for each procedure were constructed by continuous measurement of both parameters by a purpose-designed computer-controlled inflation device. The diameter of each arterial segment was measured by intravascular ultrasound (IVUS) and the ratio of the inflated balloon to arterial diameter calculated. Arterial appearances after angioplasty were recorded using IVUS. Results. The balloon volumes measured at the endpoint of angioplasty were significantly smaller in the PLG compared with the VLG (p < 0.001). Three types of pressure/volume curves were identified: A, B, and C. In the type A curves, IVUS identified fissures in 28% (17/60) and the examination was normal in 72% (43/60). In the type B curves, IVUS identified fissures in 44% (4/9), dissections in 22% (2/9), and the examination was normal in 33% (3/9). In the type C curves, IVUS identified fissures in 44% (4/9) and dissection in 56% (5/9) with no normal examinations. In undamaged arterial segments a very high correlation was achieved between balloon volume and the balloon/artery ratio (Pearson correlation = -0.979, R{sup 2} = 0.957, p < 0.0001, n = 27). Conclusion. The measurement of pressure and volume during angioplasty enabled the construction of pressure/volume curves that showed deviations from the curves obtained in air. The balloon volume results, and significant deviation of the curve shape from the control curve shape, predicted vessel damage, which was confirmed by the IVUS appearance of the vessel after angioplasty. When pressure was used as the endpoint of balloon inflation the balloons were significantly underdilated compared with the manufacturer's nominal sizes. These data indicate that monitoring of pressure and volume during angioplasty may provide an alternative method of predicting vessel damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Therapeutic Window of Regenerative Opportunity in Diabetic Retinopathy by VESGEN Analysis

Vascular pattern may serve as a useful new biomarker principle of complex, multi-scale signaling in pathological, physiological angiogenesis and microvascular remodeling. Each angiogenesis stimulator or inhibitor we have analyzed, including VEGF, bFGF, TGF-beta1, angiostatin and triamcinolone acetonide, has induced a novel "fingerprint" or "signature" biomarker vascular pattern that is spatio-temporally unique. Remodeling vasculature thereby provides an informative read-out of dominant molecular signaling, when analyzed by innovative, fractal-based VESsel GENeration (VESGEN) Analysis software. Using VESGEN to analyze ophthalmic clinical vascular images, we recently introduced a potential paradigm shift to the understanding of early-stage progression that suggests new regenerative opportunities for human diabetic retinopathy (DR), the major blinding disease for working-aged adults. In a pilot study, we discovered that angiogenesis oscillates as a surprising, homeostatic-like regeneration of retinal vessels during early progression of DR (IOVS 51(1):498). Results suggest that the term non-proliferative DR may be a misnomer. In new studies, normalization of the vasculature will be determined from the response of vascular pattern to therapeutic monitoring and treatment. We have mapped and quantified in vivo experimental models of angiogenesis, lymphangiogenesis and intravital blood flow from cellular/molecular to higher systems levels that include a murine model of infant retinopathy of prematurity (ROP); developing and pathological coronary and placental-like vessel models; progressive intestinal inflammation, growing murine tumors, and other pathological, physiological and therapeutically treated tissues of transgenic mice and avian embryos. Vascular Alterations, Visual Impairments (VIIP) & Increased Intracranial Pressure (ICP), Immunosuppression & Bone Loss: NASA-defined risk categories for human space exploration and ISS Utilization

Parsons-Wingert, Patricia A.↗

Microvascular Branching as a Determinant of Blood Flow by Intravital Particle Imaging Velocimetry

The effects of microvascular branching on blood flow were investigated in vivo by microscopic particle imaging velocimetry (micro-PIV). We use micro-PIV to measure blood flow by tracking red blood cells (RBC) as the moving particles. Velocity flow fields, including flow pulsatility, were analyzed for the first four branching orders of capillaries, postcapillary venules and small veins of the microvascular network within the developing avian yolksac at embryonic day 5 (E5). Increasing volumetric flowrates were obtained from parabolic laminar flow profiles as a function of increasing vessel diameter and branching order. Maximum flow velocities increased approximately twenty-fold as the function of increasing vessel diameter and branching order compared to flow velocities of 100 - 150 micron/sec in the capillaries. Results from our study will be useful for the increased understanding of blood flow within anastomotic, heterogeneous microvascular networks.

Parsons-Wingerter, Patricia↗

Volumetric cutaneous microangiography of human skin in vivo by VCSEL swept-source optical coherence tomography

We demonstrate volumetric cutaneous microangiography of the human skin in vivo that utilises 1.3-μm high-speed sweptsource optical coherence tomography (SS-OCT). The swept source is based on a micro-electro-mechanical (MEMS)-tunable vertical cavity surface emission laser (VCSEL) that is advantageous in terms of long coherence length over 50 mm and 100 nm spectral bandwidth, which enables the visualisation of microstructures within a few mm from the skin surface. We show that the skin microvasculature can be delineated in 3D SS-OCT images using ultrahigh-sensitive optical microangiography (UHS-OMAG) with a correlation mapping mask, providing a contrast enhanced blood perfusion map with capillary flow sensitivity. 3D microangiograms of a healthy human finger are shown with distinct cutaneous vessel architectures from different dermal layers and even within hypodermis. These findings suggest that the OCT microangiography could be a beneficial biomedical assay to assess cutaneous vascular functions in clinic. (laser biophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The cerebral hemodynamics of normotensive hypovolemia during lower-body negative pressure

Although severe hypovolemia can lead to hypotension and neurological decline, many patients with neurosurgical disorders experience a significant hypovolemia while autonomic compensatory mechanisms maintain a normal blood pressure. To assess the effects of normotensive hypovolemia upon cerebral hemodynamics, transcranial Doppler ultrasound monitoring of 13 healthy volunteers was performed during graded lower-body negative pressure of up to -50 mm Hg, an accepted laboratory model for reproducing the physiological effects of hypovolemia. Middle cerebral artery flow velocity declined by 16% +/- 4% (mean +/- standard error of the mean) and the ratio between transcranial Doppler ultrasound pulsatility and systemic pulsatility rose 22% +/- 8%, suggesting cerebral small-vessel vasoconstriction in response to the sympathetic activation unmasked by lower-body negative pressure. This vasoconstriction may interfere with the autoregulatory response to a sudden fall in blood pressure, and may explain the common observation of neurological deficit during hypovolemia even with a normal blood pressure.

Non-NASA Center↗

SU-D-18C-02: Feasibility of Using a Short ASL Scan for Calibrating Cerebral Blood Flow Obtained From DSC-MRI

Purpose: This study aimed to evaluate the feasibility of using a short arterial spin labeling (ASL) scan for calibrating the dynamic susceptibility contrast- (DSC-) MRI in a group of patients with internal carotid artery stenosis. Methods: Six patients with unilateral ICA stenosis enrolled in the study on a 3T clinical MRI scanner. The ASL-cerebral blood flow (-CBF) maps were calculated by averaging different number of dynamic points (N=1-45) acquired by using a Q2TIPS sequence. For DSC perfusion analysis, arterial input function was selected to derive the relative cerebral blood flow (rCBF) map and the delay (Tmax) map. Patient-specific CF was calculated from the mean ASL- and DSC-CBF obtained from three different masks: (1)Tmax< 3s, (2)combined gray matter mask with mask 1, (3)mask 2 with large vessels removed. One CF value was created for each number of averages by using each of the three masks for calibrating the DSC-CBF map. The CF value of the largest number of averages (NL=45) was used to determine the acceptable range(< 10%, <15%, and <20%) of CF values corresponding to the minimally acceptable number of average (NS) for each patient. Results: Comparing DSC CBF maps corrected by CF values of NL (CBFL) in ACA, MCA and PCA territories, all masks resulted in smaller CBF on the ipsilateral side than the contralateral side of the MCA territory(p<.05). The values obtained from mask 1 were significantly different than the mask 3(p<.05). Using mask 3, the medium values of Ns were 4(<10%), 2(<15%) and 2(<20%), with the worst case scenario (maximum Ns) of 25, 4, and 4, respectively. Conclusion: This study found that reliable calibration of DSC-CBF can be achieved from a short pulsed ASL scan. We suggested use a mask based on the Tmax threshold, the inclusion of gray matter only and the exclusion of large vessels for performing the calibration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record↗

Effects of Long Duration Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure syndrome (VIIP) is a newly described space flight-associated medical condition made up of a constellation of symptoms affecting at least 34% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures, and is thought to be related to elevated intracranial pressure secondary to space flightinduced cephalad fluid shifts. Loss of visual acuity could be a significant threat to crew health and performance and may be suggestive of other adaptations with implications for years post-flight. Our primary objective is to determine whether vascular compliance is altered by space flight and whether such adaptations are related to the incidence of VIIP. In particular, we will measure ocular parameters and vascular compliance in vessels of the head and neck in astronauts who have no space flight experience, in astronauts before, during, and after space flight, and in bed rest subjects with conditions similar to space flight. Additionally, we will analyze astronaut data from the Lifetime Surveillance of Astronaut Health (LSAH) archive to determine which factors might be predictive of the development of VIIP. The project will be conducted in four separate but related parts. To understand the baseline condition of astronauts without any prior space flight experience, we will study 10 astronauts who have never flown in space by performing a comprehensive evaluation of the vasculature of the head, neck and eyes. Hemodynamic data (stroke volume and blood pressure), ocular (tonometry and ocular ultrasound), venous and arterial parameters will be acquired across a range of tilt angles (20, 10, 0, -10, -20 degrees). Vessels to be studied include the temporal, jugular, and vertebral veins and the cerebral, carotid and vertebral arteries. Ophthalmic data from the annual physical will be obtained through data sharing. To examine the relation between vascular compliance in the head and neck and the development of VIIP after a long duration space flight, we will study 10 astronauts before, during, and after long-duration ISS missions. Pre- and post-flight testing will be identical to that described above. During flight, images of the same vessels of interest will be obtained for later analysis. Ophthalmic data including VIIP scores will be obtained through data sharing from medically-required tests. To investigate the effects of age and elevated sodium intake, two potential contributors to VIIP, we will study 24 men (in two age groups: 25-35 and 45-55) during a 14 day 6deg head-down bed rest, a well-accepted analog of space flight. Standard NASA bed rest conditions will be maintained except for dietary sodium. Sodium intake will be similar to that of ISS astronauts, which is higher than consumed in previous bed rest studies. Pre- and post-bed rest testing procedures will be identical to the testing protocol described above for astronauts. Ophthalmic testing (optical coherence tomography, fundoscopy, and tonometry) will be conducted on the same day that vascular compliance measures are obtained. To identify parameters that may relate to an increase in an astronaut's susceptibility to developing VIIP, we will use data mining techniques to evaluate astronaut data obtained from the LSAH. Medical history, family history, space flight history and its related exposures, and history of high performance jet aircraft exposure will be examined for their potential relationship to ocular data. We hypothesize that the cephalad fluid shift induced by space flight will result in structural and functional adaptations in head and neck vessels leading to decreased vascular compliance and related to the development of VIIP symptoms. Further, although VIIP has not been observed in previous bed rest studies, we hypothesize that an elevated sodium intake will increase the incidence of VIIP symptoms in this space flight analog. Finally, we hypothesize that data mining analyses will reveal relationships between health history, previous exposures (including space flight and high performance aircraft), and the development of VIIP in the astronaut population.

Ribeiro, L. C.↗

Effect of furosemide on pulmonary blood flow distribution in resting and exercising horses

We determined the spatial distribution of pulmonary blood flow (PBF) with 15-micron fluorescent-labeled microspheres during rest and exercise in five Thoroughbred horses before and 4 h after furosemide administration (0.5 mg/kg iv). The primary finding of this study was that PBF redistribution occurred from rest to exercise, both with and without furosemide. However, there was less blood flow to the dorsal portion of the lung during exercise postfurosemide compared with prefurosemide. Furosemide did alter the resting perfusion distribution by increasing the flow to the ventral regions of the lung; however, that increase in flow was abated with exercise. Other findings included 1) unchanged gas exchange and cardiac output during rest and exercise after vs. before furosemide, 2) a decrease in pulmonary arterial pressure after furosemide, 3) an increase in the slope of the relationship of PBF vs. vertical height up the lung during exercise, both with and without furosemide, and 4) a decrease in blood flow to the dorsal region of the lung at rest after furosemide. Pulmonary perfusion variability within the lung may be a function of the anatomy of the pulmonary vessels that results in a predominantly fixed spatial pattern of flow distribution.

NASA Discipline Cardiopulmonary↗

Blood flow

A heuristic treatment of blood flow in the heart and the aorta together with some of the main branches considers the effects of fluid viscosity and vessel elasticity as well as pressure distribution in the typical pulsating flow.

Jones, R. T.↗

Loss of signal transduction and inhibition of lymphocyte locomotion in a ground-based model of microgravity

Inflammatory adherence to, and locomotion through the interstitium is an important component of the immune response. Conditions such as microgravity and modeled microgravity (MMG) severely inhibit lymphocyte locomotion in vitro through gelled type I collagen. We used the NASA rotating wall vessel bioreactor or slow-turning lateral vessel as a prototype for MMG in ground-based experiments. Previous experiments from our laboratory revealed that when lymphocytes (human peripheral blood mononuclear cells [PBMCs]) were first activated with phytohemaglutinin followed by exposure to MMG, locomotory capacity was not affected. In the present study, MMG inhibits lymphocyte locomotion in a manner similar to that observed in microgravity. Phorbol myristate acetate (PMA) treatment of PBMCs restored lost locomotory capacity by a maximum of 87%. Augmentation of cellular calcium flux with ionomycin had no restorative effect. Treatment of lymphocytes with mitomycin C prior to exposure to MMG, followed by PMA, restored locomotion to the same extent as when nonmitomycin C-treated lymphocytes were exposed to MMG (80-87%), suggesting that deoxyribonucleic acid replication is not essential for the restoration of locomotion. Thus, direct activation of protein kinase C (PKC) with PMA was effective in restoring locomotion in MMG comparable to the normal levels seen in Ig cultures. Therefore, in MMG, lymphocyte calcium signaling pathways were functional, with defects occurring at either the level of PKC or upstream of PKC.

NASA Discipline Cell Biology↗

Transcription factor COUP-TFII is indispensable for venous and lymphatic development in zebrafish and Xenopus laevis

Highlights: {yields} COUP-TFII deficiency in zebrafish affects arterio-venous EC specification. {yields} COUP-TFII is indispensable for lymphatic development in zebrafish. {yields} COUP-TFII knockdown in Xenopus disrupts lymphatic EC differentiation and migration. {yields} COUP-TFII's role in EC fate decisions is evolutionary conserved. -- Abstract: Transcription factors play a central role in cell fate determination. Gene targeting in mice revealed that Chicken Ovalbumin Upstream Promoter-Transcription Factor II (COUP-TFII, also known as Nuclear Receptor 2F2 or NR2F2) induces a venous phenotype in endothelial cells (ECs). More recently, NR2F2 was shown to be required for initiating the expression of Prox1, responsible for lymphatic commitment of venous ECs. Small animal models like zebrafish embryos and Xenopus laevis tadpoles have been very useful to elucidate mechanisms of (lymph) vascular development. Therefore, the role of NR2F2 in (lymph) vascular development was studied by eliminating its expression in these models. Like in mice, absence of NR2F2 in zebrafish resulted in distinct vascular defects including loss of venous marker expression, major trunk vessel fusion and vascular leakage. Both in zebrafish and Xenopus the development of the main lymphatic structures was severely hampered. NR2F2 knockdown significantly decreased prox1 expression in zebrafish ECs and the same manipulation affected lymphatic (L)EC commitment, migration and function in Xenopus tadpoles. Therefore, the role of NR2F2 in EC fate determination is evolutionary conserved.

60 APPLIED LIFE SCIENCES↗

On the near-wall accumulation of injectable particles in the microcirculation: smaller is not better

Although most nanofabrication techniques can control nano/micro particle (NMP) size over a wide range, the majority of NMPs for biomedical applications exhibits a diameter of ,100 nm. Here, the vascular distribution of spherical particles, from 10 to 1,000 nm in diameter, is studied using intravital microscopy and computational modeling. Small NMPs (#100 nm) are observed to move with Red Blood Cells (RBCs), presenting an uniform radial distribution and limited near-wall accumulation. Larger NMPs tend to preferentially accumulate next to the vessel walls, in a size-dependent manner (,70% for 1,000 nm NMPs). RBC-NMP geometrical interference only is responsible for this behavior. In a capillary flow, the effective radial dispersion coefficient of 1,000 nm particles is ,3-fold larger than Brownian diffusion. This suggests that sub-micron particles could deposit within diseased vascular districts more efficiently than conventional nanoparticles.

BIOMEDICAL MATERIALS↗

Subintimal Recanalization of Occluded Stents: The Substent Technique

PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end points included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan-Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 {+-} 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 {+-} 90.78 mm. The mean occluded stented segment length was 90.21 {+-} 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year's follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few alternatives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-contact optoacoustic imaging with focused air-coupled transducers

Non-contact optoacoustic imaging employing raster-scanning of a spherically focused air-coupled ultrasound transducer is showcased herein. Optoacoustic excitation with laser fluence within the maximal permissible human exposure limits in the visible and near-infrared spectra is applied to objects with characteristic dimensions smaller than 1 mm and absorption properties representative of the whole blood at near-infrared wavelengths, and these signals are shown to be detectable without contact to the sample using an air-coupled transducer with reasonable signal averaging. Optoacoustic images of vessel-mimicking tubes embedded in an agar phantom captured with this non-contact sensing technique are also showcased. These initial results indicate that an air-coupled ultrasound detection approach can be suitable for non-contact biomedical imaging with optoacoustics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗